• Title/Summary/Keyword: Electrochemical gas sensor

Search Result 54, Processing Time 0.028 seconds

Effect of Specific Surface Area of Activated Carbon Fiber on Harmful Gas Adsorption and Electrochemical Responses (활성탄소섬유의 비표면적에 따른 유해가스 흡착 및 전기화학적 감응 특성)

  • Kang, Jin Kyun;Chung, Yong Sik;Bai, Byong Chol;Ryu, Ji Hyun
    • Journal of Adhesion and Interface
    • /
    • v.21 no.2
    • /
    • pp.51-57
    • /
    • 2020
  • Recently, there has been growing interest in the study of removal of harmful and hazardous pollutants emitted by industrial activities. In this study, we have developed porous activated carbon fibers prepared by a water vapor activation method and analyzed the adsorptions of the harmful gases with electrochemical responses of activated carbon fibers. To control the uniformity of pore structures, active reaction areas, and active sites, the reaction conditions of activation temperatures were varied from 750 to 850 ℃ with the predetermined reaction time intervals (30 to 240 min). The SO2 and NO gas adsorptions of activated carbon fibers prepared by various reaction conditions were analyzed and monitored by electrochemical sensor responses. In particular, the activated carbon fibers prepared at the reaction temperature of 850 ℃ and time of 45 min showed the highest specific surface area (1,041.9 ㎡/g) and pore characteristics (0.42 ㎤/g), and excellent adsorption capabilities of SO2 (1.061 mg/g) and NO (1.210 mg/g) gases, respectively.

YSZ(yttria-stablilized ziroconia) 박막을 이용한 센서셀의 산소감응

  • 배정운;박준용;황순원;김기동;조영아;전진석;최동수;염근영
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.128-128
    • /
    • 1999
  • 산소이온 전도체로 잘 알려진 Yttira-Stabilizd Ziroconia(TSZ)는 연료전지, oxygen pumps, chemical gas sensor 등 다양한 electrochemical divices에 이용되는 고체 전해질의 하나이다. 특히 YSZ는 oxygen 및 oxygen과 평형상태에 있는 gas들을 검출하는 sensor의 electrolyte로서 가장 많이 쓰이고 있다. 현재 상용화되어 있는 YSZ Sensor는 전통적인 bulk 형태의 ceramic으로 제작된 것으로 충분한 ionic conductivity를 얻기 위해서는 $600^{\circ}C$이상의 operating temperature를 필요로 하나 YSZ를 박막으로 제조시 낮은 operating temperature를 뿐만 아니라 sensor의 소형화, 낮은 ohmic loss 및 다양한 응용이 가능한 장점을 가질 수 있다. 본 실험에서는 산소 이온 전도체로서 8mol%-YSZ 고체전해질을 RF-magnetron bias sputtering 법을 이용하여 증착하였다. 제조된 YSZ 박막을 이용한 산소감응 센서셀 구조는 SiO2/Ni-NiO/Pt/YSZ/Pt-기판이다. 센서셀의 정상상태에서의 기전력(electromotive force ; EMF)을 산소분압(Po:1.013$\times$103Ta ~1.013$\times$105Pa)과 측정온도(30$0^{\circ}C$~$700^{\circ}C$)를 변화시키며 측정하였다. 이론적인 기전력과 측정값 사이의 편차는 Po:1.565$\times$104Pa 이하의 산소분압에서는 컸지만 이 이상의 분압에서는 이론치에 근접한 값을 가졌다. 증착한 YSZ와 Ni-NiO 박막의 구조는 X-ray diffractometer(XRD)를 이용하여 결정구조를 알아 보았고, TSZ 박막의 표면 morphology 관찰은 Scanning electron microscopy(SEM) 이용하였다. 박막의 조성분석은 X-ray energy dispersive analysis(EDX)을 사용하였다.

  • PDF

Carbon Dioxide Sensor Substrate for Surface-mounted Packaging

  • Han, Hyeuk-Jin;Kim, Tae Wan;Park, Kwang-Min;Park, Chong-Ook
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.159-164
    • /
    • 2015
  • Solid state electrochemical and chemo-resistive gas sensors have been used widely but can operate only under high temperature. For reducing the power consumption and optimizing the structure of the substrate of these sensors, we conducted device and circuit simulations using the COMSOL Multiphysics simulator. For assessing the effective types of substrate and heat isolation, we conducted three-dimensional thermal simulations in two separate parts; (a) by changing the shape of the contacting holes and (b) punching additional holes on the substrate. Thus, it was possible to achieve high temperature in the sensor end of the substrate while maintaining low power consumption, and temperature in the circuit.

