• Title/Summary/Keyword: Electrolyte Amount

Search Result 278, Processing Time 0.022 seconds

A Study on Fluid Intake and Output Measurements (수분 섭취 및 배설량의 측정방법에 관한 연구)

  • Choi, Smi;Yang, Young-Hee;Jung, Yun
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.1
    • /
    • pp.88-98
    • /
    • 1995
  • The Fluid and electrolytes balance in the body is of critical importance in maintaining good health. When the fluid and electrolyte imbalance is present, patients are in great danger. They must be assessed immediately by a nurse so that appropriate treatment can be started as soon as possible. Patients' fluid intake and output records contain highly important information for the diagnosis and treatment of fluid imbalance, but, these records are often inaccurate and the method of recording the fluid intake is not universal for every hospital. Be-cause they are few quantitative measurements of a patient's hydration, the need to improve the accuracy of fluid intake records is very important. However, very few studies have been done to investigate the accuracy of measurements of patients' fluid intake and output. The purpose of this study was to investigate the methods used for calculation of fluid intake which is most similar to fluid output in normal adults and hospitalized patients. This study focused on three different calculation methods for fluid intake and compared these to fluid output and developed suggestions as to the ideal way to record fluid in-take. Data for 43 hospitalized patients and 37 normal adults were analyzed. The findings of this study are as follows ; 1) In normal adults, the daily intake of water which enteres by the oral route was 2415m1 (the first method of calculation). The daily intake of water in the form of pure water or some other beverage was 1365m1 (the third method of calculation) The daily intake of water including fresh fruits and vegetables, rice, porridges, and Me m which have water content more than 80% were 2186m1 (the second method of calculation). 2) The urine output of the normal adults was 1350m1. This apprroximates the amount of fluid an adult takes in the form of pure water. 3) In patient group, the total intake of water was 2550m1 (the first method of calculation). The in-take of water in the form of pure water or as some other beverage and IV fluid was 1661m1 (the third method of calculation). The daily in-take of water including foods which have high water content was 2356m1 (the second method of calculation). 4) The urine output of the patient's group was 1728m1. This approximates the amount of fluid an adult takes in the form of pure water. 5) Investigation of the method of calculation of the patient fluid intake showed that among the 31 hospitals studied, only eight use the third method of calculation which reflects the most close value to urine output. From the results obtained in this study, it was indicated that the amount of fluid taken in the form of pure water reflects the most close value to urine output. Therefore, it can be suggested that the third method of calculation which includes water in-take only in the form of pure water or beverage should be used as patients' fluid intake record.

  • PDF

MEMS-based Direct Methanol Fuel Cells and Their Stacks for the Reduction of Cell-to-Cell Deviation and Interconnection Voltage Drop (단위 셀간 성능편차 및 접속접안 강하 초소화를 위한 극소형 직접메탄올 연료전지 스택의 설계 및 제작)

  • Seo, Young-Ho;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.10
    • /
    • pp.981-985
    • /
    • 2007
  • We present a MEMS-based portable Direct Methanol Fuel Cell (micro-DFMC), featured by a platinum sputtered microcolumn electrode and a built-in fuel chamber containing a limited amount of methanol fuel. Also presented is a micro-DMFC stack structure having a common electrolyte sandwiched by the microcolumn electrodes. The single cells with ME16 and PE16 electrodes show the maximum power densities of $31.04{\pm}0.29{\mu}W/cm^2$ and $9.75{\pm}0.29{\mu}W/cm^2$, respectively; thus indicating the microcolumn electrode (ME16) generates the power density (3.2 times) higher than the planar electrode (PE16). The single cell tests of ME16 and ME4 electrodes (Fig.8) show the maximum power of $31.04{\pm}0.29{\mu}W/cm^2$, and $25.23{\pm}2.7{\mu}W/cm^2$, respectively; thus demonstrating the increased window frame reduces the normalized standard power deviation (standard deviation over the average power). The normalized deviation of 0.11 in ME4 cell has been reduced to 0.01 in ME16 cell due to the increased window frames. The maximum power density of 4-cell stack is 15.7 times higher than that of the single cell. 4-cell stack produces the power capacity of 20.3mWh/g during 980min operation at the voltage of 450mV with the load resistance of $800{\Omega}$.

