• Title/Summary/Keyword: Electromagnetic (EM)

Search Result 473, Processing Time 0.021 seconds

Development of Leakage Current Sensing Controller in Consideration of Industrial EMS (산업용 EMS를 고려한 누설전류 센싱 컨트롤러의 개발)

  • Park, Sung-Won;Roh, Inh-Bae;Kim, Sang-Dong;Park, Ji-Ho;Kim, Dong-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.70-71
    • /
    • 2009
  • In recent years, a importance of EMS(Electromagnetic Susceptibility) is increased with the spread of a communication device significantly. The compatibility of EMS is evaluated by conduction and radiation of EMI(Electromagnetic Interference). In this paper, a leakage current sensing controller which is considered of industrial EMS is developed. The developed system is consisted of power module, sensing module of leakage current, processer module, display module and communication module. The developed system is evaluated the compatibility of EMS by conduction and radiation of EMI. In evaluation results, the developed system is compatible to the standard of industrial EMS.

  • PDF

Development of an Externally Amplitude-and-Delay Equalized Narrow-Bandpass Filter for the Engineering Model Level Ka-band Input Demultiplexer (Engineering Model 급 Ka 대역 입력 Demultiplexer 용의 진폭 및 군지연 등화된 협대역 여파기의 개발)

  • 강승택;엄만석;이주섭;염인복;이성팔
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.347-351
    • /
    • 2002
  • 본 논문에서는, 위성 중계기 Engineering Model(EM)급 Ka 대역 입력 Demultiplexer (IMUX)의 진폭 및 군지연 등화된 채널 협대역 여파기의 개발/결과가 제시된다. 여파기는 큰 선택성(selectivity)과 작은 대역내 손실로써 동작하기 위해, 8차의 타원적분형 응답특성의 이중모드 결합구조의 특성을 가진다. 그리고 여파기 출력이 가지는 급한 변화의 군지연과 대역내 진폭은 2극(Pole) 등화기에 의해 평탄하게 된다. 튜닝 및 측정 결과는 요구규격사항을 잘 만족함을 보여준다.

  • PDF

Compact Metamaterial-Based Tunable Zeroth-Order Resonant Antenna with Chip Variable Capacitor

  • Jung, Youn-Kwon;Lee, Bomson
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.3
    • /
    • pp.189-191
    • /
    • 2013
  • This letter presents a compact metamaterial-based tunable zeroth-order resonant antenna. It is based on the double-negative unit cell with a function of tunable inductance realized by a varactor and impedance convertor in the shunt branch. The resonant frequency of the designed antenna ranges from 2.31 to 3.08 GHz, depending on the capacitance of the used varactor. Its size is very compact ($0.05{\lambda}_0{\times}0.2{\lambda}_0$) with a relatively wide tunable range of 29.1%. The impedance bandwidth of the antenna is from 20 to 50 MHz for the resonant center frequency. The measured maximum total realized gain is from -0.68 dBi (2.43 GHz) to 1.69 dBi (2.97 GHz). The EM-simulated and measured results are in good agreement.

Design of Engineering Model Oscillator with Low Phase Noise for Ka-band Satellite Transponder (위상잡음을 개선한 Ka-band 위성 중계기용 Engineering Model 발진기의 설계)

  • 류근관;이문규;염인복;이성팔
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.209-212
    • /
    • 2001
  • 본 논문에서는 Ka-band 위성 중계기용 국부 발진기에 사용하게 될 전압제어 발진기의 EM (Engineering Model)을 비선형 방법으로 설계하였다. 전압제어 발진기의 위상잡음을 개선하기 위하여 공진기로 사용되는 유전체 공진기와 결합하는 마이크로스트립 라인을 high impedance inverter로 구현함으로써 공진회로의 quality factor를 우수하게 유지하여 능동소자에 전달되도록 하였다. 개발된 전압제어 발진기는 0~12V의 제어전압으로 9.7965~9.8032GHz의 발진범위를 갖으며 공급전력은 8V, 17mA을 필요로 한다. 제작된 전압제어 발진기의 위상잡음은 -96.51dB/Hz @10KHz와 -116.5dBc/Hz @100KHz의 특성을 나타내며 출력전력은 7.33dBm을 얻었다.

  • PDF

LTCC Stacked Patch Antenna for 19GHz Band WLAN (19GHz대역 무선랜용 LTCC 적층형 패치 안테나)

  • Yeom, Chan-Kyu;Lee, Yun-Bok;Kim, Young-Do;Lee, Hong-Min
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.423-427
    • /
    • 2003
  • In this paper, LTCC stacked patch antenna with a radial CPW fed slot and grounded-shorting vertical-via wall for 19GHz band wireless LAN is presented. Suggested antenna employed a patch and grounded-shorting vertical-via wall for radiation element, consist of feeding structure which a radial open feature at the end of the CPW feed line. The optimal design parameters of the antenna using by EM simulation program. We can see that enough to bandwidth 560MHz for 19GHz band WLAN antenna specification by the optimized antenna.