Study on Porous Silicon Sensors to Measure Low Alcohol Concentration (저농도 알코올 측정을 위한 다공질 실리콘 센서에 관한 연구)

  • Kim Seong-Jeen
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.3
    • /
    • pp.130-133
    • /
    • 1999
  • In this work, a capacitance-type alcohol gas sensor using porous silicon layer is developed to apply for breath alcohol measurement and its characteristics are estimated at room temperature. Current alcohol sensors using metal oxides such as tin-oxide are not only difficult to measure low alcohol concentration, but also should heat at $200\;to\;400^{\circ}C$ to improve the sensitivity. But the sensor using porous silicon layer has good sensitivity even at room temperature by very large effective surface area and suitable structure to fabricate integrated micro sensors. In the experiment, the capacitance was measured for the range of 0 to $0.5\%$ alcohol concentration with the interval of $0.05\%$, in which alcohol solution was kept at 25, 36, and $45^{\circ}C$ by a heater. As the result, good linearity was observed and the capacitance increased about 1.1, 2.6 and $4.6\%$ per the increment of $0.1\%$ alcohol concentration each temperature, respectively, at the frequency of 120 Hz.

Design and implementation of flooding-based query model in wireless sensor networks for indoor environmental monitoring system (실내환경 모니터링시스템을 위한 무선 센서네트워크에서의 플러딩 방식의 질의모델 설계 및 구현)

  • Lee, Seung-Chul;Jung, Sang-Joong;Lee, Young-Dong;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.168-177
    • /
    • 2008
  • An indoor environmental monitoring system using IEEE 802.15.4 based wireless sensor network is proposed to monitor the amount of pollutant entering to the room from outside and also the amount of pollutant that is generated in indoor by the building materials itself or human activities. Small-size, low-power wireless sensor node and low power electrochemical sensor board is designed to measure the condition of indoor environment in buildings such as home, offices, commercial premises and schools. In this paper, two query models, the broadcasting query protocol and flooding query protocol, were designed and programmed as a query-based routing protocol in wireless sensor network for an environment monitoring system. The flooding query routing protocol in environment monitoring is very effective as a power saving routing protocol and reliable data transmission between sensor nodes.

Conducting Metal Oxide Interdigitated Electrodes for Semiconducting Metal Oxide Gas Sensors

  • Shim, Young-Seok;Moon, Hi-Gyu;Kim, Do-Hong;Jang, Ho-Won;Yoon, Young-Soo;Yoon, Soek-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.65-65
    • /
    • 2011
  • We report the application of conducting metal oxide electrodes for semiconducting metal oxide gas sensors. Pt interdigitated electrodes have been commonly used for metal oxide gas sensor because of the low resistivity, excellent thermal and chemical stability of Pt. However, the high cost of Pt is an obstacle for the wide use of metal oxide gas sensors compared with its counterpart electrochemical gas sensors. Meanwhile, relatively low-cost conducting metal oxides are widely being used for light-emitting diodes, flat panel displays, solar cell and etc. In this work, we have fabricated $WO_3$ and $SnO_2$ thin film gas sensors using interdigitated electrodes of conducting metal oxides. Thin film gas sensors based on conducting metal oxides exhibited superior gas sensing properties than those using Pt interdigitated electrodes. The result was attributed to the low contact resistance between the conducting metal oxide and the sensing material. Consequently, we demonstrated the feasibility of conducting metal oxide interdigitated electrodes for novel gas sensors.

  • PDF

Development of Cylindrical Capacitive-Conductive Sensor to Evaluate Insulating Degradation for FCEV Stack (차량용 연료전지 스택의 절연열화 진단을 위한 원통형 정전용량-전기전도도 센서개발)

  • Kim, Jae-Hoon;Kim, Ju-Han;Kim, Yoon-Hyung;Cui, Jiang-Yue;Han, Sang-Ok;Yong, Gee-Joong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.3
    • /
    • pp.317-324
    • /
    • 2010
  • It was used as measuring system to diagnose insulating condition, by which was kept a insulating resistance of inner stack and at the same time was cooled electrochemical heat of reaction of FCEV(fuel cell electric vehicle) stack that used a compressed hydrogen gas reacting with oxygen in accordance with variation on thermal degradation of nonconductive heat transfer fluid. Consequently it was developed a cylindrical multi-terminal capacitive-conductive sensor that could be attached to the internal surface of cooling system pipe to evaluate capacitance and conductivity of heat transfer fluid.

