• Title/Summary/Keyword: Electrokinetic(EK) Remediation

Search Result 28, Processing Time 0.021 seconds

계면활성제와 동전기 기술을 이용한 오염토양정화에서 APG사용의 타당성에 관한 연구

  • 양지원;이유진;박지연;김상준
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.243-246
    • /
    • 2002
  • Surfactant-enhanced electrokinetic remediation is an emerging technology that can effectively remove hydrocarbons from low-permeability soils. In this study, the electrokinetic remediation using APG(alkyl polyglucoside) was conducted for the removal of phenanthrene from kaolinite. APG, which was an environmentally compatible and non-toxic surfactant, was used at concentrations of 5, 15, and 30g/1 to enhance the solubility of phenanthrene. Also an electrolyte solution was used for considering a relation between electrical potential gradient and removal efficiency of phenanthrene. When the electrolyte solution was used, it represented low electrical potential gradient, but the removal efficiency was lower than that of no electrolyte system. Removal efficiency of phenanthrene in EK process using surfactant solution depended on concentration of surfactant. Because surfactant increased the solubility and the mobility of phenanthrene, when surfactant concentration was high, high removal efficiency was observed.

  • PDF

화학적 특성이 다른 두 토양에서 EK-Fenton 공정 적용 시에 $H_2O_2$의 거동과 phenanthrene의 처리특성

  • 김정환;이군택;한상재;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.128-131
    • /
    • 2003
  • To clarify the effect of soil property on the EK-Fenton remediation of the soil contaminated with phenanthrene, this research had been conducted. In the experiments using EPK kaolinite, the $H_2O$$_2$ stability and effect of phenanthrene treatment improved more than that in the experiments using Hadong clayey soil. The results signify that Fe oxide content and acid buffer capacity significantly affected the fate of $H_2O$$_2$ and phenanthrene during the EK-Fenton process.

  • PDF

Effect of Electrolyte Concentration on Surfactant-Enhanced Electrokinetic Removal of Phenanthrene

  • 이유진;박지연;김상준;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.346-349
    • /
    • 2004
  • Surfactant-enhanced electrokinetic (EK) process was investigated to remove polycyclic aromatic hydrocarbons (PAHs) from low-permeable soils. Phenanthrene and kaolinite were selected as a representative PAH and a model soil, respectively. A nonionic surfactant Tergitol 15-S-12 was applied to improve the solubility of phenanthrene and sodium chloride was used as an electrolyte at the various concentrations from 0.001 to 0.1M. The addition of electrolyte affected both the removal efficiency and operation cost. When electrolyte was introduced, the electrical potential gradient became low and thus power consumption was reduced. However, as electrolyte concentration increased, the electroosmotic flow also decreased, so the removal efficiency of contaminant decreased. Therefore, the removal efficiency and power consumption should be considered simultaneously to determine the iptimum surfactant concentration, so a relatively lower concentration of electrolyte than certain value is desired.

  • PDF

Phenanthrene으로 오염된 Kaolinite에 Electrokinetic-Fenton 기법 적용시 묽은 산의 주입에 따른 효과

  • 김정환;김기년;한상재;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.318-321
    • /
    • 2003
  • This study explored the feasibility of applying Electrokinetic-Fenton process(EK-Fenton process) to remediation of contaminant sorbed on the soil possessed low-permeability. The addition of 0.01 N H$_2$SO$_4$ in the anode reservoir for the $H_2O$$_2$stabilization improved the stabilization of $H_2O$$_2$and the treatment effect of phenanthrene across the entire soil specimen. The use of $H_2O$$_2$and dilute acid as anode purging solution is a promising method treating of HOCs in low-permeability subsurface environments.

  • PDF

The Remediation Characteristic of Soil Contaminated with Heavy Metal and Total Petroleum Hydrocarbon (TPH) by Enhanced Electrokinetic with Fenton Oxidation and Soil Flushing Method (펜톤 산화와 토양 세정이 보강된 동전기에 의한 중금속 및 총 석유 탄화수소(TPH)로 오염된 토양의 정화 특성)

  • Seo, Seok-Ju;Na, So-Jeong;Kim, Jung-Hwan;Park, Joo-Yang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.885-893
    • /
    • 2014
  • This research reports the enhanced Electrokinetic (EK) with $H_2O_2$ and sodium dodecyl surfate (SDS), which are commonly used in Fenton oxidation and soil flushing method, in order to remediate soil contaminated with heavy metals and Total Petroleum Hydrocarbons (TPH) simultaneously. In addition, influences of property of soil and concentration of chemical solution were investigated through experiments of different types of soils and varying concentration of chemical reagents. The results indicated, in the experiments using artificially contaminated soil, the highest removal efficiency of heavy metals using 10% $H_2O_2$ and 20mM SDS as electrolytes. However, in the experiments using Yong-San soils (study area), remediation efficiency of heavy metals was decreased because high acid buffering capacity. Through experiment of 20% $H_2O_2$ and 40mM SDS, increased electric current influences the remediation of heavy metals due to decrease in the soil pH. In the experiments of Yong-San soils, the remediation efficiency of TPH was decreased compared with artificially spiked soils because high acid buffering capacity and organic carbon contents. Furthermore, the scavenger effect of SDS influenced TPH oxidation efficiency under the conditions of injected 40mM SDS in the soils. Therefore, the property of soil and concentration of chemical reagents cause the electroosmotic flow, soil pH, remediation efficiency of heavy metals and TPH.

