• Title/Summary/Keyword: Electricity Line

Search Result 216, Processing Time 0.035 seconds

Fuzzy Estimation for Fault Location

  • Tipsuwanporn, V.;Tuppadung, Y.;Suesut, T.;Rukkaphan, S.;Junkrob, N.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.453-453
    • /
    • 2000
  • This paper presented Fuzzy logic application to Electrical power system analysis for fault location estimation in distribution lines and apply the Power system theory to be fuzzy logic database. The case study referred to the Overhead distribution line of the Provincial Electricity Authority (PEA.), Thailand which mostly the distribution line of PEA. are Radial schemes. These benefits include reduced outage time, help in locating momentary faults, enhance safety to the line crews and provide notification of an outage without receiving calls from the consumer, Which these benefits also increase Reliability, Stability and Efficiency.

  • PDF

An Approach To Alloctating Transmission System Reliabity Cost (송전계통의 신뢰도 비용 산정 방안에 대한 연구)

  • Chung, Koo-Hyung;Shin, Young-Kyun;Kim, Bal-Ho H.;Im, Sung-Hwang
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.515-517
    • /
    • 2001
  • The efficient and rational transmission rate system is one of the crucial factors in creation of fair and competitive electricity market. Transmission charge can be largely categorized into the line usage charge, system reliability maintenance charge, access charge and others. Therefore, transmission rate structure should be able to reflect these cost components reasonably. This Paper suggests an approach that could be used for the reasonable calcuation of transmission reliability costs with reflection of line sensitivity and line outage rate.

  • PDF

Numerical analysis of electromagnetic fields in the trailer car of high speed train by transmission line matrix method (TLM 방법을 이용한 고속열차내의 객차 내부의 전자기장 해석)

  • Han, In-Su;Lee, Tae-Hyung;Park, Choon-Soo;Kim, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.403-406
    • /
    • 2009
  • Recently, electricity is essential for human lives. Modem people take cultural benefits due to the development of the electric power system and the spread of the high tech-electric appliances, the cell phones, and etc. However, the electromagnetic field problems become prominent figures owing to the fault of the communication devices around the power line and the biological effect, and etc. In this paper, we introduce the simple electromagnetic field calculation based on the transmission line matrix method, prior to the analysis about the influence of electromagnetic field. Simulation object is the inner part of the trailer car in the high speed train. Unlike the existing paper we submitted, we analyze not only the magnetic field but the electric field in the inner part of the trailer car which makes up the high speed train.

  • PDF

A Robust Fault Location Algorithm for Single Line-to-ground Fault in Double-circuit Transmission Systems

  • Zhang, Wen-Hao;Rosadi, Umar;Choi, Myeon-Song;Lee, Seung-Jae;Lim, Il-Hyung
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • This paper proposes an enhanced noise robust algorithm for fault location on double-circuit transmission line for the case of single line-to-ground (SLG) fault, which uses distributed parameter line model that also considers the mutual coupling effect. The proposed algorithm requires the voltages and currents from single-terminal data only and does not require adjacent circuit current data. The fault distance can be simply determined by solving a second-order polynomial equation, which is achieved directly through the analysis of the circuit. The algorithm, which employs the faulted phase network and zero-sequence network with source impedance involved, effectively eliminates the effect of load flow and fault resistance on the accuracy of fault location. The proposed algorithm is tested using MATLAB/Simulink under different fault locations and shows high accuracy. The uncertainty of source impedance and the measurement errors are also included in the simulation and shows that the algorithm has high robustness.

Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line (22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석)

  • Kim, Jeom-Sik;Kim, Do-Young;Park, Yong-Beom
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.

