• 제목/요약/키워드: Electrical tree

검색결과 589건 처리시간 0.025초

가지형 트리의 열화진단을 위한 방전통계량에 관한 연구 (A Study on Discharge Statistics Quantities for Deterioration Diagnosis of Branch-type Tree)

  • 신성권;김경민;김탁용;이덕진;박창옥;김재환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2345-2348
    • /
    • 1999
  • Existing $\psi$-AEA-t (phase-AEA-time) characteristic in polymer materials for power cable is good in general deterioration characteristic according to time variation, but it is difficult to clearly distinguish from deterioration state and diagnosis of deterioration is not enough to some extent. This paper is interpreted AE discharge statistics quantities measuring phase-amplitude variation of acoustic emission characteristic obtained from treeing breakdown experiment. Besides it can know useful discharge statistics quantities (AE average inception phase/amplitude, AE average maximum phase/amplitude) about so many for diagnosis of treeing deterioration.

  • PDF

고체절연체 계면에서 부분방전 패턴의 열화에 따른 변화특성 (The Characteristics of PD Patterns due to the Aging at the Interface between Solid Insulators)

  • 이우영;선종호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1725-1727
    • /
    • 1998
  • In this paper the patterns of partial discharges(PD) occurred from some defects at the interface of cable joints as the function of the phase of the applied voltage were investigated in order to discern the kind of a defect. The results obtained in this study show that it is possible to distinguish the PD patterns between the void discharges and the treeing or tracking discharges which were occured at the cable joint interface. While the state of defect transfers from a void discharge into a tree or tracking discharge with a aging time, the skewness for both half of the applied voltage cycle is observed to go to the negative value.

  • PDF

계면특성이 전력케이블 열화에 미치는 영향 (Interfacial Effects on the Aging of Power Cables)

  • 한재홍;이동영;김상준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1393-1395
    • /
    • 1997
  • In order to investigate the interfacial effects on the aging of power cables, we analyzed recently failed cables using characterization techniques. In this study, some cables showed a convolution which can cause the concentration of electric field and carbonized impurities at the surface of insulation. Also there is a relation between the degree of cross- linking and volume resistivity. From the hot oil test, the sites of water tree and void coincided with each other.

  • PDF

냉각조건변화에 따른 폴리에틸렌의 트리잉 파괴 예지에 관한 연구 (A Study on the Treeing Breakdown Expectation due to Variation of Quenching in Polyethylene)

  • 박세화;심종탁;김성홍;백관현;박재준;김재환;박창옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1580-1582
    • /
    • 1994
  • In this study, when AC voltage is applied to block type treeing specimen which is fabricated with polyethylene which dielectric characteristics is excellent, from initial tree to final breakdown, Using acoustic emission method. we take statistically on parameter, which is skewness. We experimented on quenching condition and illustrated skewness locus plane so that studied interrelation of life expectation and parameter.

  • PDF

초고압 XLPE 케이블 금속 차폐층 고찰 (A study or Metallic sheath for Extra-high voltage XLPE cable)

  • 최창수;이갑중;정무영;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1652-1654
    • /
    • 1994
  • The Extra-high voltage XLPE cable is characterized by low transmission loss, large capacity, and high reliability. Conventionally, for XLPE cables of l54kV and above, aluminium sheath was used to be moisture barrier (thus preventing water tree deterioration of the insulation) and to protect cable core from physical stresses. However, as transmission capacity of the cable increases, so does the cable diameter and the corresponding aluminium sheath outer diameter and thickness. As a result, eddy-current loss in the sheath is increased, limiting the maximum current capacity of the cable itself. As an alternative to aluminium sheath, we have adopted stainless steel sheath with non-magnetic properties and a large resistivity, The new XLPE cable with stainless-steel sheath (CSZV cable) has drastically reduced eddy-current loss in the sheath.

  • PDF

WiBEEM Addressing Scheme Based on NAA Algorithm for High-Speed Mobility of USN Devices

  • Jeon, Ho-In
    • Journal of Ubiquitous Convergence Technology
    • /
    • 제1권1호
    • /
    • pp.42-46
    • /
    • 2007
  • In this paper, we proposed an efficient short address allocation mechanism for WiBEEM devices using NAA(Next Address Available) algorithm. The proposed addressing mechanism is based upon the NAA information that is delivered over the beacons every time it is transmitted at the beginning of each super-frame. The NAA-based addressing mechanism is not a systematic way of allocating short addresses to newly joining devices and thus tree-routing cannot be supported. However, it has great advantages when U-City core services including U-Parking Lot System or ATIS(Advanced Traveler Information System) services that require high-speed mobility are considered. Moreover, the proposed addressing mechanism can provide significant expandability of the wireless network to various applications and fast device discovery.

