• Title/Summary/Keyword: Electromagnetic Field

Search Result 1,869, Processing Time 0.029 seconds

Influence of Frequency on Electromagnetic Field of Super High-Speed Permanent Magnet Generator

  • Qiu, Hongbo;Wei, Yanqi;Wang, Wei;Tang, Bingxia;Zhao, Xifang;Yang, Cunxiang
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.980-988
    • /
    • 2019
  • When compared with traditional power frequency generators, the frequency of a super high-speed permanent magnet generator (SHSPMG) is a lot higher. In order to study the influence of frequency on the electromagnetic field of SHSPMGs, a 60000rpm, 117kW SHSPMG was taken as a research object. The two-dimensional finite element model of the generator was established, and the two-dimensional transient field of the generator was simulated. In addition, a test platform of the generator was set up and tested. The reliability of the simulation was verified by comparing the experiment data with that of the simulation. Then the generator electromagnetic field under different frequencies was studied, and the influence mechanism of frequency on the generator electromagnetic field was revealed. The generator loss, voltage regulation rate, torque and torque ripple were analyzed under the rated active power load and different frequencies. The influences of frequency on the eddy current density, loss, voltage regulation rate and torque ripple of the generator were obtained. These conclusions can provide some reference for the design and optimization of SHSPMGs.

Analysis of Electromagnetic Field by moving metal particle in GIS using SNM (공간회로망법을 이용한 GIS내의 움직이는 도체이물질에 대한 전자계 해석)

  • Lim, Y.L.;Park, K.S.;Choi, Y.L.;Choi, C.Y.;Ko, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1670-1672
    • /
    • 2001
  • In compared with air insulated switchgear GIS has a high efficiency and confidence. Insulation method using $SF_6$ gas has a very excellent insulation characteristics for high voltage equipment but has a characteristics that insulation heredity is changed for internal unequal electric field. So analysis of electromagnetic field in GIS is very important basic data for structure design and trouble diagnosis process. In compared with established method, SNM in this paper observes variation of the electromagnetic field with real time and get result very similar to measurement. In order to know the variation of electromagnetic field distribution for transient response for time and position, variations are observed when metal particles are moving fast.

  • PDF

The Calculation of Two Dimensional Spatial Profile of Electromagnetic Field for Capacitively Coupled Plasma Source (축전 결합형 플라즈마원에 대한 전자기장의 2차원 공간 의존성 계산)

  • Kim, Y.I.;Yoon, N.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.5
    • /
    • pp.400-407
    • /
    • 2008
  • In this study, Two dimensional spatial profile of electromagnetic field for capacitively coupled plasma source is calculated. Based on one dimensional fluid equation, spatial profile for the axial direction of electric field and conduction current density is firstly calculated. The two dimensional spatial profile for the electromagnetic field is calculated from solution of Maxwell equation that is expanded to power series for ${\omega}r/c$ into the radial direction.

Development of concrete pumping technology for construction of high-rise building using electromagnetic field (전자기장을 활용한 초고층 건축물 콘크리트 압송기술개발)

  • Kim, Woo-Jea;Kwon, Seung-Hee
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.4-5
    • /
    • 2018
  • Recently, high-strength concrete used for shortening the construction time of high-rise building construction, Concrete pumping technology is emerging as the core technology of high-rise buildings. In this paper, we have started to study the use of electromagnetic field as a method to increase the efficiency of the lubricating layer between the inside of the pipe and concrete, which has been established as the most important factor determining the pumping performance. The pumping performance improvement effect of concrete strength was verified and basic research was carried out to utilize it as a method to increase the efficiency of pumping in field application. In the related work, the effect of the electromagnetic field was verified by conducting a mock-up performance evaluation (horizontal 300 m) of the pumping force by the concrete strength.

  • PDF

Analysis of Unequal Electric Field by Moving Metal Particle in GIS Using SNM (공간회로망법을 이용한 GIS 내부의 움직이는 도체이물질에 의한 불평등전계 해석)

  • Park, Gyeong-Su;Choe, Seong-Yeol;Go, Yeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.2
    • /
    • pp.68-73
    • /
    • 2002
  • In compared with air insulated switchgear, GIS has a high efficiency and confidence. Insulation method using $SF_6$ gas has a very excellent insulation characteristic for high voltage equipment but has a characteristic that insulation heredity is changed for internal unequal electric field. So analysis of time varying electromagnetic field in GIS is very important for structure design and trouble diagnosis process. In compared with established method, the SNM(Spatial Network Method) in this Paper can observe variation of electromagnetic field with real time and get result very similar to measurement. In order to Know variation of electromagnetic field distribution in fast moving particle, we make used of SNM.