THE RELATIONSHIP BETWEEN INTRAOPERATIVE FLUID MANAGEMENT AND POSTOPERATIVE ADVERSE OUTCOME IN A ORTHOGNATHIC SURGERY (악교정 수술중 수액요법과 술후 합병증의 연관성)

  • Lyoo, Jung-Ho;Kim, Dai-Yun;Bae, Jun-Su;Yang, Byung-Eun;You, Jun-Yong;Kim, Yong-Gwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.5
    • /
    • pp.428-434
    • /
    • 2001
  • Few topics in operative and perioperative patient management generate more controversy than that of appropriate fluid and electrolyte therapy. especially, controversy has swirled around colloid vs crystalloid therapy and the composition of administered fluids, agreement among clinicians as to what fluid therapy is appropriate, and in what amount, is rare. This controversy likely will be enhanced by Arieff' s provocative article. He described 11 adults and 2 pediatric patients. All developed fatal postoperative pulmonary edema, seemingly caused solely by excessive postoperative fluid administration. From January 1999 to December 1999, we investigated 24 patients, which were operated by orthognathic surgery, about the intraoperative fluid therapy and the associated effect in orthognathic surgery, which is regarded as one of the major surgery of oral and maxillofacial surgery. First, They were devided into two groups, that is one-jaw surgery and two-jaw surgery, and each groups were devided by intraoperative fluid volume of 8ml/kg/hr. Subjective assesment was collected through use of a series of 3 questionnaries. In each questionnaire, a 5-point Liekert scale was used far assessment of following parameters of recovery from anesthesia: headache, dizziness, drowsiness, nausea/vomiting, thirst. The patient completed questionnaire 1 at 4 hour after surgery, questionnaire 2 was completed at 24 hours after surgery, and questionnaire 3 was completed at 48 hours after surgery. This study demonstrated that appropriated perioperative rehydration decreases postoperative adverse outcomes and improved the patient's perception of the postoperative period.

  • PDF

Effect of Manganese Vanadate Formed on the Surface of Spinel Lithium Manganese Oxide Cathode on High Temperature Cycle Life Performance

  • Kim, Jun-Il;Park, Sun-Min;Roh, Kwang Chul;Lee, Jae-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.9
    • /
    • pp.2573-2576
    • /
    • 2013
  • Rate capability and cyclability of $LiMn_2O_4$ should be improved in order to use it as a cathode material of lithium-ion batteries for hybrid-electric-vehicles (HEV). To enhance the rate capability and cyclability of $LiMn_2O_4$, it was coated with $MnV_2O_6$ by a sol-gel method. A $V_2O_5$ sol was prepared by a melt-quenching method and the $LiMn_2O_4$ coated with the sol was heat-treated to obtain the $MnV_2O_6$ coating layer. Crystal structure and morphology of the samples were examined by X-ray diffraction, SEM and TEM. The electrochemical performances, including cyclability at $60^{\circ}C$, and rate capability of the bare and the coated $LiMn_2O_4$ were measured and compared. Overall, $MnV_2O_6$ coating on $LiMn_2O_4$ improves the cyclability at high temperature and rate capability at room temperature at the cost of discharge capacity. The improvement in cyclability at high temperature and the enhanced rate capability is believed to come from the reduced contact between the electrode, and electrolyte and higher electric conductivity of the coating layer. However, a dramatic decrease in discharge capacity would make it impractical to increase the coating amount above 3 wt %.

