• Title/Summary/Keyword: Electrode Distance

Search Result 410, Processing Time 0.023 seconds

Radiofrequency C2 Ganglionotomy in Atlantoaxial Subluxation: Short Term Follow up (환축추 전방아탈구 환자에서 제 2 경추신경절 열응고술 후의 예후에 대한 단기적 추적관찰)

  • Shim, Jae-Hang;Shim, Jae-Chul
    • The Korean Journal of Pain
    • /
    • v.14 no.2
    • /
    • pp.193-198
    • /
    • 2001
  • Background: Anterior atlantoaxial subluxation (AAS) is a frequent phenomenon in rheumatoid arthritis (RA). AAS compresses the C2 ganglion or nerve and is a cause of posterior neck pain or occipital headache. Methods: We selected RA patients that had developed posterior neck pain or occipital headache caused by AAS. AAS was diagnosed by an increase of ADI (atlantodental interval). A distance of 3 mm or more was considered significant. Patients with vertical subluxation or symptoms suggestive of myelopathy were excluded. Before C2 RF ganglionotomy, we proceeded with a C2 ganglion block or greater occipital nerve block used by local anesthetics. For C2 RF ganglionotomy, the patient was placed in the supine position on a fluoroscopic table. A 100 mm, 4 mm active tip electrode was chosen. Following sensory stimulation at 0.2 to 0.6 V, the lesion was performed at a temperature of $60^{\circ}C$ to $65^{\circ}C$ for 60 sec. We followed up the patient after 6 months later. Results: All cases were female and the average duration of RA was 8.5 years. The duration of posterior neck pain or occipital headache was 1-8 months. The average ADI was 4.2 mm and the McGregor index was 3.3 mm on the average. In all cases, the score on the 4 point Likert scale was 4 (pain free) during the follow-up period. Conclusions: We found that the occipital headache or posterior neck pain caused by AAS in rheumatoid arthritis patients was alleviated over a short term follow up. C2 RF ganglionotomy is suggested as an effective palliative treatment for AAS in RA patients.

  • PDF

Consideration of Methods Evaluating the Growing Process of Stress Corrosion Cracking of the Sensitized 18-8 Austenitic Stainless Steel in High Temperature Water Based on Electric Circuit Theory: The Effects of Stress Factors

  • Tsukaue, Yasoji
    • Corrosion Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.103-111
    • /
    • 2007
  • The effect of stress factors on the growing process of stress corrosion cracking (SCC) of the sensitized 18-8 stainless steel in high temperature water was investigated using equations of crack growth rate derived from applying electric circuits to SCC corrosion paths. Three kinds of cross sections have to be considered when electric circuit is constructed using total current. The first is ion flow passage area, $S_{sol}$, of solution in crack, the second is total dissolving surface area, $S_{dis}$, of metal on electrode of crack tip and the third is dissolving cross section, $S_{met}$, of metal on grain boundary or in base metal or in welding metal. Stress may affect each area. $S_{sol}$ may depend on applied stress, $\sigma_{\infty}$, related with crack depth. $S_{dis}$ is expressed using a factor of $\varepsilon(K)$ and may depend on stress intensity factor, K only. SCC crack growth rate is ordinarily estimated using a variable of K only as stress factor. However it may be expected that SCC crack growth rate depends on both applied stress $\sigma_{\infty}$ and K or both crack depth and K from this consideration.$\varepsilon(K)$ is expressed as ${\varepsilon}(K)=h_2{\cdot}K^2+h_3{\cdot}K^3$ when $h_{2}$ and $h_{3}$ are coefficients. Also, relationships between SCC crack growth rate, da/dt and K were simulated and compared with the literature data of JBWR-VIP-04, NRC NUREG-0313 Rev.2 and SKIFS Draft. It was pointed out in CT test that the difference of distance between a point of application of force and the end of starter notch (starting point of fatigue crack) may be important to estimate SCC crack growth rate. An anode dissolution current density was quantitatively evaluated using a derived equation.