Numerical analysis of electromagnetic fields in the trailer car of high speed train by transmission line matrix method (TLM 방법을 이용한 고속열차내의 객차 내부의 전자기장 해석)

  • Han, In-Su;Lee, Tae-Hyung;Park, Choon-Soo;Kim, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.403-406
    • /
    • 2009
  • Recently, electricity is essential for human lives. Modem people take cultural benefits due to the development of the electric power system and the spread of the high tech-electric appliances, the cell phones, and etc. However, the electromagnetic field problems become prominent figures owing to the fault of the communication devices around the power line and the biological effect, and etc. In this paper, we introduce the simple electromagnetic field calculation based on the transmission line matrix method, prior to the analysis about the influence of electromagnetic field. Simulation object is the inner part of the trailer car in the high speed train. Unlike the existing paper we submitted, we analyze not only the magnetic field but the electric field in the inner part of the trailer car which makes up the high speed train.

  • PDF

Electric Field Uniformity in Reverberation Chamber with 5 GHz Diffuser by Transmission Antenna (송신 안테나에 의한 5 GHz 이차 잔류 디퓨저를 적용한 전자파 잔향실의 내부 필드 균일도 변화)

  • Rhee, Eugene
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.3
    • /
    • pp.83-86
    • /
    • 2021
  • In this paper, electric fields in electromagnetic reverberation chambers, which are used as a substitute facility for EM-free anechoic chambers, are analyzed. This paper focused on the 4-5 GHz band, which is expected to adversely affect equipment. To analyze the field uniformity inside the electromagnetic reverberation chamber, electric field strengths are sampled and finite-difference time-domain method was used for numerical analysis. Moreover, Quadratic residue diffuser was used to improve the characteristics of the electromagnetic reverberation chamber and the uniformity of the internal field strength. Standard deviation, tolerance characteristics, and partiality characteristics were compared while varying the aiming point of transmission antenna.

Electromagnetic Field Distribution Analysis on Reverberation Chamber using Electromagnetic Diffusion Method (전자파 확산방식을 이용한 잔향실 내부의 필드 분포 해석)

  • 이광순;이중근;정삼영
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.5
    • /
    • pp.839-848
    • /
    • 2000
  • This paper presents the results of an electromagnetic field analysis for a reverberation chamber that is an alternative method of a shielded anechoic chamber, which is widely used for the analysis and measurement of electromagnetic interference and immunity test. Inside the defined test volume of the rectangular and triangular type, the Schroeder Quadratic Residue Diffuser was employed. FDTD(Finite-Difference Time-Domain) simulation method was applied to produce the field characteristics inside those reverberation chambers. According to the results, field uniformities on the aforementioned two types of reverberation chambers were correlated within $\pm$3dB, and $\pm$4.4dB tolerances, and rectangular type reverberation chamber shows an independent polarization result.

  • PDF

Estimation of MCG parameters for the diagnosis of heart diseases (심질환 진단을 위한 심자도 파라메터의 추출)

  • Jeon, Chang-Ik;Huh, Young;Kim, Ki-Uk;Han, Byung-Hee;Jin, Seung-Oh;Chang, Won-Suk;Lee, Hyun-Ho
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.549-552
    • /
    • 2003
  • The electrical current generated by heart creates not only electric potential but also a magnetic field. We have observed electrophysiological phenomena of the heart by measuring tangential components of magnetocardiogram(MCG) using 61 channel superconducting quantum interference device(SQUD) system. In this paper, we developed a new analysis method, which is based on the theory of electromagnetic field. We show some differences of the current direction between the normal MCG and the abnormal(ischemic heart disease) MCG.

  • PDF

Evaluation of Electromagnetic Shielding Efficiency of Magnetite-Carbon based Inorganic Paint (Magnetite-Carbon계 전자파흡수 무기도료의 현장 전자파 저감 성능 평가)

  • Park, Dong-Cheol;Lee, Se-Hyoen;Song, Tae-Hyeop;Sim, Jong-Woo;Park, Jae-Myoung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.141-144
    • /
    • 2004
  • Nowadays, there has been substantial interest in whether there is an association between electromagnetic field exposure and living environment. It is increased the demand that electromagnetic wave environment and its countermeasure. In the present study, we has applied the electromagnetic absorbent inorganic paint of 'I' corporations, and measured electromagnetic waves generated in new apartment before occupancy using the standard field electromagnetic wave generating device we developed. The measurement before occupancy was $100\~131V/m$, but the measurement after occupancy was $6.9\~8.0V/m$ less than 10V/m, the comprehensive electromagnetic wave limit allowed by TCO in Sweden. The implication is that domestic apartment are exposed to extremely poor electromagnetic wave environment. Nevertheless, there have been neither serious efforts to overcome this problem, nor its alternatives and related standards. Therefore, it is necessary to continue research of related fields to establish standards and plans to improve the situation.

  • PDF