• 제목/요약/키워드: Electro reduction

검색결과 245건 처리시간 0.023초

정유 공장에서 발생된 폐수 슬러지의 최적 감량화 방안 연구 (Study of optimal reduction plan for wastewater sludge generated from oil refinery)

  • 최재우;정종민;심나탈리아;이상협;박철희
    • 상하수도학회지
    • /
    • 제24권4호
    • /
    • pp.395-406
    • /
    • 2010
  • In this study, anaerobic digestion, electro-oxidation and electro-fenton oxidation processes were investigated to reduce oily refinery sludge. Anaerobic digestion process was not suitable for oily activated sludge reduction because of characteristics itself and, as experimental results revealed, reduction efficiency was low for electro-oxidation process. However, 40% total suspended solid reduction of oily activated sludge was obtained by electro-fenton oxidation process, operating at pH=1, 0.5 A and $Fe^{2+}$:$H_2O_2$ ratio = 1:30. In addition, higher reduction efficiency was obtained as reaction time was increased (30, 60, 90, 120 min) despite of low $H_2O_2$ concentration. From the results, it has been investigated that electro-fenton oxidation is efficient process for oily activated sludge reduction.

실험적 해석을 통한 차량용 교류발전기 소음 저감 특성 연구 (A Study of AC Generator Noise Reduction Characteristics of Automobile Using Experimental Analysis)

  • 김대원;신중호
    • 소음진동
    • /
    • 제8권1호
    • /
    • pp.112-121
    • /
    • 1998
  • In this report, Experimental analysis for main factors and analyzing methods of electro-magnetic noise and no loading noise was conducted because of noise of AC generator, which is peripheral equipment by reduction of engine noise that would be the main cause of vehicle radiation noise. In addition, This is intended to suggest the noise reduction development basis of AC generator for actual fan and electro-magnetic noise by making-analyzing-testing it's sample.

  • PDF

Electro-Chemical Reduction에 의한 $Hg_{1-x}Cd_{x}$Te재료의 특성 고찰 (A Research of the Characteristics of $Hg_{1-x}Cd_{x}$Te material by using Electro - Chemical Reduction)

  • 이상돈;김봉흡;강형부
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 춘계학술대회 논문집
    • /
    • pp.38-41
    • /
    • 1994
  • The method of passivation for protecting the $Hg_{1-x}Cd_{x}$Te surface is important device fabrication process. Because the surface components are highly reactive leading to its chemical and electrical instability. Especially. the material of detecting for infrared radiation, of which composition is x=0.2 or 0.3, is narrow bandgap semi- conductor. The narrow bandgap semi conductors are largely governed by the properties of the semiconductor surface. The narrow bandgap semi-conductors are largely governed by the properties of the semiconductor surface. The electro-chemical processing of $Hg_{1-x}Cd_{x}$Te allows rigorous control of the surface chemistry and provides an in-suit monitor of surface reaction. So electro-chemical reduction at specific potential can be selectively eliminated the undesirable species on the surface and mainpulated to reproducibly attain the desired stoichiometry. This method shows to assess the quality of chemically treated good $Hg_{1-x}Cd_{x}$Te surface.

  • PDF

EC-MBR 공정의 MLSS, 전류밀도 및 접촉시간이 막 오염 감소에 미치는 영향 모델링 (Modeling of the effect of current density and contact time on membrane fouling reduction in EC-MBR at different MLSS concentration)

  • 김완규;장인성
    • 상하수도학회지
    • /
    • 제33권2호
    • /
    • pp.111-119
    • /
    • 2019
  • Electro-coagulation process has been gained an attention recently because it could overcome the membrane fouling problems in MBR(Membrane bio-reactor). Effect of the key operational parameters in electro-coagulation, current density(${\rho}_i$) and contact time(t) on membrane fouling reduction was investigated in this study. A kinetic model for ${\rho}_i$ and t required to reduce the membrane fouling was suggested under different MLSS(mixed liquor suspended solids) concentration. Total 48 batch type experiments of electro-coagulations under different sets of current densities(2.5, 6, 12 and $24A/m^2$), contact times(0, 2, 6 and 12 hr) and MLSS concentration(4500, 6500 and 8500mg/L) were carried out. After each electro-coagulation under different conditions, a series of membrane filtration was performed to get information on how much of membrane fouling was reduced. The membrane fouling decreased as the ${\rho}_i$ and t increased but as MLSS decreased. Total fouling resistances, Rt (=Rc+Rf) were calculated and compared to those of the controls (Ro), which were obtained from the experiments without electro-coagulation. A kinetic approach for the fouling reduction rate (Rt/Ro) was carried out and three equations under different MLSS concentration were suggested: i) ${\rho}_i^{0.39}t=3.5$ (MLSS=4500 mg/L), ii) ${\rho}_i^{0.46}t=7.0$ (MLSS=6500 mg/L), iii) ${\rho}_i^{0.74}t=10.5$ (MLSS=8500 mg/L). These equations state that the product of ${\rho}_i$ and t needed to reduce the fouling in certain amounts (in this study, 10% of fouling reduction) is always constant.

