• 제목/요약/키워드: Electrolyte filtration

검색결과 23건 처리시간 0.026초

Surface Chemical Aspects of Coagulation, Deposition, and Filtration Processes: Variation of Electrokinetic Potential at Metal Oxide-Water and Organic-Water Interfaces in the $Na^+$ and $Ca^{2+}$ Ion Solutions

  • Kim, Sung-Jae
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제4권3호
    • /
    • pp.173-183
    • /
    • 2000
  • This study measured the zeta potential of both latex colloidal particles with carboxylate surface groups and glass beads (collectors) with silanol surface group employing various solution with different chemical characteristics. The results have been compared with the surface chemistry theory. The zeta potential of the particle and collector increased with increasing pH up to 5.0 regardless of the solution chemistry. For a monovalent electrolyte solution(sodium chloride solution) the zeta potential steadily increased until the pH reached 9.5. In contrast, little change in zeta potential was made between 5.0 and 9.5 for a divalent electrolyte solution (sodium chloride solution) the zeta potential steadily increased until the pH reached 9.5. In contrast, little change in zeta potential was made between 5.0 and 9.5 for a divalent electrolyte solution (calcium chloride solution). In other words, the more the pH decreases, the larger the effect of neutral salts, such as NaCl and CaCl$_2$, have on the ζ-potential values. In this study, the PZPC(point of zero proton condition) of the particle and collector occurred below a pH of 3.1, H(sup)+ and OH(sup)- acted as a PDI (potential determining ion), and Na(sup)+ acted as an IDI(indifferent ion). The magnitude of the negative ζ-potential values of the particle and collector monotonically increased as the concentrations of Na(sup)+ or Ca(sup)2+([Na(sup)+] or [Ca(sup)2+]) decreased (the values of pNa or pCa increased). In the case of latex particles, the ζ-potential should aproach zero (isoelectric point; IEP) asymptotically as the pNa approaches zero, while in the case of calcium chloride electrolyte, ζ-potential reversal may be expected to occur around 3.16$\times$10(sup)-2MCaCl$_2$(pCa=1.5). pH, valance and ionic strength can be used in various ways to improve the water treatment efficiency by modifying the charge characteristics of the particle and collector. Predictive capability is far less certain when EDL(electrical double layer) repulsive forces exist between the particle and collector.

  • PDF

가토의 신장기능과 Renin분비에 미치는 Adenosine Analogues의 영향 (Effect of Adenosine Analogues on the Renal Function and Renin Release)

  • 송윤식;최병수;김선희;조경우
    • The Korean Journal of Physiology
    • /
    • 제22권2호
    • /
    • pp.319-332
    • /
    • 1988
  • The regulations of renal function and renin release are influenced by neural, humoral and physical factors. During the last decade, considerable progress has been made in the identification and characterization of these extrinsic renal control systems. Mechanisms intrinsic to the kidney are also important for renal function. These include the autoregulation of blood flow, and the local control of renin secretion. Fundamental questions regarding the mechanism of these intrinsic controls remain unanswered. Recently, endogenous renal adenosine has been claimed to influence the tubuloglomerular feedback control and renin release. Two subclasses of adenosine receptors $A_1{\;}and{\;}A_2$ have been described. The present experiment was carried out to evaluate the effects of $N_6-cyclohexyladenosine$ $(CHA,{\;}A_1{\;}selective)$ and 5'-N-ethylcarbox-amide adenosine $(NECA,{\;}A_2{\;}selective)$ on the renal function and renin release in the unanesthetized rabbit. Intra-renal arterial infusion of NECA $(0.3{\sim}10.0n{\;}mole/min/rabbit)$ or CHA $(0.03{\sim}10.0n{\;}mole/min/rabbit)$ caused a prompt and dose-dependent decrease in urine volume, glomerular filtration rate (GFR), renal plasma flow (RPF), filtration fraction (FF), electrolyte excretion and free water clearance $(CH_2O)$, the effect being much more profound with CHA than with NECA. The NECA infusion resulted in a profound decrease of systemic blood pressure, but the CHA infusion did not. Both NECA and GHA infusions caused a prompt and dose-dependent decrease in renin secretion rate, again the effect being greater with CHA than with NEGA. These results suggest that both $A_1{\;}and{\;}A_2$ adenosine receptors may be involved in the intrinsic control of renal function and renin release, and that the $A_1$ receptors plays a more important role than the $A_2$ receptor in the regulation of renal fnction.

