• 제목/요약/키워드: Electrode Distance

검색결과 409건 처리시간 0.027초

NaCl 전해질 농도 변화에 따른 다공질 탄소전극의 전기적 특성 (Electrical Characteristics of Porous Carbon Electrode According to NaCl Electrolyte Concentration)

  • 김용혁
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.814-819
    • /
    • 2010
  • Porous carbon electrodes with wooden materials are manufactured by molding carbonized wood powder. Electrical properties of the interface for electrolyte and porous carbon electrode are investigated from viewpoint of NaCl electrolyte concentration, capacitance and complex impedance. Density of porous carbon materials is 0.47~0.61 g/$cm^3$. NaCl electrolytic absorptance of the porous carbon materials is 5~30%. As the electrolyte concentration increased, capacitance is increased and electric resistance is decrease with electric double layer effect of the interface. The electric current of the porous carbon electrode compared in the copper and the high density carbon electrode was improved on a large scale, due to a increase in surface area. The circuit current increased as the distance between of the porous carbon electrode and the zinc electrode decreased, due to increase in electric field. Experimental results indicated that the current properties of galvanic cell could be improved by using porous carbon electrode.

마그네슘 금속연료전지의 출력특성에 관한 연구 (A Study of Power Output Characteristics for the Magnesium Metal Fuel Cell)

  • 김용혁
    • 전기학회논문지P
    • /
    • 제63권3호
    • /
    • pp.212-217
    • /
    • 2014
  • The electric power output characteristics of magnesium fuel cell were investigated with regard to internal resistance. A equivalent circuit with the series-connected three internal resistance was introduced to analyze of the response to change of power. The power output analysis was employed in order to investigate the effect of internal resistances for the electrolyte concentration, air electrode area, Mg electrode area and distance between the electrodes. It was confirmed that internal resistance is generated by the electrolyte, air electrode and metal electrode, then those Internal resistances had a significant effect on the power output decrease. The power output was a maximum when the load resistance maches the internal resistance of the magnesium fuel cell. The fuel efficiency was only 50% at maximum power output. Higher fuel efficiency was achieved when the load resistance is greater than the internal resistance.

선 대 평판형 플라즈마 반응기 제작을 위한 전위 및 전계 해석 (Simulation of Electric Potential and Electric Field for Wire-Plate Type Plasma Reactor Manufacture)

  • 이동훈
    • 전기학회논문지P
    • /
    • 제52권4호
    • /
    • pp.167-171
    • /
    • 2003
  • Due to advancement of industrialization, the flue gas from the combustion of industrial factories and various means of transportation have polluted air. Therefore, it is necessary to develop new techniques of air purification. In order to produce a more effective reactor, simulation were conducted using the Flux-II D program. The condition of the simulation were as follows: The height of the plate electrode was 0 mm or 2 mm higher than that of the wire electrode. The distance between the electrodes was 12 mm, and the diameter of the wire electrode was 0.5 mm or 1.0 mm. The results of the electric potential and electric field simulations show that pollutants will be more effectively removed due to the dielectric strength between wire electrode and plate electrode which was strong, and wire electrodes which were concentrated in a high electric field.

전극형상에 의한 초고압 CV케이블 절연체의 부분방전 특성 (Partial Discharge Characteristics of Ultra-High Voltage CV Cable Insulators by Electrode Shape)

  • 김규식;김병현;정현기;차광석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.712-717
    • /
    • 2005
  • In this thesis, it is investigated that the effect of the cross linked polyethylene(XLPE) insulator do to breakdown phenomenon by the insertion of the needle and bar electrode into XLPE which is used of electric power cable for the ultra-high voltage. The result of the partial discharge properties in the specimen showed that in case of the insertion of needle or bar electrode into XLPE, the effect of the inner discharge become large when the air void is bigger then the clearance of the electrode of the specimen. The closer the distance between the insulator and needle electrode, it takes less time to the insulation breakdown.

  • PDF

보조전극의 위치에 따른 매설지선의 접지임피던스 측정정확도의 평가 (Evaluation of Measurement Accuracy of Ground Impedances in Counterpoise according to Location of Auxiliary Electrodes)

  • 이복희;최영철;최종혁;김동규;이규선;양순만;김태기
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.352-355
    • /
    • 2009
  • The ground resistance has been used as a method of estimating the capability of counterpoise. When transient currents blow through a ground electrode, it is reasonable to evaluate the performance of ground electrode system as a ground impedance instead of ground resistance. However, the measurement method of ground impedance for counterpoise is not clearly presented. This paper describes the measurement method of ground impedance considering the earth mutual resistances and AC mutual coupling. When we measure the ground impedance, the error due to earth mutual resistances depends on the distance between the auxiliary electrodes and the electrode under test. The measurement accuracy of high frequency ground impedance is mainly influenced by the location of the current electrode and the potential electrode.

  • PDF

Simulation of Low Temperature Plasmas for an Ultra Violet Light Source using Coplanar Micro Dielectric Barrier Discharges

  • Bae, Hyowon;Lee, Ho-Jun;Lee, Hae June
    • Applied Science and Convergence Technology
    • /
    • 제25권6호
    • /
    • pp.138-144
    • /
    • 2016
  • The discharge characteristics of pulse-driven coplanar micro barrier discharges for an ultraviolet (UV) light source using Ne-Xe mixture have been investigated using a two-dimensional fluid simulation at near-atmospheric pressure. The densities of electrons, the radiative excited states, the metastable excited states, and the power loss are investigated with the variations of gas pressure and the gap distance. With a fixed gap distance, the number of the radiative states $Xe^*(^3P_1)$ increases with the increasing driving voltage, but this number shows weak dependency on the gas when that pressure is over 400 Torr. However, the number of the radiative states increases with the increase of the gap distance at a fixed voltage, while the power loss decreases. Therefore, a long gap discharge has higher efficiency for UV generation than does a short gap discharge. A slight change in the electrode tilt angle enhances the number of radiative species 2 or 3 times with the same operation conditions. Therefore, the intensity and efficiency of the UV light source can be controlled independently by changing the gap distance and the electrode structure.