Detection of Voletile Organic Compounds by Using DBR Porous Silicon (DBR 다공성 실리콘을 이용한 휘발성 유기화합물의 감지)

  • Park, Cheol Young
    • Journal of Integrative Natural Science
    • /
    • v.2 no.4
    • /
    • pp.275-279
    • /
    • 2009
  • Recently, number of studies for porous silicon (PSi) have been investigated by many researchers. Multistructured porous silicon such as a distributed Bragg reflector (DBR) PSi, has been a topic of interest, because of its unique optical properties. DBR PSi were prepared by using an electrochemical etch of $P{^+}{^+}$-type silicon wafer with resistivity between 0.1 and $10m{\Omega}cm$. The electrochemical etch with square wave current density results in two different refractive indices in the porous layer. In this work, DBR porous silicon chips for a simple and portable organic vapor-sensing device have fabricated. The optical characteristics of DBR PSi have been investigated. DBR porous silicon have been characterized by FT-IR and Ocean optics 2000 spectrometer. The device used DBR PSi chip has been demonstrated as an excellent gas sensor, showing a great senstivity to organic vapor at room temperature.

  • PDF

SnO2 Semiconducting Nanowires Network and Its NO2 Gas Sensor Application (SnO2 반도체 나노선 네트웍 구조를 이용한 NO2 가스센서 소자 구현)

  • Kim, Jeong-Yeon;Kim, Byeong-Guk;Choi, Si-Hyuk;Park, Jae-Gwan;Park, Jae-Hwan
    • Korean Journal of Materials Research
    • /
    • v.20 no.4
    • /
    • pp.223-227
    • /
    • 2010
  • Recently, one-dimensional semiconducting nanomaterials have attracted considerable interest for their potential as building blocks for fabricating various nanodevices. Among these semiconducting nanomaterials,, $SnO_2$ nanostructures including nanowires, nanorods, nanobelts, and nanotubes were successfully synthesized and their electrochemical properties were evaluated. Although $SnO_2$ nanowires and nanobelts exhibit fascinating gas sensing characteristics, there are still significant difficulties in using them for device applications. The crucial problem is the alignment of the nanowires. Each nanowire should be attached on each die using arduous e-beam or photolithography, which is quite an undesirable process in terms of mass production in the current semiconductor industry. In this study, a simple process for making sensitive $SnO_2$ nanowire-based gas sensors by using a standard semiconducting fabrication process was studied. The nanowires were aligned in-situ during nanowire synthesis by thermal CVD process and a nanowire network structure between the electrodes was obtained. The $SnO_2$ nanowire network was floated upon the Si substrate by separating an Au catalyst between the electrodes. As the electric current is transported along the networks of the nanowires, not along the surface layer on the substrate, the gas sensitivities could be maximized in this networked and floated structure. By varying the nanowire density and the distance between the electrodes, several types of nanowire network were fabricated. The $NO_2$ gas sensitivity was 30~200 when the $NO_2$ concentration was 5~20ppm. The response time was ca. 30~110 sec.

Interference of Sulphur Dioxide on Balloon-borne Electrochemical Concentration Cell Ozone Sensors over the Mexico City Metropolitan Area

  • Kanda, Isao;Basaldud, Roberto;Horikoshi, Nobuji;Okazaki, Yukiyo;Benitez-Garcia, Sandy-Edith;Ortinez, Abraham;Benitez, Victor Ramos;Cardenas, Beatriz;Wakamatsu, Shinji
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.3
    • /
    • pp.162-174
    • /
    • 2014
  • An abnormal decrease in ozonesonde sensor signal occurred during air-pollution study campaigns in November 2011 and March 2012 in Mexico City Metropolitan Area (MCMA). Sharp drops in sensor signal around 5 km above sea level and above were observed in November 2011, and a reduction of signal over a broad range of altitude was observed in the convective boundary layer in March 2012. Circumstantial evidence indicated that $SO_2$ gas interfered with the electrochemical concentration cell (ECC) ozone sensors in the ozonesonde and that this interference was the cause of the reduced sensor signal output. The sharp drops in November 2011 were attributed to the $SO_2$ plume from Popocat$\acute{e}$petl volcano southeast of MCMA. Experiments on the response of the ECC sensor to representative atmospheric trace gases showed that only $SO_2$ could cause the observed abrupt drops in sensor signal. The vertical profile of the plume reproduced by a Lagrangian particle diffusion simulation supported this finding. A near-ground reduction in the sensor signal in March 2012 was attributed to an $SO_2$ plume from the Tula industrial complex north-west of MCMA. Before and at the time of ozonesonde launch, intermittent high $SO_2$ concentrations were recorded at ground-level monitoring stations north of MCMA. The difference between the $O_3$ concentration measured by the ozonesonde and that recorded by a UV-based $O_3$ monitor was consistent with the $SO_2$ concentration recorded by a UV-based monitor on the ground. The vertical profiles of the plumes estimated by Lagrangian particle diffusion simulation agreed fairly well with the observed profile. Statistical analysis of the wind field in MCMA revealed that the effect Popocat$\acute{e}$petl was most likely to have occurred from June to October, whereas the effect of the industries north of MCMA, including the Tula complex, was predicted to occur throughout the year.