• Title/Summary/Keyword: Electromagnetic Immunity

Search Result 97, Processing Time 0.028 seconds

A Study on the Radiated Noise from Power Line during EFT Immunity Test (EFT(Electrical Fast Transient)내성 시험시 발생되는 전원선 복사 잡음에 관한 연구)

  • 정삼영;이중근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.2
    • /
    • pp.234-241
    • /
    • 2000
  • During the EFT immunity test, the fast transient voltage is injected to the power or signal line. The radiated noise from these lines influences the near-by EUT, and consequently, the reliability of the test result can be jeopardized. The measured data of the field strength and wave shape of the noise were compared with the result of the mathematical analysis using transmission line model. When the tests were performed by the conditions the same as stated in IEC 61000-4-4, the results showed that the magnitude of the radiated electric field strength was about 2.4KV/m, and it can cause severe interference to the intended operation of EUT.

  • PDF

Calculation of the Magnetic Field Homogeneity in the Induction coil for the Magnetic Field Immunity Test (자기장 내성평가용 유도코일의 자기장 균일도 계산)

  • 유권상;김창석
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.5 no.4
    • /
    • pp.64-70
    • /
    • 1994
  • the magnetic field homogeneities of the induction coils of various sizes and shapes were investigated in order to prepare for the magnetic field immunity test under the power frequency, the pulse and the damed oscillatory fields recommended by the IEC. For this purpose, we analyzed the magnetic field homogeneities in the two induction coils with $1m\times1m$, and $1m\times2.6m$, , and the double square coils with 0.8m and 0.6m spaced. The testing volume within $\pm$3dB in the double square coil with 0.8m spaced in twice bigger than single square coil with 1m side in the z-direction.

  • PDF

A Study on the Evaluation Method of Field Uniformity(FU) for Radiated Immunity Test of Vehicle Component (차량용 전장품의 복사내성 평가를 위한 균일장 측정방법에 대한 연구)

  • Yoon, Jae Sang;Hong, Hyun Gwi;Kam, Dong Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.633-636
    • /
    • 2017
  • This thesis is about the evaluation method of field uniformity for radiated immunity test of vehicle component. Radiated immunity test is to find out whether a EUT has enough immunity or hold normal operation during applied electromagnetic interference. Field Uniformity(FU) measurement is essential for generate uniform field on DUT and Harness. But Standard of Radiated Immunity(RI) test for vehicle component based on ISO 11452-2 has not been specified a Field Uniformity(FU). So compared and analyzed with other standard which is defined by a specified a Field Uniformity. As a result, deviation occurs in the difference test condition and test method. In this thesis, proposal new measurement method of field uniformity that is considered test conditions of ISO 11452-2 and check the validity through actual test.

  • PDF

Electromagnetic Field Uniformity Characteristics of a Triangular Reverberation Chamber with Schroeder Diffusers (Schroeder 확산기를 적용한 삼각형 전자파 잔향실의 필드 균일도 특성)

  • 김성철;이중근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.4
    • /
    • pp.373-378
    • /
    • 2002
  • This paper presents the results of an electromagnetic field uniformity of a triangular reverberation chamber that can be used alternatively for analysis and measurement of electromagnetic interference and immunity test. Equilateral triangular reverberation chamber and Schroeder diffusers were designed and fabricated for this purpose. FDTD simulation method was applied to analyze the field distribution inside of two different types of reverberation chambers. As a result, the electromagnetic field uniformity was improved inside of triangular reverberation chambers, and the measured field uniformity was improved by 1 ∼4 ㏈ compared to the ones without diffusers.

A Design of Ferrite Electromagnetic Wave Absorber for Anechoic Chamber (전파무향실용 페라이트 전파흡수체의 설계)

  • 이창우;김동일;김하근
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1998.11a
    • /
    • pp.408-413
    • /
    • 1998
  • Electromagnetic wave absorbers for anechoic chamber are needed to broaden the useful frequency bandwidth, reduce the thickness, and decrease the weight. There are various absorbers proposed for the above conditions, but they could not decisively solve it the alone requirements. The Electromagnetic wave absorber made by a conventional ferrite tile has, for example, broadened the useful frequency bandwidth by the way of forming air layer(practically use urethane foam, etc.) on the ferrite tile. Therefore, an air layer is formed between a reflection plate and a sintered Ni-Zn ferrite tile of 7 mm in thickness, which has reflectivity less than -20 dB from 30 MHz to 600 MHz in bandwidth. Accordingly, in this paper, a broadened electromagnetic wave absorber will be designed, which has the reflection characteristics less than -20 dB from 30 MHz to 6000 MHz in the bandwidth. Then we will design a super broadband electromagnetic wave absorber by inserting square Ferrite Cylinders Type with the thickness less than 11 m and with the frequency band from 30 MHz to 6000 MHz under the above tolerance limits. The purpose of this research is on the development of a universal anechoic chamber for measuring radiated electromagnetic wave or immunity of electronic equipments, GTEM-cell, wall material for prevention TV ghost, etc.

