접지계의 써어지 임피던스 (Surge Impedance of Grounding System)

  • 김왕
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제6권5호
    • /
    • pp.45-49
    • /
    • 1992
  • The transient characteristics of grounding systems are very important in the insulation design of electrical installations and depend on the shape and size of electrodes, soil resistivity and the magnitude and wave of the injection current. This paper establishes an algorithm to compute the surge impedance of two or more grounding systems using the Laplace Transformation technique and deals with the analysis of the transient characteristics on grounding systems.

  • PDF

Pattern Search 법을 이용한 중성선 고조파 해석용 접지 임피던스 모델링 (The Ground Impedance Modeling using pattern Search Method for Neutral Hormonic Analysis)

  • 백승현;김경철;최종기;이일무;백남웅
    • 조명전기설비학회논문지
    • /
    • 제18권4호
    • /
    • pp.181-187
    • /
    • 2004
  • 3상 4선식 배전계통을 채용하는 우리나라는 비선형 부하의 증가로 중성선에는 많은 중성선 고조파 전류가 관측되고 있다. 또한 접지 임피던스는 고조파가 있는 중성선 전류에 영향 끼친다고 알려져 있다. 전위 강하법에 따라 현장에서 실측한 고조파 전류와 전압을 측정하고, Pattern Search 기법으로 고조파 해석용 접지 임피던스를 모델링 하였다. 여기서 구한 임피던스 모델은 현장 시험에 의한 임피던스 모델과 비교하여 유사한 결과를 얻었고, 접지 시스템의 고조파 및 과도 응답 특성을 평가하는데 활용될 것으로 사료된다.

IEC 60364 기반 접지계통 비교 분석 (The Comparison and Analysis about Earth System based on IEC60364)

  • 정진수;한운기;김오환;김재철
    • 조명전기설비학회논문지
    • /
    • 제24권1호
    • /
    • pp.56-62
    • /
    • 2010
  • 본 논문에서는 IEC 60364에서 제시하고 있는 접지계통(TT접지계통, TN-S 접지계통 및 TN-C)의 누전차단기 동작특성 및 보호도체의 임피던스변화에 따른 Loop Impedance 특성분석을 실시하였다. 분석결과 Loop Impedance의 경우 저항성분과 인턱턴스성분에 영향을 받는 것으로 나타났다. 접지계통별 전류 전압특성은 TN-S 접지계통 및 TN-C 접지계통의 경우 사고전류가 높고 접촉전압이 낮은 특성을 나타낸 반면 TT 접지계통의 경우 사고전류는 낮고 접촉전압이 높게 나타남을 확인하였다.

전기철도 AT급전계통 전력해석을 통한 실계통의 단락전류 분석 (The Analysis of Short Current on Actual System through Power Analysis of AT Feeder System for Electric Railway)

  • 정노건;정호성;구경완;김재문
    • 전기학회논문지
    • /
    • 제63권11호
    • /
    • pp.1582-1587
    • /
    • 2014
  • In this paper, we perform a modeling for the AT Feeder system in AC electric railway and we utilize the power EMTDC program to implement about AT feeder system modeling. In addition, we study the impedance characteristics of the AT feeder system and calculated fault current and impedance according to the distance due to fault accident. Based on it's result, fault current are compared between calculating the value and simulation value in EMTDC modeling. Impedance of power system is Largest at the middle point of the system and is smallest near autotransformer, and then showed that the fault current is inversely proportional to impedance characteristics.

다중 대역 소자 응용을 위한 다단 계단형 임피던스 공진기의 해석 (Analysis of Multi-stage Stepped Impedance Resonator for Application of Multi-band Devices)

  • 윤태순
    • 한국ITS학회 논문지
    • /
    • 제11권5호
    • /
    • pp.97-102
    • /
    • 2012
  • 본 논문에서는 다양한 초고주파 시스템에서 SIR의 다양한 응용을 위해 반파장 공진기로 등가되는 다단 SIR의 입력 임피던스를 통해 각 단의 전기적 길이 및 고차 하모닉 주파수를 계산하였다. 다단 SIR의 크기 감소율은 단수의 증가에 따라 다소 감소하고 임피던스 비에 의해 지배적으로 영향을 받으며, 하모닉 특성은 단수에 따른 변화가 미미하며 임피던스 비가 작아질수록 기본 공진주파수에서 멀어지게 된다. 또한, 다단 SIR의 등가 임피던스는 가장 낮은 특성 임피던스와 가장 높은 특성 임피던스의 기하평균 값을 가지며 Q 값은 반파장 공진기와 유사한 특성을 보였다.