Psophometeric Noise Voltage of Telecommunication Lines and Test methods (통신회선의 잡음전압 기준 및 측정법)

  • Hwang, Jong-Sun;Kim, Yeong-Min;Lee, Kyoung-Wook;Kim, Jae-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.617-620
    • /
    • 2001
  • The protection of communication lines against harmful effects from electricity lines is very important with the rapid development of communications network. This paper is introduced the reference of noise voltage and the test methods of foreign countries. Further we will also present study measurement equipment for telecommunications noise voltage and circuit noise phenomenon.

  • PDF

Psophometeric Noise Voltage of Telecommunication Lines and Test methods (통신회선의 잡음전압 기준 및 측정법)

  • 황종선;김영민;이경욱;김재준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.617-620
    • /
    • 2001
  • The protection of communication lines against harmful effects from electricity lines is very important with the rapid development of communications network. This paper is introduced the reference of noise voltage and the test methods of foreign coutnreis. Further we will also present study measurement equipment for telecommunications noise voltage and circuit noise phenomenon.

  • PDF

Coordinated Wide-Area Regulation of Transmission System for Voltage Profile Improvement and Power Loss Reduction

  • Asadzadeh, Babak;Golshannavaz, Sajjad
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.5
    • /
    • pp.279-286
    • /
    • 2017
  • In this paper, an optimal approach for the wide-area regulation of control devices in a transmission network is proposed. In order to realize an improved voltage profile and reduced power loss, existing devices such as tap-changing transformers, synchronous machines, and capacitor banks should be controlled in a coordinated and on-line manner. It is well-understood that phasor measurement units in transmission substations allow the system operators to access the on-line loading and operation status of the network. Accordingly, this study proposes efficient software applications that can be employed in area operation centers. Thus, the implanted control devices can be regulated in an on-line and wide-area coordinated approach. In this process, efficient objective functions are devised for both voltage profile improvement and power loss reduction. Subsequently, sensitivity analysis is carried out to determine the best weighting factors for these objectives. Extensive numerical studies are conducted on an IEEE 14-bus test system and a real-world system named the Azarbayjan Regional Transmission Network. The obtained results are discussed in detail to highlight the promising improvements.

New Technical Trend of Inspection and Test of Transmission Line (가공송전선로 점검 및 진단기술에 대한 해외기술동향)

  • Shin, Tai-Woo;Jang, Suk-Han;Kim, Mu-Soo;Min, Byeong-Wook;Choi, Jin-Sung;Yoon, Gen-Hwa;Gwon, Yeon-Han;Jung, Du-Ok;Bang, Hang-Kwon;Choi, Han-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.315-317
    • /
    • 2008
  • Recently, a new construction of transmission line has been through quite hard situation due to demands for a new construction of transmission line have been saturated in south korea and also difficulties of purchasing the routes. In addition, the demands for electricity have been decreased in all of advanced countries of the world due to slowdown of the rate of economic growth. So they are trying to find a way to utilize a existing transmission line by extending the durable period. Therefore this is necessary to apply an applicable technology on domestic markets such as inspection, examination, maintenance of existing transmission lines by introducing advanced countries's example which shall be based on Japan's electric power companies.

  • PDF

Development and application of on-line lightning information service (온라인(On-line) 낙뢰정보 활용 서비스의 개발과 활용)

  • Kwak, J.S.;Woo, J.W.;Kang, Y.W.;Koo, G.S.;Choi, H.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.696-698
    • /
    • 2007
  • As overhead transmission lines are exposed to the outdoor weather, lightning induced fault accounts for about 66% of faults in transmission lines. The lightning may cause the damage of power system apparatus or the shut down of electricity. Not only in order to decrease the damage of the power system itself but also to ensure the reliable power supply, an appropriate insulation design based on the long-term lightning statistics is required. Meanwhile, real time information of lightning might be more useful to quickly locate the point of lightning induced fault in the line, leading to minimization of the adverse effects derived from the fault. Korea Electric Power Corporation has been providing an on-line lightning information service, named as KLDNet, since 2006 in order to meet the need inside our company. This paper describes the development and application of the information system.

  • PDF