• Title/Summary/Keyword: Electrode System

검색결과 1,768건 처리시간 0.033초

Polydimethylsiloxane 채널과 indium tin oxide 전극을 이용한 일회용 전기화학적 검출 시스템 (Disposable Microchip-Based Electrochemical Detector Using Polydimethylsiloxane Channel and Indium Tin Oxide Electrode)

  • 이인제;강치중;김용상;김주호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.227-231
    • /
    • 2005
  • We have developed a microsystem with a capillary electrophoresis (CE) and an electrochemical detector (ECD). The microfabricated CE-ECD systems are adequate for a disposable type and the characteristics are optimized for an application to the electrochemical detection. The system was realized with polydimethylsiloxane (PDMS)-glass chip and indium tin oxide electrode. The injection and separation channels (80 um wide$\ast$40 um deep) were produced by moulding a PDMS against a microfabricated master with relatively simple and inexpensive methods. A CE-ECD systems were fabricated on the same substrate with the same fabrication procedure. The surface of PDMS layer and ITO-coated glass layer was treated with UV-Ozone to improve bonding strength and to enhance the effect of electroosmotic flow. For comparing the performance of the ITO electrodes with the gold electrodes, gold electrode microchip was fabricated with the same dimension. The running buffer was prepared by 10 mM 2-(N-morpholino)ethanesulfonic acid (MES) titrated to PH 6.5 using 0.1 N NaOH. We measured olectropherograms for the testing analytes consisted of catechol and dopamine with the different concentrations of 1 mM and 0.1 mM, respectively. The measured current peaks of dopamine and catechol are proportional to their concentrations. For comparing the performance of the ITO electrodes with the gold electrodes, electropherograms was measured for CE-ECD device with gold electrodes under the same conditions. Except for the base current level, the performances including sensitivity, stability, and resolution of CE-ECD microchip with ITO electrode are almost the same compared with gold electrode CE-ECD device. The disposable CE/ECD system showed similar results with the previously reported expensive system in the limit of detection and peak skew. When we are using disposable microchips, it is possible to avoid polishing electrode and reconditioning.

동축형 전극길이 변화시의 연면무성방전에 의한 오존발생특성(I) (Ozone Generation Characteristics by Surface-Silent Discharge According to the Length of Coaxial Electrode)

  • 조국희;김영배;서길수;이형호;이상근;이광식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권12호
    • /
    • pp.791-797
    • /
    • 1999
  • Recently the ozone generation system is well used for cleaning the contaminated water by using the strong oxidization effects of ozone. In this paper the concentration, yield and generation quantity of the ozone by the Surface-Silent Discharge According to the Length of Coaxial Electrode is described. The electrodes composed of 3 electrodes-2 gaps are coaxial type and the ozone generation tube were designed and fabricated from the point of view of the energy efficiency, stability and easy control. To investigate the ozone generation dependency on electrode length, a few discharge tubes with different lengths were fabricated. The experimental equipments were provided with cooling system and dehumidifier for the many testing conditions. The main results show that the concentration, yield and generation quantity of ozone are improved by decreasing gas temperatures and increasing electrode lengths.

  • PDF

Effects of Intramuscular Electrical Stimulation Using Inversely Placed Electrodes on Myofascial Pain Syndrome in the Shoulder - A Case Series

  • Shanmugam, Sukumar;Mathias, Lawrence;Thakur, Ajay;Kumar, Dhanesh
    • The Korean Journal of Pain
    • /
    • 제29권2호
    • /
    • pp.136-140
    • /
    • 2016
  • Myofascial pain syndrome (MPS) is one of the common musculoskeletal conditions of the shoulder which may develop sensory-motor and autonomic dysfunctions at the various level of the neuromuscular system. The pain and dysfunction caused by MPS were primarily treated with physical therapy and pharmacological agents in order to achieve painfree movements. However, in recent years intramuscular electrical stimulation (IMES) with conventional electrode placement was used by researchers to maximise therapeutic values. But, in this study an inverse electrode placement was used to deliver electrical impulses intramuscularly to achieve neuro-modulation at the various level of the nervous system. Nine patients with MPS were treated with intramuscular electrode stimulation using inversely placed electrodes for a period of three weeks. All nine subjects recovered from their shoulder pain and disability within the few weeks of intervention. So, this inverse electrode placement may be more appropriate for chronic pain management.