  • PDF

소아의 만성신장질환의 치료 (Treatment of chronic kidney disease in children)

  • 이주훈
    • Clinical and Experimental Pediatrics
    • /
    • 제52권10호
    • /
    • pp.1061-1068
    • /
    • 2009
  • 만성 신질환 환아들의 치료는 신대체 요법과 더불어 적절한 식이 요법, 수분, 전해질 및 산-염기의 관리, 신장 골형성 장애의 예방 및 치료, 빈혈과 고혈압, 성장 지연의 치료 등으로 이루어진다. 식이 요법은 환아들의 성장이 충분히 이루어질 수 있도록 탄수화물, 지방, 단백질 및 열량의 공급이 적절하게 이루어져야 한다. 수분, 전해질 및 산-염기의 상태를 확인하고 적절하게 관리해야 한다. 혈청 칼슘, 인, 부갑상선 호르몬 농도가 사구체 여과율에 따른 적절한 목표치 안에서 유지될 수 있도록 인 결합 제제와 비타민 D 제제를 투여하여 신장 골형성 장애를 예방하여야 한다. 적혈구 생산 촉진제와 철분 제제를 투여하여 혈색소 값을 11-12 g/dl로 유지하여야 한다. 수분 및 염분의 균형과 적절한 항고혈압제의 투여로 고혈압을 조절해야 한다. 사람 재조합 성장 호르몬을 투여하여 최종 성인 키를 호전시키도록 한다.

Adult Idiopathic Renal Fanconi Syndrome: A Case Report

  • Park, Dae Jin;Jang, Ki-Seok;Kim, Gheun-Ho
    • 대한전해질대사연구회지
    • /
    • 제16권2호
    • /
    • pp.19-22
    • /
    • 2018
  • Renal Fanconi syndrome (RFS) is caused by generalized proximal tubular dysfunction and can be divided into hereditary and acquired form. Adult-onset RFS is usually associated with drug toxicity or systemic disorders, and modern molecular genetics may explain the etiology of previous idiopathic cases of RFS. Here, we report the case of a 52-year-old woman with RFS whose etiology could not be identified. She presented with features of phosphaturia, renal glucosuria, aminoaciduria, tubular proteinuria, and proximal renal tubular acidosis. Her family history was unremarkable, and previous medications were nonspecific. Her bone mineral density was compatible with osteoporosis, serum intact parathyroid hormone level was mildly elevated, and 25(OH) vitamin D level was insufficient. Her blood urea nitrogen and serum creatinine levels were 8.4 and 1.19 mg/dL, respectively (estimated glomerular filtration rate, $53mL/min/1.73m^2$). Percutaneous renal biopsy was performed but revealed no specific renal pathology, including mitochondrial morphology. No mutation was detected in EHHADH gene. We propose the possibility of involvement of other genes or molecules in this case of adult RFS.

리튬-황 전지용 프리스탠딩 플렉서블 S/CNT/NiO 전극의 제조 및 전기화학적 특성 (Preparation and Electrochemical Properties of Freestanding Flexible S/CNT/NiO Electrodes for Li-S Batteries)

