• Title/Summary/Keyword: Electromagnetic (EM)

Search Result 474, Processing Time 0.02 seconds

UHF Band Multi-layer VCO Design Using RF Simulator (RF 시뮬레이터를 이용한 UHF대역 다층구조 VCO 설계)

  • Rhie, Dong-Hee;Jung, Jin-Hwee
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.96-99
    • /
    • 2001
  • In this paper, we present the simulation results of the multi-layer VCO(Voltage Controlled Oscillator), which is composed of the resonator, the oscillator and the buffer circuit. using EM simulator and nonlinear RF circuit simulator. EM simulator is used for obtaining the EM(Electromagnetic) characteristics of the conductor pattern as well as designing the multi-layer VCO. Obtained EM characteristics were used as real components in nonlinear RF circuit simulation. Finally the overall VCO was simulated using the nonlinear RF circuit simulator. The material for the circuit pattern was Ag and the dielectric was DuPont 951AT, which will be applied for LTCC process. The structure is constructed with 4 conducting layer. Simulated results showed that the output level was about 4.5[dBm], the phase noise was -104[dBc/Hz] at 30[kHz] offset frequency, the harmonics -8dBc, and the control voltage sensitivity of 30[MHz/V] with a DC current consumption of 9.5[mA]. The size of VCO is $6{\times}9{\times}2mm$(0.11[cc]).

  • PDF

Investigation on the Electromagnetic Characteristics of CMOS Rectangular Spiral Inductors according to the Geometrical Change (CMOS 직사각형 나선 인덕터의 기하학적 변화에 따른 전자기적 특성에 관한 연구)

  • Jin Kyoung-Shin;Kim Young-Sik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.12
    • /
    • pp.125-130
    • /
    • 2004
  • The characteristics of on-chip spiral rectangular inductors in CMOS process are investigated through the simulation and experiment. The ADS-momentum is used for EM simulation, and the spiral inductors are fabricated with Hynix 0.35㎛ CMOS process. This research mainly concerned the effects of the geometric change in terms of the number of turns and the width of micro strip line. The measured and simulated results show that the Hynix 0.35㎛ process could support a top metal spiral inductor of 1nH to 6nH with Q-factor less than 5.

Reduction of Radiated Emission of an Infrared Camera Using a Spread Spectrum Clock Generator (확산 스펙트럼 생성기를 이용한 적외선 카메라의 방사노이즈 저감에 관한 연구)

  • Choi, Bongjun;Lee, Yongchun;Yoon, Juhyun;Kim, Eunjun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.12
    • /
    • pp.1097-1104
    • /
    • 2016
  • The infrared camera is difficult to satisfy the RE-102 specification of Mil-Std-461. Especially, in the case of UAV electronics, shielded cable is not used, so it is difficult to meet the electromagnetic compatibility standard. In the RE-102 test of the IR camera for UAV, radiated noise exceeding 30 dBuV/m was observed in the range of 50 MHz to 200 MHz. As a result of pcb em scan, peak noise which caused by the harmonic frequency of the digital control signal clock was observed. Radiated noise was reduced by up to 22.9 dBuV/m by applying the spread spectrum clock generator(SSCG) with 3 % down spreading method to the camera control clock.

Effect of Borehole Fluid and Casing on the Borehole Electromagnetic Responses (공내수 및 케이싱이 시추공 전자탐사 반응에 미치는 영향)

  • Cho Seong-Jun;Kim Jung-Ho;Yi Myeong-Jong;Chung Seung-Hwan;Song Yoonho
    • Geophysics and Geophysical Exploration
    • /
    • v.2 no.2
    • /
    • pp.104-111
    • /
    • 1999
  • As a practical developing step of electromagnetic (EM) tomography technique, we quantitatively analyzed the effects of borehole fluid and casing on the borehole EM responses. The EM response turns out to have nothing to do with the property of the borehole fluid except in the close vicinity of the transmitter, which shows the wide perspective of the application of borehole EM. Single-hole responses in the presence of the steel casing throughly reflect those of the casing itself since its extremely high induction number or shallow skin depth. EM responses through steel casing do show the information of the host medium. In the near field region which corresponds to low frequency or the vicinity of the borehole, however, we can not separate the signal containing the information of the host from that of casing. Otherwise, the severe attenuation of energy in the casing at high frequencies renders the signal undetectable. The optimum frequency is, therefore, to be chosen to extract the information of the host considering both the property of the casing and the skin depth of the medium and the practical technique to determine the casing property through single-hole measurements is required.