출탕유도전극을 이용한 용융물의 출탕방법 및 특성에 대한 연구 (A Study on the Properties and Methods of Electrode System for Tapping of Melts)

  • 문영표;최장영
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.499-503
    • /
    • 2016
  • For safety and economy reasons, hazardous waste including radioactive waste is desired to be converted into stable waste forms with a maximum volume reduction. High temperature melting technology using a plasma torch system can effectively treat even the non-flammable waste as desired. By far, one of the most difficult process for melting the non-flammable waste is a tapping of melts because the melting point of a residual slag in the tapping hole is high and because the viscosity of the melt increases sharply when tapping out. In case of a stationary furnace with a slant tapping port on the side of furnace, a certain amount of melts is left in the tapping hole after tapping out. Because of this, at every end of a melting cycle, the tapping hole needs to be opened by tapping device. The developed tapping device of melts based on both a guide electrode and auxiliary electrode is adequate for the application to discharge of melts except that the consumption of the guide electrode is somewhat faster than expected. Melt is collected in the water cooled vessel.

코아링 접지전극의 경년변화 해석 (Analysis on Coring Earth Electrode in Progress of Time)

  • 오성보;김세호;김호찬;부창진;안재현;고성민;고영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.89-90
    • /
    • 2006
  • Recent earth systems not only make earth resistance decreased by installing earth electrode but also are demanded by earth construction for the protection of human life and equipments through total investigation about circumstances. Layer constructions in Jeju island consist of multi-layer of scoria, rocks and shale except clay layers on the surface, which needs the construction of the coring earth electrode suitable in the condition of the area. For this reason, we've used the coring earth electrode. But the coring earth electrode is expected to slow down the performance of this equipment according to the progress of time changing the effects. It is also applied for the stability of earth system construction and management after the construction work analyzing the condition of the earth system. Therefore, this is actually focused on the analysis on measuring the earth resistance and the soil resistivity that cover the range where the remarkable contrast can be expected to be seen in the layer structures.

  • PDF

Caudal Neuromodulation with the Transforaminal Sacral Electrode (InterStim): Experience in a Pain Center Regarding 12 Implants

  • Guardo, Laura Alonso;Gala, Carlos Cano;Poveda, David Sanchez;Juan, Pablo Rueda;Sanchez Montero, Francisco Jose;Garzon Sanchez, Jose Carlos;Lamas, Juan Ignacio Santos;Sanchez Hernandez, Miguel Vicente
    • The Korean Journal of Pain
    • /
    • 제29권1호
    • /
    • pp.23-28
    • /
    • 2016
  • Background: Sacral nerve stimulation is a therapeutic option with demonstrated efficacy for conditions presenting with perineal pain caused by different etiologies. We aimed to assess whether a sacral electrode ($Interstim^{(R)}$, Medtronic, Minneapolis, MN, USA) inserted through the caudal pathway is able to offer an acceptable level of sacral stimulation and rate of catheter migration. Methods: We present 12 patients with pelvic pain who received sacral neuromodulation via the sacral hiatus with the InterStim electrode. We evaluated patient satisfaction as well as migration and removal of the electrode, if necessary. Results: Our experience included 12 patients, 10 women and two men, with a mean age of 60 years. In eight of the 12 patients, the initial therapy was effective, and the final system implantation was performed. During subsequent follow-up, patient satisfaction was good. To date, there have been no cases of electrode displacement or migration. Conclusions: The caudal insertion of the InterStim electrode, with its own fixation system, and initially designed for transsacral insertion, appears in our experience to be a satisfactory option which can minimize electrode displacements, achieving similar results in therapeutic efficacy and causing no difficulties in removal.