탄소소재 산업부산물을 사용한 시멘트 모르타르의 전기·물리적 특성 연구 (A Study on the Electrical and Physical Properties of Cement Mortar used Carbon Material Industrial by-product)

  • 조정훈;김남일;이영준;서성관;추용식
    • 자원리싸이클링
    • /
    • 제30권6호
    • /
    • pp.19-27
    • /
    • 2021
  • 본 연구에서는 탄소소재 산업부산물을 사용한 전기전도성 발열 모르타르를 제조 및 분석하였다. 이때 탄소소재 및 혼합수 함량을 제어하였으며, 전압 인가 시 전극간 거리는 0.42 m 및 0.88 m로 고정하였다. 본 연구에서 사용한 탄소소재 산업부산물은 판상형 구조의 흑연이었다. 탄소소재는 입도에 따라 미분말 및 골재 대체용으로 사용하였으며, 각각의 평균 입도는 18 ㎛ 및 546 ㎛, 전기전도도는 62.3 S/m 및 32.5 S/m로 측정되었다. 동일한 모르타르 플로우 값 유지를 위해 탄소소재 혼합량 증가에 따라 혼합수 함량을 증가시켰으며, 이에 따라 기공률은 상승하였다. 모르타르(6주차)의 전극거리 0.42 m에서 전압-전류값은 342 V-1.48 A(S20) 및 349 V-1.44 A(S30)이었으며, 0.88 m에서는 513 V-0.98 A(S20) 및 500 V-1.01 A(S30)으로 확인되었다. 또한 발열 특성은 산업부산물인 탄소소재 함량이 증가하고, 전극간 거리가 감소할수록 우수하였다.

Electro-Fenton 반응을 위한 불용성 전극의 과산화수소 생성과 Rhodamine B의 제거 (Hydrogen Peroxide Generation of DSA for Electro-Fenton Reaction and Removal of Rhodamine B)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제34권2호
    • /
    • pp.175-182
    • /
    • 2008
  • This study investigates the optimal conditions for electrogenerated hydrogen peroxide production and the application of the electro-Fenton process using DSA electrodes. The influences of parameters for the hydrogen peroxide generation such as electrode materials, electrolyte concentration, current, pH, air flow rate and electrode distance were investigated using a laboratory scale batch reactor. The relative performance for hydrogen peroxide generation of each of the six electrodes is : Ru-Sn-Ti > Ru-Sn-Sb > Ru > Ir > Pt > Sn-Sb. Optimum NaCl dosage, current and air flow rate were 2.0 g/l, 12.5 A and 2 l/min, respectively. When the pH is low, hydrogen peroxide concentration was high. Electrode distance dos not effect to a hydrogen peroxide generation. A complete color removal was obtained for RhB (200 mg/l) at the 8 min mark of the electro-Fenton process under optimum operation conditions of $Fe^{2+}$ 0.105 g/l and 5.0 A. The electro-Fenton process increased initial reaction and decreased final reaction time. However the effect was not high.

Electrode Characteristics of Non-contact Electrocardiographic Measurement

  • Mathias, Dakurah Naangmenkpeong;Kim, Sung-Il;Park, Jae-Soon;Joung, Yeun-Ho;Choi, Won Seok
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권1호
    • /
    • pp.42-45
    • /
    • 2015
  • The ability to take electrocardiographic measurements while performing our daily activities has become the people-choice for modern age vital sign sensing. Currently, wet and dry ECG electrodes are known to pose threats like inflammations, allergic reactions, and metal poisoning due to their direct skin interaction. Therefore, the main goal in this work is to implement a very small ECG sensor system with a capacitive coupling, which is able to detect electrical signals of heart at a distance without the conductive gel. The aim of this paper is to design, implement, and characterize the contactless ECG electrodes. Under a careful consideration of factors that affect a capacitive electrode functional integrity, several different sizes of ECG electrodes were designed and tested with a pilot ECG device. A very small cotton-insulated copper tape electrode ($2.324cm^2$) was finally attained that could detect and measure bioelectric signal at about 500 um of distance from the subject's chest.

비전도성 액체의 전기수력학적 분무에 관한 실험적 연구 (An Experimental Study on Electrohydrodynamic Atomization of Non-Conducting Liquid)

  • 이기준;박종승;이상용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1322-1327
    • /
    • 2004
  • In the present work, a series of experiments have been performed on electro-hydrodynamic atomization of non-conducting liquid using a charge injection type nozzle. Effects of liquid flow rate, input voltage, and distance between the needle and the ground electrode (nozzle-embedded metal plate) have been examined. For fixed electrode distances, total and spray currents increase with increase of liquid flow rate and input voltage. When the distance between the needle and the ground electrode becomes closer, total, leakage and spray current increase, but the onset voltage for dielectric breakdown decreases. When the electric field strength of the liquid jet exceeds that for the air breakdown, a portion of the electric charges in the liquid jet is dissipated into the ambient air, and the charge density shows a limiting value. Atomization quality can be improved by increasing the flow rate because the higher charge density is achieved with the larger liquid velocity in addition to the enhanced aerodynamic effect.

  • PDF