• Title/Summary/Keyword: Electrical test

Search Result 7,379, Processing Time 0.05 seconds

A Study On Radiation Detection Using CMOS Image Sensor (CMOS 이미지 센서를 사용한 방사선 측정에 관한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.19 no.2
    • /
    • pp.193-200
    • /
    • 2015
  • In this paper, we propose the radiation measuring algorithm and the device composition using CMOS image sensor. The radiation measuring algorithm using CMOS image sensor is based on the radiation particle distinguishing algorithm projected to the CMOS image sensor and accumulated and average number of pixels of the radiation particles projected to dozens of images per second with CMOS image sensor. The radiation particle distinguishing algorithm projected to the CMOS image sensor measures the radiation particle images by dividing them into R, G and B and adjusting the threshold value that distinguishes light intensity and background from the particle of each image. The radiation measuring algorithm measures radiation with accumulated and average number of radiation particles projected to dozens of images per second with CMOS image sensor according to the preset cycle. The hardware devices to verify the suggested algorithm consists of CMOS image sensor and image signal processor part, control part, power circuit part and display part. The test result of radiation measurement using the suggested CMOS image sensor is as follows. First, using the low-cost CMOS image sensor to measure radiation particles generated similar characteristics to that from measurement with expensive GM Tube. Second, using the low-cost CMOS image sensor to measure radiation presented largely similar characteristics to the linear characteristics of expensive GM Tube.

Encoder Type Semantic Segmentation Algorithm Using Multi-scale Learning Type for Road Surface Damage Recognition (도로 노면 파손 인식을 위한 Multi-scale 학습 방식의 암호화 형식 의미론적 분할 알고리즘)

  • Shim, Seungbo;Song, Young Eun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.2
    • /
    • pp.89-103
    • /
    • 2020
  • As we face an aging society, the demand for personal mobility for disabled and aged people is increasing. In fact, as of 2017, the number of electric wheelchair in the country continues to increase to 90,000. However, people with disabilities and seniors are more likely to have accidents while driving, because their judgment and coordination are inferior to normal people. One of the causes of the accident is the interference of personal vehicle steering control due to unbalanced road surface conditions. In this paper, we introduce a encoder type semantic segmentation algorithm that can recognize road conditions at high speed to prevent such accidents. To this end, more than 1,500 training data and 150 test data including road surface damage were newly secured. With the data, we proposed a deep neural network composed of encoder stages, unlike the Auto-encoding type consisting of encoder and decoder stages. Compared to the conventional method, this deep neural network has a 4.45% increase in mean accuracy, a 59.2% decrease in parameters, and an 11.9% increase in computation speed. It is expected that safe personal transportation will be come soon by utilizing such high speed algorithm.

Effect of Electro-acupuncture on Regional Fat by Measuring Thigh Circumference (저주파 전침자극이 허벅지 둘레에 미치는 영향에 대한 연구)

  • Ahn, Soo-Jeong;Kim, Jeung-Shin;Shin, Hyun-Taeg;Kim, Yong-Suk;Lee, Kyung-Sub;Hwang, Deok-Sang
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.5 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • Objectives: Although electro-acupuncture is being utilized to reduce weight in Korea, its usefulness in obesity management has not been fully evaluated yet. The objective of this study is to evaluate the effect of Electro-acupuncture on thigh circumference. Methods: 12 healthy volunteers participated in this study. We measured the circumference of both thighs, and treated the thicker one with transcutaneous electro-acupuncture at 8 acupoints, 10 times in total. The electrical parameters were : 1st step frequency set was at 15Hz and the treatment proceeded for 50 minutes, 2nd step at 50Hz for 10 minutes and at 3rd step the acupunctures were removed and electrodes were attached on the lower limb at 166Hz for 15 minutes. In order to evaluate the effect of the treatment, total body weight, percentage of body fat and thigh circumference were measured 4 times. Before the treatment, after 5th and 10th treatment and 1 month after completion of the whole treating procedure. Statistical significance(P<0.05) was determined using the Wilcoxon signed rank test. We did not control diet, exercise and lifestyle of the volunteers. Results: No significant change was shown in body weight after 10 times of treatment. Yet the thigh circumference of effect group significantly decreased after 5th treatment and 10th treatment. The circumference of control group that was not treated by electro-acupuncture significantly decreased too. At first, difference between the two thighs in circumference was obvious, but no difference was left after 10 times of treatments on the thicker thigh. Percentage of body fat was significantly decreased. 1 month after having completed the treatment, there was no significant difference of body weight, thigh circumferences and percentage of body fat. Conclusion: These results suggest that electro-acupuncture effectively regulates regional fat, body fat percentage and body shape.

