• Title/Summary/Keyword: Electrical shock

Search Result 405, Processing Time 0.027 seconds

A study on the analysis of actual main line systems of entertainment places (공연장내 간선설비에 대한 현장실태분석 연구)

  • Bae, S.M.;Kim, H.S.;Gil, H.J.;Yi, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1765-1767
    • /
    • 2003
  • The standard of living has been getting higher by reason of industrialization and economic growth. It makes people have more cultural desire(wants). Because of reasons mentioned above, a number of entertainment place and performance with high-tech is increased. This has been brought also increasing a number of electrical accident such as electrical shock, electrical fires and accidents of electrical facilities. This paper suggests technical, operational and special precautions of actual electric main line systems in entertainment places and is also written on the purpose of being applied with related provisions to designing electrical facilities, construction, check-up and inspection and maintenance for preventing further electrical disasters in entertainment places.

  • PDF

Comparison of the RCA Between China and KOR: From the Perspective of Value-Added

  • Xiaosong Jiao;Yingqi Cao;Lily Jiao;Chandaith Neak;Yaqian Zhang
    • Journal of Korea Trade
    • /
    • v.26 no.4
    • /
    • pp.23-38
    • /
    • 2022
  • Purpose - This paper empirically explores the RCA of electrical equipment trade between China and Korea from the perspective of gross trade and value-added trade. The goal of this paper is to scan the electrical equipment's RCA, the decomposition of gross exports, and the impacts of an exerted shock. Design/methodology - We applied the domestic value-added method in measuring the RCA, which could be more accurate than traditional RCA since it excludes foreign value-added. Based on the research purpose, this paper follows the framework of Koopman, Wang, and Wei (2014)-as extended by Wang, Wei, and Zhu (2018). It extracts the data from the 2019 Multi-regional Input-Output (MRIO) databases compiled by the Asian Development Bank in January 2021. Findings - After rigorous examination, the main findings are as follows: First, the electrical equipment sector maintains a consistent comparative advantage in either assessing method. Second, China exports more gross goods of electrical equipment to the world than South Korea does, but there is a trade deficit with Korea. Third, South Korea and P.R. China are the most significant bilateral partners of foreign value-added sourcing. Finally, it is surprising that there is a shock on electrical equipment; the partner's service, as well as manufacturing sectors, would be affected. Originality/value - This paper explores the revealed comparative advantage between Korea and China from traditional gross export and value-added perspectives. Second, we apply the information from the 2019 MRIO database compiled by the Asian Development Bank in January 2021, reflecting the current situation. Third, this paper analyzes the electrical equipment and the impacts on other parties' sectors. Finally, we carry out the subjects that deserve to be investigated in the future.

The Analysis of Field Condition for Power Receiving System and Patch and Panel Boards at Construction Sites (건설현장의 수전설비 및 배.분전반의 현장실태 분석)

  • Gil, Hyoung-Jun;Han, Woon-Ki;Kim, Hyang-Kon;Choi, Chung-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.335-340
    • /
    • 2004
  • To analyze risk factors of temporary power installations, the investigation was carried out for power receiving system and pack and panel boards at construction sites. The subject was variable such as an airport, an apartment, a municipal playground. There are many risk factors caused by inadequate working environments and the deterioration of temporary power installations using equipment with minimum safety devices at construction sites. There, it is intended to present problems and preventive measures against electrical shock accidents, through analyzing risk factors of real field condition and investigating temporary power installations all over the country.

  • PDF

The Analysis of Potential Distribution for Submerged Electrical Fittings in an Underground Shopping Street (지하상가 침수 시 전기설비 전위분포 해석)

  • Jung, Jin-Soo;Jung, Jong-Wook;Kim, Sun-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2072-2073
    • /
    • 2007
  • This paper describes the analysis of potential distribution and leakage current magnitude around the electrical fittings submerged in an underground shopping street. In the experiment, a couple of electrical utilities(outlet, fluorescent lamp) were submerged in a concrete water bath. The experimental results are expected to be utilized for the risk assessment and the safety countermeasure against the electric shock.

