• Title/Summary/Keyword: Electrodeless

Search Result 175, Processing Time 0.029 seconds

A Dimmable High Frequency Resonant Inverter for Electrodeless Lamps (조광제어형 무전극 램프용 고주파 공전형인버터)

  • Yeon, Jae-Eul;Cho, Kyu-Min;Oh, Won-Seok;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.487-489
    • /
    • 2004
  • As the electrodes are not needed, the electrodeless lamps using the induction discharge have a long lifetime and are robust against the variable output condition of a ballast. This paper proposed a dimmable resonant inverter for the electrodeless lamps. The proposed resonant inverter formed a half bridge inverter adopted FWM to control the average output power of the inverter and the illumination of a lamp. In this paper, the proposed dimming algorithm was described and the prototype experimental setup for 100W electrodeless lamps was carried out to verify the validity of the proposed dimming method.

  • PDF

Impedance and Q-factor of frequence dependance accoding to ferrites on electrodeless fluorescent lamp (무전극 형광램프의 페라이트 종류에 따른 임피던스 및 Q-Factor의 주파수 의존성)

  • Kim, Hoe-Geun;You, Dae-Won;Park, Sung-Mook;Pack, Gwang-Hyeon;Choi, Young-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.3-7
    • /
    • 2004
  • An electric power efficiency of electrodeless fluorescent lamp has big relativie property of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. We have examined resistance kind, impedance, Q-factor's frequency characteristic by ferrite. Impedance, resistance and capacitance did not show difference in start frequency 2.65 [MHz] but there was difference quantity. We could know Q-factor's difference according to material, and Q-factor's is important part of antenna design.

  • PDF

Electromagnetic Properties of Ring -Shaped Electrodeless Fluorescent Lamps for Ferrite Core (페라이트를 이용한 환형 무전극 램프의 전자계 특성)

  • Jo, Ju-Ung;Lee, Seong-Jin;Choi, Yong-Sung;Kim, Yong-Kab;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.249-251
    • /
    • 2003
  • The ring-shaped electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. Therefore, the line time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250[kHz] and some specific conditions.

  • PDF

Electromagnetic Radiation Properties of Electrodeless Fluorescent Lamps (무전극 형광램프의 전자계 방사 특성)

  • Lee, Jong-Chan;Park, Dae-Hee;Kim, Kwang-Soo;Ham, Hum;Park, Sung-Mok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.931-934
    • /
    • 2002
  • In recent year there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, the advantage of Electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. Therefore, the life of Electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 100,000 hours. In this paper, the Electromagnetic emitting properties were presented by simulation software operated at 2.65MHz and some specific conditions.

  • PDF

Emission characteristic along a magnetic flux density change of Antenna for Electrodeless Fluorescent Lamp (무전극 형광램프용 안테나의 자속밀도 변화에 따른 발광 특성)

  • Her, In-Sung;Kim, Nam-Gun;Choi, Yong-Sung;Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.644-647
    • /
    • 2004
  • Recently, the environmental problem has received considerable attention. so, many lamps have been developing for environmental requirement and energy efficiency, also, at glow discharge lamp researchers try to reduce energy spending that is power saving lamp. this kind requirement agree with strong points of electrodeless fluorescent lamp has received to now lighting sauce. In this paper, at the research and development of Electrodeless Fluorescent Lamp phase, according to ferrite C.F.D(Computational Fluid Dynamics) Simulation and lamp brightness character are measured to find optimization design requirements of RF antenna which is impotent for emission of lamp.

  • PDF

A Study of High Efficiency Electrodeless lamp Properties (고효율 신광원 시스템의 특성에 관한 연구)

  • Kim, H.S.;Lee, S.H.;Shin, S.W.;Lim, J.M.;Huh, S.K.;Hwang, M.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1717-1720
    • /
    • 2002
  • Electrodeless discharge lamps have been objects of interest and research for several decades, mainly because of their potential for extremely long life, high lamp efficacies and smaller than standard fluorescent lamps size. A series of measurements and observations concerning variables has yielded optical and electrical characteristics for electrodeless discharge lamp like incandescent lamp and circular lamp feature. Last experiment were carried out to determine the lamp temperature at several surface points during operation. Light output levels in excess over 60,000 cd/$m^2$ have been measured in electrodeless discharge lamp for a general of conditions. At lamp surface temperatures have been measured over $80^{\circ}C$, and starting current have been measured over ${\sim}A$.

  • PDF

Electromagnetic Field Analyses of Electrodeless Fluorescent Lamp (무전극 전구형 형광램프의 전자계 해석)

  • Kim, Kwang-Soo;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dea-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.67-70
    • /
    • 2002
  • The electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. but Increasing awareness of electromagnetic compatibility(EMC) issues in lighting application, the problems of interference generation by electrodeless fluorescent lighting system have been highlighted. In this paper, Maxwell 2D finite element analysis program(ansoft) is used to obtain electromagnetic properties associated with the coil and nearby structures. and also evaluated Flux, B, H, by changing the input current.

  • PDF

Analysis of Optical and Electromagnetic Distribution of Ring-shaped Electrodeless Fluorescent Lamps (환형 무전극 램프의 광학적, 전자계적 해석)

  • 조주웅;최용성;김용갑;박대희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.4
    • /
    • pp.460-464
    • /
    • 2004
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, the advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours and is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by D simulation software operated at 250KHz and some specific conditions. Photometric characteristic of the ring-shaped electrodeless fluorescent lamp were investigated using LS-100 lightmeter and TA-0510 thermometer respectively.

Brightness special Quality change of wireless electrodeless fluorescent lamp by ferrite change (페라이트 변화에 따른 무전극 형광램프의 휘도 특성 변화)

  • Pack, Gwang-Hyoen;Yang, Jong-Kyung;Lee, Jong-Chang;Choi, Yung-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.171-176
    • /
    • 2004
  • An electric power efficiency of electrodeless fluorescent lamp has big relative propertye of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. Coill turn was changed from 13th to 15th turn to recognize brightness change of lamp by winding number. Optical equipment that used in an experiment was used to measure brightness (LS-100). When an electrodeless fluorescent lamp was made using and T company's PE22, was it showed the highest brightness. As number of winding is increased the brightness increased, and starting characteristic became good.

  • PDF

Temperature Dependence of Round type electrodeless lamp (둥근형 무전극 램프의 온도 의존성)

  • Kim, Nam-Goon;Yang, Jong-Kyung;Lee, Joo-Ho;Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.246-247
    • /
    • 2007
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above ail, the advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours and is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. In this paper, when appling the electrodeless lamp in luminaire, We analyzed change of optical and electrical characteristics.

  • PDF