  • PDF

Primary Solution Evaluations for Interpreting Electromagnetic Data (전자탐사 자료 해석을 위한 1차장 계산)

  • Kim, Hee-Joon;Choi, Ji-Hyang;Han, Nu-Ree;Song, Yoon-Ho;Lee, Ki-Ha
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.4
    • /
    • pp.361-366
    • /
    • 2009
  • Layered-earth Green's functions in electormagnetic (EM) surveys play a key role in modeling the response of exploration targets. They are computed through the Hankel transforms of analytic kernels. Computational precision depends upon the choice of algebraically equivalent forms by which these kemels are expressed. Since three-dimensional (3D) modeling can require a huge number of Green's function evaluations, total computational time can be influenced by computational time for the Hankel transform evaluations. Linear digital filters have proven to be a fast and accurate method of computing these Hankel transforms. In EM modeling for 3D inversion, electric fields are generally evaluated by the secondary field formulation to avoid the singularity problem. In this study, three components of electric fields for five different sources on the surface of homogeneous half-space were derived as primary field solutions. Moreover, reflection coefficients in TE and TM modes were produced to calculate EM responses accurately for a two-layered model having a sea layer. Accurate primary fields should substantially improve accuracy and decrease computation times for Green's function-based problems like MT problems and marine EM surveys.

Joint Electromagnetic Inversion with Structure Constraints Using Full-waveform Inversion Result (완전파형역산결과를 구조적 제약 조건으로 이용한 고해상도 전자탐사 복합역산 알고리듬 개발)

  • Jeong, Soocheol;Seol, Soon Jee;Byun, Joongmoo
    • Geophysics and Geophysical Exploration
    • /
    • v.17 no.4
    • /
    • pp.187-201
    • /
    • 2014
  • Compared with the separated inversion of electromagnetic (EM) and seismic data, a joint inversion using both EM and seismic data reduces the uncertainty and gives the opportunity to use the advantage of each data. Seismic fullwaveform inversion allows velocity information with high resolution in complicated subsurface. However, it is an indirect survey which finds the structure containing oil and gas. On the other hand, marine controlled-source EM (mCSEM) inversion can directly indicate the oil and gas using different EM properties of hydrocarbon with marine sediments and cap rocks whereas it has poor resolution than seismic method. In this paper, we have developed a joint EM inversion algorithm using a cross-gradient technique. P-wave velocity structure obtained by full-waveform inversion using plane wave encoding is used as structure constraints to calculate the cross-gradient term in the joint inversion. When the jointinversion algorithm is applied to the synthetic data which are simulated for subsea reservoir exploration, images have been significantly improved over those obtained from separate EM inversion. The results indicate that the developed joint inversion scheme can be applied for detecting reservoir and calculating the accurate oil and gas reserves.

A Study on Electromagnetic Properties in OPC Mortar with Different Chloride Content (염화물을 혼입한 OPC 모르타르의 전자기 특성에 대한 연구)

  • Kwon, Seung-Jun;Na, Ung-Jin;Feng, M.Q.
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.565-571
    • /
    • 2008
  • Recently, the evaluation technique using NDT (Nondestructive Technique : NDT) is widely utilized because it makes little damage on RC (Reinforced Concrete : RC) structures. The techniques using electromagnetic properties (EM properties) are also attempted for the evaluation of the performance of concrete which is nonmetallic. For the economic manufacturing of concrete material, sea-sand is often used as aggregate, however, chloride ion in concrete has direct effects on steel corrosion and EM properties. In this study, OPC mortar specimens with 5 different chloride amount (0.0, 0.6, 1.2, 2.4, and $3.6kg/m^3$) and 3 different water-cement ratios (45%, 55%, and 65%) are prepared in order to investigate the EM properties corresponding to concrete properties. The EM properties of conductivity and dielectric constant are measured in the frequency range over 0.2~20 GHz. To facilitate the comparison of EM properties with chloride content, average values are taken respectively for the conductivity and dielectric constant measured over the 5~20 GHz frequency range. According to the results of this experiment, dielectric constant and conductivity are increased with lower W/C ratio and larger amount of chloride content.

