• Title/Summary/Keyword: Electrode array

Search Result 224, Processing Time 0.025 seconds

Carbon Nanotubes Multi Electrodes Array to Image Capacitance for Label-free Discrimination of Lipid Region in Atherosclerosis ex vivo

  • Song, Jun-Ho;Lee, Seon-Mi;Han, Nal-Ae;Yu, Gyeong-Hwa
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.372.1-372.1
    • /
    • 2016
  • Recently, there are a lot of diseases all around the world. Out of them, Atherosclerosis (AS) is the most common cause of stroke, cardiovascular mortality, and myocardial infarction. The macrophage-derived foam cell, which is formed by oxidized low-density lipoprotein (oxLDL), is the crucial marker for AS. In this study, we report a label-free capacitance imaging technique with multi-electrode array (MEA). The lipid-rich aorta arch lesions, which are derived from an apolipoprotein-E receptor-deficient (apoE-/-) mouse, exhibit higher capacitance than the lipid-free aorta arch, allowing the capacitance imaging of lipid region in atherosclerosis. To improve the contacts between MEA and tissue, polypyrrole(PPy)-coated multi walled carbon nanotubes (MWNTs) multi electrode array (PPy-MWNTs-MEA) was fabricated. Compared to TiN-MEA, PPy-MWNTs-MEA yielded lower contact impedance and better capacitance images. In addition, we have also developed a flexible MEA using single walled carbon nanotubes on a PET substrate. The lipid region could be discriminated in the capacitance images of the lipid-rich aorta arch lesions measured using flexible MEA, demonstrating a feasibility of in vivo applications.

  • PDF

Electrochemical Activity of a Blue Anatase TiO2 Nanotube Array for the Oxygen Evolution Reaction in Alkaline Water Electrolysis

  • Han, Junhyeok;Choi, Hyejin;Lee, Gibaek;Tak, Yongsug;Yoon, Jeyong
    • Journal of Electrochemical Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.76-81
    • /
    • 2016
  • An anatase TiO2 nanotube array (NTA) was fabricated by anodization and successive heat treatments. When the anatase TiO2 NTA was cathodically polarized, its color changed to blue, and it could be used as an electrochemically active anode for an oxygen evolution reaction (OER) in alkaline water electrolysis. The structure of the blue anatase TiO2 NTA was controlled by the anodization conditions and its catalytic activity increased with an increase of the surface area. The activity of the blue anatase TiO2 NTA gradually reduced with the continued OER because of the partial oxidation of Ti3+ to Ti4+. However, an intermittent cathodic regeneration process could significantly slow its reduction rate. The blue anatase TiO2 NTA could be an alternative anode for alkaline water electrolysis.

The fabrication of Pt electroplating on ITO multi-electrode array in neuronal signal detection (전극의 임피던스 감소를 위해 백금 도금한 ITO 신경신호 검출용 다중 전극 제작)

  • Kwon, Gwang-Min;Choi, Joon-Ho;Lee, Kyoung-J.;Pak, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.257-259
    • /
    • 2002
  • In investigating the characteristics of a neural network, the use of planar microelectrode array shows several advantages over normal intracellular recording[1]. A transparent indium tin oxide(ITO) multi-electrode array(MEA) was fabricated and its top surface was insulated with photodefinable polyimide(HD-8001) except the exposed area for interfacing between the ITO electrodes and the neuronal cells. The exposed ITO electrodes were platinized in order to reduce the impedance between the electrodes and electrolyte. The one-minute platinization with $0.99nA/{\mu}m^2$ current density reduced the average impedance of the electrodes from $2.5M\Omega\;to\;90k\Omega$ at 1kHz in normal ringer solution. Cardiac cells were cultured on this MEA as a pilot study before neuron culture. The signals detected by the platinized electrodes had larger amplitudes and improved signal to noise ratio(SNR) compared to non-platinized electrodes. It is clear that microelectrodes need to have lower impedance to make reliable extracellular recordings, and thus platinization is essential part of MEA fabrication. Burst spike of cultured olfactory bulb was also detected with the MEA having platinized electrodes.

