• Title/Summary/Keyword: Electrochemical detection

Search Result 339, Processing Time 0.026 seconds

Analysis and Mechanistic Investigation of Redox Process of 2-Amino-1-cyclopentene-1-dithiocarboxylate by Adsorptive Stripping Voltammetry on Glassy Carbon Electrode (Glassy Carbon 전극에서의 벗김 전압-전류법을 이용한 2-Amino-1-cyclopentene-1-dithiocarboxylate 의 분석과 전극 반응 메카니즘의 연구)

  • Yoon-Bo Shim;Duk-Soo Park;Sung-Nak Choi;Mi-Sook Won
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.1
    • /
    • pp.37-47
    • /
    • 1988
  • The electrochemical behavior of 2-Amino-1-cyclopentene-1-dithiocarboxylate (acdc) was investigated by the use of polarography, cyclic voltammetry and cathodic stripping voltammetry at glassy carbon electrode. In this study, it was found that the dimer of the acdc was deposited on the glassy carbon electrode via one-electron oxidation process at +0.25V vs. SCE. The ring formation between two dithio group occurs along with the elimination of one sulfur atom. The elimination of sulfur atom occurs via two electron oxidation process at +0.8V vs. SCE. The most sensitive cathodic stripping peak due to the formation of the dimer was observed at -0.85V vs. SCE. The peak relationship between current and concentration was fairly linear in the range of 3${\times}10^{-5}{\sim}1.0{\times}10^{-6}$M. The preconcentration procedure enhanced the sensitivity about 100 times for the analysis of acdc using diffusion current. Detection limit was found to be $2.5{\times}10^{-7}$M and relative standard deviation was ${\pm}$4.1 % at $5.0{\times}10^{-6}$M DC polarography.

  • PDF

Effects of Some Crude Drug Extracts on the Brain Neurotransmitters in the Ethanol-Treated Rats (수종의 생약 추출물이 에탄올 투여 흰쥐의 뇌 부위별 신경전달물질에 미치는 영향)

  • Linh, Pham-Tuan;Lee, Soon-Chul;Kim, Young-Ho;Hong, Seon-Pyo;Song, Chang-Woo;Kang, Jong-Seong
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.630-635
    • /
    • 2000
  • The concentration of neurotransmitters in rat brain was determined by HPLC-ECD (electrochemical detection) method and the effects of methanol extracts of some crude drugs, such as Polygala Radix, Myristicae Semen, Zizyphi Semen, Acori graminei Rhizoma, Visci Herba, Liriopsis Tuber, Myrrha on the concentration of neurotransmitters in the ethanol-treated rat brain were investigated. By the administration of ethanol, dopamine (DA), 3, 4-dihydroxyphenyl acetic acid (DOPAC) and serotonin (5-HT) levels in frontal cortex and 5-HT level in hippocampus were significantly increased compared with the neurotransmitter levels in the brain of saline-treated rats. The ${\gamma}$-aminobutyric acid (GABA) level in frontal cortex was decreased by the same treatment. There was a tendency that the DA level in frontal cortex and striatum of ethanol-treated rats were increased by the administration of crude drug extracts. Especially, Myrrha and Visci Herba significantly increased the DA level of frontal cortex in ethanol-treated rats, while they significantly decreased the 5-HT level in the same region of the brain. GABA level in striatum of ethanol-treated rats was significantly decreased by Myristicae Semen, Visci Herba and Myrrha. These results suggest that the tested crude drug extracts have selective interaction with neurotransmitters in specified region of central nervous system.

  • PDF

Detection of Urinary 8-Hydroxyguanine Adduct as Exposure Biomarker for Oxidative Stress (산화적스트레스에 대한 노출척도로서 뇨중 8-Hydroxyguanine Adduct의 측정)

