• Title/Summary/Keyword: Electrochemical process

Search Result 1,281, Processing Time 0.025 seconds

Conversion of a Constant Phase Element to an Equivalent Capacitor

  • Chang, Byoung-Yong
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.318-321
    • /
    • 2020
  • Here I present a formula which converts a constant phase element (CPE) to its equivalent capacitor. Electrochemical impedance spectroscopy is capable of resolving a complex electrochemical processes into its faradaic and non-faradaic elements, and the non-faradaic process is frequently described as a CPE in place of a capacitor due to the non-ideality. Being described as a capacitor, the non-faradaic element provides information by its capacitance, but a CPE cannot provide a physical meaning. In order to solve the problem, the CPE has been dealt with as an equivalent capacitor of which the capacitance provides practical information. Succeeding the two methods previously suggested, a new conversion method is suggested in this report. While the previous ones manipulate only the CPE, the new method takes both the CPE and its related resistor into account for conversion. By comparing the results obtained by the three methods, we learn that the results are nearly the same within tolerable ranges, and conclude that any of the method choices is acceptable depending on the conditions of the system of interest.

A study of electrochemical micromachining with voltage pulses (미세 펄스 전압을 이용한 마이크로 전해가공에 관한 연구)

  • 조창래;백승엽;이은상
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.356-361
    • /
    • 2003
  • Electrochemical micromachining which is not normally considered as a precision process is presented in this paper. The application of voltage Pulses between a tool electrode and a workpiece in an electrochemical environment allows the three-dimensional machining of conducting materials with micrometer precision. In this paper tool-electrodes($5\mu\textrm{m}$ in diameter, 1mm in length) are developed by electrochemical micromaching and micro holes are manufactured using this tool-electrodes we developed already. Micro holes are achieved the accuracy below $50\mu\textrm{m}$ in diameter using ultrashort voltage pulses(0.1-5$\mu\textrm{s}$).

  • PDF

Micro Electrochemical Machining of Stainless Steel Using Citric Acid (구연산을 이용한 스테인레스 스틸의 미세 전해가공)

  • Ryu, Shi-Hyoung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.3
    • /
    • pp.134-140
    • /
    • 2008
  • Micro electrochemical machining (ECM) is conducted on stainless steel 304 using non-toxic electrolyte of citric acid. Electrochemical dissolution region is minimized by applying a few hundred second duration pulses between the tungsten SPM tip and the work material. ECM characteristics according to citric acid concentration, feeding velocity and electric conditions such as pulse amplitude, pulse frequency, and offset voltage are investigated through a series of experiments. Micro holes of $60{\mu}m$ in diameter with the depth of $50{\mu}m$ and $90{\mu}m$ in diameter with the depth of $100{\mu}m$ are perforated. Square and circular micro cavities are also manufactured by electrochemical milling. This research can contribute to the development of safe and environmentally friendly micro ECM process.

Electrochemical Sensor for Detecting Underwater Biofilm Using Cyclicvoltammetry (순환전압전류법을 이용한 수중 생물막 측정 전기화학센서)

  • Hwang, Byeong-Jun;Lee, Sung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.374-378
    • /
    • 2012
  • Biofouling causes many problem in industrial processes, medical health industries, water utilities and our daily life. So detecting formation of biofilm on the surface of medical appliance, water pipe and industrial utility is highly important to prevent the problem caused by biofouling. In this study, we suggest an electrochemical sensor for detecting biofilm. We fabricated the electrochemical sensor in MEMS process and cultivated two different kinds of Pseudomonas aeruginosa RpoN type and Wild type on the surface of electrochemical sensor. Each group of Pseudomonas aeruginosa was cultivated according to the hours of 2, 4, 6, 8, 12 and 24. Then we investigated changes in degree of biofilm cultivation using cyclic voltammetry. As a result, it was observed that peak of the cyclic voltammetry curve is increased according as the biofilm growth on the surface of electrochemical sensor. Also we can discern between Pseudomonas aeruginosa RpoN type and Wild type.

Electrochemical Machining Using a Disk Electrode for Micro Internal Features (미세 내부 형상 가공을 위한 디스크 전극 이용 전해 가공)

  • Jo, Chan-Hee;Kim, Bo-Hyun;Chu, Chong-Nam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.7
    • /
    • pp.139-144
    • /
    • 2008
  • Micro electrochemical machining was investigated to machine micro internal features. This method uses a micro disk tool electrode and can easily machine micro features inside of a micro hole, which are very difficult to make by the conventional processes. In order to limit the machining area and localize the electrochemical dissolution, ultra short pulses were used as power source and a micro disk electrode with insulating layer on its surface was used as a tool electrode. By electrochemical process, internal features, such as groove array, were fabricated on the stainless steel plate.