해수전해장치 전해조 개선에 의한 전극 부착물 저감 (Reduction of Deposits on the Electrode by the Cell Modification in Direct Sea Water Electrolysis System)

  • 박승수;김기형;안희수;박광규;이태원
    • 공업화학
    • /
    • 제16권4호
    • /
    • pp.563-569
    • /
    • 2005
  • 발전소에서 운영하고 있는 해수전해장치의 전극에 부착물이 다량으로 부착하여 성능이 저하되고 전극 손상사고가 발생하고 있어 전극 부착물을 억제할 수 있는 방안을 연구하였다. 현재 사용하고 있는 grating type의 양극을 plate type으로 변경하고 양극판 수를 9매에서 8매로 줄이는 한편, 전극 간격을 2.4 mm에서 3.0 mm로 늘리고, 극간 간격을 유지하기 위한 스페이서를 27개에서 10개로 줄인 전해조를 개발하였다. 발전소 현장에 개발 전해조를 설치하여 성능을 시험한 결과 기존의 제품에 비하여 전류효율은 15~20% 높았고, 전극 부착물은 36~60% 감소하였으며, 전력소비율은 20% 정도 낮은 것으로 나타났다.

미생물막 전극을 이용한 BOD 자동화 측정장치 (Automatic On-line BOD Measurement System Using A Microbial Membrane Electrode)

  • 오혁;김해동
    • 분석과학
    • /
    • 제8권3호
    • /
    • pp.335-340
    • /
    • 1995
  • Bacillus subtilis와 PVA를 사용한 미생물막 전극을 이용하여 수질시료의 생화학적 산소요구량(BOD)을 측정할 수 있는 BOD 자동화 측정장치를 개발하였다. 본 연구에서 개발한 BOD 자동화 측정장치는 glucose/glutamic acid BOD 표준용액을 사용시 60ppm까지 직선적인 감응을 나타내었으며, 시료주입 후 10분 이내에 자동으로 BOD 측정기능을 수행하였다. Bacillus subtilis와 PVA를 사용한 미생물막 전극의 감응시간과 회복시간은 각각 5분이었으며, BOD 측정 정장치의 자동화에 의하여 10% 오차내에서 재현성 있는 결과를 얻을 수 있었다.

  • PDF

생체 임피던스를 이용한 인체 하지운동 출을 위한 최적 전극위치 선정 (Optimal Electrode Selection for Detection of Human Leg Movement Using Bio-Impedance)

  • 송철규;윤대영;이동헌;김승찬;김덕원
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권8호
    • /
    • pp.506-509
    • /
    • 2003
  • This paper describes the possibility of analyzing gait pattern from the changes of the lower leg electrical impedance. This impedance was measured by the four-electrode method. Two current electrodes were applied to the thigh, knee, and foot., and two potential electrodes were applied to the lateral, medial, and posterior position of human leg. The correlation coefficients of the joint angle and the impedance change from human leg movement was obtained using a electrogoniometer and 4ch impedance measurement system developed in this study. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. The correlation coefficients of the ankle, knee, and the hip movements were -0.913, 0.984 and 0.823, respectively. From such features of the human leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level. This system showed feasibility that lower leg movement could be easily measured by impedance measurement system with a few skin-electrodes.

Modeling and performance evaluation of a piezoelectric energy harvester with segmented electrodes

  • Wang, Hongyan;Tang, Lihua;Shan, Xiaobiao;Xie, Tao;Yang, Yaowen
    • Smart Structures and Systems
    • /
    • 제14권2호
    • /
    • pp.247-266
    • /
    • 2014
  • Conventional cantilevered piezoelectric energy harvesters (PEHs) are usually fabricated with continuous electrode configuration (CEC), which suffers from the electrical cancellation at higher vibration modes. Though previous research pointed out that the segmented electrode configuration (SEC) can address this issue, a comprehensive evaluation of the PEH with SEC has yet been reported. With the consideration of delivering power to a common load, the AC outputs from all segmented electrode pairs should be rectified to DC outputs separately. In such case, theoretical formulation for power estimation becomes challenging. This paper proposes a method based on equivalent circuit model (ECM) and circuit simulation to evaluate the performance of the PEH with SEC. First, the parameters of the multi-mode ECM are identified from theoretical analysis. The ECM is then established in SPICE software and validated by the theoretical model and finite element method (FEM) with resistive loads. Subsequently, the optimal performances with SEC and CEC are compared considering the practical DC interface circuit. A comprehensive evaluation of the advantageous performance with SEC is provided for the first time. The results demonstrate the feasibility of using SEC as a simple and effective means to improve the performance of a cantilevered PEH at a higher mode.