  • PDF

A Study on the Photo-Conductive Characteristics of (p)ZnTe/(n)Si Solar Cell and (n)CdS-(p)ZnTe/(n)Si Poly-Junction Thin Film ((p)ZnTe/(n)Si 태양전지와 (n)CdS-(p)ZnTe/(n)Si 복접합 박막의 광도전 특성에 관한 연구)

  • Jhoun, Choon-Saing;Kim, Wan-Tae;Huh, Chang-Su
    • Solar Energy
    • /
    • v.11 no.3
    • /
    • pp.74-83
    • /
    • 1991
  • In this study, the (p)ZnTe/(n)Si solar cell and (n)CdS-(p)ZnTe/(n)Si poly-junction thin film are fabricated by vaccum deposition method at the substrate temperature of $200{\pm}1^{\circ}C$ and then their electrical properties are investigated and compared each other. The test results from the (p)ZnTe/(n)Si solar cell the (n)CdS-(p)ZnTe/(n)Si poly-junction thin fiim under the irradiation of solar energy $100[mW/cm^2]$ are as follows; Short circuit current$[mA/cm^2]$ (p)ZnTe/(n)Si:28 (n)CdS-(p)ZnTe/(n)Si:6.5 Open circuit voltage[mV] (p)ZnTe/(n)Si:450 (n)CdS-(p)ZnTe/(n)Si:250 Fill factor (p)ZnTe/(n)Si:0.65 (n)CdS-(p)ZnTe/(n)Si:0.27 Efficiency[%] (p)ZnTe/(n)Si:8.19 (n)CdS-(p)ZnTe/(n)Si:2.3 The thin film characteristics can be improved by annealing. But the (p)ZnTe/(n)Si solar cell are deteriorated at temperatures above $470^{\circ}C$ for annealing time longer than 15[min] and the (n)CdS-(p)ZnTe/(n)Si thin film are deteriorated at temperature about $580^{\circ}C$ for longer than 15[min]. It is found that the sheet resistance decreases with the increase of annealing temperature.

  • PDF

A study on the oxide semiconductor $[(I_{n2}O_3)_x{\cdot}(S_nO_2)_{1-x}]_{(n)}/Silicon(p)$, solar cells fabricated by two source evaporation (이가열원(二加熱源) 증착법(蒸着法)에 이한 산화물(酸化物) 반도체(半導體) $[(I_{n2}O_3)_x{\cdot}(S_nO_2)_{1-x}]_{(n)}/Silicon(p)$, 태양전지(太陽電池)에 관한 연구(硏究))

  • Jhoon, Choon-Saing;Kim, Yong-Woon;Lim, Eung-Choon
    • Solar Energy
    • /
    • v.12 no.2
    • /
    • pp.62-78
    • /
    • 1992
  • The solar cells of $ITO_{(n)}/Si_{(p)}$, which are ITO thin films deposited and heated on Si wafer 190[$^{\circ}C$], were fabricated by two source vaccum deposition method, and their electrical properties were investigated. Its maximum output is obtained when the com- position of the thin film consist of indium oxide 91[mole %] and thin oxide 9[mole %]. The cell characteristics can be improved by annealing but are deteriorated at temperature above 600[$^{\circ}C$] for longer than 15[min]. Also, we investigated the spectral response with short circuit current of the cells and found that the increasing of the annealing caused the peak shifted to the long wavelength region. And by experiment of the X-ray diffraction, it is shown to grow the grains of the thin film with increasment of annealing temperature. The test results from the $ITO_{(n)}/Si_{(p)}$ solar cell are as follows. short circuit current : Isc= 31 $[mW/cm^2]$ open circuit voltage : Voc= 460[mV] fill factor : FF=0.71 conversion efficiency : ${\eta}$=11[%]. under the solar energy illumination of $100[mW/cm^2]$.