A Field Study on Electrokinetic Removal of Salts from Greenhouse Soil (전기동력학 기술을 이용한 시설재배지 토양 염류제거 실증 연구)

  • Lee, You-Jin;Choi, Jeong-Hee;Sim, Seong-Ju;Ha, Tae-Hyun;Lee, Hyun-Goo
    • Korean Chemical Engineering Research
    • /
    • v.52 no.1
    • /
    • pp.126-132
    • /
    • 2014
  • A pilot-scale electrokinetic (EK) separation field test ($2{\times}3{\times}0.2m^3$, $W{\times}L{\times}D$) was performed in a greenhouse to remove salts from saline soil. Initially, the greenhouse soil had high electrical conductivity (EC), about 9 dS/m, and contained mainly $Ca^{2+}$, $Cl^-$ and $SO_4^{2-}$ ions. After 2 weeks of EK treatment, the soil EC was reduced to 52% compared with its initial value. The EC reduction was mostly achieved within the first week (47%) due to removal of $Na^+$ and $Cl^-$ ions, but ions with a high adsorption capacity such as $Ca^{2+}$ and $SO_4^{2-}$ ions were difficult to be removed. During the EK test, the soil temperature increased and it reached around $50^{\circ}C$ at some regions. For in situ application to soils in cultivation, the current should be controlled to limit increases in temperature, especially near the cathodes. In conclusion, the in situ EK technique is feasible for the restoration of saline greenhouse soils in or no cultivation and an appropriate strategy is necessary for more effective remediation.

Removal of Phenanthrene by Electrokinetic-Fenton Process in a 2-dimensional Soil System (동전기-펜턴 공정을 이용한 2차원 토양 정화장치에서의 phenanthrene 제거)

  • Park Ji-Yeon;Kim Sang-Joon;Lee You-Jin;Yang Ji-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.5
    • /
    • pp.11-17
    • /
    • 2005
  • Characteristics of phenanthrene removal in the Electrokinetic (EK)-Fenton process were investigated in a 2-dimensional test cell in a viewpoint of the effect of gravity and electrosmotic flow (EOF). When the constant voltage of 100 V was applied to this system, the current decreased from 1,000 to 290 mA after 28 days, because soil resistance increased due to the exhaustion of ions in soil by electroosmosis and electromigration. Accumulated EOF in two cathode reservoirs was 10.3 L and the EOF rate was kept constant for 28 days. At the end of operation, the concentration of phenanthrene was observed to be very low near the anode and increased in the cathode region because hydrogen peroxide was supplied from anode to cathode region following the direction of EOP. Additionally, the concentration of phenanthrene decreased at the bottom of the test cell because the electrolyte solution containing hydrogen peroxide was largely transported toward the bottom due to a low capillary action in the soil with high porosity. Average removal efficiency of phenanthrene by EK-Fenton process was 81.4% for 28 days. In-situ EK-Fenton process would overcome the limitations of conventional remediation technologies and effectively remediate the contaminated sites.

Remediation of Electroplating Contaminated Soil by a Field Scale Electrokinetic System with Stainless Steel Electrodes

  • Yuan, Ching;Tsai, Chia-Ren;Hung, Chung-Hsuang
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.5
    • /
    • pp.26-34
    • /
    • 2014
  • A $1.5m(L){\times}1.0m(W){\times}1.1m(H)$ polypropylene (PP) field scale electroniketic system coupled with stainless steel electrodes was designed to examined metal removal performance applied 0.2-0.35 V/cm potential gradient and 0.05-0.5M lactic acid for 20 day. Electroosmosis permeabilities of $2.2{\times}10^{-5}cm^2/V-s$ to $4.8{\times}10^{-5}cm^2/V-s$ were observed and it increased with the potential gradient increased. The reservoir pH controlled at $7.0{\pm}1.0$ has been effectively diminished the clogging of most metal oxides. The best removal efficiency of Zn, Pb, and Ni was 78.4%, 84.3%, and 40.1%, respectively, in the field scale EK system applied 0.35 V/cm and 0.05M lactic acid for 20 days. Increasing potential gradient would more effectively enhance metal removal than increasing concentration of processing fluid. The reservoir and soil temperatures were majorly related to potential gradient and power consumptio. A $4-16^{\circ}C$ above room temperature was observed in the investigated system. It was found that the temperature increase in soil transported the pore water and metals from bottom to the topsoil. This vertical transport phenomenon is critical for the electrokinetic process to remediate in-situ deep pollution.