Performance Comparison Between Stationary PEMFC MEA and Automobile MEA under Pure Hydrogen Supply Condition (순수 수소 공급조건에서 정치용 PEMFC MEA와 차량용 MEA 성능비교)

  • Oh, Sohyeong;Lee, Mihwa;Lee, Hakju;Kim, Wookwon;Park, Jeong-Woo;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.56 no.4
    • /
    • pp.469-473
    • /
    • 2018
  • When pure hydrogen was supplied to the stationary PEMFC generally using the reforming gas, its characteristics were compared with the vehicle PEMFC. The effect of varying the amount of hydrogen supply to the anode on the overall performance was compared. The variation of hydrogen supply in the range of 1.0~1.7 excess (stoi.) had little effect on the OCV of stationary and vehicle MEA (Membrane and Electrode Assembly). At 0.7 V, the current density of the stationary MEA was about 16% higher than that of the vehicle MEA. I-V performance, impedance, and LSV were measured with varying relative humidity. Both OCV and electrolyte membrane resistances decreased with increasing relative humidity. The hydrogen permeability of the stationary MEA was lower than that of the vehicle MEA, showing that the durability of the stationary membrane could be higher than that of the vehicle membrane.

A Case of Activated Charcoal Aspiration Treated by Early and Repeated Bronchoalveolar Lavage (기관지내시경을 통해 치료한 활성탄 흡인 1예)

  • Lee, Han-Min;Park, Jae-Seok;Kim, Jae-Yun;Lee, Ji-Yeon;Ahn, Byung-Kyu;Gil, Hyo-Wook;Choi, Jae-Sung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.2
    • /
    • pp.177-181
    • /
    • 2012
  • Activated charcoal is an inert substance and it is used in standard therapy in patients with acute intoxication. Charcoal has some side effects such as pulmonary aspiration, gastrointestinal complications, and electrolyte abnormalities. Although aspiration of charcoal is a rare complication, it can cause fatal sequelae. We report a 69-year old man who developed acute respiratory failure associated with charcoal aspiration after management of glyphosate poisoning. The patient was drowsy and suffered severe vomiting during transport to our hospital. On arrival, acute respiratory failure was observed due to charcoal aspiration, but the clinical state was improved with repeated bronchoscopy with a bronchoalveolar lavage (BAL). We presumed that the aspirated charcoal was an important factor in evoking a lung injury. Early bronchoscopy with a BAL might be an effective method for eliminating charcoal from the lung, especially in the case of a large amount of aspiration, and be helpful in decreasing respiratory failure due to charcoal aspiration.

Nano Ceramic Coating on Polypropylene Separator for Safety-Enhanced Lithium Secondary Battery (고안전성 리튬이차전지 구현을 위한 나노 세라믹 코팅 분리막 제조 및 전기화학특성 분석)

  • Lee, Jungmo;Jeon, Hyunkyu;Han, Taeyeong;Ryou, Myung-Hyun;Lee, Yong Min
    • Journal of the Korean Electrochemical Society
    • /
    • v.20 no.2
    • /
    • pp.41-48
    • /
    • 2017
  • Herein, we have fabricated an ultrathin aluminum oxide ($Al_2O_3$) coated PP separator by using a RF sputter deposition process. Approximately 20 nm thickness coating layer on the bare PP separator was formed at the power of 55 W for 2 minutes without thermal damage. Whereas only permeability of the coated separator was degraded slightly, other properties such as thermal stability, uptake amount of liquid electrolyte, and ionic conductivity were improved comparing to the bare PP separator. As a result, an only 20-nm-thick $Al_2O_3$ coating layer could improve the rate capability compared with a bare PP separator under a high current density.