Monitoring the Degradation Process of Inconel 600 and its Aluminide Coatings under Molten Sulfate Film with Thermal Cycles by Electrochemical Measurements

  • Take, S.;Yoshinaga, S.;Yanagita, M.;Itoi, Y.
    • Corrosion Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.259-264
    • /
    • 2016
  • With a specially designed electrochemical cell, the changes in impedance behavior for Inconel 600 and aluminide diffusion coatings under molten sulfate film with thermal cycles (from $800^{\circ}C$ to $350^{\circ}C$) were monitored with electrochemical impedance measurements. It was found that corrosion resistance for both materials increased with lower temperatures. At the same time, the state of molten salt was also monitored successfully by measuring the changes in impedance at high frequency, which generally represents the resistance of molten salt itself. After two thermal cycles, both Inconel 600 and aluminide diffusion coatings showed excellent corrosion resistance. The results from SEM observation and EDS analysis correlated well with the results obtained by electrochemical impedance measurements. It is concluded that electrochemical impedance is very useful for monitoring the corrosion resistance of materials under molten salt film conditions even with thermal cycles.

Optical Interferometry as Electrochemical Emission Spectroscopy of Metallic alloys in Aqueous Solutions

  • Habib, K.;AI-Mazeedi, H.
    • Corrosion Science and Technology
    • /
    • v.2 no.6
    • /
    • pp.277-282
    • /
    • 2003
  • Holographic interferometry, an electromagnetic method, was used to study corrosion of carbon steel, aluminum and copper nickel alloys in NaOH, KCI and $H_2SO_4$ solutions respectively. The technique, called electrochemical emission spectroscopy, consisted of in-situ monitoring of changes in the number of fringe evolutions during the corrosion process. It allowed a detailed picture of anodic dissolution rate changes of alloys. The results were compared to common corrosion measurement methods such as linear polarization resistance measurements and electrochemical impedance spectroscopy. A good agreement between both data was found, thus indicating that holographic interferometry can be a very powerful technique for in-situ corrosion monitoring.

Template Synthesis of $Ni(OH)_2$ nanowires by Electrochemical Process

  • Zhang, Wentao;Beili, Pang;Lee, Hong-Ro
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.68-68
    • /
    • 2008
  • There are several methods for oxide coating on metals, such as aluminum or carbon nanotubes(CNTs). Usually CVD method is introduced for various oxide coating on CNTs. Another method is electrochemical method which use potential-pH diagram for oxide coating on metal or CNTs. In this experiment, electrochemical coating parameter for oxide coating on aluminum template modified by acids and hydrogen peroxide ($H_2O_2$) were examined. SEM micrographs displayed clearly $Ni(OH)_2$ coating on template. For confirmation of electrochemical method application to EDLC electrode material fabrication, EDS spectrum was analyzed.

  • PDF

Electrochemical extraction of uranium on the gallium and cadmium reactive electrodes in molten salt

  • Valeri Smolenski;Alena Novoselova
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.42-47
    • /
    • 2024
  • The electrochemical extraction of uranium in ternary low melting LiCl-KCl-CsCl eutectic on inert and reactive electrodes via different electrochemical techniques was investigated. It was established that the electrochemical reduction process of U(III) ions on the inert W electrode was irreversible and proceeded in one stage. On reactive liquid Ga and liquid Cd electrodes the reduction of uranium ions took place with the considerable depolarization with the formation of UGa2, UGa3 and UCd11 intermetallic compounds. Thermodynamic characteristics of uranium compounds and alloys were calculated. The conditions for the extraction of uranium from the electrolyte in the form of alloys on both liquid reactive electrodes via potentiostatic electrolysis were found.

Electrochemical Reduction of SiO2 Granules to One-Dimensional Si Rods Using Ag-Si Eutectic Alloy

  • Lee, Han Ju;Seo, Won-Chul;Lim, Taeho
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.392-398
    • /
    • 2020
  • Producing solar grade silicon using an inexpensive method is a key factor in lowering silicon solar cell costs; the direct electrochemical reduction of SiO2 in molten salt is one of the more promising candidates for manufacturing this silicon. In this study, SiO2 granules were electrochemically reduced in molten CaCl2 (850℃) using Ag-Si eutectic droplets that catalyze electrochemical reduction and purify the Si product. When Ag is used as the working electrode, the Ag-Si eutectic mixture is formed naturally during SiO2 reduction. However, since the Ag-Si eutectic droplets are liquid at 850℃, they are easily lost during the reduction process. To minimize the loss of liquid Ag-Si eutectic droplets, a cylindrical graphite container working electrode was introduced and Ag was added separately to the working electrode along with the SiO2 granules. The graphite container working electrode successfully prevented the loss of the Ag-Si eutectic droplets during reduction. As a result, the Ag-Si eutectic droplets acted as stable catalysts for the electrochemical reduction of SiO2, thereby producing one-dimensional Si rods through a mechanism similar to that of vapor-liquid-solid growth.