• 제목/요약/키워드: Electrode treatment

검색결과 691건 처리시간 0.024초

파라메톡시페놀 및 히이드로퀴논 폐수(廢水)의 전기(電氣) 화학적(化學的) 처리(處理)에 관한 연구(硏究) (A Study on the Electrochemical Treatment of p-methoxyphenol and Hydroquinone Wastewater)

  • 김홍수;남기대;정노희;노윤찬
    • 한국응용과학기술학회지
    • /
    • 제8권2호
    • /
    • pp.153-159
    • /
    • 1991
  • The electrochemical oxidation of p-methoxyphenol and hydroquinone for wastewater treatment application was investigated on platinum anode. At the cyclic voltammetry, it was observed that nagative shift of peak potential of p-methoxyphenol and hydroqinone as the pH of electrolytes increases and the peak current showed higher at strong electrolytes than weak electrolytes. In the case of p-methoxyphenol, the optimum electrode potential of controlled potential electrolysis was observed at the potential region of 0.8-1.0 (V vs. SCE) and hydroquinone was showed at the potential of l.0(V vs. SCE). Specially the oxidation rate of p-methoxyphenol and hydroquinone was showed high value in the acid electrolytes.

Synthesis and Electrochemical Properties of FexNbS2/C Composites as an Anode Material for Li Secondary Batteries

  • Kim, Yunjung;Kim, Jae-Hun
    • Corrosion Science and Technology
    • /
    • 제21권4호
    • /
    • pp.250-257
    • /
    • 2022
  • Transition metal sulfide materials have emerged as a new anode material for Li secondary batteries owing to their high capacity and rate capability facilitated by fast Li-ion transport through the layered structure. Among these materials, niobium disulfide (NbS2) has attracted much attention with its high electrical conductivity and high theoretical capacity (683 mAh g-1). In this study, we propose a facile synthesis of FexNbS2/C composite via simple ball milling and heat treatment. The starting materials of FeS and Nb were reacted in the first milling step and transformed into an Fe-Nb-S composite. In the second milling step, activated carbon was incorporated and the sulfide was crystallized into FexNbS2 by heat treatment. The prepared materials were characterized by X-ray diffraction, electron spectroscopies, and X-ray photoelectron spectroscopy. The electrochemical test results reveal that the synthesized FexNbS2/C composite electrode demonstrates a high reversible capacity of more than 600 mAh g-1, stable cycling stability, and excellent rate performance for Li-ion battery anodes.

Electro-Oxidation in Combination with Biological Processes for Removal of Persistent Pollutants in Wastewater: A Review

  • Navarro-Franco, Javier A.;Garzon-Zuniga, Marco A.;Drogui, Patrick;Buelna, Gerardo;Gortares-Moroyoqui, Pablo;Barragan-Huerta, Blanca E.;Vigueras-Cortes, Juan M.
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권1호
    • /
    • pp.1-18
    • /
    • 2022
  • Persistent organic pollutants (POPs) and emerging pollutants (EP) are characterized by their difficulty to be removed through biological oxidation processes (BOPs); they persist in the environment and could have adverse effects on the aquatic ecosystem and human health. The electro-oxidation (EO) process has been successfully used as an alternative technique to oxidize many kinds of the aforementioned pollutants in wastewater. However, the EO process has been criticized for its high energy consumption cost and its potential generation of by-products. In order to decrease these drawbacks, its combination with biological oxidation processes has been reported as a solution to reduce costs and to reach high rates of recalcitrant pollutants removal from wastewaters. Thus, the location of EO in the treatment line is an important decision to make, since this decision affects the formation of by-products and biodegradability enhancement. This paper reviews the advantages and disadvantages of EO as a pre and post-treatment in combination with BOPs. A perspective of the EO scale-up is also presented, where hydrodynamics and the relationship of A/V (area of the electrode/working volume of the electrochemical cell) experiments are examined and discussed.

출력 커패시터가 없는 위상천이 풀브릿지 컨버터의 전류 전향 보상을 이용한 출력 전압 제어 기법 (Output Voltage Control Technique Using Current Forward Compensation for Phase Shifted Full Bridge Converter Without Output Capacitor)

  • 신유승;백승우;김학원;조관열;강정원
    • 전력전자학회논문지
    • /
    • 제27권1호
    • /
    • pp.40-47
    • /
    • 2022
  • At present, the low-voltage, high-current type power supply is mainly used for effective sterilization in the ballast water treatment system. Research on PSFB converters without output capacitors has been ongoing. Such converters effectively treat ballast water without a separate disinfectant through electric pulses by applying a pulse-type power to the output electrode without an output capacitor. However, in the case of the pulse-type electrolysis treatment method, voltage overshoot can occur due to abrupt voltage fluctuations when the load changes, resulting in circuit reliability problems because of the output capacitorless system. Therefore, a new voltage control algorithm is required. In this paper, we will discuss voltage control for pulsed electrolysis topology without an output capacitor. The proposed voltage control method has been verified using Simulation and experiment. The usefulness of the proposed control method has been proven by the experimental results.