저주파 전침 자극이 허벅지둘레 감소에 미치는 영향에 관한 단기 연구 (Comparative prospective short-term study on Effect of Electro-Acupuncture on thigh circumference)

  • 최승;이영진;최형석
    • 한방비만학회지
    • /
    • 제3권1호
    • /
    • pp.61-67
    • /
    • 2003
  • Objectives : To compare the reduction of thigh circumference between electro acupuncture treatment group and no treatment controlled group. Method : Trial was carried out 24 volunteers for 2 weeks. Volunteers were divided into 2 groups ; electro acupuncture and very low calorie diet group(n=8) or only very low calorie diet group(n=9). The main outcome of measure was the reduction of thigh circumference(cm) per weight loss(kg). Result: The main outcome measure showed no significant difference(p=0.14). There was no significant difference in weight loss(p=0.67) either.

  • PDF

무선 비디오 스트림 시스템 EMI 잡음 개선 방안 (Optimized Design Technique of The EMI(Electro Magnetic Interference) Noise Reduction for Wireless Video Stream System)

  • 박경진;김종민;나극환
    • 한국ITS학회 논문지
    • /
    • 제11권4호
    • /
    • pp.112-120
    • /
    • 2012
  • 본 논문에서는 무선으로 비디오를 데이터 전송하여 접근하는데 필요한 스트림 시스템을 구현하여 시스템 내에서 발생하는 EMI(Electro Magnetic Interference) 잡음을 각 인터페이스, 회로 그리고 PCB(Printed Circuit Board) 상에서 주파수 대역별로 분석하였고 각각 기능 블럭에 대한 잡음 개선 방안을 제시하였다. 개선방안으로 저역통과 대역 필터링, 고속 데이터 라인들의 내층 배선, 그라운드의 최적화를 수행하였다. 구현된 시스템은 EMI 규제치 30 ~ 230[MHz]대역과 230 ~ 1000[MHz]대역에서 각각 40[dBuV/m]와 47[dBuV/m]내로 약 2 ~ 20[dB] 마진을 확보하여 잡음 개선을 하였다.

극하근과 대원근에 적용한 전침이 견관절 기능 개선 및 통증 경감에 미치는 영향 (Effect of the Electro-acupuncture Stimulation into the Infraspinatus and the Teres Major for the Shoulder Function Improvement and Pain Reduction)

  • 장원석;배성수
    • The Journal of Korean Physical Therapy
    • /
    • 제19권6호
    • /
    • pp.43-47
    • /
    • 2007
  • Purpose: This study examined the effect of electro-acupuncture stimulation of the infraspinatus and teres major on the shoulder function reduction. The subjects consisted of 20 female patients with a shoulder dysfunction. Methods: The 20 female patients with shoulder dysfunction participated voluntary in this research. 10 minute electro-acupuncture stimulation (frequency: 5Hz, Intensity: below the pain threshold) with Infra-red therapy, 3 times per week given to the patients' Trigger point of the infraspinatus and teres major. The Visual Analog Scale (VAS), Apley's Scratch Test and Global Perceived Effect Scale (GPES) were examined before alter six applications. Results: There was a significant decrease in the VAS (p<0.05) and Apley's Scratch Test (p<0.05). In addition, there was statistically significant increase in the Global Perceived Effect Scale (p<0.05). Therefore, the infraspinatus and teres major is a very important muscle for the shoulder function. Conclusion: This data will be used to develop a treatment method for patients with a shoulder dysfunction. These results suggest that the electro-acupuncture stimulation into the infraspinatus and the teres major Trigger point is an effective intervention for patients with shoulder dysfunction and pain.

  • PDF

전기응집 분리 막 생물반응기의 막 오염 저감 (Membrane fouling reduction using electro-coagulation aided membrane bio-reactor)

  • 김완규;홍성준;장인성
    • 한국산학기술학회논문지
    • /
    • 제19권8호
    • /
    • pp.105-114
    • /
    • 2018
  • 전기응집 (Electro-coagulation)을 활용한 분리 막 생물반응기 (Membrane Bio-Reactor) 공정의 막 오염 저감 현상을 확인하고 이를 해석하고자 하였다. 전기응집의 주요 운전 인자인 전류밀도와 접촉시간 변화가 활성슬러지 혼합액의 막 여과에 미치는 영향을 관찰하고 전기응집 과정에서 발생하는 수산화금속염이 막 오염에 미치는 역할에 대해 연구하였다. 전류밀도를 $10A/m^2$으로 높게 유지한 경우에는 전기응집 시간이 증가하여도 막 오염 감소 효과가 크지 않은 반면 $2.5A/m^2$의 낮은 전류밀도 하에서는 전기응집 시간이 증가하면 추가적인 막 오염 감소가 관찰되었다. 즉, 막 오염을 감소시키는 전류밀도와 접촉시간의 곱이 전체 막 오염 저감 정도를 지배하고 있음을 확인하였다. 또한 주어진 전류밀도와 인가시간에서 입도분포는 크게 변화하지 않은 것으로 나타나 콜로이드 입자와 막 오염 저감과는 큰 관련성이 없는 것으로 판단되었다. 그러나 전기응집을 통해 생성된 수산화알루미늄 (인산알루미늄)이 막 여과 과정에서 동적 막 (Dynamic Membrane)을 형성하여 막 오염 현상을 완화하는 것으로 확인되었다. 전기응집에서 발생한 수산화금속염이 막 표면에 동적 막을 형성하고 이로 인해 유입수의 입자성분이 직접 막 표면과 내부에 침적되는 것을 방해하고 동적 막에 주로 쌓이게 함으로써 막 오염이 감소된 것이다. 본 연구에서 밝힌 수산화금속염에 의한 동적 막의 역할은 전기응집을 활용한 MBR 공정의 후 막 오염 감소 메커니즘을 해석하는데 중요한 역할을 한다고 결론지을 수 있다.

