• 제목/요약/키워드: Electromagnetic Field

검색결과 1,870건 처리시간 0.041초

Dual effect of Low- frequency Electromagnetic Field on Muscle Histopathology of Caspian Sea Cyprinus carpio

  • Samiee, Farzaneh;Samiee, Keivandokht
    • 한국어병학회지
    • /
    • 제30권1호
    • /
    • pp.51-61
    • /
    • 2017
  • The effect of electromagnetic field on aquatic organisms has received little attention. In the current study, the effect of 50Hz electromagnetic field on muscle histopathology of Caspian Sea Cyprinus carpio, a species of economic importance, was investigated. A total of 120 healthy fish were used in this study. They were classified randomly in one of two groups as follows: Control or unexposed EMF group and experimental group with 5 different magnetic field intensities (0.1, 1, 3, 5 and 7mT) at 2 different exposure times including 30 and 60 minutes. Fish in the experimental group were exposed only once. Two weeks after exposure, dorsal muscles sectioned transversely, stained and were examined using a light microscope. Histopathologic assessments showed significant difference between control and EMF exposed groups at both 30 min. (p<0.01) and 60 min. (p<0.001) exposure times. We report for the first time that electromagnetic field in interaction with muscular tissue of Cyprinus carpio exhibits a dual effect which depends on the field intensity, and exposure time. At short exposure time (30 min.), EMF stimulates muscle growth process. At longer exposure time (60 min.), EMF can damage muscle tissue and result in muscle necrosis. More research is required to elucidate precise mechanisms involved in muscle hypertrophy and pathologic changes.

Electromagnetic Field Analysis on Surge Response of 500 kV EHV Single Circuit Transmission Tower in Lightning Protection System using Neural Networks

  • Jaipradidtham, Chamni
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1637-1640
    • /
    • 2005
  • This paper presents a technique for electromagnetic field analysis on surge response due to Mid-span back-flashovers effects in lightning protection system of 500 kV EHV single circuit transmission tower by the neural networks method. These analyses are based on modeling lightning return stroke as well as on coupling the electromagnetic fields of the stroke channel to the line. The ground conductivity influences both the electric field as well as the coupling mechanism and hence the magnitude and wave shape of the induced voltage. The technique can be used to analyzed the corona voltage effect, the effective of stroke to the span tower, the surge impedance of transmission lines. The maximum voltage from flashovers effects in the lines. The model is compatible with general electromagnetic transients programs such as the ATP-EMTP. The simulation results show that this study analyses for time-domain with those produced by a cascade multi-section model, the surge impedance of a full-sized tower hit directly by a lightning stroke is discussed.

  • PDF

전기자장에 의한 혼상류의 제어에 관한 수치해석 (Numerical Analysis on the Control of Particle-laden Flow Using Electromagnetic Field)

  • 남성원;신산신일
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1996년도 춘계 학술대회논문집
    • /
    • pp.125-130
    • /
    • 1996
  • A numerical analysis is conducted on heat transfer and fluid flow of a plasma spraying process under the DC-RE hybrid electromagnetic field. Plasma flow is analyzed by using Eulerian approach and the equation of particle motion is simultaneously solved using a trajectory analysis with a lumped-heat-capacity model. Axisymmetric two dimensional electromagnetic fields governed by Maxwell's equations are solved based on a vector potential concept. The effects of the RF electromagnetic field on the temperature and velocity fields of the turbulent plasma flow are clarified. Control characteristics of phase changes and dispersed features of particles by applying the RF electromagnetic field are also clarified in an attempt to improve the plasma spraying process

  • PDF

Schroeder 확산기를 적용한 삼각형 전자파 잔향실의 필드 균일도 특성 (Electromagnetic Field Uniformity Characteristics of a Triangular Reverberation Chamber with Schroeder Diffusers)

  • 김성철;이중근
    • 한국전자파학회논문지
    • /
    • 제13권4호
    • /
    • pp.373-378
    • /
    • 2002
  • 본 논문은 전자파 장해 및 복사 내성 측정의 대용시설로 사용될 수 있는 삼각형 구조의 전자파 잔향실내 필드 균일도 특성에 관한 연구이다. 체적이 동일한 두 삼각형 구조의 전자파 잔향실내 필드 균일도를 개선시키기 위하여 Schroeder 확산기를 설계하여 적용하였으며, 잔향실 내부의 필드 특성을 해석하기 위해 FDTD (Finite-Difference Time-Domain)방법 을 사용하여 시험 공간의 한 면에 서 전계 세기를 추출한 후, 필드 분포를 분석하였다. 또한 정삼각형 구조의 전자파 잔향실과 Schroeder 확산기를 설계, 시뮬레이션 및 제작하여, 실험을 통한 시험 평가를 한 결과, Schroeder 확산기를 적용한 삼각형 구조의 전자파 잔향실내 필드 균일도가 확산기를 적용하지 않은 경우와 비교하여 1 ~4 ㏈ 개선됨을 알 수 있었다.

