• Title/Summary/Keyword: Electrode System

Search Result 1,773, Processing Time 0.03 seconds

Study of Electrode Cracking in High Voltage Direct Current System (초고압 직류 설비의 전극봉 부식원인에 대한 연구)

  • Park, Jong-Kwang;Kim, Chan-Ki;Yang, Byoung-Mo;Choy, Young-Do;Han, Byeong-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.525-526
    • /
    • 2006
  • One of the electrode in Haenam converter, which is role of rectifier in Jeju-Haenam HVDC system is destroyed and we found many cracks at another electrode and we also found many cracks in Jeju converter station, which is role of inverter of Jeju-Haenam. HVDC system, there is no exact reason for these phenomenon, even though the life cycle of these electrode is 40 years. So, the experts for HVDC system in KEPCO and Anotec corporation, which is manufacturer of electrode, would perform research for the reason of electrode disorder. In this paper analyze the reason of electrode disorder and corrosion in high voltage direct current system.

  • PDF

Fabrication of Electrochemical Sensor with Tunable Electrode Distance

  • Yi, Yu-Heon;Park, Je-Kyun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.5 no.1
    • /
    • pp.30-37
    • /
    • 2005
  • We present an air bridge type electrode system with tunable electrode distance for detecting electroactive biomolecules. It is known that the narrower gap between electrode fingers, the higher sensitivity in IDA (interdigitated array) electrode. In previous researches on IDA electrode, narrower patterning required much precise and expensive equipment as the gap goes down to nanometer scale. In this paper, an improved method is suggested to replace nano gap pattering with downsizing electrode distance and showed that the patterning can be replaced by thickness control using metal deposition methods, such as electroplating or metal sputtering. The air bridge type electrode was completed by the following procedures: gold patterning for lower electrode, copper electroplating, gold deposition for upper electrode, photoresist patterning for gold film support, and copper etching for space formation. The thickness of copper electroplating is the distance between upper and lower electrodes. Because the growth rate of electroplating is $0.5{\mu}m\;min^{-1}$, the distance is tunable up to hundreds of nanometers. Completed electrodes on the same wafer had $5{\mu}m$ electrode distance. The gaps between fingers are 10, 20, 30, and $40{\mu}m$ and the widths of fingers are 10, 20, 30, 40, and $50{\mu}m$. The air bridge type electrode system showed better sensitivity than planar electrode.

Ionic Wind Generation Characteristics of a Water-Pen Point-to-Mesh Type Discharge System (수침대 그물전극형 방전장치의 이온풍 발생특성)

  • Jung, Jae-Seung;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.783-787
    • /
    • 2009
  • A point-to-mesh type discharge system, utilizing a water-pen point as a corona discharge electrode and a mesh as an ion induction electrode, has been proposed, and the effect of the water-pen point electrode of the discharge system to the ionic wind velocity and generation yield was investigated. It was observed that the proposed discharge system with the water-pen point electrode can generate a higher ionic wind velocity as compared with that of the metal point electrode. As a result, the peak ionic wind velocities of 2.61 and 4.05 m/s for the positive and negative corona discharges of the proposed discharge system can be obtained, which are 1.39 and 1.15 times higher than those of the metal point electrode with same design. The ionic wind generation yield of 4.72 m/s/W of the discharge system with the water-pen point electrode was obtained for the positive corona, which was 3.66 times higher than that of the metal point electrode. This enhancement may be due to the effect of the water-pen point electrode.

Study to Analyze the Grounding System in the 20 kHz Power Installation (20 kHz 전력설비 접지시스템 분석에 관한 연구)

  • Jung, Jin-Soo;Han, Woon-Ki;Park, Chan-Urm;Song, Young-Sang;Lim, Hyun-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1308-1312
    • /
    • 2013
  • In this paper, carried out for optimal ground system for ensuring safety for electricity used to power equipment in the 20 kHz frequency. Now the grounding system of the mesh electrode, electrode rods are installed for power plant safety and protection against electric shock. However, the electrical equipment grounding system in the 20 kHz were considering the increasing grounding impedance due to the high frequency and the magnetic shielding. But until now, there has been little research on the grounding system. To solve this problem, In this paper was proposed optimal grounding system due to the experiment using a mesh electrode, rod electrode, aluminum plate electrodes. Measurement results, grounding resistance was depending on the material of the electrode grounding resistance. In addition, the leakage current (induced) appeared to be affected depending on the type of electrode.

Effective Ionic Wind Generation Utilizing a Cylindrical Corona Discharge Electrode (금속관형 코로나 방전극을 적용한 효과적인 이온풍 발생)

  • Jung, Jae-Seung;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.599-603
    • /
    • 2010
  • A point-mesh type corona system has been well used as a ionic wind blower. However this type corona system suffers from its lower ionic wind generation, because of its lower on-set and breakdown voltages of its very sharp needle point corona electrode. This means that the point corona electrode must act both as an effective ion-generator and a very higher electric field producer in the discharge airgap in order to generate higher ionic wind velocity. In this paper, a cylinder-mesh type discharge system as a ionic wind generator is proposed and investigated. The cylindrical corona electrode can produce many ions from its sharpened edge, and the corona on-set and breakdown voltages are very higher than those of the needle point corona electrode. As a result, this type cylindrical corona electrode might generate a higher ionic wind than the needle point corona electrode.