전기펜톤공정을 이용한 석유화학공장 폐활성슬러지의 감량화 가능성 평가 (A study on reduction of excess sludge in activated sludge system from a petrochemical plant using electro fenton process)

  • 정종민;김경일;심나타리아;박철희;이상협
    • 상하수도학회지
    • /
    • 제23권5호
    • /
    • pp.669-678
    • /
    • 2009
  • The reduction of excess activated sludge from petrochemical plant was investigated by the electro fenton (E-Fenton) process using electrogenerated hydroxyl radicals which lead to mineralization of activated sludge to $CO_2$, water and inorganic ions. Factors affecting the disintegration efficiency of excess activated sludge in E-Fenton process were examined in terms of five criteria: pH, $H_2O_2/Fe^{2+}$ molar ratio, current density, initial MLSS (mixed liquid suspended solids) concentration, $H_2O_2$ feeding mode. TSS total suspended solid and $TCOD_{cr}$ reduction rate increased with the increasing $H_2O_2/Fe^{2+}$ molar ratio and current density until 42 and $6.7 mA/cm^2$, respectively but further increase of $H_2O_2/Fe^{2+}$ molar ratio and current density would reduce the reduction rate. On the other hand, as expected, increasing pH and initial MLSS concentration of activated sludge decreas TSS and $TCOD_{cr}$ reduction rate. The E-Fenton process was gradually increased during first 30 minutes and then linearly proceed till 120 minutes. The optimal E-Fenton condition showed TSS reduction rate of 62~63% and $TCOD_{cr}$ (total chemical oxygen demand) reduction rate of 55~56%. Molar ratio $H_2O_2/Fe^{2+} = 42$ was determined as optimal E-Fenton condition with initial $Fe^{2+}$ dose of 5.4 mM and current density of $6.7{\sim}13.3 mA/cm^2$, initial MLSS of 7,600 mg/L and pH 2 were chosen as the most efficient E-Fenton condition.

체감의이인탕(體感薏苡仁湯) 복용(服用)과 전침시술(電鍼施術)이 체지방(體脂肪) 감소(減少)에 미치는 효과(效果) (한방치료((韓方治療)의 부분비만(部分肥滿) 개선(改善) 효과(效果)) (Effect of Chegamuiyiin-tang and Electro-lipolysis Acupuncture on the Reduction of Body Fat (Effect of Oriental Medicine on Localized Obesity))

  • 김선민;김길수
    • 한방비만학회지
    • /
    • 제2권1호
    • /
    • pp.13-23
    • /
    • 2002
  • Background & Methods: In order to study the effect of electro-lipolysis-acupuncture, 57 outpatients who have had herbal medication in Kirin Oriental Hospital were devided to two groups; acupuncture-treated group(46) vs non-acupuncture-treated group(11) Acupuncture-treated group was given electro-lipolysis-acupuncture at least two times a week and administered with herbal diet medication, whereas non-acupuncture-treated group was administered only with herbal diet medication. Results: Mean age, body weight and BMI of these two group at the start point of the treatment were $27.22({\pm}7.64)\;vs \;29.09({\pm}8.73),\;67.76({\pm}9.34)\;vs\;67.00({\pm}10.69),\;and\;26.20({\pm}3.02)\;vs\;26.14({\pm}4.10)$ in the order of acupuncture-treated and non-acupuncture groups. After one month of treatment, change rate of body weight, BMI, total fat, percentage of fat was significantly higher in acupuncture-treated group. Also the change rate of arm circumference, hip circumference and thigh circumference was significantly higher in acupuncture-treated group. The change rate of abdominal circumference and WHR of acupuncture-treated group was higher than that of non-acupuncture-treated group with no statistical significance. The circumference reduction rate according to herbal dieting program was higher in this order, abdomen, arms, chest, thighs and hips. On the other hand, chest circumference change rate over weight loss rate, which is the portion no acupuncture treatment was given to, and AMC change rate was higher in non-acupuncture-treated group. Conclusion: These results imply that herbal dieting program combined with electro-lipolysis-acupuncture is more effective on reducing body fat, size reduction of localized obesity and preservation of muscle than herbal prescription only dieting program.

  • PDF