• Title/Summary/Keyword: Electrokinetic technology

Search Result 85, Processing Time 0.234 seconds

Electrokinetic Remediation of Cobalt Contaminated Soil Using Ethanoic Buffer

  • Kim, Gye-Nam;Won, Hui-Jun;Oh, Won-Zin;Shim, Jun-Bo
    • Nuclear Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • After kaolin clay was artificially contaminated with Co$^{2+}$ ion, the remediation characteristics were analyzed by the electrokinetic method. Ethanoic buffer was injected in the soil column and $CH_3$COOH was continuously inputted to the cathode reservoir to restrain the pH increase. Since the pH of the cathode side of the soil column was 4.0 initially and increased to only 6.5 after remediation for 43.6 hours, precipitate, Co(OH)$_2$, was not formed in the column. The effluent rate increased with the passage of time and Co$^{2+}$ removal in the column at the initial time were mainly controlled by ion migration. 13.1% of the total amount of Co$^{2+}$ in the soil column was removed in 10 hours, 46.8% of the total Co$^{2+}$ in 20.8 hours, 71.7% of the total Co$^{2+}$ in 30.1 hours, and 94.6% of the total Co$^{2+}$ in 43.6 hours. Meanwhile, residual concentrations in the column calculated by the developed model were similar to those by experiment. experiment.

Bioremediation of Diesel-Contaminated Soil by Bacterial Cells Transported by Electrokinetics

  • LEE, HYO-SANG;KISAY LEE
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.6
    • /
    • pp.1038-1045
    • /
    • 2001
  • The electrokinetic technology was applied in bioremediation for the purpose of supplying a Pseudomonas strain capable of degrading diesel to contaminated soil bed, and their biodegradation of diesel was carried out after a desired cell distribution was obtained. Electrokinetic injection of the strain was made possible because the cells acted as negatively charged particles at neutral pH, and thus the cells were transported with a precise directionality through the soil mostly by the mechanism of electrophoresis and in part by electroosmosis. A severe pH change in the soil bed was formed due to the penetration of electrolysis products, which was harmful to the cell viability and cell transport. To achieve a desirable cell transport and distribution, the control of pH in soil bed by a recirculating buffer solution in electrode chambers was essential during the appliation of an electric field. The judicious selections of electrolyte concentration and conductivity were also important for achieving an efficient electrokinetic cell transport since a higher electrolyte concentration favored the maintenance of pH stability in soil bed, but lowered electrophoretic mobility on the other hand. With electrolyte solution of pH 7 phosphate buffer, a 0.05 M concentration showed a better cell transport buffer, a 0.05 M concentration showed a better cell transport than 0.02 M and 0.08 M. The cell under pH 8 were obtained, compared to the cells under pH 7 or pH 9 in a given time period Up to $60\%$ of diesel was degraded in 8 days by the Pseudomonas cell, which were distributed electrokinetically under the conditions of pH 8 ($1,800{\mu}S/cm$, a mixture of phosphate and ammonia buffers) and 40 mA in a soil bed of 15 cm length.

  • PDF

Electrokinetic Remediation of Soil Contaminated with Zn, Ni and F (동전기 정화기술을 이용한 Zn, Ni, F 복합오염 토양의 정화)

  • Cho, Jung-Min;Ryu, Byung-Gon;Park, Sung-Woo;Kim, Kyeong-Jo;Baek, Ki-Tae
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.1
    • /
    • pp.36-43
    • /
    • 2009
  • The feasibility of electrokinetic remediation was investigated in the laboratory to treat contaminated soil with Zn, Ni and F. Electro-migration and electro-osmosis are the major removal mechanisms because fluorines desorbed from soil exist as an anionic form in soil pores, and Zn and Ni exist as a cationic form. Desorption of fluorine was enhanced under the alkaline condition, but that of Zn and Ni increased under the acidic condition. Sequential pH control was effective to control the mixed wastes from contaminated soil. 2 V/cm was applied to reactor to evaluate the effect of constant voltage gradient, after two weeks, the removal efficiency of Zn, Ni and F was 20.5%, 2.5% and 57.4%, respectively. Even though the removal of Zn and Ni was very low, the pH control enhanced transport of Zn and Ni significantly. As a result, sequential pH control is a effective method to remediate mixed waste-contaminated soil.