  • PDF

Enhancement of Light Extraction from Transparent OLED Lighting Panels (투명 OLED 면광원 광 추출 향상 기술)

  • Park, June Buem;Shin, Dong-Kyun;Han, Seun Gjo;Park, Jong-Woon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.4
    • /
    • pp.41-45
    • /
    • 2017
  • We have investigated the light extraction efficiency of large-area OLED lighting panels with a microlens array (MLA) or external scattering layer (ESL) by ray tracing simulation. The application of MLA and ESL to transparent OLEDs (TOLEDs) with an auxiliary metal electrode is also studied. It is found that MLA shows higher light extraction efficiency, compared with ESL. However, we have demonstrated that ESL is more suitable for TOLEDs having dual-sided equal light emission. Namely, equal light emission from the front and rear surfaces of TOLED can be achieved by increasing the scattering particle density of ESL. To compensate for a loss in light emission induced by auxiliary metal electrode, we come out with an OLED structure partially covered with MLA at the outer surface of glass substrate, which is aligned with metal electrode. With this scheme, it is observed that the light extraction efficiency can be boosted more than 20% from opaque OLED and 50% from transparent OLED.

  • PDF

FE model of electrical resistivity survey for mixed ground prediction ahead of a TBM tunnel face

  • Kang, Minkyu;Kim, Soojin;Lee, JunHo;Choi, Hangseok
    • Geomechanics and Engineering
    • /
    • v.29 no.3
    • /
    • pp.301-310
    • /
    • 2022
  • Accurate prediction of mixed ground conditions ahead of a tunnel face is of vital importance for safe excavation using tunnel boring machines (TBMs). Previous studies have primarily focused on electrical resistivity surveys from the ground surface for geotechnical investigation. In this study, an FE (finite element) numerical model was developed to simulate electrical resistivity surveys for the prediction of risky mixed ground conditions in front of a tunnel face. The proposed FE model is validated by comparing with the apparent electrical resistivity values obtained from the analytical solution corresponding to a vertical fault on the ground surface (i.e., a simplified model). A series of parametric studies was performed with the FE model to analyze the effect of geological and sensor geometric conditions on the electrical resistivity survey. The parametric study revealed that the interface slope between two different ground formations affects the electrical resistivity measurements during TBM excavation. In addition, a large difference in electrical resistivity between two different ground formations represented the dramatic effect of the mixed ground conditions on the electrical resistivity values. The parametric studies of the electrode array showed that the proper selection of the electrode spacing and the location of the electrode array on the tunnel face of TBM is very important. Thus, it is concluded that the developed FE numerical model can successfully predict the presence of a mixed ground zone, which enables optimal management of potential risks.

A Study on Integrated Multimicroelectrode Array (집적회로형 다중 초미소 전극 배예에 관하여)

  • ;Bel
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.6
    • /
    • pp.58-64
    • /
    • 1980
  • A new type of multimicroelectrode array has been developed using integrated circuit technology in order to record action potentials from nervous systems. The size and pattern of the electrode array are determined accurately in a frow $\mu$m range by optical photolithogaphy. The electrical characteristics of the integrated microelectrode array were investigated. The practical applications of this electrode array in recording action potentials from a ventral nerve of a cockroach are shown.

  • PDF

A New Strategy to Fabricate a Colloidal Array Templated $TiO_2$ Photoelectrode for Dye-sensitized Solar Cells