A study on the removal of As, Sb, Bi from the copper sulfate solutions by Ion exchange resin containing Aminophosphosphonic acid as a functional group (황산동용액(黃酸銅溶液)에서 Aminophosphosphonic acid 관능기를 가진 이온교환수지에 의한 As, Sb, Bi 제거(除去)에 관한 연구(硏究))

  • Ahn, Jae-Woo;Seo, Jae-Seong
    • Resources Recycling
    • /
    • v.21 no.5
    • /
    • pp.50-57
    • /
    • 2012
  • A comparative study has been carried out on the removal of impurities such As, Sb, Bi from the copper sulfate solution by ion exchange resin containing aminophosphosphonic acid as functional group. The various parameters which affect the removal of impurities; such as the reaction temperature, the reaction time, the amount of ion-exchange resins, the concentration of sulfuric acid in electrolyte, were studied. The basic experimental results showed that about 88% of Sb & 94% of Bi can be adsorbed in these chelate resins and removed from the copper sulfate solutions but As was removed below 10% from the solutions. And the selective elution of Bi and Sb from the adsorbed ion exchange resin also can be achieved by $H_2SO_4$ or HCl solutions. The results also showed that 98.1% of Sb and 96.6% of Bi can be adsorbed from the copper sulfate solutions after 2 Bed-volume of continuous ion exchange column test.

Interfacial Features of Colloidal Particles in Aqueous Environment and Change in Its Stability According to Influential Conditions (수중 콜로이드성 고형물의 계면화학적 특성 및 영향 인자 조건에 따른 안정성의 변화)

  • Shin, Sung-Hye;Kim, Dong-Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2227-2238
    • /
    • 2000
  • The interfacial features of suspension system made of $CaCO_3$ particles have been investigated for the purpose of designing its effective treatment process. For the examination of variation of electrokinetic potential as a function of pH. the value of potential was observed to shift in the negative direction, which was thought to be due to the adsorption of hydroxide ion on the particle surface. Adsorption of surfactant on suspended particles resulted in the change of surface charge and shift in electrokinetic potential, which was dependent upon the sign of head charge and concentration of surfactant. Addition of inorganic salts affected stability of suspension greatly and sedimentation rate of suspension was influenced by the electric valence and amount of ions produced by dissolution of inorganic coagulants. DLVO theory made it possible to construct a energy profile diagram and a close correlation was found between experimental result and theoretically derived consequences. Non-specific adsorption of indifferent electrolyte resulted in the compression of electrical double layer and specific adsorption induced the shift of IEP and PZC in the opposite direction.

  • PDF

Fabrication of Crystalline $ZrO_2$ Nanotubes by ALD

  • Kim, Hyeon-Cheol;Panda, Sovan K.;Yu, Hyeon-Jun;Kim, Myeong-Jun;Yang, Yun-Jeong;Lee, Seon-Hui;Sin, Hyeon-Jeong
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.241.1-241.1
    • /
    • 2011
  • Numerous possible applications for $ZrO_2$ nanotubes exist such as for catalyst support structures, for sensing or for applications as a solid state electrolyte. Especially, because of a large specific surface area, high efficiency for solid oxide fuel cell (SOFC) application at low temperature can be expected for nanotublar structures in even small size. A zirconium precursor, Tetrakis (ethylmethylamino) zirconium, TEMAZr and $H_2O$ oxidant were used to deposit$ZrO_2$ thin films on an anodized aluminum oxide (AAO) templates having sub-100nm cylindrical pores by atomic layer deposition (ALD) in the temperature range of 150~250$^{\circ}C$. The crystalline structures of as-prepared and post-annealed $ZrO_2$ nanotubes were characterized by x-ray diffraction and high-resolution transmission electron microscopy. The as-prepared samples at $150^{\circ}C$ and $200^{\circ}C$ were showed amorphous, whereas a mixed phase of tetragonal, monoclinic and amorphous polymorph was observed at $250^{\circ}C$. In the bulk, zirconia remains monoclinic phase up to $1,175^{\circ}C$, however, $ZrO_2$ nanotubes were showed tetragonal phase upon post thermal treatments merely at $400^{\circ}C$. This trend may be indicative of high-curvature surfaces of nanotubes and thereby the presence of intrinsic compressive strain. The amount of amorphous structures in the mixed phase as well as as-grown $ZrO_2$ nanotubes were also gradually decreased by subsequent heat treatment.

  • PDF