• 제목/요약/키워드: Electrochemical Detection

검색결과 340건 처리시간 0.028초

Volatile Organic Compound Specific Detection by Electrochemical Signals Using a Cell-Based Sensor

  • Chung, Sang-Gwi;Kim, Jo-Chun;Park, Chong-Ho;Ahn, Woong-Shick;Kim, Yong-Wan;Choi, Jeong-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권1호
    • /
    • pp.145-152
    • /
    • 2008
  • A cell-based in vitro exposure system was developed to determine whether oxidative stress plays a role in the cytotoxic effects of volatile organic compounds (VOCs) such as benzene, toluene, xylene, and chlorobenzene, using human epithelial HeLa cells. Thin films based on cysteine-terminated synthetic oligopeptides were fabricated for immobilization of the HeLa cells on a gold (Au) substrate. In addition, an immobilized cell-based sensor was applied to the electrochemical detection of the VOCs. Layer formation and immobilization of the cells were investigated with surface plasmon resonance (SPR), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The adhered living cells were exposed to VOCs; this caused a change in the SPR angle and the VOC-specific electrochemical signal. In addition, VOC toxicity was found to correlate with the degree of nitric oxide (NO) generation and EIS. The primary reason for the marked increase in impedance was the change of aqueous electrolyte composition as a result of cell responses. The p53 and NF-${\kappa}B $ downregulation were closely related to the magnitude of growth inhibition associated with increasing concentrations of each VOC. Therefore, the proposed cell immobilization method, using a self-assembly technique and VOC-specific electrochemical signals, can be applied to construct a cell microarray for onsite VOC monitoring.

Electrochemical Biosensors for Biomedical and Clinical Applications: A Review

  • Rahman Md. Aminur;Park Deog-Su;Shim Yoon-Bo
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권5호
    • /
    • pp.271-282
    • /
    • 2005
  • There are strong demands for accurate, fast, and inexpensive devices in the medical diagnostic laboratories, such as biosensors and chemical sensors. Biosensors can provide the reliable and accurate informations on the desired biochemical parameters, which is an essential prerequisite for a patient before going for a treatment. They can be used for continuous measurements of metabolites, blood cations, gases, etc. Of these, electrochemical biosensors play an important role in the improvement of public health, because rapid detection, high sensitivity, small size, and specificity are achievable for clinical diagnostics. In this paper, the clinical applications with electrochemical biosensors are reviewed. An attempt is also made to highlight some of the trends that govern the research and developments of the important biosensors that are associated to clinical diagnosis.

Polydimethylsiloxane 채널과 indium tin oxide 전극을 이용한 일회용 전기화학적 검출 시스템 (Disposable Microchip-Based Electrochemical Detector Using Polydimethylsiloxane Channel and Indium Tin Oxide Electrode)

  • 이인제;강치중;김용상;김주호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.227-231
    • /
    • 2005
  • We have developed a microsystem with a capillary electrophoresis (CE) and an electrochemical detector (ECD). The microfabricated CE-ECD systems are adequate for a disposable type and the characteristics are optimized for an application to the electrochemical detection. The system was realized with polydimethylsiloxane (PDMS)-glass chip and indium tin oxide electrode. The injection and separation channels (80 um wide$\ast$40 um deep) were produced by moulding a PDMS against a microfabricated master with relatively simple and inexpensive methods. A CE-ECD systems were fabricated on the same substrate with the same fabrication procedure. The surface of PDMS layer and ITO-coated glass layer was treated with UV-Ozone to improve bonding strength and to enhance the effect of electroosmotic flow. For comparing the performance of the ITO electrodes with the gold electrodes, gold electrode microchip was fabricated with the same dimension. The running buffer was prepared by 10 mM 2-(N-morpholino)ethanesulfonic acid (MES) titrated to PH 6.5 using 0.1 N NaOH. We measured olectropherograms for the testing analytes consisted of catechol and dopamine with the different concentrations of 1 mM and 0.1 mM, respectively. The measured current peaks of dopamine and catechol are proportional to their concentrations. For comparing the performance of the ITO electrodes with the gold electrodes, electropherograms was measured for CE-ECD device with gold electrodes under the same conditions. Except for the base current level, the performances including sensitivity, stability, and resolution of CE-ECD microchip with ITO electrode are almost the same compared with gold electrode CE-ECD device. The disposable CE/ECD system showed similar results with the previously reported expensive system in the limit of detection and peak skew. When we are using disposable microchips, it is possible to avoid polishing electrode and reconditioning.

Detection of Human Papillomavirus in Male and Female Urine by Electrochemical DNA Chip and PCR Sequencing