  • Lee, Hyeon-Jeong
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.8.1-8.1
    • /
    • 2011
  • Nanocrystalline titanium dioxide ($TiO_2$) materials have been widely used as an electron collector in DSSC. This is required to have an extremely high porosity and surface area such that the dye can be sufficiently adsorbed and be electronically interconnected, resulting in the generation of a high photocurrent within cells. In particular, their geometrical structures and crystalline phase have been extensively investigated as important issues in improving its photovoltaic efficiency. In this study, we present a new strategy to fabricate a photoelectrode having a periodic structured $TiO_2$ film templated from 1D or 3D polystyrene (PS) microspheres array. Monodisperse PS spheres of various radiuses were used for colloidal array on FTO glasses and two types of photoelectrode structures with different $TiO_2$ materials were investigated respectively. One is the igloo-shaped electrode prepared by $TiO_2$ deposition by RF-sputtering onto 2D microsphere-templated substrates. At the interface between the film and substrate, there are voids formed by the decomposition of PS microspheres during the calcination step. These holes might be expected to play the predominant roles as scattering spherical voids to promote a light harvesting effect, a spacious structure for electrolytes with higher viscosity and effective paths for electron transfer. Additionally the nanocrystalline $TiO_2$ phase prepared by the RF-sputtering method was previously reported to improve the electron drift mobility within $TiO_2$ electrodes. This yields solar cells with a cell efficiency of 2.45% or more at AM 1.5 illumination, which is a very remarkable result, considering its $TiO_2$ electrode thickness (<2 ${\mu}m$). This study can be expanded to obtain higher cell efficiency by higher dye loading through the increase of surface area or multi-layered stacking. The other is the inverse opal photonic crystal electrode prepared by titania particles infusion within 3D colloidal arrays. To obtain the enlargement of ordered area and high quality of crystallinity, the synthesis of titania particles coated with a organic thin layer were applied instead of sol-gel process using the $TiO_2$ precursors. They were dispersed so well in most solvents without aggregates and infused successfully within colloidal array structures. This ordered mesoporous structure provides the large surface area leading to the enough adsorption of dye molecules and have an light harvesting effect due to the photonic band gap properties (back-and-forth reflection effects within structures). A major advantage of this colloidal array template method is that the pore size and its distribution within $TiO_2$ photoelectrodes are determined by those of latex beads, which can be controlled easily. These materials may have promising potentials for future applications of membrane, sensor and so on as well as solar cells.

  • PDF

Fabrication and Characterization of MEA (MEA의 제작 및 특성 평가)

  • Seong, Nak-Seon;Pak, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.11d
    • /
    • pp.857-859
    • /
    • 2000
  • A planar MEA(Multi-channel Electrode Array) has been developed for monitoring the electrical activity of electrogenic cells in a cell culture by an extracellular recording. The material, fabrication process, characterization of the array, cleaning effect and impedance according to opening size by impedance measurement are described.

  • PDF

Discriminant Analysis of Marketed Liquor by a Multi-channel Taste Evaluation System

  • Kim, Nam-Soo
    • Food Science and Biotechnology
    • /
    • v.14 no.4
    • /
    • pp.554-557
    • /
    • 2005
  • As a device for taste sensation, an 8-channel taste evaluation system was prepared and applied for discriminant analysis of marketed liquor. The biomimetic polymer membranes for the system were prepared through a casting procedure by employing polyvinyl chloride, bis (2-ethylhexyl)sebacate as plasticizer and electroactive materials such as valinomycin in the ratio of 33:66:1, and were separately attached over the sensitive area of ion-selective electrodes to construct the corresponding taste sensor array. The sensor array in conjunction with a double junction reference electrode was connected to a high-input impedance amplifier and the amplified sensor signals were interfaced to a personal computer via an A/D converter. When the signal data from the sensor array for 3 groups of marketed liquor like Maesilju, Soju and beer were analyzed by principal component analysis after normalization, it was observed that the 1st, 2nd and 3rd principal component were responsible for most of the total data variance, and the analyzed liquor samples were discriminated well in 2 dimensional principal component planes composed of the 1st-2nd and the 1st-3rd principal component.

Development of High-Definition PDP TV with High-Efficient Hexagonal Array Structure

  • Lee, Byung-Hak;Heo, Eun-Gi;Yoon, Cha-Keun;Lee, Kwang-Sik;Cho, Yoon-Hyoung;Yoo, Min-Sun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.347-350
    • /
    • 2003
  • Optimization of the luminance, luminous efficiency, and address voltage margin characteristics has been made on the delta color array PDP with various hexagonal shape subpixels. The optimal subpixel and electrode designs are obtained for the 42-inch high-definition PDP ($1,366{\times}768$) with the fine pixel pitch less than 0.7 mm. The hexagonal delta array structure shows more improved characteristics than that of the normal delta array structure with rectangular shape subpixels.

  • PDF