• Title/Summary/Keyword: Electrode Movement Control

Search Result 24, Processing Time 0.024 seconds

Oil Movement Control by Charge Density Control in the Electrowetting Display (하전입자의 분포에 따른 Electrowetting display의 오일의 움직임)

  • Kim, Tae-Hyun;Kim, Yeon-Sik;Ashanulhaq, Q.;Jeong, Eun;Hahn, Yoon-Bong;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.495-496
    • /
    • 2006
  • Electrowetting phenomenon is applied in the various field of technology. One of that is electrowetting display as a paper like electronic paper. Fast response and easy to express a color is goodness. In spite of that, the oil movement of the electrowetting display is irregular. So it doesn't look like uniform. Because of above reason, electrowetting display using patterned electrode is made and the characteristic of oil movement is observed. Electrode and polymer wall is patterned by photo-lithography. We analyze the oil movement according to the variation of size and the position of etched electrode area.

  • PDF

Oil Movement Control of Electrowetting Display with Patterned Electrode (전극 패턴을 이용한 Electrowetting display의 오일 제어)

  • Kim, Tae-Hyun;Kim, Yeon-Sik;Ashanulhaq, Q.;Jeong, Eun;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.04a
    • /
    • pp.47-48
    • /
    • 2006
  • Electrowetting phenomenon is applied in the various field of technology. One of that is electrowetting display as a paper like electronic paper. Fast response and easy to express a color is goodness. In spite of that, the oil movement of the electrowetting display is irregular. So it doesn't look like uniform. Because of the above reason, electrowetting display using patterned electrode is made and the characteristic of oil movement is observed. Electrode and polymer wall is patterned by photo-lithography. We analyze the oil movement according to the variation of size and the position of etched electrode area.

  • PDF

Welding Quality Improvement of Inverter Spot Welder by Electrode Movement Control (전극분리 제어에 의한 인버터 스폿용접기의 용접품질 향상)

  • 김재문;김종덕;원충연;최규하;김규식;목형수
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.276-284
    • /
    • 2000
  • 저항 스폿용접기에서 용접품질의 보증은 오래 계속 되어온 문제이었다. 본 논문에서는 용접품질과 전극분리와의 관계를 조사하였으며 전극분리가 하나의 제어변수로써 사용될 수 있음을 실험적으로 입증하였다. 피드백신호로서 전극분리를 이용한 퍼지제어에 기초를 둔 용접품질개선을 제시하였다. 저항 스폿용접기의 용접품질은 인장전단강도시험과 같은 파괴적인 검사에 의해 증명되었다. 시험결과는 퍼지 제어기를 이용한 전극분리 제어의 성능이 종래의 정전류 제어와 비교하여 훨씬 더 우수하였다.

  • PDF

Study on Characteristics of ECG Electrodes for Motion Artifact Reduction (동잡음 저감을 위한 심전도 전극 특성에 대한 연구)

  • Kang, Young-Hwan;Park, Jae-Soon;Cho, Bum-Ki;Choi, Sang-Dong;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.6
    • /
    • pp.366-371
    • /
    • 2017
  • In this paper, we introduce an electrocardiogram (ECG) system designed to solve problems caused by wetgels and motion artifacts in measuring active movement. The system is called a dry-contact ECG and was designed by considering impedance matching between skin and electrode as well as the frictional electricity between electrode and clothes. In order to create the system, we measured impedance on the skin-electrode interface, and the result was applied to the electronic circuit scheme. Moreover, we added an electrode on the back of the measurement electrode to make a flow path to ground the electrical noise. The final ECG circuit and novel electrode were used to detect real human cardiac signals from a subject who was tested while standing still and walking. The signals obtained from the two activities were nicely shaped, without any motion artifact noise. We took electrode size into account in this study because the impedance depended on the area of the electrode. An electrode of 50 mm diameter showed the best curve for the ECG signal without any electrical noise.

Simplified Ground-type Single-plate Electrowetting Device for Droplet Transport

  • Chang, Jong-Hyeon;Kim, Dong-Sik;Pak, James Jung-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.402-407
    • /
    • 2011
  • The current paper describes a simpler ground-type, single-plate electrowetting configuration for droplet transport in digital microfluidics without performance degradation. The simplified fabrication process is achieved with two photolithography steps. The first step simultaneously patterns both a control electrode array and a reference electrode on a substrate. The second step patterns a dielectric layer at the top to expose the reference electrode for grounding the liquid droplet. In the experiment, a $5{\mu}m$ thick photo-imageable polyimide, with a 3.3 dielectric constant, is used as the dielectric layer. A 10 nm Teflon-AF is coated to obtain a hydrophobic surface with a high water advancing angle of $116^{\circ}$ and a small contact angle hysteresis of $5^{\circ}$. The droplet movement of 1 mM methylene blue on this simplified device is successfully demonstrated at control voltages above the required 45 V to overcome the contact angle hysteresis.