Percutaneous Radiofrequency Facet Rhizotomy for Cervical Dorsal Ramus Syndrome

  • Cho, Tack-Geun;Hwang, Sung-Nam;Park, Seung-Won;Nam, Taek-Kyun;Hong, Hyun-Jong;Kim, Young-Baeg
    • Journal of Korean Neurosurgical Society
    • /
    • 제40권6호
    • /
    • pp.419-422
    • /
    • 2006
  • Objective : Radiofrequency facet rhizotomy[RFFR] has been widely performed for treatment of chronic neck pain caused by cervical dorsal ramus syndrome[CDRS]. To evaluate the therapeutic effectiveness of RFFR in the patients with CDRS, we analyzed patients with various cervical pathologic conditions. Methods : The therapeutic results in forty-four patients who underwent RFFR for CDRS from January, 2000 to December, 2002 were analyzed according to the underlying pathologic conditions causing CDRS. The pathologic conditions were sprain [33 cases], herniated nucleus pulposus [6], foraminal stenosis [4], and compression fracture [1]. The therapeutic results were evaluated one month after the operation and graded as excellent, good, fair of poor. Treatments were considered successful if the therapeutic results were graded as either excellent of good. Results : The overall success rate in all patients was 72.7%. The success fate for treatment of cases with cervical sprain was 87.9%, but treatment of cases with herniated nucleus pulposus, foraminal stenosis, and fracture showed unsatisfactory results [mean success rate was 27.3%]. Some patients complained of transient hypesthesia [4 cases] of transient dull pain at the electrode insertion sites [2 cases]. Conclusion : RFFR is an effective and safe treatment for CDRS caused by cervical sprain, regardless of the patient's age, the duration of the symptoms, and the presence of radiating pain.

마이크로웨이브를 이용한 고분자 전해질 연료전지용 복합 탄소 촉매 지지체 (ACF/Graphene)의 합성과 전기화학적 거동 (Synthesisand Electrochemical Behaviors of Hybrid Carbon (ACF/Graphene) as Supports by Microwaves-irradiation Method for Polymer Exchange Membrane Fuel Cells (PEMFC))

  • 조용일;전유권;박대환;전소미;김태언;오경석;설용건
    • 한국수소및신에너지학회논문집
    • /
    • 제24권2호
    • /
    • pp.142-149
    • /
    • 2013
  • Carbon materials are mainly used as catalyst supports for polymer exchange membrane fuel cell (PEMFC). Catalyst supports are required specific characteristics of the carbon materials, such as large surface area and high electrical conductivity. Attempted were to improve electrical conductivity and to maintain high surface area of carbon materials using a microwave treatment. Microwave treatment, as a relatively new technique, takes short reaction time and reduce the consumption of the gases used for carbon treatment compared to a traditional heat treatment. Hybrid carbon (ACF/Graphene) as catalyst supports by microwave-irradiation method for PEMFC increase the cell performance because of increased electrical conductivity resulting in triple-phase contact and reduced the interfacial resistance. Scanning electron microscopy (SEM), transmission electron microscopy (TEM) and X-Ray Diffraction (XRD) were employed to analyze carbon materials. The performance of microwave-treated carbon materials was evaluated by measuring current-voltage (I-V) characteristics and electrode impedance.

코로나 방전 플라즈마를 이용한 화산암재 분말 살균 (Sterilization of Scoria Powder by Corona Discharge Plasma)

  • 조진오;이호원;목영선
    • 공업화학
    • /
    • 제25권4호
    • /
    • pp.386-391
    • /
    • 2014
  • 본 연구에서는 상압 저온 코로나 방전 플라즈마를 화산암재(스코리아) 분말의 살균에 적용하였다. 스코리아 분말에 Escherichia coli (E. coli) 배양액을 살포하여 균일하게 혼합한 후, 코로나 방전 플라즈마 특성 인자인 방전전력, 방전시간, 주입기체, 전극간격 등의 조건을 변화시키며 E. coli 살균효율을 조사하였다. 실험 결과 상압 저온 코로나 방전 플라즈마는 분말상의 스코리아 살균에 아주 효과적인 것으로 나타났으며, 방전전력 15 W에서 5 min 동안 살균한 결과 E. coli가 99.9% 이상 사멸하였다. 방전전력, 방전시간, 인가전압이 증가할수록 사멸율이 향상되었다. 반응기에 주입되는 기체의 종류에 따른 살균력 실험 결과, 산소 > 모사공기(산소 20%) > 질소 순으로 나타났다. 코로나 방전 플라즈마에 의한 E. coli 살균은 자외선과 활성산화종(산소라디칼, OH라디칼, 오존 등)에 의한 세포막 침식 및 에칭, 그리고 플라즈마 방전 스트리머에 의한 대장균 세포막 파괴로 설명할 수 있다.