Study of statistical distribution for four-port TEM cell

  • Jeon, Sangbong;Kwon, Jong-Hwa
    • Journal of Multimedia Information System
    • /
    • 제1권2호
    • /
    • pp.127-132
    • /
    • 2014
  • The transverse electromagnetic (TEM) cells are widely used for electromagnetic compatibility (EMC) testing and field probe calibrations. We propose the verification of TEM mode with statistical method using a four-port TEM cell. The verification results are compared with Normal, Rayleigh, and Gamma distribution. As a result, the 75 % quantile of the Rayleigh distribution is excellent agreement with the true quantiles for a number of calibration points.

  • PDF

전기철도의 전자기적합성에 관한 고찰 (Study for electromagnetic compatibility of electric train system)

  • 김민철;이장무;한문섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.883-888
    • /
    • 2005
  • In modern system, electromagnetic environment are going worse with advancing electric and electronic technology, and this electromagnetic environment affect modern electric train system at the point of the safety problem. Therefore, each distributed system that is consisting electric train system have to prove there own electromagnetic compatibility through the field test. These distributed system can be considered as power supply system, signal & communication system and train system. In this study, essential field tests for electromagnetic compatibility of train system based on IEC national standard are suggested.

  • PDF

저항시트 장하에 의한 슬릿 침투 전자파의 저감 특성 (REDUCTION CHARACTERISTICS Of ELECTROMAGNETIC PENETRATION THROUGH MARROW SLOTS BY RESISTIVE SHEETS LOADING)

  • 박은정;주창현;김기채
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.433-436
    • /
    • 2005
  • This paper presents the reduction methods of penetrated electromagnetic fields through a narrow slot aperture in a planar conducting screen of infinite extent. When a plane wave is excited to the narrow slot, the aperture electric field is controlled by the resistive sheets loaded on the slot. The magnitude of penetrated electromagnetic fields through a narrow slot is controlled by electric field distributions on the slot aperture. The results show that the magnitude of the penetrated electromagnetic field can be effectively reduced by the resistive sheets on the slot aperture.

  • PDF

EMI/EMC 환경에서 PCB와 Frame구조물의 전자기 방사특성 해석 (Numerical Analysis of Electromagnetic Radiation Characteristic of PCB and Frame Structure in EMI/EMC)

  • 최윤석;김영선;황보훈;박일한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.715-716
    • /
    • 2006
  • Nowadays, research of EMI/EMC is very important in electromagnetic wave surroundings generated from many electric and electronic devices. Especially, analysis of electromagnetic radiation characteristic and field have to be performed first of all. At the present most of EMI/EMC problems are solved by the method of practice and inspiration. Hence in this paper, will provide the first step for solving EMI/EMC problems in design process. Model of analysis is structure composed of PCB and Frame. By the first step, theory of dipole antenna is adapted to analyze electromagnetic radiation characteristic and field. Because it is fundamental of analysis of electromagnetic radiation. And it will be expanded for structure of PCB and Frame. Finally, it provide the basic method of analysis of electromagnetic radiation characteristic and field by making similar dipole antenna to PCB and Frame structure.

  • PDF

FEM/EMTP를 이용한 GIS내 부분방전 펄스의 감쇠특성 해석 (Analysis of Partial Discharge Signal Propagation Characteristics in GIS Using FEM/EMTP)

  • 이도훈;이현동;신양섭;이용희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.255-257
    • /
    • 2004
  • This paper was studied electromagnetic field distribution and damping of PD(Partial Discharge) signal in GIS(Gas Insulated Switchgear). Cut-off frequency of electromagnetic wave propagation modes were computed, electromagnetic field distribution of propagation modes in GIS by FEM(Finite Element Method) were simulated and simulated damping characteristic of electromagnetic waves in GIS by EMTP(Electromagnetic Transient Program) when generated PD pulse. Frequency band of $TE_{mn}/TM_{mn}$ modes were determinated by simulation results of electromagnetic field distribution and were discussed optimal position of UHF sensor from this results. Equivalent circuit was used to simulate signal damping of PD pulse in GIS by EMTP and compared with measured results in laboratory of KERI.

  • PDF

의료기관 내 전자파 환경 (Electromagnetic Fields in General Hospital)

  • 신세원;윤상모;신현진;안현수;안희덕
    • Journal of Yeungnam Medical Science
    • /
    • 제21권2호
    • /
    • pp.167-176
    • /
    • 2004
  • Background: Electromagnetic fields (EMF) are ubiquitous in modern society including medical field. As the technology of medical instruments and telecommunications has developed rapidly, it has influenced on our lives in many ways. Modern medical practice requires high quality medical equipments, which have a great deal of electromagnetic interference and susceptibility. The purpose of this study were to evaluate electromagnetic condition under usual clinical condition and to suggest a practical guideline in general hospital. Materials and Methods: The actual state of the electromagnetic interference in the medical field was studied under usual clinical conditions including operating rooms, intensive care units, magnetic resonance imaging unit, and hyperthermia unit. Results: There was considerable noise as a result of electromagnetic fields from medical equipments including electrosurgical units and hyperthermia unit, and cellular phones, which could induce serious functional derangements of functioning medical devices. Conclusion: It will be necessary to evaluate the individual electromagnetic situations under various medical conditions and to define a limited zone for cellular phone as well as reposition medical equipments to secure a safer medical practice and to minimize electromagnetic interference.

  • PDF