  • PDF

에러가 있는 환경에서 RFID 태그 충돌을 해결하기 위한 DFSA와 이진트리 프로토롤의 성능 비료 및 분석 (Performance Comparison and Analysis of DFSA and Binary Tree Protocol for RFID Tag Anti-Collision in Error-Prone Environment)

  • 엄준봉;이태진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.493-494
    • /
    • 2007
  • RFID (Radio Frequency IDentification) 시스템에서 수동 태그의 낮은 전송 파워 때문에 리더는 태그와의 통신시 많은 에러를 경험하게 된다. 이것은 리더가 태그의 정보를 빠르고 정확하게 인식하는 것을 어렵게 만든다. 따라서, 이러한 문제를 해결하기 위해 에러에 강한 알고리즘을 개발하고 적용할 필요가 있다. 리더가 태그의 정보를 인식하기 위해 사용하는 대표적인 프로토콜에는 ALOHA 기반의 DFSA (Dynamic Framed-Slotted ALOHA) 프로토콜과 트리 기반의 이진트리 프로토콜이 있다. 기존의 두 프로토콜 중 DFSA는 에러가 없을 때 이진트리 보다 성능이 우수하나, 에러가 존재할 때, 이진트리 보다 약 35% 정도 에러의 영향을 많이 받는 성질을 보인다. 본 논문에서는 에러가 있는 환경과 없는 환경에서의 DFSA와 이진트리 프로토콜의 성능을 분석하고, 시뮬레이션을 이용하여 이 논문에서의 성능 분석 방법이 타당함을 증명한다. 그리고 에러가 많은 환경에서는, 빠른 RFID 태그 인식을 위해 DFSA 프로토콜보다 이진트리 프로토콜을 사용할 것을 제안한다.

  • PDF

아날로그 달팽이관 칩을 위한 다중필터의 설계 (Design of Multiple Filter-Banks for Analog Cochlear Chip)

  • 이광;우영진;김재협;조규형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3142-3144
    • /
    • 2000
  • 청각시스템의 저전력 및 가격의 저렴화를 위해 달팽이관의 BM(Basilar Membrain)모델을 아날로그 VLSI 마이크로 파워 공정으로 구현하고 있다. Lyon and Mead는 실리론 공정으로 달팽이관 모델을 효과적으로 구현하였다. 이는 단순 직렬 연결된 구조로 각 채널의 지연시간의 차이로 인해 인식율이 떨어질 수 있다. 본 논문에서는 소리의 주파수 정보 추출기능을 하는 직렬 연결된 트리구조(TSBF:Tree-structured Cascaded Bandpass Filter)의 16채널의 아날로그 중간대역통과 필터회로를 CMOS VLSI 공정을 이용하여 설계하였다. 직렬 연결된 저대역통과필터와 고대역통과필터로 각 채널의 중간대역통과 필터를 구현하였다. 이러한 구조에서는 각 채널의 지연시간이 동일하므로 인식율을 높일 수 있다. 그리고 고대역통과필터를 1-poly 디지털 공정으로 구현 가능하고 기생 캐패시터의 영향을 적게 받는 구조로 설계하였다.

  • PDF

이족 로봇을 위한 동적 보행 해석 (Dynamic Walking Analysis for Biped Robot)

  • 박인규;김진걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2804-2807
    • /
    • 2000
  • This paper suggests a method of the forward dynamic analysis for the computer simulation on the analysis of the dynamic behavior for biped walking robot. The equations f motion of the system or the simulation are constructed by using the Method of the multibody dynamics which is powerful method for modeling of the complex biped system. For the simplicity of simulation, we consider that the sole of the contacting foot is affected by the reaction forces for tree structure system topology instead of the addition or deletion of the kinematic constraints. The ground reaction forces can be modeled using the simple spring and damper model at the three contacting points on the sole of the foot. For minimizing the errors of numerical integration, the number of equations of motion is minimized by adding the driving constraints or a controller instead of the direct driving torques.

  • PDF

지중배전선로의 고장전류 크기 및 보호협조분석 (Ananalzing fault current and Protective coordination in the underground line)

  • 조남훈;하복남;이중호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.932-934
    • /
    • 1998
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the past, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. So we developed KODAS(Korea Distribution Automation System) with successful and had fieid-testing of Distribution Automation System in last three years at Kang-dong Branch Office. In performing the project, KEPRI has gained valuable experience, through dealing with many difficult problem. This paper is depicted about the circuit breaker coordination problems in the Underground for the Distribution Automation Feeder.

  • PDF