  • PDF

Development of Drainage Water Disinfection System by Electric Shock in Recirculating Soilless Culture (순환식 수경재배에서 배액의 전기충격살균법 연구)

  • Lee, Mun Haeng;Kim, Sung Eun;Lee, Sang Don;Lee, Jae Eun;Kim, Hak Sun;Cho, Suk Keong;Sim, Sang Youn;Kim, Young Shik
    • Journal of Bio-Environment Control
    • /
    • v.25 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • This study was conducted to develop the disinfection system using electric shock for recycled nutrient solution in recycling soilless culture. Stainless steel (SUS 316) was found as the most appropriate electrode material for electrical disinfection system from the view of high electrical conductivity, low electric resistance, and low price. There were no changes in nutritional elements when the electric shock passed through the nutrient solution by stainless steel electrode. The amount of electric current increased with width than thickness of the electrode. The farther the distance between the electrodes was increased the time to reach out the aimed amount of current. The electric shock was applied to Ralstonia solanacearum and Fusarium oxysporum as representative bacteria and also fungi. Any of those pathogens were killed with the percentage of higher than 97% in the condition of 15VDC or 24VDC.

The analysis for flooding prevention countermeasures of Electrical facility and Transformer Vault on Foreign (국외 수변전실 및 지상 전력기기 침수방지 대책에 관한 조사연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Jean, Hyun-Jae;Bae, Suk-Myong;Lee, Jae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.305-307
    • /
    • 2008
  • Inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-tying shore by heavy rain, typhoon and tidal wave. In case inundation excluding the exchanging cost of equipment, it occurs a great economic and social loss owing to recovery time and events of electric shock occur by inundation electrical equipment (Pad-mounted Transformer and Switch). So we research the flooding prevention countermeasures of electrical facility and Transformer Vault on Foreign. We conform the site facility and related regulation for flooding prevention on Foreign.

  • PDF

Study on the Evaluation Method of Electrical Isolation Property for Hydrogen Fuel Cell Vehicle (수소연료전지자동차의 절연성능 평가방법에 관한 고찰)

  • Lee, Ki-Yeon;Kim, Dong-Ook;Kim, Hyang-Kon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.6
    • /
    • pp.810-818
    • /
    • 2011
  • This paper analyzed the suitability about the isolation performance criteria which was based on human impedance and effect of current in IEC 60479-1 on the safety of human being was examined. The method of evaluation by megger and DC voltmeter was analyzed. The differences of isolation performance according to design of high-voltage system were analyzed. The factors which affect the insulation performance were analyzed for HFCV, EV, HEV, etc. through analysis of the isolation performance evaluation method. Finally, design for improved isolation performance was proposed.

A Power Line Proximity Detecter for Mobile Crane (크레인의 고압 전선로 접근 경보장치)

  • Choi, Sam-Jin;Kim, Hyun-Sik;Lee, Jong-Ho;Kim, Il-Hwan;Park, Chan-Won
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2374-2376
    • /
    • 2001
  • In this paper we have developed a Power Line Proximity Detecting device for Mobile Crane by using a Derivation Electric-Potential Detection method. A mobile crane worker can be easily exposed to a dangerous electrical shock and the electrocution while they are working at near the high-voltage electrical lines. The derivation electric-potential of the power lines have been simulated in our experiment, Also, microprocessor-based detecting device and transmitter/receiver modules are introduced to show a solution for the dangerous mobile crane working environment. As a result, It has been shown a good functional field test.

  • PDF

The Assesment of Electric Shock Rate of Low Voltage Joint-Box Based Submerged Condition (침수조건에 따른 저압 지중함의 감전 위험성 평가)

  • Shim, Keon-Bo;Kim, Kung-Chul;Kim, Han-Sang;Kim, Jong-Min
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.265-270
    • /
    • 2007
  • The potential and step voltage distribution around low voltage joint-box cover were simulated with the variation of resistivity of water, depth of submerged water and point of leakage current. The potential distribution is very high gradient around low voltage joint-box, this condition is very dangerous states.

  • PDF

Application Technologies of Pulsed Power with the High Voltage and Current (고전압.대전류 pulsed power의 이용기술)

  • Lee, Hyeong-Ho;Kim, Young-Bae
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1678-1680
    • /
    • 1997
  • The pulsed power with the high voltage and current can be used to the fields of high speed pulses of energy in different forms such as electric current and voltage, electron beam, ion beam, x-rays, gamma rays, heat, magnetics fields, sound and shock waves. This paper is directed mainly at electrical engineers working on production and practical application of high speed pulsed power with high voltage and current.

  • PDF