Fabrication of Field Emission Device Using Carbon Nanotubes Synthesized by Thermal Chemical Vapor Deposition (열 화학 기상 증착법을 이용한 탄소 나노 튜브 전계 방출 소자의 제조)

  • Yu, W.J.;Cho, Y.S.;Choi, G.S.;Kim, D.J.;Kim, H.Y.;Yoon, S.K.
    • Korean Journal of Materials Research
    • /
    • v.13 no.5
    • /
    • pp.333-337
    • /
    • 2003
  • We report a new fabrication process for carbon nanotube field emitters with high performance. The key of the fabrication process is trim-and-leveling the carbon nanotubes grown in trench structures by employing a planarization process, which leads to a uniform distance from the carbon nanotube tip to the electrode. In order to enable this processing, spin-on-glass liquid is applied over the CNTs grown in trench to have them stubborn adhesion among themselves as well as to the substrate. Thus fabricated emitters reveal an extremely stable emission and aging characteristics with a large current density of 40 ㎃/$\textrm{cm}^2$ at 4.5 V/$\mu\textrm{m}$. The field enhancement factor calculated from the F-N plot is $1.83${\times}$10^{5}$ $cm^{-1}$ , which is a very high value and indicates a superior quality of the emitter originating from the nature of open-tip and high stability of the carbon nanotubes obtained new process.

A Transflective Liquid Crystal Display Driven by the Fringe Field Using a Liquid Crystal with a Negative Dielectric Anisotropy

  • Kim, Jin-Ho;Her, Jung-Hwa;Lim, Young-Jin;Kumar, Pankaj;Lee, Seung-Hee;Park, Kyoung-Ho;Lee, Joun-Ho;Kim, Byeong-Koo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.3
    • /
    • pp.134-137
    • /
    • 2010
  • We have proposed a transflective liquid crystal display (LCD) driven by the fringe field using a liquid crystal (LC) with a negative dielectric anisotropy. The device used different twist angles of the liquid crystals (LC) in the transmissive (T) and the reflective (R) regions when voltage is applied. With the optimization of the pixel electrode width and the distance between them, the LC directors in the R- and T-regions can be rotated by about $22.5^{\circ}$ and $45^{\circ}$ on an average, respectively. As a result, a high image quality transflective LCD with a single gap, a single gamma, and a wide viewing angle characteristics in both the R- and T- regions can be realized.

Dielectric Properties of Continuous Composition Spreaded $BaTiO_3-SrTiO_3$ Thin Films Prepared by Off-Axis RF Magnetron Sputtering System

  • Kim, Yoon-Hoe;Jung, Keun;Yoon, Seok-Jin;Park, Kyung-Bong;Choi, Ji-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.326-326
    • /
    • 2010
  • The dielectric properties of continuous composition spreaded (CCS) $BaTiO_3-SrTiO_3$ (BST) thin filmsgrown at room temperature and annealed at different temperature ($350^{\circ}C$ and $550^{\circ}C$) were investigated. Moreover, electrical properties (leakage current and breakdown voltage) of CCS BST thin films were also investigated. The aluminum top-electrode, sized by $200{\times}200\;{\mu}m2$ and apart from each other by $300\;{\mu}m$, were deposited on the CCS BST thin films by the DC sputtering system. The dielectric properties of the CCS BST thin films were significantly influenced depending on the distance from $BaTiO_3$ and $SrTiO_3$ targets which was attributed to the $BaTiO_3-SrTiO_3$ composition ratio. The maps of dielectric constants and loss tangents were plotted via $1500\;{\mu}m$ - step measuring. The specific points showing the dielectric constant (k: ~300) and loss tangent (tand: ~0.008) at 1 MHz were found.