  • PDF

Design of LTCC(Low Temperature Co-fired Ceramic) Bandpass Filter to Improve Characteristic of Rejection Band (저지대역 특성을 개선한 LTCC 대역 통과 여파기 설계)

  • Kim, Young-Ju;Park, Jun-Seok;Lim, Jae-Bong;Cho, Hong-Goo
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.256-259
    • /
    • 2003
  • In this paper, a design of multi-layered BPF(bandpass filter) using LTCC(Low Temperature Co-fired Ceramic) process by a lumped-elements is proposed for SOP(system-on-a-chip) of wireless communication systems. The proposed BPF improved a characteristic of rejection band to build an attenuation pole caused by structurally adjacent co-inductance and coupling. The simulation data shows a bandwidth of 90MHz from a center frequency of 2.4GHz, a return loss of 27dB, an insertion loss of 3.2dB, and an attenuation of at least 20dBc at $f_0{\pm}250MHz$. Simulations have used serenade circuit simulation and HFSS EM simulation.

  • PDF

전파무향실을 위한 광대역 페라이트 전파흡수체

  • 김동일;손준영
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.1
    • /
    • pp.43-50
    • /
    • 2003
  • 전자산업과 전파통신기술이 고도로 발전함에 따른 전파 이용의 증대로 인해 전자파환경 EMI/EMS이 사회적 문제를 야기하고 있다. 이에 따라, CISPR(Comite Internationale Special des Perturbations Radioelectrique), FCC (Federal Communications Commissions) ANSI (American National Standards Institute)등의 기구는 EMI/EMC 대책을 위해 전파환경의 규정을 제정하고 있다. 또한 EMI/EMC 측정을 위한 전파무향실(anechoic chamber)용 전파흡수체는 20 dB 이상의 전파흡수능이 요구된다. 종래의 EMI 측정 주파수 범위는 30 MHz~l,000 MHz 이었으나 1998년 11월, CISPR11은 1 GHz~18 GHz를 추가하는 안을 받아들였다. 본고는 새로운 형태의 다층형 페라이트 전파흡수체를 제안하고 등가재료정수법을 사용하여 광대역 설계를 시도한 것이다.

IEC 61000-4 시리즈(EMS)의 문제점과 오동작간의 관계분석

  • 민경찬
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.4
    • /
    • pp.92-96
    • /
    • 2003
  • 불요전자파, EMI의 규제 목적은 공중통신에 할당된 주파수를 보호하고 저전압 고속으로 동작하는 자동화 기기 즉 프로세서 제어기기의 오동작을 방지하기 위해 실시된다. 이에 반해 전자파 내성시험, EMS는 전기전자 기기가 각종 전자기적인 환경에 대해 얼마만큼 견딜 수 있는냐 혹은 오동작을 방지하기 위해 평가하게 된다. EMI 관련규정의 경우 오래전부터 연구 개량되어 일부 계측기 제조업체에서 장비판매를 목적으로 불필요한 규정을 만드는 것을 제외하고 큰 문제가 없다. 전자파 내성시험의 경우 어떤 경우이든 현장에서 발생되는 각종 오동작을 방지할 수 있는 시험항목과 시험레벨이 적용되어 평가되어야 한다. 본 고에서는 현용 IEC 61000-4-시리즈 내성시험항목과 적용 시험레벨의 문제점과 자동화 설비의 오동작간 상관관계에 대해 분석하여 기술한다.

Design of Multipactor-free S-band Duplexer Using New Test Method for Space Applications

  • Choi, Seung-Woon;Kim, Day-Young;Kwon, Ki-Ho;Won, Young-Jin;Lee, Yun-Ki
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.4
    • /
    • pp.217-221
    • /
    • 2006
  • Multipactor-free S-band duplexer based on inter-digital cavity type filter is proposed and demonstrated by in-house mulitpactor test facility for satellite RF components. Multipactor sensitivity of designed duplexer is analyzed by checking it out the maximum field accumulated region inside duplexer and calculating the electric field intensities at each resonator using 3D EM simulation in order to restrict the minimum gap distance as 2.5 mm which handles 43.13 dBm RF input power. Multipactor threshold was finally detected at 44 dBm in experiment for pulse mode test. The developed multipactor test method is cost effective, simple structure and gives a good agreement compared with the previous high cost MP test methodologies.

Deep structure of Ulsan fault by electric and EM surveys in ipsil area, South of Kyeongju (전기, 전자탐사에 의한 경주남부 (입실지역)의 울산 단층 심부구조)

  • 손호응
    • Economic and Environmental Geology
    • /
    • v.32 no.2
    • /
    • pp.161-167
    • /
    • 1999
  • Electric and electromagnetic surveys were conducted to investigate the deep structure of the Ulsan fault in Ipsil area, south of Kyeongju. On this study, especially high-frequency magnetotelluric method of electromagnetic survey in the frequency range of 10~100,000 Hz was mainly employed to study the deep subsurface configuration. High-frequency MT survey was performed at 70 points of spacing 30~50 m, making 3.8 km survey line. As a survey result, a 2-km-depth 2-D cross-section was achieved. It shows vertical and horizontal subsurface variations of resistivity values. Near-surface layer having low resistivity value becomes thicker eastward up to 800m. There is a steep low resistivity zone in the west side of survey line, and there exists two low resistivity zones dipping west in the east side of survey line. Two low resistivity zones are interpreted to be related to major movement pattern of the Ulsan fault. This suggests that major fault lines are developed on both peripheral sides of the broad fault zone.

  • PDF