  • 신윤정;이원열;김태윤;문승근;김은미;정상문
    • Korean Chemical Engineering Research
    • /
    • 제60권2호
    • /
    • pp.184-192
    • /
    • 2022
  • 수열합성을 통해 합성한 다공성 NiO는 리튬 폴리설파이드의 용출을 억제하기 위하여 리튬-황 전지의 전극에 사용되었다. 리튬-황 전지의 전극은 경제적이고 간단한 진공 여과 방법을 이용하여 집전체와 바인더가 없는 프리스탠딩 플렉서블 전극으로 제작되었다. 다공성 NiO를 첨가한 S/CNT/NiO 전극은 순수 S/CNT 전극에 비해 125 mA h g-1 증가한 877 mA h g-1 (0.2 C)의 초기 방전용량과 200 사이클 후 84% (S/CNT: 66%)의 우수한 용량 유지율을 나타내었다. 이는 방전 과정 중에서 NiO와 리튬 폴리설파이드의 강한 화학적 결합에 의하여 리튬 폴리설파이드의 전해질로 용출되는 것을 억제하여 나타난 결과이다. 또한 S/CNT/NiO 전극의 유연성 테스트를 위해 1.6 × 4 cm2의 파우치셀로 제작하여 폴딩한 상태와 하지 않은 상태에서 모두 620 mA h g-1의 안정적인 사이클 특성을 나타내었다.

전기화학적 방법을 이용한 Spent Granular Activated Carbon (GAC)의 재생 연구 (A Study of the Regeneration of Spent GAC using an Electrochemical Method)

  • 이상민;주수빈;조영수;오예지;김형준;심인태
    • 대한토목학회논문집
    • /
    • 제42권4호
    • /
    • pp.481-491
    • /
    • 2022
  • 본 연구는 CSOs의 고도처리를 목적으로 다단 횡류식 여과와 GAC 흡착조의 융합공정의 운영에서 GAC 흡착조의 유기물 처리 특성을 조사하고 설계 파과점에 도달한 GAC를 전기화학적 방법을 통한 재생효율을 평가하는 것이다. 여과공정은 부유물질은 용이하게 제거되지만 용존 유기물이 제거되지 않아 CSOs의 고도처리를 위해서는 용존유기물질의 제거능이 추가로 필요하다. 일반적으로 GAC 흡착은 정수처리 공정이나 하수의 3차 처리공정과 같은 저농도 유기물 조건에서 적용되어왔고 하수나 CSOs와 같이 유기물 농도가 높은 조건에서는 거의 적용이 되지 않았기에 본 연구에서 GAC를 이용한 CSOs 처리는 흥미로운 경험을 제공할 것이다. 본 연구는 유입 유기물 강도에 따른 GAC의 연속 운전 및 파과 특성을 조사하고 사용된 GAC를 전기화학적 재생을 적용하였으며, 이때 전압강도 및 전해액이 종류에 따른 흡착 유기물의 탈착 특성을 조사하였고 재생 후 GAC의 재흡착실험을 통해서 재생효율을 평가하였다. GAC 연속 운전결과 파과기간은 고농도 조건에서 21일, 중농도에서 28일 그리고 저농도에서 32일을 나타내었다. 전기분해를 통한 흡착 유기물의 탈착은 전기 분해 조건에 따라 188~609 mgCOD/L까지 발생하였고 전해액 종류의 영향은 NaOH가 H2O2보다 조금 우수한 탈착 특성을 나타냈다.

연령증가에 따른 Atrial Natriuretic Peptide의 신장과 호르몬 효과 (Effects of Atrial Natriuretic Peptide on Renal and Hormonal Balances in terms of Aging in Rabbits)

  • 김종덕;김선희;김정수;조경우
    • The Korean Journal of Physiology
    • /
    • 제23권1호
    • /
    • pp.51-66
    • /
    • 1989
  • Mammalian cardiocytes secrete atrial natriuretic peptides (ANPs) into plasma, which cause marked natriuresis, diuresis, vasorelaxation and inhibition of hormone secretions. Aging influences the ability of the kidney both to conserve and to excrete sodium; i.e., in old animals, the excretory capacity of sodium is reduced and the time required to excrete sodium load is prolonged. Therefore, it is possible that animals differing in ages may respond differently to ANP. In the present study, we determined whether the renal, hormonal and vascular effects of ANP may be influenced by aging in conscious rabbits. The plasma renin concentration decreased with aging but plasma ANP concentration was significantly lower only in 24-month-old rabbits. Plasma aldosterone concentration and atrial ANP content did not change by aging. In 1-month-old rabbits, ANP (atriopeptin III, 3 ug/kg) administered intravenously caused hypotension and decreased in plasma renin and aldosterone concentrations, but did not cause diuresis and natriuresis. In 2 to 5 month-old rabbits, ANP caused hypotension, decreases in Plasma renin and aldosterone concentrations and marked renal effects. However, in 24-month-old rabbits, all the above effects of ANP was blunted. With hydration of physiological saline at a rate of 15 ml/kg/h for 2hr, urine volume and glomerular filtration rate did not change but the electrolyte excretion as well as fractional excretion of sodium significantly increased. The plasma concentrations of active renin and aldosterone were decreased but plasma inactive renin and ANP concentrations were increased. The changes in renal function and plasma level of hormone showed no differences in different ages. These results suggest that the peripheral vascular receptors to ANP may develop earlier than those in the kidney, and the attenuated vascular and renal responses to ANP in the old age may be due to age-related modifications in renal function and blood vessel.