  • PDF

Study on the Distribution of Fluorides in Plants and the Estimation of Ambient Concentration of Hydrogen Fluoride Around the Area of the Accidental Release of Hydrogen Fluoride in Gumi (구미 불산 누출사고 지점 주변 식물의 불소화합물 농도 분포 및 공기 중 불화수소 농도 추정에 관한 연구)

  • Gu, Seulgi;Choi, Inja;Kim, Won;Sun, Oknam;Kim, Shinbum;Lee, Yungeun
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.4
    • /
    • pp.346-353
    • /
    • 2013
  • Objectives: The goal of this study is to identify the distribution of the foliar fluorine content of vegetation surrounding the area where hydrofluoric acid was accidently released in Gumi, Gyeongsangbuk-do on September 27, 2012. In addition, it also aims to estimate the concentration of hydrogen fluoride in the air on the day of the accident. Methods: Samples of plant leaves were collected on October 7, 2012 within 1 km from the site where the accident occurred. These samples were analyzed for soluble fluorine ion with an ion selective electrode. The ambient concentration of hydrogen fluoride was calculated using the fluoride content in the plant via the dose-rate equation (${\Delta}F$=KCT). Results: The arithmetic and geometric means of the concentrations were 2158.2 and 1183.7mg F $kg^{-1}$ for leaves and, 2.4 and 1.1 ppm HF for the air, respectively. The highest concentration of hydrogen fluoride in the air was 14.7 ppm, which is higher than the maximum concentration reported by the government (1 ppm) and the exposure limit (ceiling, 3 ppm). The concentrations of both fluorine and hydrogen fluoride decreased with increasing distance from the accident site and showed a significant decrease outside of a 500m radius from the site (p <0.05). Conclusions: The area around the accident site was highly polluted with hydrogen fluoride according to the results of this study. Considering the persistency of hydrogen fluoride in the environment, long-term monitoring and environmental impact assessment should be pursued.

An Experimental Study on Installation Effects of Pipe Elbow on the Electromagnetic Flowmeter Characteristics (Turbulent Flow) (곡관의 하류에 설치된 전자기유량계의 유량신호 특성에 관한 실험적 연구(난류 유동))

  • Lim, Ki-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1613-1621
    • /
    • 2002
  • An electromagnetic flowmeter(EMF) essentially averages the velocity distribution over the pipe cross- sectional area, and the measured value is dependent on the velocity profiles. In this study, installation effects of 90$^{\circ}$long elbow(KS B 1522, ISO 3419) on the EMF characteristics was investigated. A commercial EMF was adopted and the distribution of magnetic field in the electrodes cross section was measured. In the experiment, the national flow standard system, of which measurement uncertainty was evaluated in accordance with ISO 17025 recommendation, was used fur characterization of EMF. The leading line has 150D long straight pipe to established a fully developed flow before entering into the elbow and the elbow was installed downstream of it. then the flowmeter was tested within 50 D from the elbow. The installation effects of the flowmeter were investigated by varying the mean velocity(Reynolds No.)in pipe section, the locations and the direction of electrodes plane.($\phi$) From the experimental results, we find the optimal conditions to get most accurate measurements. Generally, the deviations from the calibration value were less than 0.5 % in farther than 10D distance from the elbow and the direction of electrode plane. $\phi$ = 90$^{\circ}$yielded the smallest measurement deviation. These characteristics were shown consistently in turbulent region regardless of the mean Reynolds number.

Electrical Resistivity Survey at the Ground with Micro-subsidence by Excessive Pumping of Groundwater (지하수 과잉양수에 따른 미세 지반변형 지역에서의 전기비저항 탐사)

  • Song Sung-Ho;Lee Kyu-Sang;Yong Hwan-Ho;Kim Jin-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.3
    • /
    • pp.197-206
    • /
    • 2004
  • Because the minute displacement of ground accompanied by excessive pumping of groundwater at specified site is mainly generated from ill-balancing of water budget within groundwater basin, It is necessary to monitor the variation of micro-subsidence for a long time at representative points. We made up the conceptual model using two-dimensional electrical resistivity survey and three-dimensional soil profile consisted of loam and sand. In verifying the reliability of this conceptual model using numerical modeling for ground settlement and groundwater flowing, two-dimensional electrical resistivity survey with short distance of electrode following soil sampling with hand auger would be useful for interpreting hydrogeological structure related to the minute displacement of ground consisted of loam and sand.

