• Title/Summary/Keyword: Electromagnetic Field

Search Result 1,871, Processing Time 0.031 seconds

Dual effect of Low- frequency Electromagnetic Field on Muscle Histopathology of Caspian Sea Cyprinus carpio

  • Samiee, Farzaneh;Samiee, Keivandokht
    • Journal of fish pathology
    • /
    • v.30 no.1
    • /
    • pp.51-61
    • /
    • 2017
  • The effect of electromagnetic field on aquatic organisms has received little attention. In the current study, the effect of 50Hz electromagnetic field on muscle histopathology of Caspian Sea Cyprinus carpio, a species of economic importance, was investigated. A total of 120 healthy fish were used in this study. They were classified randomly in one of two groups as follows: Control or unexposed EMF group and experimental group with 5 different magnetic field intensities (0.1, 1, 3, 5 and 7mT) at 2 different exposure times including 30 and 60 minutes. Fish in the experimental group were exposed only once. Two weeks after exposure, dorsal muscles sectioned transversely, stained and were examined using a light microscope. Histopathologic assessments showed significant difference between control and EMF exposed groups at both 30 min. (p<0.01) and 60 min. (p<0.001) exposure times. We report for the first time that electromagnetic field in interaction with muscular tissue of Cyprinus carpio exhibits a dual effect which depends on the field intensity, and exposure time. At short exposure time (30 min.), EMF stimulates muscle growth process. At longer exposure time (60 min.), EMF can damage muscle tissue and result in muscle necrosis. More research is required to elucidate precise mechanisms involved in muscle hypertrophy and pathologic changes.

Electromagnetic Field Analysis on Surge Response of 500 kV EHV Single Circuit Transmission Tower in Lightning Protection System using Neural Networks

  • Jaipradidtham, Chamni
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1637-1640
    • /
    • 2005
  • This paper presents a technique for electromagnetic field analysis on surge response due to Mid-span back-flashovers effects in lightning protection system of 500 kV EHV single circuit transmission tower by the neural networks method. These analyses are based on modeling lightning return stroke as well as on coupling the electromagnetic fields of the stroke channel to the line. The ground conductivity influences both the electric field as well as the coupling mechanism and hence the magnitude and wave shape of the induced voltage. The technique can be used to analyzed the corona voltage effect, the effective of stroke to the span tower, the surge impedance of transmission lines. The maximum voltage from flashovers effects in the lines. The model is compatible with general electromagnetic transients programs such as the ATP-EMTP. The simulation results show that this study analyses for time-domain with those produced by a cascade multi-section model, the surge impedance of a full-sized tower hit directly by a lightning stroke is discussed.

  • PDF

Numerical Analysis on the Control of Particle-laden Flow Using Electromagnetic Field (전기자장에 의한 혼상류의 제어에 관한 수치해석)

  • NAM Seong-Won;KAMIYAMA Shin-icki
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1996.05a
    • /
    • pp.125-130
    • /
    • 1996
  • A numerical analysis is conducted on heat transfer and fluid flow of a plasma spraying process under the DC-RE hybrid electromagnetic field. Plasma flow is analyzed by using Eulerian approach and the equation of particle motion is simultaneously solved using a trajectory analysis with a lumped-heat-capacity model. Axisymmetric two dimensional electromagnetic fields governed by Maxwell's equations are solved based on a vector potential concept. The effects of the RF electromagnetic field on the temperature and velocity fields of the turbulent plasma flow are clarified. Control characteristics of phase changes and dispersed features of particles by applying the RF electromagnetic field are also clarified in an attempt to improve the plasma spraying process

  • PDF

Electromagnetic Field Uniformity Characteristics of a Triangular Reverberation Chamber with Schroeder Diffusers (Schroeder 확산기를 적용한 삼각형 전자파 잔향실의 필드 균일도 특성)

  • 김성철;이중근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.4
    • /
    • pp.373-378
    • /
    • 2002
  • This paper presents the results of an electromagnetic field uniformity of a triangular reverberation chamber that can be used alternatively for analysis and measurement of electromagnetic interference and immunity test. Equilateral triangular reverberation chamber and Schroeder diffusers were designed and fabricated for this purpose. FDTD simulation method was applied to analyze the field distribution inside of two different types of reverberation chambers. As a result, the electromagnetic field uniformity was improved inside of triangular reverberation chambers, and the measured field uniformity was improved by 1 ∼4 ㏈ compared to the ones without diffusers.

Study of statistical distribution for four-port TEM cell

  • Jeon, Sangbong;Kwon, Jong-Hwa
    • Journal of Multimedia Information System
    • /
    • v.1 no.2
    • /
    • pp.127-132
    • /
    • 2014
  • The transverse electromagnetic (TEM) cells are widely used for electromagnetic compatibility (EMC) testing and field probe calibrations. We propose the verification of TEM mode with statistical method using a four-port TEM cell. The verification results are compared with Normal, Rayleigh, and Gamma distribution. As a result, the 75 % quantile of the Rayleigh distribution is excellent agreement with the true quantiles for a number of calibration points.