  • 유아선;김윤신;모인필;마응천;조명행
    • Toxicological Research
    • /
    • v.14 no.4
    • /
    • pp.515-523
    • /
    • 1998
  • Oxidative stress by reactive oxygen species (ROS) damages cellular DNA, RNA, proteins, lipids and others causing various diseases such as cancer, arthritis, and heart diseases. 8-Hydroxyguanine (8-OHG) is one of the products formed from DNA or RNA damaged by ROS. Since high amounts of 8-OHG can be excreted in urine, it may serve as a potential biomarker indicating the level of oxidative damage to nucleic acids. Residents in industrial area with severe air pollution are expected to be affected by higher level of oxidative stress from pollutants like polyaromatic hydrocarbons (PAHs), etc. Smokers are also expected to be damaged by higher level of oxidative stress from cigarette smoke components like PAHs than non-smokers. To examine if the determination of the urinary concentration of 8-OHG could be used as exposure biomarker for the oxidative stress caused by air-pollutants, this study was performed to determine and compare the urinary concentrations of 8-OHG in smokers and non-smokers, or non-polluted area residents and polluted area residents. Urine samples were collected and purified by a strong cation exchange and cellulose partition column, then analyzed by HPLC with electrochemical detector at 600 ㎷ potential. Concentrations of urinary 8-OHG in non-smokers and smokers of Seoul area college male students were determined as 15.12$\pm$9.68 (ng/mg creatinine) and 34.72$\pm$11.72 (ng/mg creatinine), respectively, showing significantly higher level of 8-OHG in smokers than in non-smokers. Urine samples of elementary school students were collected from Sokcho area, which is known to be non-polluted, and 3 representative polluted areas; Yocheon industrial area, Ulsan urban and Ulsan industrial area. The concentrations of 8-OHG in these samples were 12.42$\pm$8.27 (ng/ mg creatinine, Sokcho), 22.55$\pm$9.12 (ng/mg creatinine, Yocheon), 17.41$\pm$2.30 (ng/mg creatinine, Ulsan urban), 55.04$\pm$39.73 (ng/mg creatinine, Ulsan industrial). Thus, samples from polluted area tend to have higher level of 8-OHG and the levels of Yocheon and Ulsan industrial area were significantly higher than that of Sokcho area. The results indicate that the residents of polluted industrial area or smokers are more severely exposed to oxidative stress probably caused by air pollutants like PAHs. Thus, the determination of urinary 8-OHG concentration could be used as biomarker for the extent of body exposure to oxidative stress caused by various pollutants.

  • PDF

Sensitive and Selective Electrochemical Glucose Biosensor Based on a Carbon Nanotube Electronic Film (탄소나노튜브 전자 필름을 이용한 고감도-고선택성 전기화학 글루코스 센서)

  • Lee, Seung-Woo;Lee, Dongwook;Seo, Byeong-Gwuan
    • Applied Chemistry for Engineering
    • /
    • v.33 no.2
    • /
    • pp.188-194
    • /
    • 2022
  • This work presents a non-destructive and straightforward approach to assemble a large-scale conductive electronic film made of a pre-treated single-walled carbon nanotube (SWCNT) solution. For effective electron transfer between the immobilized enzyme and SWCNT electronic film, we optimized the pre-treatment step of SWCNT with p-terphenyl-4,4"-dithiol and dithiothreitol. Glucose oxidase (GOx, a model enzyme in this study) was immobilized on the SWCNT electronic film following the positively charged polyelectrolyte layer deposition. The glucose detection was realized through effective electron transfer between the immobilized GOx and SWCNT electronic film at the negative potential value (-0.45 V vs. Ag/AgCl). The SWCNT electronic film-based glucose biosensor exhibited a sensitivity of 98 ㎂/mM·cm2. In addition, the SWCNT electronic film biosensor showed the excellent selectivity (less than 4 % change) against a variety of redox-active interfering substances, such as ascorbic acid, uric acid, dopamine, and acetaminophen, by avoiding co-oxidation of the interfering substances at the negative potential value.

Development of electrochemical biosensor for determination of galactose (4갈락토오즈 측정을 위한 전기화학적 바이오센서 개발)

  • Park, Kap Soo;Cho, Soon Sam;Quan, De;Lee, Jae Seon;Cha, Geun Sig;Nam, Hakhyun
    • Analytical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.393-399
    • /
    • 2007
  • In principle, the blood galactose level may be determined conveniently with a strip-type biosensor similar to that for glucose. In this study, we describe the development of a disposable galactose biosensor strip for point-of-care testing. The sensor strip is constructed with screen-printed carbon paste electrode (SPCE) and sample amount (< $100{\mu}L$). The developed strip the galactose level in less than 90 s using bienzymatic system of galactose oxidase (GAO) and horseradish peroxidase (HRP). The effects of pH, mediator (1,1-ferrocenedimethanol) concentration, ratio of enzymes, and applied potential were determined preliminarily with glassy carbon electrodes, and optimized further with the strip-type electrodes. The sensor exhibits linear response in the range of $0{\sim}400{\mu}M$ ($r^2$ = 0.997, S/N = 3). Since a low working potential, in principle, the fabricated disposable galactose biosensor has -100 mV (vs. Ag/AgCl), it is applied for the detection of galactose, interfering responses from common interferents such as ascorbic acid, uric acid and acetaminophen could be minimized. The sensor has been used to determine the total galactose level in standard samples with satisfactory reproducibility (CV = 5 %).

