• 제목/요약/키워드: Electro hydraulic control valve

검색결과 100건 처리시간 0.025초

유압모터 길들이기 자동시험 제어기 개발 (Development of the Auto-Aging Test Controller for a Hydraulic Motor)

  • 정규홍;신대영;서동진
    • 드라이브 ㆍ 컨트롤
    • /
    • 제12권4호
    • /
    • pp.28-34
    • /
    • 2015
  • Because heavy-duty construction vehicles such as excavators are required for good engine-room cooling capacity, a hydraulic gear motor is adopted in the cooling fan drive mechanism to actively control the output speed, instead of adopting the conventional ON/OFF type belt drive. While gear motors are normally limited to 140bars of operating pressure, those for the cooling fan are capable of operating at continuous pressures of up to 220bars. After assembly, all gear motors for high pressure must pass an aging test which is a kind of the wearing process between the gear teeth and motor housing. During the aging process with gradual pressure increments, gear sticking sometimes occurs due to abnormal wear, resulting in defects. This paper focuses on a gear-sticking free aging test controller that is designed together with the knowledge of an experienced operator and the analysis results of experimental data of the gear jamming phenomenon. From the aging experiment, it is demonstrated that the developed controller that can alter the setting pressure of the load pump is effective for stabilizing the abrupt increase in the motor input pressure, thus preventing the hydraulic motor from stopping. This is expected to be helpful for the reduction of defects and increase in productivity.

전기유압 속도제어 시스템의 궤환 선형화 및 이에 대한 디지틀 상태 궤환 제어의 구현 (Feedback Linearization of an Electro-Hydraulic Velocity Control System and the Implementation of the Digital State Feedback Controller)

  • 김영준;장효환
    • 대한기계학회논문집
    • /
    • 제16권6호
    • /
    • pp.1036-1055
    • /
    • 1992
  • 본 연구에서는 일단앞섬 상태추정기(one-step ahead state estimator)를 사용 하는 방법을 제안하였다. 이 방법은 비선형 시스템을 궤환 선형화하여 등가 선형모 델을 구한 후, 이 등가 선형 모델에 일단앞섬 상태추정기를 구성하여 디지틀 제어를 실현하는 방법으로서, 계측할 수 없는 상태를 추정할 수 있을 뿐 아니라, 선형시스템 에 대한 상태 추정기이므로 다음 단계의 상태를 비교적 정확하게 추정할 수 있어서 궤 환 선형화시 요구되는 연속적인 상태 궤환에 근사시킬 수 있고, 직접 궤환 선형화된 등가 선형 모델의 상태를 추정할 수 있으므로, 변환시의 연산량도 줄일 수 있다. 이 로서 Grizzle이나 Lee의 방법보다 간단하게 궤환 선형화에 의한 디지틀 상태 제어기를 구현할 수 있었다.

고속전자밸브를 사용한 유압시스템의 안정성 해석에 관한 연구 (A Study on Stability Analysis of Hydraulic System Using High Speed On-Off Valves)

  • 유태재
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권3호
    • /
    • pp.412-420
    • /
    • 2003
  • This study describes the merits of PWM control of hydraulic system using high speed on-off valves. Generally, Electro-hydraulic valves can be classified into two classification: valves which are controlled by analog signal and which are controlled by digital. The former includes hydraulic servo valves and proportional valves which require A/D converters as interface to digital computer and too costly and sensitive to oil contamination because of complexity in structures. The latter includes high speed on-off valves which do not require A/D converters because they are normally operated in a pulse width modulation(PWM) method, and are low in price and robust to oil contamination because of their simple structures. The objectives of this study is to analyze the limit cycle which regularly appear in the position control system using 2/2way high speed on-off valves and to give a criterion for the stability of this system. The nonlinear characteristics of PWM and cylinder friction of this system are described by harmonic linearization and the effects of parameter variations to the system stability are simulated.

