• Title/Summary/Keyword: Electricity Supply

Search Result 648, Processing Time 0.026 seconds

An Analysis of Best Practices for Efficient Utility Relocation and an Inquiry into the Applicability of SUE (효율적인 지하지장물 이설을 위한 모범사례분석 및 SUE 적용에 관한 연구)

  • Lee, Seung-Hyun;Baek, Seung-Ho;Tae, Yong-Ho;Ahn, Bang-Ryul;Park, Hyeon-Yong
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.971-976
    • /
    • 2007
  • In the U.S., utility damages or utility delay caused by conflicts during the underground utility relocation is one of the weighty problem in the construction industry. Also, in domestic case, delay and additional cost caused by underground utility(i.e, electricity, communication, gas, water supply and sewerage) relocation has been happened so that there is an increase of claims for responsibility between owners and contractors. However, there is insufficient survey for the recent circumstance of additional cost for delay and design changes caused by utility relocation and shortage of enough research for solving and analyzing of causes and their ripple effect. This research presents a result of the study about the best practices of FHWA(Federal Highway Administration), SHAs(State Highway Agencies) and the utility companies managing utility relocation. Also, it presents the basic concept of SUE(Subsurface Utility Engineering), the most reliable tool of FHWA presented, and investigates the developing status about SUE in Korea. At the end of this paper, this research proposes a practical and more applicable study about the efficient utility relocation focusing on local industry.

  • PDF

The Development of X-ray Unit of Remote Emergency medical System (원격응급시스템에 적합한 X-ray 장치 개발)

  • Cho, Dong-Heon;Koo, Kyung-Wan;Yang, Hae-Sool;Han, Man-Seok;Han, Sang-Ok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.49-54
    • /
    • 2006
  • The X-ray unit developed by this study is to diagnose emergency cases which is too far from a hospital and to classify the patients. We have to use the X-ray in a ambulance or the scene of an accident where we cannot use the AC220 outlet because of the distance from a hospital as well. The X-ray unit developed has a characteristics as follows. First of all, as the unit has a condenser in itself where there is no electric supply, we can use the X-ray inspector in a mountain area or a island. Second, we can detect by digital detector the information taken by X-ray from DC 12[V] electricity and store as a form of file. A control circuit can secure the reliability of the X-ray unit by using the Pic16F84A X-ray and provide various functions. The X-ray unit which suits remote emergency system can be efficiently used for the emergent cases who is too far from a doctor and a hospital or in the situation where it is difficult to diagnose, transcribe and treat simultaneously.

Application of Point Cloud Data for Transmission Power Line Monitoring (송전선 모니터링을 위한 포인트클라우드 데이터 활용)

  • Park, Joon-Kyu;Um, Dae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.224-229
    • /
    • 2018
  • Korea is experiencing a rapid increase in electricity consumption due to rapid economic development, and many power transmission towers are installed to provide smooth power supply. The high-voltage transmission line is mainly made of aluminum stranded wire, and the wire is loosely guided so that some deflection is maintained. The degree of deflection has a great influence on the quality of the construction and the life of the cable. As the time passes, the shrinkage and expansion occur repeatedly due to the weight of the cable and the surrounding environment. Therefore, periodic monitoring is essential for the management of the power transmission line. In this study, the power transmission lines were monitored using 3D laser scanning technology. The data of the power transmission line of the study area was acquired and the point cloud type 3D geospatial information of the transmission line was extracted through data processing. The length of the transmission line and deflection amount were calculated using the 3D geospatial information of the transmission line, and the distance from the surrounding obstacles could be calculated effectively. The result of study shows the utilization of 3D laser scanning technology for transmission line management. Future research will contribute to the efficiency of transmission line management if a transmission line monitoring system using 3D laser scanning technology is developed.

The Effects of Renewable Energy in Agricultural Sector (농업분야 신재생에너지 보급현황 및 파급효과 분석)

  • Park, Jiyun;Kim, Yeonjoong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.224-235
    • /
    • 2019
  • The increase in the amount of energy used in the agricultural sector due to the expansion of agricultural machinery and greenhouse horticulture has caused a range of problems, such as an increase in the cost of input, such as heating costs and greenhouse gas emission. To overcome these problems, this study examined the current status of energy use in greenhouse horticulture as well as the change patterns of non-taxable oil and agricultural electricity, and reviewed the current status of the supply of renewable energy and energy saving facilities for agriculture. This study investigated the area of advanced and renewable energy and energy saving facilities implemented, applied the energy saving ratio of advanced and renewable energy and energy saving facilities, and determined the effects of renewable energy in the agricultural sector, such as increase in production, decrease in heating cost, reduction in Government financial expenditure, reduction in greenhouse gas emission, and oil substitution effect.