  • PDF

개의 신장기능에 미치는 Guanabenz의 영향 (Effects of Guanabenz on Renal Function in Dog)

  • 이상현;고석태
    • 약학회지
    • /
    • 제32권4호
    • /
    • pp.258-273
    • /
    • 1988
  • In this study attempts were made to observe the effects of guanabenz on renal function in dog, which manifests the antihypertensive action by inhibition of sympathetic tone through stimulating the presynaptic adrenoceptor (${\alpha}_2-adrenoceptor$). Guanabenz, when injected at a dose of $30.0{\mu}g/kg$, or infused at a dose of $3.0{\mu}g/kg/min$ intravenously, produced diuretic action with increased amounts of $Na^+\;and\;K^+$ in urine, and with decreased reabsorption rates of $Na^+\;and\;K^+$ in renal tubules. It was also observed that the rates of osmolar and free water clearances were increased, but the glomerular filtration rate and renal plasma flow were not changed. Guanabenz injected at a dose of $3.0{\mu}g/kg$ into a carotid artery or infused intravenously at a dose of $3.0{\mu}g/kg/min$ in a state of water diuresis elicited the diuretic action of the similar aspect as a case of guanabenz given intravenously. The diuretic action produced by guanabenz was completly blocked by pretreatment of i.v. prazosin, ${\alpha}_1-adrenoblocking$ agent, or of i.v. yohimbine, ${\alpha}_2-adrenergic$ blocking agent. Prazosin, when given into a renal artery, inhibited the diuretic action by i.v. guanabenz in only injected kidney, whereas in case of yohimbine the action was inhibited in both kidney. Guanabenz infused at a dose of $1.0{\mu}g/kg/min$ into a renal artery exhibited no significant changes of renal function in both kidney. In denervation experiments, guanabenz given intravenously produced typical diuretic action in innervated kidney, whereas in denervated kidney, it did not affect the action at initial period but exhibited the action with increase of only free water clearance at later period. These results suggest that guanabenz produced diuretic action in dog by inhibition of electrolyte reabsorption rates in renal tabules, mainly proximal tubule and of ADH release, which is mediated by stimulating of central sympathetic ${\alpha}_2-receptor$.

  • PDF

3D 프린팅을 이용한 Pt/Carbon Nanotube composite 기반 전기화학식 황화수소 가스 센서 제작 (Fabrication of Pt/Carbon Nanotube Composite Based Electrochemical Hydrogen Sulfide Gas Sensor using 3D Printing)

