• 제목/요약/키워드: Electricity Demand Analysis

검색결과 258건 처리시간 0.028초

Analysis of Power System Dynamic Security Due to Operation of 345kv CLR (345kv한류리액터 운전에 따른 전력계통 동적안전도 해석)

  • Lee Baek Seok;Kang Dae Eon;Lee Kang Wan
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.24-26
    • /
    • 2004
  • The growing demand for electricity has result in a corresponding increase in power generated and transmitted. As the increase in installed capacity of power system, the fault currents of 345kv system will be increased beyond the interrupting duty of the circuit breakers. The current limiting reactors are used to limit the fault current. The paper presents the result of the transient stability and voltage stability due to install 345kV current limiting reactor to suppress the fault currents.

  • PDF

Analysis of Capacity Factors and Capacity Credits for Wind Turbines Installed in Korea (국내 풍력발전 설비의 이용률과 용량크레딧 분석)

  • Paik, Chunhyun
    • Journal of the Korean Solar Energy Society
    • /
    • 제39권4호
    • /
    • pp.79-91
    • /
    • 2019
  • The capacity credit (CC) is a key metric for mid- to long-term power system capacity planning. The purpose of this study is to estimate the CCs of domestic wind turbines. Based on hourly capacity factor (CF) data during the seven years from 2011 to 2017, the new so-called probabilistic CF scheme is introduced to effectively reflect the variability of CFs on CC estimation. The CCs are then estimated through the CF-based method and the ELCC (Effective Load Carrying Capability) method reflecting the probabilistic CF scheme, and the results are compared. The results show that the CC value 0.019 for domestic wind turbines proposed in the $8^{th}$ Basic Plan for Electricity Supply and Demand corresponds to the CC with a confidence level slightly lower than 95%.

Novel System Modeling and Design by using Eclectic Vehicle Charging Infrastructure based on Data-centric Analysis (전기차 충전인프라 및 데이터 연계 분석에 의한 시스템 모델링 및 실증 설계)

  • Kim, Hangsub;Park, Homin;Jeong, Taikyeong;Lee, Woongjae
    • Journal of Internet Computing and Services
    • /
    • 제20권2호
    • /
    • pp.51-59
    • /
    • 2019
  • In this paper, we analyzed the relationship between charging operation system and electricity charges connected with charging infrastructure among data of many demonstration projects focused on electric vehicles recently. At this point in time, due to the rapid increase in demand for the electric charging infrastructure that will take place in the future, we can prepare for an upcoming era in the sense of forecasting the demand value. At the same time, demonstrating and modeling optimized system modeling centering on sites is a prerequisite. The modeling based on the existing small - scale simulation and the design of the operating system are based on the data linkage analysis. In this paper, we implemented a new optimized system modeling and introduced it as a standard format to analyze time - dependent time - divisional data for each vehicle and user in each point and node. In order to verify the efficiency of the optimization based on the data linkage analysis for the actual implemented electric car charging infrastructure and operation system.

Heat balance analysis for process heat and hydrogen generation in VHTR (공정열 및 수소생산을 위한 초고온가스로 열평형 분석)

  • Park, Soyoung;Heo, Gyunyoung;Yoo, YeonJae;Lee, SangIL
    • Journal of Energy Engineering
    • /
    • 제25권4호
    • /
    • pp.85-92
    • /
    • 2016
  • Since the power density of the VHTR(Very High Temperature Reactor) is lower, there is less possibility of core melt. VHTR has no risk of explosion caused by hydrogen generation when the loss of coolant accident occurs, which is another advantage. Along with safety benefit, it can be used as a process heat supplier near demand facilities because coolant temperature is very high enough to be used for industrial purpose. In this paper, we designed the primary system using VHTR and the secondary system providing electricity and process heat. Based on that 350 MW thermal reactor proposed by NGNP(Next Generation Nuclear Part), we developed conceptual model that the IHX(Intermediate Heat Exchanger) loop transports 300 MW thermal energy to the secondary system. In addition, we analyzed thermodynamic behavior and performed the efficiency analysis and optimization study depending on major parameters.

