• 제목/요약/키워드: Electrodeless

검색결과 175건 처리시간 0.023초

13.56MHz ICP에서 단일 탐침법에 의한 Ne 가스의 발광특성 연구 (A Study on Emission Characteristics of Ne Gas Using a Single Langmuir Probe Method in Radio-Frequency Inductively Coupled Plasma)

  • 조주웅;최용성;김용갑;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.150-152
    • /
    • 2004
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. The electrodeless fluorescent lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. In this paper, electron temperature and electron density were measured in a radio-frequency inductively coupled plasma using a Langmuir probe method for emission characteristics. Measurement was conducted in an Ne discharge for pressure from 10 [mTorr] and input RF power 100 [W] to 150 [W]. As for the electron density, a electron temperature was more distinguished for a emission characteristic. The results of ideal may contribute to systematic understanding of a electrodeless fluorescent lamps of emission characteristics.

  • PDF

13.56MHz ICP에서 단일 탐침법에 의한 Ar, Ne 가스의 발광특성 연구 (A Study on Emission Characteristics of Ar, Ne Gas Using a Single Langmuir Probe Method in Radio-Frequency Inductively Coupled Plasma)

  • 조주웅;최용성;김용갑;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.167-170
    • /
    • 2004
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. The electrodeless fluorescent lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. In this paper, electron temperature and electron density were measured in a radio-frequency inductively coupled plasma using a Langmuir probe method for emission characteristics. Measurement was conducted in an Argon, Ne discharge for pressure from 1 [mTorr] and input RF power 10 [W] to 150 [W]. As for the electron density, a electron temperature was more distinguished for a emission characteristic. The results of ideal may contribute to systematic understanding of a electrodeless fluorescent lamps of emission characteristics.

  • PDF

유도결합형 플라즈마에서의 아르곤 가스의 광 효율 (Luminance Efficacy of Inductively Coupled Argon Plasma)

  • 이영환;백광현;최용성;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.299-301
    • /
    • 2004
  • Inductively coupled plasma is commonly used for electrodeless lamp due to its ease of plasma generation. Optical characteristics significantly depend on the RF power and gas pressure of the plasma. This paper describes the measurement of luminous efficacy as a function of RF power and gas pressure with a goal of finding optimal operating conditions of the electrodeless lamp. The gas pressure was varied from 10 [mTorr] to 100 [mTorr] and the RF power was varied from 10 [W] to 120 [W]. It was found that the luminous flux tends to be decreased when argon pressure is increased, and the luminous flux is increased as RF fewer is increased. It was also found that the luminance efficacy is high when the argon pressure is low and when the RF power is low.

  • PDF

국내외 전구형 무전극 형광등 시스템의 특성 비교 분석 (Comparative Analysis on Characteristics of the Circular type Electrodeless Fluorescent Lamp System)

  • 조미령;신상욱;이세현;황명근;김영욱;함중걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.157-160
    • /
    • 2004
  • In this paper, we measured the electrical and optical characteristics of an electrodeless fluorescent lamp system as product from the inside and outside of the country and compared the measured data. Output current wave of domestic 85W is unstable than it's of QL 85 W and the former of spend time after discharging and output current value is larger than the latter. Moreover optical characteristics(brightness, flux, efficiency) value of the former is small than the latter but color rendering index is equivalent. In conclusion, if we improve a little more quality then we must secure the superiority in competition.

  • PDF

유도결합형 플라즈마에서의 Ne, Ar, Kr 혼합가스 방전특성 (Inductively Coupled Plasma discharge characteristic of Ne, Ar, Kr mixed gas)

  • 허인성;최용성;이종찬;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.306-309
    • /
    • 2004
  • Recently, the environmental problem has received considerable attention. so, many lamps have been developing for environmental requirement and energy efficiency. also, at glow discharge lamp researchers try to reduce energy spending that is power saving lamp. this kind requirement agree with strong points of electrodeless fluorescent lamp has received to now lighting sauce. At low pressure as mTorr I.C.P make high density plasma easily, is good to maintain discharge, has high ionization and does not have failing lighting and losing ability of electron radiation by oxidation and volatilization of electrodes, because this tape does not have electrodes. This point of I.C.P can use at electrodeless fluorescent lamp in this study ICP display elements and Ar, Ne, Kr are researched for optical characteristic. each gas is looked into optical characteristic, also mixed gases is experiment for optical characteristic.

  • PDF

무전극형광램프 ULTRA 150W용 EMI 필터에 대한 연구 (A Study on EMI Filters' construction of 150W Electrodeless fluorescent lamp UTLRA's Ballasts)

  • 박석인;한수빈;유승원;송유진;정학근;정봉만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.217-221
    • /
    • 2006
  • Offline switching Power supplies have high voltage and high current switching waveforms that generate Electromagnetic Interference(EMI) in the form of both conducted and radiated emissions. Consequently, all off-line power supplies must be designed to attenuate or suppress EMI emissions below commonly acceptable limits. Electrodeless fluorescent lamp's ballasts have AC/DC flyback converter, so we must control the EMI emissions.

  • PDF

무전극램프 에서의 Hysteresis와 모드 변환 특성 (Hysteresis and Mode Transition in Electrodeless Lamp)

  • 이주호;양종경;이종찬;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1560-1561
    • /
    • 2007
  • Electrodeless fluorescent lamp exhibit two modes of operation : a low density mode in which the power is capacitively coupled to the plasma and which is known as the E-mode, and a higher density mode which is an inductive discharge known as the H-mode. The transition between these two(E to H) mode exhibits hysteresis. It is observed that transition currents change at different frequencies and hysteresis exists not only between the starting and minimum maintaining currents of the electromagnetic mode (H mode) discharge but also between the starting and minimum maintaining currents of the electrostatic mode (E mode) discharge. Hysteresis effect can be important role in dimming system.

  • PDF

고주파 방전 무전극 형광등 광원 기술 [직관 및 환형] (Electrodeless fluorescent Lamp Technology Using High-Frequency Discharges (Linear and Circular Type))

  • 김진중;고정태;원동호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.9-13
    • /
    • 2002
  • 본 과제는 한국 에너지관리공단의 지원으로 고효율의 100-W 급 고주파 방전 형광램프 광원 기술을 개발하는 프로젝트로 경쟁성 있는 원천 기술을 개발하여 기술 이전에 의한 사업화를 궁극적인 목표를 갖고 수행하고 있다. 제 1 차 년도에서는 당초계획보다 앞당겨 형광 램프의 효율을 높이는 실험을 수행하여 일차적으로 괄목할 결과를 얻었다. 기술적으로 유도형+용량형 결합의 혼합형 방전 회로를 채택하여 순수한 용량형 결합 방전에 의한 조도보다 25% 이상의 조도 증가를 성취 하였다. 이 같은 결과는 직관형 및 환형 무전극 형광등에서 정도의 차이는 있으나 같은 경향의 결과를 성취 하였다. 전기적 및 방전 물리의 최적화로 두 경우 다 괄목할 개선을 이룰 수 있을 것이다. 다른 한편으로는 연구개발에 필요한 장비를 사업 종료 후 상품화 기술 개발을 위한 장비로 활용할 수 있도록 시스템 디자인 및 장비 구축도 수행 하였다. 제 2차 년도에서는 1차년도의 긍정적인 결과를 바탕으로 시스템 전반에 걸친 최적화를 기도하고, 상용화에 대비하는 시제품 개발에 정진 할 것이다. 부록에는 연구 개발에 필요한 주요 연구 장비의 성능 및 활용 방법을 첨부 하였다.

  • PDF