  • 하윤태;권진범;최수지;정대웅
    • 센서학회지
    • /
    • 제32권5호
    • /
    • pp.290-294
    • /
    • 2023
  • Among various types of harmful gases, hydrogen sulfide is a strong toxic gas that is mainly generated during spillage and wastewater treatment at industrial sites. Hydrogen sulfide can irritate the conjunctiva even at low concentrations of less than 10 ppm, cause coughing, paralysis of smell and respiratory failure at a concentration of 100 ppm, and coma and permanent brain loss at concentrations above 1000 ppm. Therefore, rapid detection of hydrogen sulfide among harmful gases is extremely important for our safety, health, and comfortable living environment. Most hydrogen sulfide gas sensors that have been reported are electrical resistive metal oxide-based semiconductor gas sensors that are easy to manufacture and mass-produce and have the advantage of high sensitivity; however, they have low gas selectivity. In contrast, the electrochemical sensor measures the concentration of hydrogen sulfide using an electrochemical reaction between hydrogen sulfide, an electrode, and an electrolyte. Electrochemical sensors have various advantages, including sensitivity, selectivity, fast response time, and the ability to measure room temperature. However, most electrochemical hydrogen sulfide gas sensors depend on imports. Although domestic technologies and products exist, more research is required on their long-term stability and reliability. Therefore, this study includes the processes from electrode material synthesis to sensor fabrication and characteristic evaluation, and introduces the sensor structure design and material selection to improve the sensitivity and selectivity of the sensor. A sensor case was fabricated using a 3D printer, and an Ag reference electrode, and a Pt counter electrode were deposited and applied to a Polytetrafluoroethylene (PTFE) filter using PVD. The working electrode was also deposited on a PTFE filter using vacuum filtration, and an electrochemical hydrogen sulfide gas sensor capable of measuring concentrations as low as 0.6 ppm was developed.

Effect of Changing Amniotic Fluid Osmolarity on the $Li^+$ Transport Through the Membrane Surrounding Amniotic Fluid in the Rabbit

  • Chang, Jin-Keun;Lee, Sang-Jin;Sung, Ho-Kyung
    • The Korean Journal of Physiology
    • /
    • 제27권1호
    • /
    • pp.13-25
    • /
    • 1993
  • To study the regulation of amniotic fluid volume and electrolyte concentration by the Membranes surrounding the amniotic fluid, the rate of $Li^+$ disappearance from amniotic sac of expired fetuses were examined while increasing the amniotic volume and osmolarity in rabbits. After intraamniotic injection of 1 ml isosmotic saline (about 20% of the amniotic fluid volume) containing 15 mM LiCl and 0.5 g/L Censored, the time courses of $Li^+$ and Censored disappearance were determined. From there the $Li^+$ clearance through the extrafetal routes was estimated and compared with that obtained from living fetuses. The volume, $Na^+$ concentration and osmolarity of amniotic fluid were measured and their relationships with $Li^+$ disappearance were evaluated. The fellowing results were obtained: 1. The rate of disappearance from amniotic fluid of living fetuses during the first 30 minutes was strikingly higher for $Li^+$ than for Censored, suggesting that extrafetal routes exist. At 60 and 90 minutes, however, the disappearance rate of $Li^+$ was less than that of Censored, suggesting the possibility of $Li^+$ reentry through fetal urination. 2. The disappearance of $Li^+$ from the amniotic fluid of the expired fetus was substantial, although lower than that of living fetuses, throughout the experimental period. 3. The $Na^+$ concentration and the osmolarity of the amniotic fluid of expired fetus measured 30 minutes after an intraamniotic injection of isoosmotic saline showed wide variation, but thereafter they changed gradually towards the normal extracellular fluid level. 4. When the amniotic fluid was iso- or hyposmolar, the rate of $Li^+$ disappearance from the amniotic fluid of the expired fetuses showed little variation. However, when the amniotic fluid was hyperosmolar, the rate at 30 minutes was markedly lower than those of isosmotic or hyposmotic amniotic fluid. At 90 minutes, the rate of $Li^+$ disappearance in hyperosmolar fluid reached a similar level to the rate in isosmolar fluid. 5. The intraamniotic injection of 400 mOsm/L saline solution decreased the disappearance rate of $Li^+$ from expired fetuses, while the injection of mannitol into the maternal vein induced no significant change. From these results it is concluded that: 1) a significant amount of $Li^+$ may leave the amniotic fluid via filtration through the membranes surrounding the amniotic fluid, 2) during hyperosmolar challenge to amniotic fluid, osmotic bulk flow might counteract the filterable loss, and 3) $Li^+$ disappearance might continue even after the volume and osmolarity of the amniotic fluid have recovered to control values.

  • PDF