  • PDF

Study for electromagnetic compatibility of electric train system (전기철도의 전자기적합성에 관한 고찰)

  • Kim Min-Cheol;Lee Jang-Mu;Han Moon-Soeb
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.883-888
    • /
    • 2005
  • In modern system, electromagnetic environment are going worse with advancing electric and electronic technology, and this electromagnetic environment affect modern electric train system at the point of the safety problem. Therefore, each distributed system that is consisting electric train system have to prove there own electromagnetic compatibility through the field test. These distributed system can be considered as power supply system, signal & communication system and train system. In this study, essential field tests for electromagnetic compatibility of train system based on IEC national standard are suggested.

  • PDF

REDUCTION CHARACTERISTICS Of ELECTROMAGNETIC PENETRATION THROUGH MARROW SLOTS BY RESISTIVE SHEETS LOADING (저항시트 장하에 의한 슬릿 침투 전자파의 저감 특성)

  • Park, Eun-Jung;Ju, Chang-Hyun;Kim, Ki-Chai
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.433-436
    • /
    • 2005
  • This paper presents the reduction methods of penetrated electromagnetic fields through a narrow slot aperture in a planar conducting screen of infinite extent. When a plane wave is excited to the narrow slot, the aperture electric field is controlled by the resistive sheets loaded on the slot. The magnitude of penetrated electromagnetic fields through a narrow slot is controlled by electric field distributions on the slot aperture. The results show that the magnitude of the penetrated electromagnetic field can be effectively reduced by the resistive sheets on the slot aperture.

  • PDF

Numerical Analysis of Electromagnetic Radiation Characteristic of PCB and Frame Structure in EMI/EMC (EMI/EMC 환경에서 PCB와 Frame구조물의 전자기 방사특성 해석)

  • Choi, Yoon-Seok;Kim, Young-Sun;HwangBo, Hoon;Park, Il-Han
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.715-716
    • /
    • 2006
  • Nowadays, research of EMI/EMC is very important in electromagnetic wave surroundings generated from many electric and electronic devices. Especially, analysis of electromagnetic radiation characteristic and field have to be performed first of all. At the present most of EMI/EMC problems are solved by the method of practice and inspiration. Hence in this paper, will provide the first step for solving EMI/EMC problems in design process. Model of analysis is structure composed of PCB and Frame. By the first step, theory of dipole antenna is adapted to analyze electromagnetic radiation characteristic and field. Because it is fundamental of analysis of electromagnetic radiation. And it will be expanded for structure of PCB and Frame. Finally, it provide the basic method of analysis of electromagnetic radiation characteristic and field by making similar dipole antenna to PCB and Frame structure.

  • PDF

Analysis of Partial Discharge Signal Propagation Characteristics in GIS Using FEM/EMTP (FEM/EMTP를 이용한 GIS내 부분방전 펄스의 감쇠특성 해석)

  • Lee, D.H.;Lee, H.D.;Sin, Y.S.;Lee, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.255-257
    • /
    • 2004
  • This paper was studied electromagnetic field distribution and damping of PD(Partial Discharge) signal in GIS(Gas Insulated Switchgear). Cut-off frequency of electromagnetic wave propagation modes were computed, electromagnetic field distribution of propagation modes in GIS by FEM(Finite Element Method) were simulated and simulated damping characteristic of electromagnetic waves in GIS by EMTP(Electromagnetic Transient Program) when generated PD pulse. Frequency band of $TE_{mn}/TM_{mn}$ modes were determinated by simulation results of electromagnetic field distribution and were discussed optimal position of UHF sensor from this results. Equivalent circuit was used to simulate signal damping of PD pulse in GIS by EMTP and compared with measured results in laboratory of KERI.

  • PDF

Electromagnetic Fields in General Hospital (의료기관 내 전자파 환경)

  • Shin, Sei-One;Yun, Sang-Mo;Shin, Hyoun-Jin;Ahn, Hyun-Soo;Ahn, Hee-Deok
    • Journal of Yeungnam Medical Science
    • /
    • v.21 no.2
    • /
    • pp.167-176
    • /
    • 2004
  • Background: Electromagnetic fields (EMF) are ubiquitous in modern society including medical field. As the technology of medical instruments and telecommunications has developed rapidly, it has influenced on our lives in many ways. Modern medical practice requires high quality medical equipments, which have a great deal of electromagnetic interference and susceptibility. The purpose of this study were to evaluate electromagnetic condition under usual clinical condition and to suggest a practical guideline in general hospital. Materials and Methods: The actual state of the electromagnetic interference in the medical field was studied under usual clinical conditions including operating rooms, intensive care units, magnetic resonance imaging unit, and hyperthermia unit. Results: There was considerable noise as a result of electromagnetic fields from medical equipments including electrosurgical units and hyperthermia unit, and cellular phones, which could induce serious functional derangements of functioning medical devices. Conclusion: It will be necessary to evaluate the individual electromagnetic situations under various medical conditions and to define a limited zone for cellular phone as well as reposition medical equipments to secure a safer medical practice and to minimize electromagnetic interference.

  • PDF