An Analysis of Interfuel Substitution of Energy Demand in Korean Manufacturing (한국 제조업부문의 연료용 에너지원간의 대체성 분석)

  • Park, Changsuh;Na, In-Gang
    • Environmental and Resource Economics Review
    • /
    • 제13권4호
    • /
    • pp.593-619
    • /
    • 2004
  • This study analyzes the interfuel substitution of energy demand in Korean manufacturing sector using static and dynamic linear logit models. For the period of 1981~2002, this study uses petroleum, electricity, natural gas and coal as energy sources. According to the empirical results, firstly, the own-price elasticity of coal has been increased steadily even though its elasticity is smallest compared with those of other energy sources. On the other hand, price elasticity of natural gas is largest, but its value has been decreased after 1997. Price elasticities of petroleum and electricity are very stable over the sample period. One of the main features in trends of interfuel substitution is as follows. Substitution effect of a change in price of natural gas on both petroleum and coal has been increased especially after 1997. The implication of the empirical results is summarized as follows: First, the fact of inelastic own-price elasticity of petroleum implies that the dependency of Korean manufacturing sector on petroleum and coal will be persistent even in a sharp fluctuation of petroleum price. Second, the effects of price increase in natural gas on demand for petroleum and coal are very significant. Thus, price decline of natural gas rather than price declines of coal and petroleum could be more effective as an energy price policy for the reduction of $CO_2$ emission. The assessment on this implication will remain for future researches.

  • PDF

Economic Feasibility of Common Utility Tunnel based on Cost-Benefit Analysis (비용편익 분석에 기초한 공동구의 경제적 타당성 평가)

  • Kang, Yeong Ku;Choi, Ik Chang
    • Journal of the Korean Society of Safety
    • /
    • 제30권5호
    • /
    • pp.29-36
    • /
    • 2015
  • Common utility tunnel is essential to the daily lives of people underground utilities (electricity, gas and supply facilities such as water, communication facilities, sewer facilities, etc.) to improve the appearance by co-acceptance and disaster prevention, important for the conservation of the city's population was concentrated road construction the city-based facilities. There is recognition of the importance of the various supply treatment facilities in common utility tunnel as infrastructure to accommodate joint according to the city expanded, the demand for infrastructure. In this paper, a cost-benefit analysis using a one-time occurrence, without simply relying on cost or current cost, project manager for the city-dimensional feasibility study conducted, the user level of the maintenance costs and user costs, including social costs items from various angles can be investigated and proposed a mechanism of economic feasibility common utility tunnel. Evaluation of the proposed technique is cost-benefit and cost caused by installing common utility tunnel the existing pipeline area - was investigated by the benefit analysis, extended and repeated common utility tunnel installation depends much affected by the excavation, so users of reducing the number of repeat excavation convenience can be seen that this occurs.

A Case Study on Investment Evaluation of Hadong T/P(Thermal Power) Port

  • Kim, Myoung-Hee;Lee, Ki-Hwan;Jang, Ji-Tae
    • Journal of Navigation and Port Research
    • /
    • 제39권2호
    • /
    • pp.99-105
    • /
    • 2015
  • Until recently, thermal power plants have used high-rank coals to generate electricity. The switched to low-rank coals, primarily because of the rising coal price and the advancement of combustion technology. Therefore the thermal power plants need more fuels aspect of quantity and they are going to build extra infrastructure to deal with the increased fuel demand in their specialized ports. This paper introduces the process of the economic analysis as a case study for Hadong T/P(Thermal Power) Port. This study also evaluates investment for mew projects in ports. We analyze the costs and benefits of the port investment project using various information. And then we conduct the economic analysis using NPV(net present value), B/C ratio and IRR grounded in a financial theory. Out result of the economic feasibility shows that the new project of constructing a third berth in Hadong T/P Port has positive economic value. Additionally, this study conducts the sensitivity analysis of the major variables like cost, benefit and discount rate.