의사소통장애인의 조음치료를 위한 한국형 전자구개도의 구현 (Preliminary study of Korean Electro-palatography (EPG) for Articulation Treatment of Persons with Communication Disorders)

  • 우승탁;박영빈;오다희;하지완
    • 센서학회지
    • /
    • 제28권5호
    • /
    • pp.299-304
    • /
    • 2019
  • Recently, the development of rehabilitation medical technology has resulted in an increased interest in speech therapy equipment. In particular, research on articulation therapy for communication disorders is being actively conducted. Existing methods for the diagnosis and treatment of speech disorders have many limitations, such as traditional tactile perception tests and methods based on empirical judgment of speech therapists. Moreover, the position and tension of the tongue are key factors of speech disorders with regards to articulation. This is a very important factor in the distinction of Korean characters such as lax, fortis, and aspirated consonants. In this study, we proposed a Korean electropalatography (EPG) system to easily measure and monitor the position and tension of the tongue in articulation treatment and diagnosis. In the proposed EPG system, a sensor was fabricated using an AgCl electrode and biocompatible silicon. Furthermore, the measured signal was analyzed by implementing the bio-signal processing module and monitoring program. In particular, the bio-signal was measured by inserting it into the palatal from an experimental control group. As a result, it was confirmed that it could be applied to clinical treatment in speech therapy.

스테인레스 강의 수전해 전극 응용기술 동향 (Technology Trends in Stainless Steel for Water Splitting Application)

  • 김문수;하재윤;김용태;최진섭
    • 전기화학회지
    • /
    • 제24권2호
    • /
    • pp.13-27
    • /
    • 2021
  • 스테인레스 강은 지구상에서 가장 널리 사용되고 있는 철의 합금으로 니켈과 크롬을 포함하여 높은 내부식성을 가지고 있어 구조용 강재로 사용하기 매우 적합하다. 또한, 최근에는 스테인레스 강에 포함된 철과 니켈의 고유 특성을 이용하여 다양한 고기능성 촉매나 지지체, 또는 전극의 집전체 등으로의 응용 연구가 다양하게 이루어지고 있다. 특히, 높은 촉매 특성으로 인해 수전해 전극으로의 응용을 위한 스테인레스 강의 표면에서의 활성화 표면 처리 연구가 많이 이루어지고 있다. 이에 본 총설은 수전해 전극 응용을 위한 스테인레스 강의 수전해 전극 응용 표면처리 기술 자료를 정리 및 요약하였으며, 스테인레스 강의 표면처리 방법에 대한 특징 및 이를 통해 스테인레스 강이 저비용 고효율의 수전해 전극 활용을 위한 촉매 물질로써 응용될 수 있는 여러 방법을 제시하였다.

레이저 조사 전후 자궁경부조직의 상대적 전기물성 스펙트럼 변화를 이용한 자궁경부 이형성증 치료검증도구의 가능성 평가 (Feasibility Study of a Verification Tool for the Treatment of Cervical Intraepithelial Neoplasia Using Relative Electrical Property Change Before and After Laser Irradiation)

  • 허준범;;오동인;박동춘
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권6호
    • /
    • pp.409-416
    • /
    • 2022
  • Since the detection of cervical intraepithelial neoplasia (CIN) is increasing due to regular cervical cancer screening, there is a high demand for simpler tools to diagnose and treat CIN in the clinic. In this study, we proposed an electric property of cervical tissue to verify treatment using a laser. At first, we observed the depth and width of ablated cervical tissues for 29 samples according to four different pulse energy of the fractional CO2 laser to find enough pulse energy to reach the basement layer for initiated CIN. And then, the relative frequency differences in impedance spectrum before and after laser irradiation for ten non-CIN samples were collected using bioimpedance spectroscopy with a multi-electrode probe. As a result, the laser ablated the cervical tissues with a depth of more than 300 ㎛ at 100 mJ pulse energy. Also, we confirmed that the relative changes of electrical property for cervical tissue increased as the pulse energy of laser output increased, and the variation between samples decreased. Since the relative change in electrical properties of cervical tissue can be easily and quickly measured, the proposed technique paves the way for further verification and follow-up study of laser treatment for CIN.