A Study on an Ion Wind Created by a Wire Electrode and Parallel Plates Assembly (와이어 전극과 평행판에서 발생되는 이온풍 특성 연구)

  • 안영철;황필재;이재근
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.318-323
    • /
    • 2004
  • When a strong electric field is applied between a sharply curved electrode and a blunt surface, the corona may result in a gas movement in the electrode gap which is directed toward the blunt surface. That is called the corona wind. It enhances heat and mass transfer between the surface and the surrounding gas. Moreover such enhancement causes no noise or vibration, which can be applied in complex, isolated geometries, and allows simple control of surface temperatures. This paper examines the relationship between the corona wind and the relative humidity. The facility consists of high voltage power supply thin tungsten wire, plate electrode, multimeter, microammeter and flow meter. Gas velocity is a linear function of voltage, relative humidity and is proportional to the square root of the current. The maximum velocities for the positive and negative corona discharge are 1.9 m/s (2.74 CMM/m), 1.5 m/s(2.15 CMM/m), respectively.

Study of Machine Learning based on EEG for the Control of Drone Flight (뇌파기반 드론제어를 위한 기계학습에 관한 연구)

  • Hong, Yejin;Cho, Seongmin;Cha, Dowan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.249-251
    • /
    • 2022
  • In this paper, we present machine learning to control drone flight using EEG signals. We defined takeoff, forward, backward, left movement and right movement as control targets and measured EEG signals from the frontal lobe for controlling using Fp1. Fp2 Fp2 two-channel dry electrode (NeuroNicle FX2) measuring at 250Hz sampling rate. And the collected data were filtered at 6~20Hz cutoff frequency. We measured the motion image of the action associated with each control target open for 5.19 seconds. Using Matlab's classification learner for the measured EEG signal, the triple layer neural network, logistic regression kernel, nonlinear polynomial Support Vector Machine(SVM) learning was performed, logistic regression kernel was confirmed as the highest accuracy for takeoff and forward, backward, left movement and right movement of the drone in learning by class True Positive Rate(TPR).

  • PDF

Development of Micro-EDM Machine for Microshaft and Microhole Machining (미소 축.구멍 가공용 미세 방전 가공기의 개발)

  • 김규만;김보현;주종남
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.1075-1079
    • /
    • 1995
  • It is difficult to machine microparts, such as microshaft and microholes, by conventional machining. Such micropart can be easily machined by EDM because it's machining force is very low. In micro-EDM, the precise electrode movement and discharge energy control are important. Therefore, high precision motion stage and EDM device with high performance is necessary. In this research, a new EDM machine was developed and microshaft and microhole, with various shape and size, was machined.

  • PDF

Surface EMG Network Analysis and Robotic Arm Control Implementation

  • Ryu, Kwang-Ryol
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.6
    • /
    • pp.743-746
    • /
    • 2011
  • An implementation for surface EMG network analysis and vertical control system of robotic arm is presented in this paper. The transmembranes are simulated by equivalent circuit and cable equation for propagation to be converted to circuit networks. The implementation is realized to be derived from the detecting EMG signal from 3 electrodes, and EMG transmembrane signals of human arm muscles are detected by several surface electrodes, high performance amplifier and filtering, converting analog to digital data and driving a servomotor for spontaneous robotic arm. The system is experimented by monitoring multiple steps vertical control angles corresponding to biceps muscle movement. The experimental results are that the vertical moving control level is measured to around 2 degrees and mean error ranges are lower 5%.

Electrical Stimulation System Design for Pharyngeal Dysfunction of Stroke Patients (뇌졸중 환자의 인두기능 회복을 위한 전기자극기 설계)

  • 김성민;배하석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1232-1235
    • /
    • 2004
  • The purpose of this study is to design electrical stimulation system for pharyngeal dysfunction(dysphagia) in stroke patients. Pharyngeal muscle group activity is important, because contracting muscles provide the driving force at the initiation of the swallow and generate the pressure gradients necessary for bolus movement into the esophagus. Although we have many treatment methods for dysphagia, electrical stimulation system will be useful for stroke patients having dysphagia. Electrical stimulation can be divided into the body stimulation and electrodes. The body stimulation is divided again into frequency counter, time control and current measurement part. These parts are to control the current intensity, frequency and stimulating time. And they can be variable according to the patient's clinical assessment. The electrode plays a role to deliver the current from the system to the muscle. Also the position of the electrode can be variable according to the treatment method. We performed the clinical experiment with the stroke patient who has swallowing disorder. The videofluoroscopy was used for the observation. From the result of clinical experiment based on electrical stimulation, we expected that the dysfunction(in pharynx) level of the patient can be improved. However we could not have enough effectiveness of the treatment because of the number of patients, patient's adaptation and treatment period. We will design the optimized electrical stimulation system based on enough clinical experiment in the future.

  • PDF