  • PDF

Electromagnetic Field Distribution Analysis on Reverberation Chamber using Electromagnetic Diffusion Method (전자파 확산방식을 이용한 잔향실 내부의 필드 분포 해석)

  • 이광순;이중근;정삼영
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.5
    • /
    • pp.839-848
    • /
    • 2000
  • This paper presents the results of an electromagnetic field analysis for a reverberation chamber that is an alternative method of a shielded anechoic chamber, which is widely used for the analysis and measurement of electromagnetic interference and immunity test. Inside the defined test volume of the rectangular and triangular type, the Schroeder Quadratic Residue Diffuser was employed. FDTD(Finite-Difference Time-Domain) simulation method was applied to produce the field characteristics inside those reverberation chambers. According to the results, field uniformities on the aforementioned two types of reverberation chambers were correlated within $\pm$3dB, and $\pm$4.4dB tolerances, and rectangular type reverberation chamber shows an independent polarization result.

  • PDF

Design of Ferrite Electromagnetic Wave Absorber for Anechoic Chamber (전파무향실용 페라이트 전파흡수체의 설계)

  • 김동일;이창우;김하근;전상엽;정세모
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.1
    • /
    • pp.43-50
    • /
    • 1999
  • Electromagnetic wave absorbers for anechoic chamber are needed to broaden the useful frequency bandwidth, reduce the thickness, and decrease the weight. There are various absorbers proposed for the above conditions, but they could not decisively solve the above requirements. The Electromagnetic wave absorber made by a conventional ferrite tile has, for example, broadened the useful frequency bandwidth by the way of forming air layer. Therefore, an air layer is formed absorber between a reflection plate and a sintered Ni-Zn ferrite tile of 7 mm in thickness, which has reflectivity less than -20 dB from 30 MHz to 450 MHz in frequency band, far narrower than the aimed bandwidth. The purpose of this paper is on the development of a universal anechoic chamber for measuring radiated electromagnetic wave or immunity of electronic equipments, GTEM-cell, wall material for prevention of TV ghost, etc. Accordingly, in this paper, a broadened electromagnetic wave absorber is designed, which has the reflection characteristics less than -20 dB from 30 MHz to 5,430 or 8,000 MHz in the bandwidth. Then we will design a super broadband electromagnetic wave absorber by inserting square Ferrite Cylinders Type with the thickness less than 23.5 m in three-layed type and with the frequency band from 30 MHz to 5,430-8,000 MHz under the above tolerance limits.

  • PDF

Development of Improved EMC Filter for EFT in Power Supply

  • Bae, Dae-Hwan;Kim, Dong-Il;Song, Jae-Man
    • Journal of electromagnetic engineering and science
    • /
    • v.1 no.1
    • /
    • pp.100-104
    • /
    • 2001
  • Since the most of malfunctions in the industrial equipment controlled by processors is consist of the electrical fast transient (EFT)$^{[1],[2]}$TEX>, the International Electrotechnical Commission (IEC) prepared the dummy signal to test the immunity level of the equipments. To work out a countermeasure for the malfunction, We designed a new electromagnetic compatibility (EMC) filter for high power supply, which is consisted of a feed-through capacitor and ferrite materials with high permeability. The ferrite material is surrounded with a power cable or is inserted on the cable’s second layer in order to increase common-mode inductance. We have obtained a excellent insertion loss characteristics over the frequency band from 150 kHz to 30 MHz. The developed new EMC filter satisfy IEC 61000-4-4 and is suitable for industrial, militaly, and medical equipments with reduced malfuntions.

  • PDF

Disturbing Factor Analysis of Radiated Susceptibility Test (전자파내성 시험의 방해 요인 분석)

  • Park, Yoon-hyun;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.76-82
    • /
    • 2016
  • In this paper, EMC (electromagnetic compatibility) test standard KN61000-4-3 "radiated RF electromagnetic field and uniformity chapter immunity test" has been used in, this is the electric field strength to be uniformly applied at the time of the test based on environment to understand the elements of change to analyze the interference factor.

  • PDF

Study on Methods of Missile Electromagnetic Susceptibility (EMS) Test (유도탄 전자기 내성 시험에 대한 고찰)

  • Lee, Dae-Hyun;Oh, TaeckKeun;Oh, Se-kwon;Kim, Hyung-Jae;Park, Dong-Hyun
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.5
    • /
    • pp.423-429
    • /
    • 2020
  • In this paper, the electromagnetic compatibility (EMC) test standard is described, and the purpose and test configuration for the electromagnetic susceptibility (EMS) test of the missile component and the missile system are confirmed. The test configuration and specifications are suggested by the configuration of the missile component and the missile system based on the US military standards MIL-STD-461F and MIL-STD-464C, and explained that the ungrounded state, the final operating state of the missile component and the missile system, was constructed. In addition, the methods for checking the steady state and the points to be considered during the immunity test were introduced.