비례방향제어밸브에 의해 구동되는 차동 실린더 부하계의 운동제어 (Motion Control of a Single Rod Cylinder-Load System Driven by a Proportional Directional Control Valve)

  • 이민우;조승호
    • 유공압시스템학회:학술대회논문집
    • /
    • 유공압시스템학회 2010년도 춘계학술대회
    • /
    • pp.81-85
    • /
    • 2010
  • This paper deals with the issue of motion control of a single rod cylinder-load system using simple adaptive control (SAC) method. Prior to controller design, the experiment of open-loop response has been performed. Based on it, design parameters of transfer function are obtained. The effect of parallel feedforward compensator has been investigated by computer simulation, suppressing the oscillatory motion. Through experiments it is conformed that the SAC method gives good tracking performance compared to the PD control method.

  • PDF

반능동현가장치용 전자제어식 연속가변댐퍼의 모델링 및 동특성 해석 (Modeling and Dynamic Characteristics Analysis of a Continuously Variable Damper with Electro-Hydraulic Pressure Control Valve)

  • 도홍문;홍경태;홍금식
    • 제어로봇시스템학회논문지
    • /
    • 제8권2호
    • /
    • pp.158-166
    • /
    • 2002
  • A mathematical model and dynamic characteristics ova continuously variable damper for semi-active suspen- sion systems are investigated. After analyzing the geometry of a typical continuously variable damper, mathematical models fur individual components including piston, orifices, spring, and valves are first derived and then the flow equations for extension and compression strokes are investigated. To verify the developed mathematical model, the dynamic response of the model are simulated using MATLAB/SIMULINK and are compared with experimental results. The proposed model can be used not only for mechanical components design but also for control system design.

Modeling and Dynamic Characteristics Analysis of a Continuously Variable Damper with Electro-Hydraulic Pressure Control Valve

  • Moon, Do-Hong;Chul, Sohn-Hyun;Shik, Hong-Keum
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.174.5-174
    • /
    • 2001
  • In this paper, mathematical modeling and dynamic characteristics analysis of a continuously variable damper used for semi-active suspension systems are investigated. After analyzing the geometry of a typical continuously variable damper, models for various components including piston, orifices, spring, and valves are proposed and the flow equations during expansion and compression strokes are derived. To verify the mathematical models developed, the dynamic characteristics of the models are simulated using MATLAB/SIMULINK and are compared with experimental results. It was confirmed that the developed models represent well the actual damper and can be used for control system design.

  • PDF

유동해석을 통한 선박용 디젤엔진(LDCL JWCS)의 3-Way Valve 형상 설계 (Shape Design of the 3-Way Valve used in Marine Diesel Engines (LDCL JWCS) by CFD Analysis)

  • 황기웅;곽효서;김재열;엄태진;김철
    • 대한기계학회논문집A
    • /
    • 제41권11호
    • /
    • pp.1077-1084
    • /
    • 2017
  • 기존의 선박용 디젤 엔진에는 항상 일정한 엔진 부하량을 유지하는 캠 구동장치가 적용되고 있었으나, 최근 환경규제로 인하여 엔진 부하량에 따라 실린더 온도를 개별적으로 제어하는 LDCL(Load dependent cylinder liner) JWCS(Jacket water cooling system)가 적용된 전자유압 제어방식이 개발되었다. 이 시스템에서 3-way 밸브는 실린더의 상부와 하부와의 온도 차이를 줄여 저온부식을 방지하는데, 대부분 수입에 의존하고 있으며 토출유량이 낮다. 이에 본 연구에서는 3-way 밸브 내부 형상 관련 설계인자가 성능(토출 유량 및 온도)에 미치는 영향을 파악하여 밸브의 형상 설계를 수행하였으며, 기존 모델과의 성능 비교를 통해 제안된 밸브의 우수성을 검증하였다.

소형 연근해 어선의 조업 시스템 개선에 관한 연구-I -자동 권양 윈치 시스템의 설계- (Improved Design in Fishing Operation System for Small Inshore and Coastal Fishing Vessels-I -Design of a Automatic Winch System-)

