전자기유량계의 개발및 신호 특성에 관한 연구 (A study on the development of an electromagnetic flowmeter and the characterization of flow signal)

  • 임기원;김창호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.361-364
    • /
    • 2002
  • An electromagnetic flowmeter(EMF) was developed and its characteristics were compared with a commercial EMF. The measuring tube of the EMF was basically designed as 100 m diameter. A signal processing circuit was also developed for generating the magnetic field and converting the flow signal to flowrate and flow quantity. To obtain a more stable and reliable flow signal, the double magnetizing frequency was adopted for magnetizing the coil of the EMF For the characterization of EU, the uncertainty of calibrator was estimated within ${\pm}0.5{\%}$, the method of estimation was in accordance with the ISO 17025 recommendation. It was found that the flow signals between the electrodes were about ${\pm}60\;-\;{\pm}300{\mu}V$, which were sufficient for the discrimination of the flowmeter and protecting the noise. The test result against the calibrator, showed the good linearity in the range of $3 m^{3}/h\;and\;70m^{3}/h$. A commercialized design of the EMF will be technically more competitive in domestic and foreign market.

  • PDF

곡관의 하류에 설치된 전자기유량계의 유량신호 특성에 관한 실험적 연구(난류 유동) (An Experimental Study on Installation Effects of Pipe Elbow on the Electromagnetic Flowmeter Characteristics (Turbulent Flow))

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1613-1621
    • /
    • 2002
  • An electromagnetic flowmeter(EMF) essentially averages the velocity distribution over the pipe cross- sectional area, and the measured value is dependent on the velocity profiles. In this study, installation effects of 90$^{\circ}$long elbow(KS B 1522, ISO 3419) on the EMF characteristics was investigated. A commercial EMF was adopted and the distribution of magnetic field in the electrodes cross section was measured. In the experiment, the national flow standard system, of which measurement uncertainty was evaluated in accordance with ISO 17025 recommendation, was used fur characterization of EMF. The leading line has 150D long straight pipe to established a fully developed flow before entering into the elbow and the elbow was installed downstream of it. then the flowmeter was tested within 50 D from the elbow. The installation effects of the flowmeter were investigated by varying the mean velocity(Reynolds No.)in pipe section, the locations and the direction of electrodes plane.($\phi$) From the experimental results, we find the optimal conditions to get most accurate measurements. Generally, the deviations from the calibration value were less than 0.5 % in farther than 10D distance from the elbow and the direction of electrode plane. $\phi$ = 90$^{\circ}$yielded the smallest measurement deviation. These characteristics were shown consistently in turbulent region regardless of the mean Reynolds number.

2상류용 전류형식 전자기유량계 이론 및 환상류에서의 3차원 가상포텐셜 분포의 수치적 계산 (Theory of a Current-Type Electromagnetic Flowmeter for Two-Phase Flow and Numerical Computation of the 3D Virtual Potential Distributions for Annular Flow)

  • 오병도;김무환;안예찬
    • 대한기계학회논문집B
    • /
    • 제27권6호
    • /
    • pp.714-725
    • /
    • 2003
  • The theory of the current-type electromagnetic flowmeter for a high temporal resolution was developed for two-phase flow measurements. To predict the output of the current-type flowmeter, the three-dimensional virtual potential distribution C and the newly introduced flow pattern coefficient f were derived and computed. The output of flowmeter depends on the liquid conductivity (sensitive to temperature) and flow configurations of the two-phase flow with the sinusoidal excitation over 100 Hz. The flow pattern coefficient was specially devised to separate the dependency on the flow configuration of the two-phase flow from that on the liquid conductivity which can be expressed with the calibration of single-phase flow. Using the finite difference method, the three-dimensional virtual potential distributions were computed for the electrode of finite size. By taking derivative of the virtual potential, the weight functions were evaluated and compared with existing analytic series solution for the point-electrode. There was a reasonable correspondence between the present and existing results. In addition, the flow pattern coefficients were evaluated for annular flows with various film thicknesses, and compared with the experimental results by the impedance spectroscopy. The numerical results agreed well with the experimental data.

