• 제목/요약/키워드: Electrical safety System

검색결과 1,371건 처리시간 0.034초

공항철도의 기전시스템에 대한 안전성 활동 소개 (Introduction of Safety Activities for Electrical and Mechanical System in Airport Railroad)

  • 임성수;신석균;이창환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.1088-1096
    • /
    • 2006
  • In this paper, the results of safety activities for Airport Railroad are introduced according to CENELEC standards. The procedures of safety activity were redefined as 6 phases such as Requirement Analysis phase, Design phase, Manufacture phase, Installation phase, Test & Commissioning phase and Operation phase to ensure the coincidence with 14 phases recommended in CENELEC standard. And the safety activities were implemented in the aspect of the overall E&M system level and in the aspect of each system level for 6 sub-systems consisting of that E&M system to ensure the safety for Airport Railroad using the general methodology such as FMECA.

  • PDF

u-IT 전기안전통합관리시스템의 모듈별 성능평가와 보안방법 연구 (A Study on Performance Evaluation and Security Methods of u-IT Electrical Safety Integrated Management System's Module)

  • 박대우;김응식;최종문
    • 한국정보통신학회논문지
    • /
    • 제14권6호
    • /
    • pp.1447-1452
    • /
    • 2010
  • Ubiquitous 사회에서 기본 인프라를 구축하는 전력 공급망과 전력기기의 안전은 중요하다. u-City의 재난을 방지하기 위하여 u-IT전력기기의 모듈별 성능평가와 보안은 u-City 안전을 위해 꼭 필요하다. 본 논문에서는 u-IT전력기기의 모듈에 온도센서, 습도센서, 화재센서들을 탑재한 수배전반, 홈 분전반, Home Network Wall-Pad, 차단기, MPNP 블랙박스, 아크 검출기, 아크 안전기, 아울렛의 모듈별 성능평가 방안과 방법 및 보안방법을 연구한다. u-IT전력기기들은 센서의 정보들을 전달 및 분석하여 위험성을 사전 예방하여 안전성을 확보하고, 접근제어, 인증 등 보안대책으로 u-IT 전기안전통합관리시스템의 보안성을 강화시켜, 안전성과 보안성을 갖춘 u-City건설과 운영에 기여하게 될 것이다.

과전류 열화에 의해 용단된 전선의 수지상 조직 성장특성에 관한 연구 (A Study on the Growing Characteristics of Dendrite Structure of Melted Wire Deteriorated by Over Current)

  • 송길목;최충석;김동우;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1463-1465
    • /
    • 2003
  • In this paper, we studied on the growing characteristics of dendrite structure of melted wire deteriorated by over current. Electric wire was melted by Jolue's heat. By using HSIS(High Speed Imaging System), we found out a lot of melted parts of wire were dispersed and radiated. Electric wire had narrow melted areas in case of short fusing time. A lot of very small dots generated around the grain of copper cross-section and they were changed into dendrite structure. Dendrite structure appeared at the values lower than 2.5[A/sec]. In case of very short fusing time, fusing current was calculated by empirical formula. The Preece equation was not enough to analyze a variety of characteristics of melted wire because it did not consider melting time, atmosphere, etc.

  • PDF

직류전동기 구동장치의 고조파 저감을 위한 수동필터 제어시스템 연구 (A Study on the Passive Filter Control System to reduce harmonic of DC Motor drives)

  • 이상익;유재근;전정채
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.280-282
    • /
    • 2004
  • 본 논문에서는 고조파 저감을 위해 사용하는 수동필터를 부하의 운전조건에 따라 자동으로 $개\cdot폐$할 수 있는 DSP 기반의 제어시스템을 개발하였다. 수동필터 제어시스템은 부하에서 발생하는 전압, 전류, 고조파, 무효전력, 역률 등을 측정 및 감시하여 수동필터 $개\cdot폐$ 장치에 신호를 보내어 부하의 운전조건에 따라 필터의 각 분로를 자동으로 $개\cdot폐$하게된다. 이러한 제어시스템은 100마력 직류전동기 구동장치를 사용하는 계통에 수동필터와 함께 설치하고 고조파 및 무효전력등을 측정함으로써 성능을 입증하였다.

  • PDF

다채널 전력분석을 위한 데이터 획득시스템에 관한 연구 (A Study on the Data Acquisition System for Multi-Channel Power Analysis)

  • 유재근;전정채;이상익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.333-335
    • /
    • 2004
  • 전기부하설비의 전압, 전류, 전력, 고조파등의 분석을 위해서는 수학적 모델링 보다는 실제 계측을 통한 전력분석이 필요하고 이론 통해 전기설비의 효율적인 관리, 에너지 절약 및 사고 예방에 필요한 대책을 수립할 수 있다. 특히 전력 및 고조파 유입 유출 등을 분석하기 위해서는 여러 지점의 전력분석을 위한 다채널 데이터 획득시스템은 매우 필수적이다. 따라서 본 논문에서는 전압 및 전류를 다채널로 동시에 측정할 수 있는 데이터 획득 시스템을 DSP 기반으로 개발하였다.