Study of physical simulation of electrochemical modification of clayey rock

  • Chai, Zhaoyun;Zhang, Yatiao;Scheuermann, Alexander
    • Geomechanics and Engineering
    • /
    • v.11 no.2
    • /
    • pp.197-209
    • /
    • 2016
  • Clayey rock has large clay mineral content. When in contact with water, this expands considerably and may present a significant hazard to the stability of the rock in geotechnical engineering applications. This is particularly important in the present work, which focused on mitigating some unwelcomed properties of clayey rock. Changes in its physical properties were simulated by subjecting the rock to a low voltage direct current (DC) using copper, steel and aluminum electrodes. The modified mechanism of the coupled electrical and chemical fields acting on the clayey rock was analyzed. It was concluded that the essence of clayey rock electrochemical modification is the electrokinetic effect of the DC field, together with the coupled hydraulic and electrical potential gradients in fine-grained clayey rock, including ion migration, electrophoresis and electro-osmosis. The aluminum cathodes were corroded and generated gibbsite at the anode; the steel and copper cathodes showed no obvious change. The electrical resistivity and uniaxial compressive strength (UCS) of the modified specimens from the anode, intermediate and cathode zones tended to decrease. Samples taken from these zones showed a positive correlation between electric resistivity and UCS.

산업단지내 독성유기화합물 및 중금속으로 오염된 토양의 정화복원기술 상용화 연구

  • 김수곤;손규동;박지연;최희철;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.31-34
    • /
    • 2004
  • Feasibility of electrokinetic(EK)-Fenton process and Ozone chemical oxidation were investigated for tile removal of organic contaminants and heavy metals from the contaminated soil. In EK-Fenton process, accumulated electroosmotic flow(EOF) was 80 L for 26 days. Removal efficiency of TPH, As, and Ni were 61%, 36%, and 47%, respectively. The concentration of As was high near the anode due to the transport of anionic As toward the anode, while the concentration of Ni was high near the cathode by the movement of cationic Ni to the cathode. Field scale application of in-situ ozonation was carried out for removal of TPH in 3-D test cell (3 m$\times$2 m$\times$2 m). After 25 days of ozone injection, more than 80% of removal rate was observed through the test cell.

  • PDF

계면활성제와 동전기 기술을 이용한 오염토양정화에서 APG사용의 타당성에 관한 연구

  • 양지원;이유진;박지연;김상준
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.243-246
    • /
    • 2002
  • Surfactant-enhanced electrokinetic remediation is an emerging technology that can effectively remove hydrocarbons from low-permeability soils. In this study, the electrokinetic remediation using APG(alkyl polyglucoside) was conducted for the removal of phenanthrene from kaolinite. APG, which was an environmentally compatible and non-toxic surfactant, was used at concentrations of 5, 15, and 30g/1 to enhance the solubility of phenanthrene. Also an electrolyte solution was used for considering a relation between electrical potential gradient and removal efficiency of phenanthrene. When the electrolyte solution was used, it represented low electrical potential gradient, but the removal efficiency was lower than that of no electrolyte system. Removal efficiency of phenanthrene in EK process using surfactant solution depended on concentration of surfactant. Because surfactant increased the solubility and the mobility of phenanthrene, when surfactant concentration was high, high removal efficiency was observed.

  • PDF

Improved Treatment Technique for the Reuse of Waste Solution Generated from a Electrokinetic Decontamination System (동전기제염장치에서 발생한 폐액의 재사용을 위한 개선된 처리기술)

  • Kim, Wan-Suk;Kim, Seung-Soo;Kim, Gye-Nam;Park, Uk-Ryang;Moon, Jei-Kwon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • A large amount of acidic waste solution is generated from the practical electrokinetic decontamination equipments for the remediation of soil contaminated with uranium. After filtration of uranium hydroxides formed by adding CaO into the waste solution, the filtrate was recycled in order to reduce the volume of waste solution. However, when the filtrate was used in an electrokinetic equipment, the low permeability of the filtrate from anode cell to cathode cell due to a high concentration of calcium made several problems such as the weakening of a fabric tamis, the corrosion of electric wire and the adhension of metallic oxides to the surface of cathode electrode. To solve these problems, sulfuric acid was added into the filtrate and calcium in the solution was removed as $CaSO_4$ precipitate. A decontamination test using a small electrokinetic equipment for 20 days indicated that Ca-removed waste solution decreased uranium concentration of the waste soil to 0.35 Bq/g, which is a similar to a decontamination result obtained by distilled water.