Analysis of GHG Reduction Scenarios on Building using the LEAP Model - Seoul Main Customs Building Demonstration Project - (LEAP 모형을 이용한 건축물의 온실가스 감축 시나리오 분석 - 서울세관건물 그린리모델링 시범사업을 중심으로 -)

  • Yoon, Young Joong;Kim, Min Wook;Han, Jun;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • 제7권3호
    • /
    • pp.341-349
    • /
    • 2016
  • This study is intended to set a greenhouse gas emission scenario based on green remodeling pilot project (Annex building of Seoul Customs Office) using LEAP model, a long-term energy plan analysis model, to calculate the energy saving and greenhouse gas emission till year 2035 as well as to analyze the effect of electric power saving cost. Total 4 scenarios were made, Baseline scenario, assuming the past trend is to be maintained in the future, green remodeling scenario, reflecting actual green remodeling project of Seoul Customs Office, behavior improvement and renewable energy supply, and Total scenario. According to the analysis result, the energy demand in 2035 of Baseline scenario was 6.1% decreased from base year 2013, that of green remodeling scenario was 17.5%, that of behavior improvement and renewable energy supply scenario was 21.1% and that of total scenario was 27.3%. The greenhouse emission of base year 2013 was $878.2tCO_2eq$, and it was expected $826.3tCO_2eq$, approx. 5.9% reduced, in 2035 by Baseline scenario. the cumulative greenhouse gas emission saving of the analyzing period were $-26.5tCO_2eq$ by green remodeling scenario, $2.8k\;tCO_2eq$ by behavior improvement and renewable energy supply scenario, and $2.0k\;tCO_2eq$ by total scenario. In addition the effect of electricity saving cost through energy saving has been estimated, and it was approx. 634 million won by green remodeling scenario and appro. 726 million won by behavior improvement and renewable energy supply scenario. So it is analyzed that of behavior improvement and renewable energy supply scenario would be approx. 12.7% higher than that of green remodeling scenario.

Extended TAM Analysis of a Residential DR Pilot Program (확장된 기술수용모델을 이용한 가정용 에너지 수요반응 프로그램 실증분석)

  • Jung, Euna;Lee, Kyungeun;Kim, Hwayoung;Jeong, Sora;Lee, Hyoseop;Suh, Bongwon;Rhee, Wonjong
    • Journal of the HCI Society of Korea
    • /
    • 제12권4호
    • /
    • pp.65-73
    • /
    • 2017
  • While electricity demand is generally increasing, stably controlling supply is becoming a serious challenge because renewable energies are becoming popular and often their productions are dependent on the weather. The 'demand response' programs can be used to complement the problems of renewable energies, and therefore their role is becoming increasingly important. This study provides an analysis of a demand response pilot that was conducted in Korea. The study first focused on questionnaire surveys and in-depth interviews, and the data was used to perform a Technology Acceptance Model (TAM) analysis. The goal of the pilot was to have the residential users reduce their power consumptions when an energy reduction mission is issued during peak load hours. The experimental subjects consisted of two groups with different characteristics. Subjects in group A obtained smart meters as an optional function of IoT platform service provided by a mobile service company, and received a charge deduction as their compensation. Subjects in group B either voluntarily purchased smart meters as individuals or received them by participating in an energy self-sufficient village program that was run by a local government, and were entitled to a donation as their compensation. With the analysis, group A was found to fit the extended technology acceptance model that includes perceived playfulness in addition to perceived ease of use and perceived usefulness. On the contrary, group B failed to fit the model well, but perceived usefulness was found to be relatively more important compared to group A. The results indicate that the residential energy groups' behavior changes are dependent on each group's characteristics, and group-specific DR design should be considered to improve the effectiveness of DR.

A Simulation based Study on the Economical Operating Strategies for a Residential Fuel Cell System (시뮬레이션 기반 가정용 연료전지 시스템의 경제적 운전전략에 관한 연구)

  • Hwang, Su-Young;Kim, Min-Jin;Lee, Jin-Ho;Lee, Won-Yong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • 제20권2호
    • /
    • pp.104-115
    • /
    • 2009
  • In case of residential fuel cell system, it is significant to stably supply heat and power to a house with high efficiency and low cost for the successful commercialization. In this paper, the control strategy analysis has been performed to minimize the total cost including capital and operating cost of the residential fuel cell system. The proposed analysis methodology is based on the simulator including the efficiency models as well as the cost data for fuel cell components. The load control strategy is the key factor to decide the system efficiency and thus the cost analysis is performed when the fuel cell system is operated for several different load control logics. Additionally, annual efficiency of the system based on the seasonal load data is calculated since system efficiency is changeable according to the electric and heat demand change. As a result, the hybrid load control combined electricity oriented control and heat oriented control has the most economical operation.