EMTP를 이용한 매설지선의 규약접지임피던스 해석 (Analysis for the conventional impedance of counterpoise using EMTP)

  • 김종호;조정현;백영환;이강수;이복희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.47-50
    • /
    • 2009
  • When the lightning currents flow through the ground electrode, the grounding system should be evaluated by the grounding impedance rather than the ground resistance because a grounding system shows the transient impedance characteristic by the inductance of the ground electrode and the capacitance of the soil. The ratio of the peak values of electric potential and currents is the conventional impedance that shows the transient characteristic about impulse currents of the grounding system in a roundabout way. The grounding system having low conventional impedance is a fine grounding system with low electric potential when the lightning currents flow. In this paper the conventional impedance of the counterpoise is calculated by using the distributed parameter circuit model and embodied the distributed parameter circuit model by using the EMTP program The adequacy of the distributed parameter model is examined by comparing the simulated and the measured results. The conventional impedance of the counterpoise is analyzed for first short stroke and subsequent short stroke currents.

  • PDF

토양의 저항률 및 비유전율의 주파수의존성을 고려한 접지봉의 접지임피던스의 해석 (Analysis of the Grounding Impedance of a Ground Rod Considering the Frequency-Dependent Resistivity and Relative Permittivity of Soil)

  • 안창환;최종혁;이복희
    • 조명전기설비학회논문지
    • /
    • 제26권1호
    • /
    • pp.54-60
    • /
    • 2012
  • When the transient current with high frequency components such as lightning surges are injected the grounding electrodes, the performance of grounding electrodes should be evaluated as grounding impedance. It is restricted to analyze the grounding impedance by measurement approach since the grounding impedance is very different with the shape and size of grounding electrodes, resistivity and relative permittivity of soil and the frequency component of the injected current. So a variety of simulation approaches have been developed. Typically, the soil resistivity measured with low frequency and relative permittivity between 1 and 80 are used for simulation of the grounding impedance. However, the resistivity and relative permittivity of soil are changed with frequency of injected current. In this paper, the frequency-dependent resistivity and relative permittivity of soil are measured and these parameters are reflected in the simulation of the grounding impedance of a ground rod. The simulated results are compared with the measured results. As a result, the simulated results with frequency-dependent soil parameters show capacitive aspect like measured results in the frequency of lower than 100[kHz] and they are more consistent with the measured results in wide frequency range.

배전전주용 스테인리스강판 접지전극의 접지 특성분석 (Grounding Characteristics Analysis of the Stainless-steel Plate Grounding Electrode for Distribution Poles)

  • 김경철;이규진;김민성;정지원
    • 조명전기설비학회논문지
    • /
    • 제24권8호
    • /
    • pp.94-100
    • /
    • 2010
  • 접지시스템은 전기설비의 기준 전위점을 확보할뿐만 아니라 낮은 대지저항으로 고장전류나 과도 전류를 흐르게 한다. 접지임피던스는 주파수에 대한 함수로 고장이나 과도전류가 넓은 범위의 주파수 성분을 포함하기 때문에 접지성능을 평가하는데 중요한 역할을 한다. 본 논문에서는 스테인리스강판 접지전극의 접지특성을 파악하기 위하여 3점 전위강하법으로 접지저항, 접지임피던스와 과도접지임피던스를 측정하였다. 측정된 데이터를 이용하여 접지임피던스와 과도접지임피던스의 등가 전달함수 모델은 ARMA 기법으로 모델링 되었고, 규약접지임피던스로 비교하여 평가하였다.

광전 방식에 의한 피하 지방층의 비만도 측정에 관한 연구 (A Study on The Fat Measurement at Subcutaneous Adipose by Optical and Electrical Method)

  • 오세용;이영우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 춘계종합학술대회 A
    • /
    • pp.405-407
    • /
    • 2008
  • 광학적 방식에 의한 비침습적으로 신체 전체의 비만도를 측정하기 위해서는 단일 특정 부위에서 측정하는 것은 오차가 너무 크기 때문에 여러 부위에서 측정하고 이를 통계적 방법에 의해서 정확도를 높일 수 있다. 이를 위해서 백색광 LED광원을 이용하고 전기적 방식인 BIA(Bio-electrical Impedance)방식으로 동시에 측정하여 광전기적 지방측정에 관한 상관식을 유도하였다.

  • PDF

AT 급전계통 고장 모의시험장치를 활용한 임피던스 계전방식의 성능검증 (Performance verification on the Impedance Relay Method using Failure Simulator of AT Feeding System)

  • 김완일;이계승;정노건;김재문
    • 전기학회논문지
    • /
    • 제67권2호
    • /
    • pp.325-330
    • /
    • 2018
  • In this paper, we investigated the impedance method for searching fault detection point in case of an accident in the AC electric railway AT feeding system. For this purpose, simulation circuit modeling and prototype hardware are made based on the known numerical analysis. As a result of simulation modeling of the feeding system based on the numerical analysis of the impedance method confirmed that the modeling was properly implemented with an average error rate of 0.07%. Also, as a result of fault event by hardware simulator, it was confirmed that the breaker operation time is shortened and the fault current is decreased while the voltage is close to the supply voltage in the transient state as the point of the fault accident moves away from the substation(SS).