2개의 기준유량계를 이용한 유량계 교정장치의 측정불확도 평가에 관한 연구 (A Study on the Uncertainty Estimation of Flowmeter Calibrator with Two Master Flowmeters)

  • 최종오;이완규;임기원
    • 대한기계학회논문집B
    • /
    • 제28권10호
    • /
    • pp.1219-1230
    • /
    • 2004
  • Comparing to the gravimetric and volumetric method, the flowmeter calibration based on the master meter method is relatively economical and convenient, especially for high flowrate. The uncertainty of flow quantity and flowrate using the master meter method was evaluated according to the GUM (Guide to the Expression of Uncertainty in Measurement). In order to apply for the wider flow range, two master meters (electromagnetic flow meter) were employed as reference flowmeters. The uncertainty of the master meter was obtained by combining the statistical variation of the repeated measurements and the variation of fluid density and pipe material due to temperature and pressure changes were scrutinized. for a practical application, the uncertainty of calibrator, whose measuring capacity of 1000 ㎥/h obtained by employing two 500 ㎥/h electromagnetic How meters, was evaluated. The uncertainty budget shows the quantitative contribution of each uncertainty component to the overall uncertainty of the calibrator. As a result, it was found that the dominant uncertainties were from the master meter, which was evaluated statistically, and from the process of least squares fitting. On the contrary, the uncertainties arising from the variation of the fluid density and the pipe volume due to the temperature and pressure were negligible.

Signal processing method of bubble detection in sodium flow based on inverse Fourier transform to calculate energy ratio

  • Xu, Wei;Xu, Ke-Jun;Yu, Xin-Long;Huang, Ya;Wu, Wen-Kai
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3122-3125
    • /
    • 2021
  • Electromagnetic vortex flowmeter is a new type of instrument for detecting leakage of steam generator, and the signal processing method based on the envelope to calculate energy ratio can effectively detect bubbles in sodium flow. The signal processing method is not affected by changes in the amplitude of the sensor output signal, which is caused by changes in magnetic field strength and other factors. However, the detection sensitivity of the electromagnetic vortex flowmeter is reduced. To this end, a signal processing method based on inverse Fourier transform to calculate energy ratio is proposed. According to the difference between the frequency band of the bubble noise signal and the flow signal, only the amplitude in the frequency band of the flow signal is retained in the frequency domain, and then the flow signal is obtained by the inverse Fourier transform method, thereby calculating the energy ratio. Using this method to process the experimental data, the results show that it can detect 0.1 g/s leak rate of water in the steam generator, and its performance is significantly better than that of the signal processing method based on the envelope to calculate energy ratio.

미소 유량 측정을 위한 마이크로 전 유량계의 제작 (Fabrication of a Micro Magnetic Flowmeter for Micro Flow Rate Measurement)

  • 윤현중;김근영;정옥찬;양상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3268-3270
    • /
    • 1999
  • This paper presents the fabrication of a micro electromagnetic flowmeter for liquid flow rate measurement. The flowmeter consists of a silicon flow channel with two electrodes and two permanent magnets. The micro flow channel and the detection electrodes are fabricated by the anisotropic etching of two silicon substrates and the metal evaporation process respectively. If conductive fluid passes through a magnet field, electromotive force is generated and detected by two electrodes. When the flow rate is 2.6 ml/sec, the measured output voltage is 7.4 mV.