Study for Flow Phenomenon in the Circulation Water Pump Chamber using the Flow-3D Model (Flow-3D 모형을 이용한 순환수취수펌프장 내 흐름현상 연구)

  • Ha, Sung-Won;Kim, Tae-Won;Choi, Joo-Hwan;Park, Young-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.580-589
    • /
    • 2019
  • Indonesia has a very short supply of electricity. As a solution to this problem, plans for construction of thermal power plants are increasing. Thermal power plant require the cooling water system to cool the overheated engine and equipment that accompany power generation, and the circulation water pump chamber among the cooling water system are generally designed according to the ANSI (1998) standard. In this study, the design criterion $20^{\circ}$ for the spreading angle of the ANSI (1998) of the layout of the circulating water pump chamber can not be satisfied on the K-coal thermal power plant site condition in Indonesia. Therefore, 3-D numerical model experiment was carried out to obtain a hydraulically stable flow and stable structure. The Flow-3D model was used as numerical model. In order to examine the applicability of the Flow-3D model, the flow study results around the rectangular structure of Rodi (1997) and the numerical analysis results were compared around the rectangular structures. The longitudinal velocity distribution derived from numerical analysis show good agreement. In order to satisfy the design velocity in the circulating water pump chamber, a rectangular baffle favoring velocity reduction was applied. When the approach velocity into the circulating water pump chamber was occurred 1.5 m/s ~ 2.5 m/s, the angle of the separation flow on the baffle was occurred about $15^{\circ}{\sim}20^{\circ}$. By placing the baffle below the separation flow angle downstream, the design velocity of less than 0.5 m/s was satisfied at inlet bay.

Scenario-based Vulnerability Assessment of Hydroelectric Power Plant (시나리오 기반 수력플랜트 설비의 취약성 평가)

  • Nam, Myeong Jun;Lee, Jae Young;Jung, Woo Young
    • Journal of Korean Society of Disaster and Security
    • /
    • v.14 no.1
    • /
    • pp.9-21
    • /
    • 2021
  • Recently, the importance of eco-friendly power generation facility using renewable energy has newly appeared. Hydropower plant is a very important source of electricity generation and supply which is very important to secure safety because it is commonly connected with multi facility and operated on a large scale. In this study, a scenario-based analysis method was suggested to assess vulnerability of a penstock system caused by water hammer commonly occurred in the operation of hydropower plants. A hypothetical hydropower plant was used to demonstrate the applicability of a transient analysis model. In order to verify reliability of the model, the prediction of pressure behaviors were compared with the results of commercial model (SIMSEN) and measured data, then a real hydroelectric power plant was applied to develop all potential water hammer scenarios during the actual operation. The scenario-based simulation and vulnerability assessment for water hammer in the penstock system were performed with internal and external load conditions. The simulation results indicated that the vulnerability of a penstock system was varied with the operating conditions of hydropower facilities and significantly affected by load combination consisting of different load scenarios. The proposed numerical method could be an useful tool for the vulnerabilityty assessment of the hydropower plants due to water hammer.

Analyzing The Economic Impact of The Fire Risk Reduction at Regional Level in Goyang City (지역단위 화재 위험도 저감의 고양시 경제적 파급효과 분석)

  • Son, Minsu;Cho, Dongin;Park, Chang Keun;Ko, Hyun A;Jung, Seunghyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.685-693
    • /
    • 2021
  • This study examined the fire risk of the region in Goyang City using the spatial information data of buildings. The economic damage by industry was assessed according to the probability of fire risk. The study area was confined to Goyang-si, Gyeonggi-do, and the same fire risk reduction rate was applied to each region for the convenience of analysis. The possibility of fire was derived based on the buildings' density and usage in the area by National GIS building-integrated information standard data. The calculation of economic damage by industry in Goyang City due to the fire risk was calculated by combining the Goyang-si industry-related model produced by matching with 30 industrial categories in Input-Output Statistics of Korea Bank and 20 industrial categories in the Goyang-si business survey and the possibility of fire. The basic scenario of production impossibility during six months and business loss due to fire was established and analyzed based on the supply model. The analysis showed that Ilsan-dong-gu, Ilsan-seo-gu, and Deokyang-gu suffered the most economic damage. The "electricity, gas, steam, and water business" showed the greatest loss by industry.

An Experimental Study on the Applicability of UAV for the Analysis of Factors Influencing Rural Environment - Focusing on Photovoltaic Facilities and Vacant House in Galsan-Myeon, Hongseong-gun - (농촌 공간 환경영향요인 분석을 위한 무인항공기 적용 가능성에 관한 실험적 연구 - 홍성군 갈산면의 태양광 발전시설과 빈집을 중심으로 -)