  • PDF

Resistance In Chloride ion Penetration and Pore Structure of Concrete Containing Pozzolanic Admixtures (포졸란재 함유 콘크리트의 세공구조와 염화물이온 침투 저항성)

  • 소양섭;소형석
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.1
    • /
    • pp.100-109
    • /
    • 2002
  • Significant damage to concrete results from the intrusion of corrosive solutions, for example, dissolved chlorides corrode reinforcing steel and cause spatting. Effectively blocks the penetration of these solutions will eliminate or greatly reduce this damage and lead to increased durability. This study is to investigate the effects of pozzolanic admixtures, fly ash and silica fume, and a blast furnace slag on the chloride ion penetration of concretes. The main experimental variables wore the water-cementitious material ratios, the types and amount of admixtures, and the curing time. And it is tested for the porosity and pore size distributions of cement paste, chloride ion permeability based on electrical conductance, and 180-day ponding test for chloride intrusion. The results show that the resistance of concrete to the penetration of chloride ions increases as the w/c was decreased, and the increasing of curing time. Also, concrete with pozzolans exhibited higher resistance to chloride ion penetration than the plain concrete. The significant reduction in chloride ion permeability(charge passed) of concrete with pozzolans due to formation of a discontinuous macro-pore system which inhibits flow. It is shown that there is a relationship between chloride ion permeability and depth of chloride ion penetration of concrete, based on the pore structure (porosity and pore size distributions) of cement paste.

Data mining Algorithms for the Development of Sasang Type Diagnosis (사상체질 진단검사를 위한 데이터마이닝 알고리즘 연구)

  • Hong, Jin-Woo;Kim, Young-In;Park, So-Jung;Kim, Byoung-Chul;Eom, Il-Kyu;Hwang, Min-Woo;Shin, Sang-Woo;Kim, Byung-Joo;Kwon, Young-Kyu;Chae, Han
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.6
    • /
    • pp.1234-1240
    • /
    • 2009
  • This study was to compare the effectiveness and validity of various data-mining algorithm for Sasang type diagnostic test. We compared the sensitivity and specificity index of nine attribute selection and eleven class classification algorithms with 31 data-set characterizing Sasang typology and 10-fold validation methods installed in Waikato Environment Knowledge Analysis (WEKA). The highest classification validity score can be acquired as follows; 69.9 as Percentage Correctly Predicted index with Naive Bayes Classifier, 80 as sensitivity index with LWL/Tae-Eum type, 93.5 as specificity index with Naive Bayes Classifier/So-Eum type. The classification algorithm with highest PCP index of 69.62 after attribute selection was Naive Bayes Classifier. In this study we can find that the best-fit algorithm for traditional medicine is case sensitive and that characteristics of clinical circumstances, and data-mining algorithms and study purpose should be considered to get the highest validity even with the well defined data sets. It is also confirmed that we can't find one-fits-all algorithm and there should be many studies with trials and errors. This study will serve as a pivotal foundation for the development of medical instruments for Pattern Identification and Sasang type diagnosis on the basis of traditional Korean Medicine.

Acupuncture and Herbal Medicine Improved the Quality of life of Obese Women (한방치료를 받은 여성 비만환자의 삶의 질 연구)