  • PDF

The Characteristics of Charging Water Spray at Electrostatic Precipitator

  • Chung, J.H.;Kanazawa, S.;Ohkubo, T.;Nomoto, Y.;Adachi, T.
    • 한국안전학회지
    • /
    • 제9권4호
    • /
    • pp.132-136
    • /
    • 1994
  • The new spray system is proposed by using a pipe with hygroscopic needle electrode In order to develop an air-cleaning ESP with high collection efficiency for submicron particles and high removal efficiency for NOx, SO$_2$, NH$_3$. Fundamental characteristics of charging water spray, which is not an usual wet type, are investigated experimentally. As a result, corona discharging mode and ozone generation rate are significantly affected by the operational conditions, such as the applied voltage and wet condition of the needle electrode.

  • PDF

필수성능 분석을 통한 효율적인 의료기기 기능안전 접근 방안 (Efficient Approaches of Functional Safety for Medical Equipment using Essential Performance Analysis)

  • 김기영;유기훈;박호준;장중순
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제15권1호
    • /
    • pp.27-32
    • /
    • 2015
  • Functional safety is part of the overall safety relating to the equipment under control (EUC) and the EUC control system that depends on the correct functioning of the electrical/electronic/programmable electronic (E/E/PE) safety-related systems. Since the complexity of the medical equipment is increased, manufactures have to obtain functional safety as well as basic safety. This study proposes a perspective for applying functional safety to medical equipment. The research is carried out with respect to overall safety life-cycle of functional safety and essential performance of the medical equipment. The relationship between functional safety and essential performance is identified centered on the safety function. The essential performance using E/E/PE systems is defined as a safety function of functional safety. This approach is applied to a ultrasound imaging system as a case study.

반 정량적 리스크 저감 요소를 고려한 철도 승강장 스크린 도어시스템의 안전 무결성 수준 할당 (Allocation of Safety Integrity Level for Railway Platform Screen Door System considering Semi-Quantitative Risk Reduction Factor)

  • 송기태;이성일
    • 한국안전학회지
    • /
    • 제31권4호
    • /
    • pp.156-163
    • /
    • 2016
  • There exists required safety integrity level (SIL) to assure safety in accordance with international standards for every electrical / electronics / control equipment or systems with safety related functions. The SIL is allocated from lowest level (level 0) to highest level (level 4). In order to guarantee certain safety level that is internationally acceptable, application of methodology for SIL allocation and demonstration based on related international standards is required. However, the theoretical and practical study for safety integrity level is barely under way in the domestic railway industry. This research studied not only the global process of SIL allocation to guarantee safety in accordance with international standards for safety related equipment and system, but the quantitative methodology based on international standard and the semi-quantitative methodology as alternative way for SIL allocation. Specifically, the systematic SIL allocation for platform screen door system of railway is studied applying the semi-quantitative methodology in order to save much time and effort compared to quantitative method.

전기 감전 체험 교육을 위한 저주파 전류 자극기의 인체 자극 임계값 (Human Stimulation Threshold of Interferential Current Type Low Frequency Stimulator for Electric Shock Experience Education)

  • 전정채;김재현;유재근
    • 한국산학기술학회논문지
    • /
    • 제13권10호
    • /
    • pp.4768-4772
    • /
    • 2012
  • 전기감전 사고를 예방하기 위해서는 주입식 교육 보다는 체험식 교육이 더욱 효과적이다. 그러나 전기감전 체험형 교육 시스템을 위해서는 감전을 체험할 수 있도록 인체에 대한 적절한 물리적 자극이 필요하다. 본 논문에서는 간섭전류형자극기(Interferential Current Type Low Frequency Stimulator)를 감전사고 체험교육에 이용하기 위하여 인체에 대한 자극의 임계값을 실험하였다. 그리고 아동과 성인으로 구분된 연령별 자극 값을 산출하였다. 본 연구의 결과는 전기 감전 체험형 교육 시스템에 적용 가능할 것이다.

파워 어시스트 시스템을 위한 이동 머니퓰레이터의 제어 (Control of Mobile Manipulators for Power Assist Systems)

  • 이형기;성영휘;정명진
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제49권2호
    • /
    • pp.74-80
    • /
    • 2000
  • In this paper, we present a control method of mobile power assist systems. Most of mobile power assist systems have a heavy base for preventing easy tumbling, so continual movement of the base during operations causes high energy consumption and gives the high risk of human injury. Furthermore, the slow dynamics of the base limits the frequency bandwidth of the whole system. Thus we propose a cooperation control method of the mobile base and manipulator, which removes the unnecessary movements of the base. In our scheme, the mobile base does not move until the center of gravity(C.G) of the system goes outside a safety region. When C.G. reaches the boundary of the safety region, the base starts moving to recover the manipulator's initial configuration. By varying the parameters of a human impedance controller, the operator is warned by a force feedback that C.G. is on the marginal safety region. Our scheme is implemented by assigning a nonlinear mass-damper-spring impedance to the tip of the manipulator. Our scheme is implemented by a nonlinear mass-spring impedance to the tip of the manipulator. The experimental results show the efficacy of the proposed control method.

  • PDF