  • An, Phil-Gyun;Eom, Seong-Jun;Kim, Su-Yeon;Kim, Young-Gyun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.24 no.1
    • /
    • pp.9-17
    • /
    • 2022
  • Rural spaces are increasingly valuable as areas for introducing renewable energy infrastructure to achieve carbon neutrality. Rural areas are the living grounds of rural residents, and the balance of conservation and development for rural areas is important for the introduction of reasonable facilities. In order to maintain a balance between development and preservation and to introduce reasonable renewable energy facilities, it is necessary to develop a current status survey and an effective survey method to utilize a space capable of introducing renewable energy facilities such as idle land and vacant houses. Therefore, this study was conducted to verify the readability using an unmanned aerial vehicle, and the main results are as follows. The detection of photovoltaic power generation facilities using unmanned aerial vehicles was effective in analyzing the location and area of photovoltaic panels located on the roofs of buildings, and it was possible to calculate the expected power generation by region through the area calculation of photovoltaic panels. The vacant house detection can be used to select an investigation target for an vacant house condition survey as it can identify damage to buildings that are expected to be empty houses, management status, and electricity supply facilities through aerial photos. It is judged that the unmanned aerial vehicle detection capability can be utilized as a method to improve the efficiency of investigation and supplement the data related to solar power generation facilities and vacant houses provided by public institutions. Although this study detected the status of solar power generation facilities and vacant houses through high-resolution aerial image analysis, as a follow-up study, automatic measurement methods using the temperature difference of solar power generation facilities and general characteristics of vacant houses that can be read from the air were investigated. If the deriving research is carried out, it is judged that it will be possible to contribute to the improvement of the accuracy of the detection result using the unmanned aerial vehicle and the expansion of the application range.

Proposal on Active Self Charging and Operation of Autonomous Vehicle Using Solar Energy (태양광을 이용한 자율주행 자동차의 능동적 자가 충전 및 운행 제안)

  • Hur, Hyun-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.9
    • /
    • pp.85-94
    • /
    • 2022
  • In modern society, environmental and energy problems have caused to replace cars with environment friendly energy. Vehicles with internal combustion engine which use petroleum are one of the factors that influence global pollution due to environment problems such as fine dust and ozone layer destruction. In addition use of energies for automobile making resources to become depleted. To solve this limited oil energy problem by using other energy sources. To the problem using electric energy and green energy as alternative for a solution. Among environment friendly energies this paper studies the possibility of drive service for autonomous vehicles that self-charges using only solar energy and whether they can be used as pollution free and alternative energy for automobiles. Studies was researched based on published literature review, data from ministry of transportation and automobile companies. Also case of electric vehicle and prototype automobile using only solar energy and the theory of near future technologies. Many automakers are using electric cars as alternative energy. Also making efforts to use solar energy as an substitute energy source and as a way to supplement electricity. Results show that there is a potential on operating autonomous vehicle using only solar energy. Furthermore, it will be possible to use automobiles actively, also use and supply solar energy. This paper suggest the possibility of contributing to the future of the automotive industry.

Brief Review on Exposure Characteristics, Monitoring Instruments and Threshold Limit Values for Extremely Low Frequency-Magnetic Field (ELF-MF) (직업성 극저주파 자기장 노출평가와 노출 기준에 대한 쟁점 고찰)

  • Dong-Uk, Park;Seunghee, Lee;Kyung Ehi, Zoh
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.4
    • /
    • pp.381-392
    • /
    • 2022
  • Objectives: Objective of this study is to review briefly exposure characteristics, monitoring instruments and threshold limit values for extremely low frequency-magnetic field (ELF-MF) methods. This study was undertaken through brief literature review. We performed a literature search in PubMed to identify ELF-MF studies conducted in workplaces. Initial search keywords such as 'extremely low frequency-magnetic field (ELF-MF)' and 'electromagnetic fields (EMF)' combined or singly. We limited our review to occupational rather than general nonworkplace environmental exposures. Methods: The contents we reviewed: key industry and occupations generating ELF-MF, several direct-reading instruments monitoring ELF-MF and threshold limit values (TLV) preventing health effects may be caused by the exposure to ELF-MF. Results: The industries related to the generation and supply of electricity, electrolytic installations, welding, and induction heating and more were regarded as high ELF-MF exposure industries. All jobs handling or employed performed in power cable lines, electrical wiring, and electrical equipment are found to be exposed to ELF-MF. Threshold or ceiling limit, 1,000 µT, is established to prevent acute effects of exposure to low-frequency EMFs on the nervous system: the direct stimulation of nerve and muscle tissues and the induction of retinal phosphenes. The International Agency for Research on Cancer (IARC) has classified ELF-MF as possibly carcinogenic to humans chiefly based on epidemiological studies on childhood leukemia. However, a causal relationship between magnetic fields and several types of cancer including childhood leukemia has not been established nor has any other long-term effects. Risk management using precautionary measures, has been initiated by the US and EU to prevent chronic health effects related to ELF-MF exposure in workplaces. Conclusion: This study recommends the implementation of various measures such as theestablishment of occupational exposure limit values for ELF-MF and precautionary principle to prevent potential chronic occupational health effects may be caused by ELF-MF in Korea.