Precipitation-Filtering Method for Reuse of Uranium Electrokinetic Leachate (우라늄 오염 동전기 침출액의 재이용을 위한 침전-여과 방법)

  • Kim, Gye-Nam;Shon, Dong-Bin;Park, Hye-Min;Kim, Ki-Hong;Lee, Ki-Won;Moon, Jeik-kwon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.2
    • /
    • pp.63-71
    • /
    • 2011
  • A large volume of uranium electrokinetic leachate has been generated during the electrokinetic decontamination to remove uranium from contaminated soil. The treatment technology for the reuse of the uranium leachate was developed. The concentration of uranium in the generated uranium leachate was 180 ppm and concentrations of Mg(II), K(I), Fe(II), and Al(III) ions ranged from 20 ppm to 1,210 ppm. The treatment process for uranium leachate consisted mainly of mixing and cohesion, precipitation, concentration, and filtration. In order to obtain the pH=11 of a precipitate solution, the calcium hydroxide needs to be 3.0g/100ml and the sodium hydroxide needed to be 2.7g/100ml. The results of several precipitation experiments showed that a mixture of NaOH+0.2g alum+0.15g magnetite was an optimal precipitant for filtration. The average particle size of precipitate with NaOH+alum+0.15g magnetite was $600\;{\mu}m$. Because the total value of metal concentrations in supernatant at pH=9 was the smallest, sodium hydroxide should be added with 0.2g alum and 0.15g magnetite for pH=9 of leachate.

Dewatering of Sewage Sludge by Electrokinetics (동전기를 이용한 슬러지 탈수에 관한 연구)

  • Kim, Ji Tae;Won, Se Yeon;Cho, Won Cheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6B
    • /
    • pp.661-667
    • /
    • 2006
  • In this study, an experiment of sewage sludge dewatering is carried by using electrokinetic method, and the electrokinetic dewatering efficiency of digested sludge is analyzed. Digested sludge without coagulants is selected and gravitational and pressing dewatering methods are applied in combination with electro-osmotic and electro-osmotic pulse technology. After the test of digested sludge, dewatering test of thickened sludge is carried to evaluate the electrokinetic dewatering feasibility of thickened sludge. Under the condition of constantly applied voltage, however, electrical resistance increases with decreasing of water content so that dewatering rate decreases with time. To reduce such a hindrance caused by constantly applied voltage, electro-osmotic pulse technology which is considered to reduce the difference of water content with height, is applied. For the application of electro-osmotic pulse, the dewatered flow rate and the dewatered volume became more increasing from the middle of the dewatering process than that of continuous voltage. Through the test of thickened sludge, electro-osmotic dewatering combined with gravitational and expression also showed high dewatering rate, which proved the possibility of using electrokinetic dewatering.

Microflow of dilute colloidal suspension in narrow channel of microfluidic-chip under Newtonian fluid slip condition

  • Chun Myung-Suk;Lee Tae Seok;Lee Kangtaek
    • Korea-Australia Rheology Journal
    • /
    • v.17 no.4
    • /
    • pp.207-215
    • /
    • 2005
  • We present a finite difference solution for electrokinetic flow in rectangular microchannels encompassing Navier's fluid slip phenomena. The externally applied body force originated from between the nonlinear Poisson-Boltzmann field around the channel wall and the flow-induced electric field is employed in the equation of motion. The basic principle of net current conservation is applied in the ion transport. The effects of the slip length and the long-range repulsion upon the velocity profile are examined in conjunction with the friction factor. It is evident that the fluid slip counteracts the effect by the electric double layer and induces a larger flow rate. Particle streak imaging by fluorescent microscope and the data processing method developed ourselves are applied to straight channel designed to allow for flow visualization of dilute latex colloids underlying the condition of simple fluid. The reliability of the velocity profile determined by the flow imaging is justified by comparing with the finite difference solution. We recognized the behavior of fluid slip in velocity profiles at the hydrophobic surface of polydimethylsiloxane wall, from which the slip length was evaluated for different conditions.