  • Nilyanimit, Pornjarim;Wanlapakorn, Nasamon;Niruthisard, Somchai;Pohthipornthawat, Natkrita;Karalak, Anant;Laowahutanont, Piyawat;Phanuphak, Nittaya;Gemma, Nobuhiro;Poovorawan, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권9호
    • /
    • pp.5519-5525
    • /
    • 2013
  • Background: Cervical cancer is the second most common cancer in Thai women after breast cancer. Currently, the Papanicolaou (Pap) smear is the recommended procedure for cervical cancer screening in Thailand, but only a relatively small percentage of women follow this screening program. An alternative method to detect HPV genotypes associated with cervical cancer is self-sampling of urine, which is a more widely accepted method. Our study aimed to evaluate the prevalence of HPV in Thai women using urine and cervical swabs and prevalence of HPV in Thai men using urine samples. Materials and Methods: Tumorigenic HPV detection was accomplished by electrochemical DNA chip and PCR/direct sequencing. In addition to HPV prevalence, we report the concordance between different methods and sample types. One-hundred and sixteen women and 100 men were recruited. Histological examination revealed normal cytology in 52 women, atypical squamous cells of undetermined significance (ASCUS) in 9, low-grade squamous intraepithelial lesions (LSIL) in 24, and high-grade squamous intraepithelial lesions (HSIL) in 31. One-hundred men were classified as heterosexuals (n=45) and homosexuals (n=55). Results: The most prevalent HPV genotype in our study was HPV16. The HPV detection rate was generally lower in urine samples compared with cervical samples. Overall, there was good agreement for the detection of carcinogenic HPV from female cervical samples between the DNA chip and PCR/sequencing, with 88.8% total agreement and a kappa value of 0.76. In male urine samples, the level of agreement was higher in heterosexuals compared with homosexuals. Conclusions: Further improvement is required to increase an overall yield of HPV DNA detection in urine samples before clinical application of a urine-based HPV screening program. The electrochemical DNA chip test is a promising technique for carcinogenic HPV detection.

전기화학법을 이용한 DNA Hybridization 검출 센서의 개발 및 특성 해석 (Development of DNA Hybridization Detection Sensors and Analysis of Characteristics Using Electrochemical methods)

  • 옥진영;김도균;장정수;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.260-262
    • /
    • 2002
  • The determination of DNA hybridization can apply the molecular biology research. clinic diagnostics. bioengineering, environment monitoring, food science and other application area. So, The determination of hybridization is very important for the improvement of DNA detection system. In this study, we report the characterization of the DNA hybridization by the electricalchemical methods. The probe oligonucleotide was used to determine the amount of target oligonucleotide in solution using Methylen Blue(MB) as the electrochemical indicators. The cathodic peak currents($I_{peak}$) of MB were linearly related to the concentration of the target oligonucleotide sequence in the range $1[{\mu}M]{\sim}0.1[{\mu}M]$. The detection limit of this approach was 0.01[nM]. As a result, the match oligonucleotide(CR-1) was most stable state and the peak of redox current measured by DNA hybridization detection sensors by using electrochemical method seem to be similar to 1-mer terminal mismatch oligonucleotide(MR-3). The MR-2, MR-3, MR-22 and MR-33 have each mismatching sequence of central and terminal. With this set the role of point mutations was to be investigated. Terminal mismatch oligonucleotide (MR-3, 33) is shown more stable state than central mismatch oligonucleotide(MR-2, 22). And 1-mer mismatch oligonucleotide(MR-2 or 3) is shown more stable state than 2-mer mismatch oligonucleotide(MR-22 or 33).

  • PDF

Carbon Nanotube Film을 이용한 액체 전기화학 센서 (Liquid electrochemical sensors using carbon nanotube film)

  • 노재하;안상수;이창한;이상태;이문진;서동민;장지호
    • 센서학회지
    • /
    • 제30권4호
    • /
    • pp.255-260
    • /
    • 2021
  • We studied electrochemical sensors using printed carbon nanotube (CNT) film on a polyethylene terephthalate (PET) substrate. Multiwalled CNT films were printed on a PET substrate to study its feasibility as hazardous and noxious substances (HNS) detection sensor. The printed CNT film (PCF) with a 50 ㎛ thickness exhibited a specific resistance of 230 ohm. To determine the optimum sensor structure, a resistance-type PCF sensor (R-type PCF sensor) and a conductive-type PCF sensor (C-type PCF sensor) were fabricated and compared using diluted NH3 droplets with various concentrations. The response magnitude, response time, sensitivity, linearity, and limit of detection (LOD) were compared, and it was concluded that the C-type PCF sensor exhibited superior performance. By applying a C-Type PCF sensor, we confirmed the detection performance of 12 types of floating HNS and the response of the sensor with selectivity according to the degree of polarity.

Pathogen-Imprinted Polymer Film Integrated probe/Ti3C2Tx MXenes Electrochemical Sensor for Highly Sensitive Determination of Listeria Monocytogenes

  • Xiaohua, Jiang;Zhiwen, Lv;Wenjie, Ding;Ying, Zhang;Feng, Lin
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권4호
    • /
    • pp.431-437
    • /
    • 2022
  • As one of the most hazardous and deadliest pathogens, Listeria monocytogenes (LM) posed various serious diseases to the human being, thus designing effective strategy for its detection is of great significance. In this work, by preparing Ti3C2Tx MXenes nanoribbon (Ti3C2TxR) as carrier and selecting thionine (Th) acted simultaneously as signal probe and functional monomer, a LM pathogen-imprinted polymers (PIP) integrated probe electrochemical sensor was design to monitor LM for the first time, that was carried out through the electropolymerization of Th on the Ti3C2TxR/GCE surface in the existence of LM. Upon eluting the templates from the LM imprinted cavities, the fabricated PIP/Ti3C2TxR/GCE sensor can rebound LM cells effectively. By recording the peak current of Th as the response signal, it can be weakened when LM cell was re-bound to the LM imprinted cavity on PIP/Ti3C2TxR/GCE, and the absolute values of peak current change increase with the increasement of LM concentrations. After optimizing three key parameters, a considerable low analytical limit (2 CFU mL-1) and wide linearity (10-108 CFU mL-1) for LM were achieved. In addition, the experiments demonstrated that the PIP/Ti3C2TxR sensor offers satisfactory selectivity, reproducibility and stability.