Voltammetric Sensor Incorporated with Conductive Polymer, Tyrosinase, and Ionic Liquid Electrolyte for Bisphenol F (전도성고분자, 티로시나아제 효소 및 이온성 액체 전해질을 융합한 전압전류법 기반의 비스페놀F 검출 센서)

  • Sung Eun Ji;Sang Hyuk Lee;Hye Jin Lee
    • Applied Chemistry for Engineering
    • /
    • v.34 no.3
    • /
    • pp.258-263
    • /
    • 2023
  • In this study, conductive polymers and the enzyme tyrosinase (Tyr) were deposited on the surface of a screen printed carbon electrode (SPCE), which can be fabricated as a disposable sensor chip, and applied to the detection of bisphenol F (BPF), an endocrine disruptor with proven links to male diseases and thyroid disorders, using electrochemical methods. On the surface of the SPCE working electrode, which was negatively charged by oxygen plasma treatment, a positively charged conductive polymer, poly(diallyldimethyl ammonium chloride) (PDDA), a negatively charged polymer compound, poly(sodium 4-styrenesulfonate) (PSS), and another layer of PDDA were layered by electrostatic attraction in the order of PDDA, PSS, and finally PDDA. Then, a layer of Tyr, which was negatively charged due to pH adjustment to 7.0, was added to create a PDDA-PSS-PDDA-Tyr sensor for BPF. When the electrode sensor is exposed to a BPF solution, which is the substrate and target analyte, 4,4'-methylenebis(cyclohexa-3,5-diene-1,2-dione) is generated by an oxidation reaction with the Tyr enzyme on the electrode surface. The reduction process of the product at 0.1 V (vs. Ag/AgCl) generating 4,4'-methylenebis(benzene-1,2-diol) was measured using cyclic and differential pulse voltammetries, resulting in a change in the peak current with respect to the concentration of BPF. In addition, we compared the detection performance of BPF using an ionic liquid electrolyte as an alternative to phosphate-buffered saline, which has been used in many previous sensing studies. Furthermore, the selectivity of bisphenol S, which acts as an interfering substance with a similar structure to BPF, was investigated. Finally, we demonstrated the practical applicability of the sensor by applying it to analyze the concentration of BPF in real samples prepared in the laboratory.

Relationship between Clozapine-Induced Therapeutic Responses and Plasma Homovanillic Acid and 5-Hydroxyindoleacetic Acid Levels in Patients with Chronic Schizophrenia (만성 정신분열증 환자에서 Clozapine의 치료반응과 혈장 Homovanillic Acid 및 5-Hydroxyindoleacetic Acid 농도와의 관계)

  • Kim, Chan-Hyung;Lee, Hong Shick;Kim, Kwang Hyeon;Yoo, Kae Joon
    • Korean Journal of Biological Psychiatry
    • /
    • v.4 no.1
    • /
    • pp.84-94
    • /
    • 1997
  • This study was done to examine changes of plasma homovanillic acid(HVA), 5-hydroxyindoleacetic acid(5-HIAA), and HVA/5-HIAA ratio during an 8-week clozapine trial and to investigate the relationship between the plasma monoamine metabolites and treatment responses. Twenty-seven chronic schizophrenic patiens were treated for 8 weeks with clozapine. The psychopathology was assessed at baseline just clozapine trial and then every 2 weeks until the end of 8-week clozapine treatment using the Positive and Negative Syndrome Scale(PANSS) and the Clinical Global Impression scale(CGI). The plasma HVA and 5-HIAA levels were measured also biweekly using high preformance liquid chromatography with electrochemical detection method. Plasma HVA and 5-HIAA levels were significantly decreased during a 8-week clozapine treatment, although plasma HVA/5-HIAA ratio showed no significant change. The changes of plasma HVA levels were in significant correlations with the changes of PANSS positive scores, of general psychophathology scores, and changes of total socres. The changes of plasma 5-HIAA levels were in signfificant correlations with the changes of PANSS negative scores. But the changes of plasma HVA/5-HIAA ratio had no significant correlation with any PANSS subscale score changes. 48% of the patients treated with clozapine was categorized as responders, who showed at least a 20% decrease in PANSS total socre and a CGI severity score of mildly ill or less(${\leq}3$) at the end pint of the study. The baseline plasma HVA levels and HVA/5-HIAA ratio were significantly higher in responders(N=13) than in nonresponders (N=14). But no significant difference in baseline levels of plasma 5-HIAA was found between responders and nonresponders. At the end point of the study, there was significant difference in the change of plasma HVA between responders(40.3% decrement) and nonresponders(3.1% increment). But no signficant differences in the change of plasma 5-HIAA and the change of plasma HVA/5-HIAA ratio between responders and nonresponders were observed. These results suggest that the antipsychotic effect of clozapine on positive symptoms may be associated with dopaminergic blocking activity, and that on negative symptoms may be associated with serotonergic blocking activity. The baseline plasma HVA levels and the change of HVA levels from baseline may be useful predictors of treatment response with clozapine.