  • 이대재
    • 수산해양기술연구
    • /
    • 제36권1호
    • /
    • pp.12-24
    • /
    • 2000
  • The electro-hydraulic servo winch system built in a automatic tension control equipment was designed with a latent need for an advanced system in fishing operations of the inshore and coastal fishing vessels. In order to keep the constant tension condition of warp under loading, a tension control circuit was added to the servo winch system.The dynamic performance in the open loop behaviour of the designed winch system was investigated and its applicability was tested for various possibilities of load using a load generator especially developed in order to this study.The mechanical characteristics of this system is different from that of a conventional type, that is, the tension, length, line speed and drum revolution can be automatically controlled by the information from various sensors, such as torque, rpm and pressure transducers. from the experiment results, it was verified that the servo winch system has very good output and tracking behaviour for the control input signals in different operating conditions though overshoot of out 8% in the transient characteristics of torque under the load though a overshoot of about 8% in the transient characteristics of torque under the load condition can be observed when the opening of servo valve, adjustable by the input voltage between - 10 V up to 10 V, changed suddenly.Consequently, the improved fishing winch system can be effectively used as the automatic shooting and hauling equipment of low cost for small inshore and coastal fishing vessels which engage in net fishing.

  • PDF

조수간만의 차를 고려한 새로운 하역 시스템의 능동 제어 (Active Control of a New Cargo Handling System Adapted for Time-Varying Tide)

  • 김형석;정달도;최승복;이재욱
    • 대한조선학회논문집
    • /
    • 제36권2호
    • /
    • pp.61-71
    • /
    • 1999
  • 본 연구에서는 조수간만의 차가 큰 항만에 적합한 새로운 하역 시스템을 제안하였다. 새로운 하역 시스템은 기존의 갑문 이용 방식 대신에 일종의 유압 엘리베이터를 사용함으로써 조수간만의 차에 따라 변하는 선박의 높이로 실시간 제어하여 선적 흑은 하역을 하는 방식이다. 한번에 대량의 컨테이너를 처리하기 위해 컨테이너 팔레트 운송타를 도입함으로써 기존 시스템에 비해 시간당 처리능력을 높일 수 있고, 선적 및 하역의 전 과정을 자동화함으로써 작업 효율을 극대화할 수 있도록 하였다. 새로운 하역 시스템의 개념 입증을 위해 소형 하역 시스템 모델을 설계 제작하였다. 제작된 모델은 컨테이너 팔레트 운송차, 플랫폼과 리프트 칼럼의 복합 구조물, 그리고 전용 운반선으로 구성된다. ER(electro-rheological) 밸브-실린더에 의해 구동되는 플랫폼은 조수간만의 차와 과도에 의해 변하는 선박의 높이를 능동적으로 추적 제어하게 된다. 동적 모델성을 통해 플랫폼의 운동 지배 방정식을 도출하였고, 파도 가진으로 인한 선박의 거동 및 조수간만의 차를 모델링하였다. 선적 및 하역의 자동화와 플랫폼의 정확한 위치 제어를 위해 시퀀스 제어기와 PID(proportional-integral-derivative) 위치 제어기가 연계된 제어 시스템을 구성하였다. 컴퓨터 시뮬레이션과 실험을 통해 제안된 하역 시스템의 유용성을 입증하였다.

  • PDF

Energetics of the Heart Model with the Ventricu1ar Assist Device

  • Chung, Chanil-Chung;Lee, Sang-Woo;Han, Dong-Chul;Min, Byoung-Goo
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.43-48
    • /
    • 1996
  • We investigated the energistics of the physiological heart model by comparing predictive indexes of the myocardial oxygen consumption (MOC), such as tension-time index (R), tension-time or force-time inteual (FTI), rate-pressure product (RPP), pressure-work index, and systolic pressure-volume area (PVA) when using the electro-hydraulic left ventricular device (LVAD). We developed the model of LVAD incorporated the closed-loop cardiovascular system with a baroreceptor which can control heart rate and time-varying elastance of left and right ventricles. On considering the benefit of the LVAD, the effects of various operation modes, especially timing of assistance, were evaluated using this coupled computer model. Overall results of the computer simulation shows that our LVAD can unload the ischemic (less contractile) heart by decreasing the MU and increasing coronary flow. Because the pump ejection at the end diastolic phase of the natural heart may increase the afterload of the left ventricle, the control scheme of our LVAD must prohibit ejecting at this time. Since the increment of coronary flow is proportional to the peak aortic pressure after ventricle contraction, the LVAD must eject immediately following the closure of the aortic valve to increase oxygen availability.

  • PDF