Electrical Resistivity Survey in the Eon-Yang Fault Area, Southeastern Korean Peninsula (경상분지(慶尙盆地) 언양단층(彦陽斷層) 지역(地域)에 대(對)한 전기비저항(電氣比抵抗) 탐사연구(探査硏究))

  • Kim, In-Soo;Kim, Jong-Yeol
    • Economic and Environmental Geology
    • /
    • v.16 no.1
    • /
    • pp.11-18
    • /
    • 1983
  • Gyeongsang Basin in the southeastern part of the Korean peninsular is characterized by many fault systems. To decipher the geotectonical evolution of the Korean peninsular and marginal basins in her adjacent areas it is prerequisite to understand the spatial distribution pattern and mutual relationships of these fault systems. Because of difficulties in finding any criterion to recognize the faults in field, their extension and mutual relationships in ages are not very clear yet. As an attempt to find geophysical criteria to recognize the fault, geoelectrical resistivity survey was carried out in this study. With the Wenner configuration four resistivity soundings and twenty seven resistivity profilings were done. The electrode distance used was up to 50m. From the results of the resistivity soundings and boring data of earlier groundwater investigations the depth of alluvial and weathered zone was established to be at most 20m in the study area. In the resistivity profiling low resistivity anomaly zones are detected on every traverse, which are interpreted as caused by fractures, fault clays and mylonites in the fault zone. The width of the fault zone amounts to 0.3-1km. By correlating and connecting the negative anomaly zones from traverse to traverse one can determine the trend of th of the faultzone and therefore that of fault itself. The recognized fault trend in this way was $N15^{\circ}-20^{\circ}E$ and this coincides with the direction of the inferred fault line from earlier geological surface mapping. With the help of this characteristical negative anomaly the existance of another $N80^{\circ}W$ trending fault was estabished. This study has shown that geoelectrical resistivity survey can be applied successfully to the problem of tracing fault line insofar as a fault zone has been developed along fault line.

  • PDF

Preparation of ZnO Thin Film by Electrophoretic Deposition(EPD)

  • Jun, Byung-Sei
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.1
    • /
    • pp.78-83
    • /
    • 2012
  • The electrophoretic deposition(EPD) of ZnO nano-sized colloids is investigated by changing the colloid number concentration, applied force, and deposition time. The change of the colloid size in a suspension was examined by the different colloid number concentrations (N = $3.98{\times}10^{15}$, N = $3.98{\times}10^{14}$, and N = $3.98{\times}10^{13}$) with an increase of the deposition time and applied forces. Deposition behavior was investigated by changing the applied fields (from DC 5 V to 50 V) and the deposition time (5 min to 25 min). The surface microstructures of the as-deposited films were investigated by SEM. The dried films were sintered from $850^{\circ}C$ to $1,050^{\circ}C$ for 2 h and then the microstructures were also explored by SEM. The agglomeration rate was enhanced by increasing the colloid number concentration of colloids. Colloid number concentration in a suspension must be rapidly decreased at higher values of the electric field. ZnO nano-sized colloids had the highest zeta potential value of over -28 mV in methanol. A homogeneous microstructure was obtained at colloid number concentration of N = $3.98{\times}10^{13}$, applied DC field of 5 V/cm and 15 min of deposition time at an electrode distance of 1.5 cm. Under these conditions, the deposited films were sintered at $850^{\circ}C$ and $1,050^{\circ}C$ for 2 h. The results show a typical pore-free surface morphology of a uniform thickness of 400 nm under these experimental conditions.