  • PDF

저전도율 유체 측정에서 소형 전자기유량계의 신호 특성 (Flow Signal Characteristics of Small Scale Electromagnetic Flowmeter in Low Conductivity Fluid Measurement)

  • 임기원;정성수
    • 대한기계학회논문집B
    • /
    • 제40권9호
    • /
    • pp.613-620
    • /
    • 2016
  • 유체의 전도율(conductivity)이 전자기유량계의 특성에 미치는 영향을 평가하기 위해 소형 전자기 유량계를 설계 제작하였다. 유량계의 측정관(measuring tube)은 $4mm{\times}3mm$의 직사각형 단면을 가지며 길이는 9 mm이다. 전극은 직경이 1.5 mm인 점전극과 단면이 $2mm{\times}3mm$인 면전극으로 설계하였다. 코일의 열 발생에 영향을 미치는 자화주파수, 회전수 및 굵기를 변화시키면서 최적값을 찾았다. 최적화된 측정관은 자속밀도(magnetic flux density) 0.04 T (400 gauss)를 발생시키며 안정되고, 선형적인 유량신호를 얻을 수 있었다. 유량계를 특성을 평가하기 위해 중량식 유량계 교정 장치를 제작하였다. 유동율 범위는 최대 $1.17{\times}10^{-5}m^3/s$(700 cc/min)이며 ISO규격에 따라 유동량 결정의 불확도를 평가하였으며 크기는 0.06 % 이내이었다. 유체의 전도율은 $3-11{\mu}S/cm$ 사이에서 조절하였다.

Signal processing method based on energy ratio for detecting leakage of SG using EVFM

  • Xu, Wei;Xu, Ke-Jun;Yan, Xiao-Xue;Yu, Xin-Long;Wu, Jian-Ping;Xiong, Wei
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1677-1688
    • /
    • 2020
  • In the sodium-cooled fast reactor, the steam generator is a heat exchange device between sodium and water, which may cause leakage, resulting in a sodium-water reaction accident, which in turn affects the safe operation of the entire nuclear reactor. To this end, the electromagnetic vortex flowmeter is used to detect leakage of the steam generator and its signal processing method is studied in this paper. The hydraulic experiment was carried out by using water instead of liquid sodium, and the sensor output signal of the electromagnetic vortex flowmeter under different gas injection volumes was collected. The bubble noise signal is reflected by the base line of the sensor output signal. According to the relationship between the proportion of the bubble noise signal in the sensor output signal and the gas injection volume, a signal processing method based on the energy ratio calculation is proposed to detect whether the water contains bubbles. The gas injection experiment of liquid sodium was conducted to verify the effectiveness of the signal processing method in the detection of bubbles in sodium, and the minimum detectable leak rate of water in the steam generator was detected to be 0.2 g/s.

방류수 유량계(전자기유량계, 파샬플룸)의 특성평가 연구 (A Study on Comparison of the Characteristic Test of Discharge Water Flowmeters (Electromagnetic Flowmeter, Parshall Flume))

  • 안양기;김지영;김금희;장희수;정정필;최종우
    • 한국유체기계학회 논문집
    • /
    • 제18권6호
    • /
    • pp.57-62
    • /
    • 2015
  • The test of comparing liquid flow calibration system (approved by KOLAS) for accuracy and structure change test was performed in the test bed in order to evaluate the typical characteristics of the electromagnetic flow meters and parshall flume that are generally used in the water discharging facilities. The results of the accuracy comparing test with liquid flow calibration system showed the error of less than 2%. Pharshall plume got error up to -8.3% (low flow) from the flow rate test, but less than 4% from the accumulated flow test because of offset error at high flow rate and low flow rate. Evaluation of structual change test was tested with only parshall flume using structure and it consisted of installation angle (parshall flume and level sensor) and position change. Installation angle, water level sensor angle and position changing test for parshall flume had errors of 3.1%~-9.2%, 0.4%~-5.6% and 0.2%~1.3% respectively. Especially, the error showed the largest increase when the water level sensor measured the point of decreased flow by the structure change. Therefore, error factors (change of straight pipe length, installation of obstacle or effect of foreign substances on water level sensor) that can often occur in the field should be derived and the research for optimized installation method should be carried out continuously.