  • Jung, Soon-Kwan;Yeom, Seung-Ryong;Kwon, Young-Dal
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.4
    • /
    • pp.1034-1038
    • /
    • 2007
  • To examine the difference of health-related quality of life (QoL) of obese patients between before and after treatment of Korean traditional medicine. This study was assessed in 18 obese-women (age 29.72${\pm}$7.38) treated by acupuncture and herbal medicine using SF-36 quality of life questionnaire between January and July 2006, a 36 item instrument yielding 8 dimensions (Social functioning, Role limitation-Physical, Role limitation-Emotion, Mental health, Vitality, Bodily pain, and General health) and a total score. Their weight was measured by Inbody 3.0 (Biospace co. Korea). QoL and body composition was assessed twice at baseline (B) and 4 weeks after treatment. Auricular acupuncture and electrical needle stimulation to abdomen, thigh, and arm fat was used twice a week and complex herb formula was prescribed according to their constitution and symptoms for 4 weeks. Herb medication was taken 2 times a day. Respective variables were analyzed with Wilcoxon signed ranks test and the level set for statistical significance was p <0.05. The mean of the body weight (P=0.000;B64,68${\pm}$6.86, 4 WKs 60.47${\pm}$5.69), fat percentage (P=0.000;B33.14${\pm}$4.86, 4 WKs 30.16${\pm}$5.34), body mass index (P=0.000;B25.18${\pm}$2.44, 4 WKs 23.46${\pm}$2.09) and fat weight (P=0.000;B21.66${\pm}$5.06, 4 WKs 18.41${\pm}$4.57) of some obese patients decreased significantly between before and after treatment for 4 weeks. Physical functioning (P=0.48;B27.06${\pm}$3.17, 4 WKs 28.00${\pm}$1.71), Mental health (P=0.01 ;B18.83${\pm}$5.25, 4 WKs 22.00${\pm}$3.73), Vitality (P=0.028;B13.89${\pm}$3.03, 4 WKs 15.44${\pm}$2.53), Bodily pain (P=.0014;B8.84${\pm}$1.75, 4 WKs 10.15${\pm}$1.78), and the total scores (P=0.001;B104.99${\pm}$12.60, 4 WKs 114.58${\pm}$11.11) of SF-36 were increased significantly after treatments. These data show some differences in QoL and BMI between before and after treatment on obesity and suggest that the treatment with acupuncture and herbal medicine have a positive impact on several domains of QoL of some obese patients. Further randomized clinical trials (RCTs) including follow-up are needed to examine whether acupuncture and herb medicine have a positive effect on QoL of treatment group compared with control group.

A Study on the Elaboration of Request for Proposal of Localization Parts using AHP method (AHP 기법을 적용한 부품국산화 제안요청서 정교화 연구)

  • Song, Hyeong-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.35-44
    • /
    • 2020
  • The purpose of this study is to elaborate the request for proposal (RFP) for the localization parts development support project of core parts carried out by the Defense Agency for Technology and Quality. The RFP is the most important document throughout the localization parts project, including project announcement and developer selection, design and test of the development product, final evaluation, and standardization of the project. However, if the RFP is not established at the beginning of the project, there is an increased risk of business failure due to frequent changes by various reasons. In this study, we recognized the necessity of elaboration of RFP and applied the AHP method for quantitative elaboration. Eight requirements of the RFP related to the mechanical/electrical performance of localized development products and three elaboration methods for each requirement were designed in a hierarchical structure, and each weight was calculated by applying the 5-point scale AHP method. The AHP survey was conducted with 20 developers participating in the localization parts project, and the consistency ratio of the AHP survey result was less than 0.1. The elaboration method with the highest value among the calculated weights is classified, and the analysis results and future research directions of the elaboration method are presented.

A study on the Operation Algorithm for Bi-directional Sectonalizer in Distribution System Interconnected with Distributed Generations (분산전원이 연계된 배전계통의 양방향 구간개폐기의 동작 알고리즘에 관한 연구)

  • Yoon, Gi-Gab;Jeong, Jum-Soo;An, Tae-Pung;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.1802-1809
    • /
    • 2009
  • Abstract The typical distribution systems have the power flow from distribution substations (sources) to customers (load) only as one direction. However, in the case where distributed generations (DG) such as PV system and wind power systems are connected to distribution systems, the DG output variations to distribution systems, so called reverse power flow, may cause the bi-directional power flow. So, the reverse power flow has severe impacts on typical power system, for example power quality problems, protection coordination problems, and so on. Especially, protection devices (sectionalizer) in primary feeder of distribution system interconnected with distributed generations may cause problems of malfunction, and then many customers could have problems like an interruption. So, this paper presents the bi-directional operation algorithm of protection devices to overcome the problems like mal-function. And, also this paper shows the effectiveness of proposed method by using both PSCAD/EMTDC software and test facility of protection devices to simulate the field distribution systems.