An Experimental Study on Electromagnetic Properties in Early-Aged Cement Mortar under Different Curing Conditions (양생조건에 따른 초기재령 시멘트 모르타르의 전자기 특성에 대한 실험적 연구)

  • Kwon, Seung-Jun;Song, Ha-Won;Maria, Q. Feng
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.737-746
    • /
    • 2008
  • Recently, NDTs (Non-Destructive Techniques) using electromagnetic(EM) properties are applied to the performance evaluation for RC (Reinforced Concrete) structures. Since nonmetallic materials which are cement-based system have their unique dielectric constant and conductivity, they can be characterized and changed with different mixture conditions like W/C (water to cement) ratios and unit cement weight. In a room condition, cement mortar is generally dry so that porosity plays a major role in EM properties, which is determined at early-aged stage and also be affected by curing condition. In this paper, EM properties (dielectric constant and conductivity) in cement mortar specimens with 4 different W/C ratios are measured in the wide region of 0.2 GHz~20 GHz. Each specimen has different submerged curing period from 0 to 28 days and then EM measurement is performed after 4 weeks. Furthermore, porosity at the age of 28 days is measured through MIP (Mercury Intrusion Porosimeter) and saturation is also measured through amount of water loss in room condition. In order to evaluate the porosity from the initial curing stage, numerical analysis based on the modeling for the behavior in early-aged concrete is performed and the calculated results of porosity and measured EM properties are analyzed. For the convenient comparison with influencing parameters like W/C ratios and curing period, EM properties from 5 GHz to 15 GHz are averaged as one value. For 4 weeks, the averaged dielectric constant and conductivity in cement mortar are linearly decrease with higher W/C ratios and they increase in proportion to the square root of curing period regardless of W/C ratios.

An efficient 2.5D inversion of loop-loop electromagnetic data (루프-루프 전자탐사자료의 효과적인 2.5차원 역산)

  • Song, Yoon-Ho;Kim, Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.1
    • /
    • pp.68-77
    • /
    • 2008
  • We have developed an inversion algorithm for loop-loop electromagnetic (EM) data, based on the localised non-linear or extended Born approximation to the solution of the 2.5D integral equation describing an EM scattering problem. Source and receiver configuration may be horizontal co-planar (HCP) or vertical co-planar (VCP). Both multi-frequency and multi-separation data can be incorporated. Our inversion code runs on a PC platform without heavy computational load. For the sake of stable and high-resolution performance of the inversion, we implemented an algorithm determining an optimum spatially varying Lagrangian multiplier as a function of sensitivity distribution, through parameter resolution matrix and Backus-Gilbert spread function analysis. Considering that the different source-receiver orientation characteristics cause inconsistent sensitivities to the resistivity structure in simultaneous inversion of HCP and VCP data, which affects the stability and resolution of the inversion result, we adapted a weighting scheme based on the variances of misfits between the measured and calculated datasets. The accuracy of the modelling code that we have developed has been proven over the frequency, conductivity, and geometric ranges typically used in a loop-loop EM system through comparison with 2.5D finite-element modelling results. We first applied the inversion to synthetic data, from a model with resistive as well as conductive inhomogeneities embedded in a homogeneous half-space, to validate its performance. Applying the inversion to field data and comparing the result with that of dc resistivity data, we conclude that the newly developed algorithm provides a reasonable image of the subsurface.

Applicability of the Small-Loop EM Method in the Sallow Marine Environment (천해 환경에서 소형루프 전자탐사의 적용성)

  • Song, Sung-Ho;Kim, Rae-Young;Kang, Hye-Jin;Cho, In-Ky
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.2
    • /
    • pp.152-157
    • /
    • 2011
  • The small-loop electromagnetic (EM) method is one of the rapid and non-destructive geophysical methods and has been used widely for many geophysical investigations, particularly for shallow engineering and environmental surveys. Especially in the shallow marine environment, the small-loop EM technique is very effective because of rapid and convenient data acquisition, large signal and low noise level. However, the method has been rarely applied in the very conductive marine environment since it's penetration or investigation depth might be considered too low. In this study, we demonstrated that the small-loop EM method can be effectively applied in the extremely conductive marine environment through the analysis of 1D small-loop EM data. Furthermore, we confirmed that the resistivity distribution under the sea bottom can be quantitatively predicted from the 1D inversion results of synthetic and field data.