Measurement and Analysis of Risk Voltages in a Grounding System (접지계에서 위험전압의 측정과 분석)

  • Jin, Chang-Hwan;Park, Dae-Won;Seo, Jae-Seok;Kil, Gyung-Suk;Gil, Hyeong-Jun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3099-3103
    • /
    • 2011
  • In measurement of risk voltages; the step and touch voltage, the distance between the current electrode and the ground electrode recedes up to several hundred meters as the scale of grounding system increases. This paper dealt with the measurement method of risk voltage in a restricted space. The risk voltage was analyzed depending on the distance and the direction of the current electrode from the ground electrode in a $10[m]{\times}10[m]$ mesh grounding system. The average value of risk voltages measured at a point 20 [m] away from the current electrode was deviated below 5 [%] from that measured at 100 [m] point. Consequently, the evaluation of risk voltage of a large-scale grounding system buried in a spatially restricted place is available if the current electrode is installed in symmetry to the ground electrode.

  • PDF

Effects of External Current Constraint on the Belousov-Zhabotinskii System Measured by a Pt Electrode

  • Wei, Guoying;Jin, Yongdong;Ge, Hongliang;Luo, Jiuli
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.4
    • /
    • pp.543-547
    • /
    • 2005
  • The Belousov-Zhabotinskii system measured by a Pt electrode is investigated under external electrode current constraint. A dynamical analysis of the electrode reaction phase has been made by means of a linearized stability criterion valid for three-variable system. It turns out that limit cycle oscillatory regime and dynamical behaviors of the electrode reaction phase have been degenerated under periodical electrode current.

Wire-tension Control System using Photo-interrupter Sensor and Micro-electrode Fabrication (광단속센서를 이용한 와이어장력 제어장치 및 마이크로전극 제조)

  • Kang, Myung Chang;Lee, Chang Hoon;Kim, Nam-Kyung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.3
    • /
    • pp.28-35
    • /
    • 2013
  • Micro electrical discharge machining (EDM) as a non-contact machining process is very effective for micromachining with a thin electrode because of its low machining reaction force. The micro-electrode machining device has the advantage of maintaining high precision through the whole processes and uses a feeding wire in the thin electrode tool manufacturing process. This study describes the design and evaluation of a micro-electrode machining device using optical photo-interrupter. The electrode was fabricated by reverse electrical discharge machining. The performance of designed system was evaluated to measure tension force according to feed speed of wire. This system for micro electrode fabrication proves the feasibility in the micro-EDM process of the micro holes and parts for industrial applications.

Implementation of Wireless ECG Measurement System Attaching in Chair for Ubiquitous Health Care Environment (유비쿼터스 헬스 케어 적용을 위한 의자 부착형 무선 심전도 측정 시스템 구현)

  • Ye, Soo-Young;Baik, Seong-Wan;Kim, Jee-Chul;Jeon, Gye-Rok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.8
    • /
    • pp.776-781
    • /
    • 2008
  • In this study, ubiquitous health care system attaching in chair to monitor ECG for health care was developed at the unconsciousness state. The system conveniently and simple measured ECG at non-consciousness. We measured the contact impedance to skin-electrode of metal mesh electrodes of the system. Contact impedance enable the electrode to use for ECG measurement. The results are that the impedance of the metal mesh electrodes according to sizes is low when the size is 4$cm^2$. As the result, when the size of the metal mesh electrode is 4$cm^2$, the electrode is fit for ECG measurement. We can acquired by positing the arm on the metal mesh electrode. The ECG signal was detected using a high-input-impedance bio-amplifier, and then passed filter circuitry. The measured signal transmitted to a PC through the bluetooth wireless communication and monitored. Data of the non-constrained ECG system attaching in chair is noise-data when comparing metal mesh electrode with the Ag/Agcl electrode but the data is significant to monitor ECG for check the body state.

A Consideration of Volume and Installation Method of Concrete-Embedded Foundation Earthed an Electrode (콘크리트에 매입된 기초접지극의 크기 및 설치방법에 관한 고찰)

  • Lee, Ju-Cheol;Lee, Young-Chul;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.7
    • /
    • pp.82-88
    • /
    • 2013
  • IEC standards do not require to limit the earthing resistance of the concrete-embedded foundation earthing electrode which is installed to a specific value. However, in Korea the value of $5{\Omega}$ and below applies to the earthing resistance for a domestic customer whose receiving voltage is 22.9kV. This paper calculates the minimum area and volume of the concrete-embedded foundation earthing electrode in order to obtain a specific value of the earthing resistance when the electrode of the building's lightning protection system and that of its power system are interconnected. It also suggested the most appropriate method of installing the foundation earthing electrode, taking the electric characteristics of concrete into account.