  • PDF

Electrochemical Evaluation of Cadmium and Lead by Thiolated Carbon Nanotube Electrodes (티올화된 탄소나노튜브 전극을 이용한 카드뮴과 납의 전기화학적 분석)

  • Yang, Jongwon;Kim, Lae-Hyun;Kwon, Yongchai
    • Applied Chemistry for Engineering
    • /
    • v.24 no.5
    • /
    • pp.551-557
    • /
    • 2013
  • In the present study, pristine carbon nanotube (p-CNT) and thiolated carbon naotube (t-CNT) electrodes were investigated to improve their detectabilities for cadmium (Cd) and lead (Pb). In addition, we evaluate which reaction mechanism is used when the electrolyte contains both Cd and Pb metals. Square wave stripping was employed for analyzing the sensitivity for the metals. A frequency of 30 Hz, a deposition potential of -1.2 V vs. Ag/AgCl and a deposition time of 300 s were used as optimal SWSV parameters. t-CNT electrodes show the better sensitivity for both Cd and Pb metals than that of p-CNT electrodes. In case of Cd, sensitivities of p-CNT and t-CNT electrodes were $3.1{\mu}A/{\mu}M$ and $4.6{\mu}A/{\mu}M$, respectively, while the sensitivities for Pb were $6.5{\mu}A/{\mu}M$ (p-CNT) and $9.9{\mu}A/{\mu}M$ (t-CNT), respectively. The better sensitivity of p-CNT electrodes is due to the enhancement in the reaction rate of metal ions that are facilitated by thiol groups attached on the surface of CNT. When sensitivity was measured for the detection of Cd and Pb metals present simultaneously in the electrolyte, Pb indicates better sensitivity than Cd irrespective of electrode types. It is ascribed to the low standard electrode potential of Pb, which then promotes the possibility of oxidation reaction of the Pb metal ions. In turn, the Pb metal ions are deposited on the electrode surface faster than that of Cd metal ions and cover the electrode surface during deposition step, and thus Pb metals that cover the large portion of the surface are more easily stripped than that of Cd metals during stripping step.

STUDY ON THE RELATIONSHIP BETWEEN ONTOGENY OF SEROTONIN SYSTEM AND PSYCHOPATHOLOGY IN CONDUCT DISORDER (행동장애에 있어서 Serotonin계의 개체발생적인 과정과 정신병리와의 상호관계에 관한 연구)

  • Shin, Sun-Woong;Shin, Min-Sup;Hwang, Jun-Won;Kim, Boong-Nyun;Cho, Soo-Churl
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.14 no.1
    • /
    • pp.112-122
    • /
    • 2003
  • Objectives:Considerable data indicate that diminished serotonergic activity is related to aggressive behavior. In order to understand the biological etiology in conduct disorder, we studied the relationships of plasma serotonin and 5-HIAA levels in conduct disorders to measures of aggression, violation of rules and oppositional defiant behavior. Methods:Subjects were selected from inpatients and outpatients department of the Division of Child and Adolescent Psychiatry of Seoul National University Hospital. 41 conduct disorders(18 childhoodonset type, 23 adolescent-onset type) and 23 normal controls were included in this study. For the assessment of aggression, rule violation and oppositional behavior, parents completed the rating scale for conduct disorder and oppositional behavior based on the DSM-IV diagnostic criteria. Plasma serotonin and 5-HIAA levels were determined by HPLC with electrochemical detection. Results:1) Plasma 5-HT and 5-HIAA levels were not significantly different among childhood-onset conduct disorder, adolescent-onset conduct disorder and normal control subjects. 2) No significant correlations were found between plasma 5-HT levels and aggression or rule violation. 3) Plasma 5-HT levels showed significant positive correlations with oppositional behavior both in childhood-onset conduct disorder and adolescent-onset conduct disorder. 4) Age-related changes were not found in plasma 5-HT and 5-HIAA levles. Conclusion:Our findings do not support the hypothesis that dysregulation of serotonergic function may be associated with aggresson. Instead, our data suggest that serotonergic function is more closely related with oppositional behavior than aggression.

  • PDF