• 제목/요약/키워드: Electrical fire prevention

검색결과 140건 처리시간 0.024초

전기설비의 저항성 누설전류 검출 및 특성 해석에 관한 연구 (Study on the Resistivity Leakage Current Detection and Properties Analysis of Electrical Installat ion)

  • 최충석;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.301-304
    • /
    • 2008
  • In this paper, we study from of flowing leakage current in electrical installation. Leakage current is expressed by a resistivity leakage current($I_{gr}$), a capacitive leakage current($I_{gc}$), an inductivity leakage current($I_{gl}$). General Zero Phase Current Transformer (ZCT) detect a leakage current($I_{g}$) that are conjoined resistivity leakage current and capacitive leakage current. In case $I_{gr}$ is big than $I_{gc}$, there is no singular problem in leakage current detection of system. But, in case $I_{gc}$ is big than $I_{gr}$, earth leakage breaker can not prevent accident effectively. Can lower electric leakage perception current to 5 mA if apply resistivity leakage current detecting circuit. We can achieve prevention of electricity disaster spontaneously.

  • PDF

전기화재 예방용 향 검지기의 현장 적용 사례 연구 (Study on the Field Application of Odor Detector for Electric Fire Prevention)

  • 최충석;김향곤;박윤석;양정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.82-84
    • /
    • 2007
  • 본 논문에서는 전기화재 예방을 위한 향 검지기 및 향 캡슐, 향 센서의 구조와 향 검지 시스템의 동작원리에 대하여 다루었으며, 이 향 검지 시스템을 산업 현장에서 많이 사용되는 단자대(터미널 블록)와 저압용 차단기의 체결나사의 접촉 불량에 의한 이상 발열에 적용하여 향 검지 시스템의 동작 특성과 유효성에 대하여 검증하였다. 향 검지시스템을 현장에 적용하여 확인한 결과 효과적으로 이상 발열을 감지하여 음성과 표시로 관리자에게 통보해 줌을 확인할 수 있었다.

  • PDF

고정밀 전류센서를 이용한 RCD 보조트립 장치 개발 (Development of RCD Auxiliary Trip Device by using High Precision Current Sensor)

  • 곽동걸
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1532-1537
    • /
    • 2009
  • Nowadays the diversity and large-capacity of electric appliances are strong effect on electrical fires augment in an alarming way. But, as the inactive response characteristics of the existing RCD (Residual Current protective Device) used on low voltage power distribution lines, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore this paper is confirmed the unreliability of the existing RCD by electrical faults simulation and is proposed a auxiliary trip device of RCD by using a high precision current sensor (namely, reed switch) for the prevention of electrical disasters in low voltage power distribution lines caused by overload or electric short circuit faults. The sensitive reed switch in the proposed ATD (auxiliary trip device) exactly detects the increased magnetic flux with the overload or the short current caused by a number of electrical faults, and then rapidly cuts off the existing RCD. The proposed auxiliary trip device of RCD is confirmed the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker through various operation performance analysis. The proposed ATD can also prevent electrical disaster, like as electrical fires, which resulted from the malfunction and inactive response characteristics of the existing RCD.

전기화재 방지를 위한 아크고장 판단기법에 대한 연구 (The Arc Fault Determination Method for the Electric Fire Prevention)

  • 고윤석
    • 한국전자통신학회논문지
    • /
    • 제3권4호
    • /
    • pp.260-265
    • /
    • 2008
  • 수용가 시스템에서 발생하는 아크고장은 전기화재의 직접적인 원인이 되지만 기존의 고장검출 메커니즘으로는 확인이 어렵다. 따라서 본 연구에서는 전기화재의 주 원인이 되고 있는 아크고장의 원인을 분석하고 아크고장 기본 검출 메커니즘을 설계하였다. 또한 아크고장 판단의 정확도를 제고시킴으로써 오동작을 최소화할 수 있는 신호처리 기반의 아크고장 판단 방법론을 제안하였다. 끝으로, 하나의 돌입전류에 대해 이산 프리에 변환(DFT)과 이산 웨이블릿 변환(DWT)을 적용, 그 특성을 분석함으로써 신호척리 기반 고장판단 기법의 적용 방법론을 보였다.

  • PDF

Faster R-CNN과 이미지 오그멘테이션 기법을 이용한 화염감지에 관한 연구 (A Study on Flame Detection using Faster R-CNN and Image Augmentation Techniques)

  • 김재중;류진규;곽동걸;변선준
    • 전기전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.1079-1087
    • /
    • 2018
  • 최근 딥러닝(deep learning) 인공지능 기반의 컴퓨터 비전 분야는 각종 영상분석 분야에서 화제로 떠오르고 있다. 본 연구에서는 딥러닝 기반의 여러 이미지 인식 알고리즘 중 이미지 내에서 객체를 검출하는 데 사용되는 Faster R-CNN 알고리즘을 이용하여 화재 이미지에서 불꽃을 검출하고자 한다. 학습 과정에서 소량의 데이터셋을 통한 화재검출 정확도 향상을 위해 이미지 오그멘테이션(image augmentation) 기법을 이용하고, 이미지 오그멘테이션을 6가지 유형별로 나누어 학습하여 정확도, 정밀도, 검출률을 비교하였다. 그 결과, 이미지 오그멘테이션의 종류가 늘어날수록 검출률이 상승하지만, 다른 객체 검출 모델들의 일반적인 정확도와 검출률의 관계와 마찬가지로 오검출율 또한 10%에서 최대 30%까지 증가하게 됨을 확인하였다.

220 V 직렬 아크고장발생 시 점화 시간/전류 특성 및 에너지 분석 (Analysis of Ignition Time/Current Characteristics and Energy when Series Arc-Fault Occurs at Rated 220 V)

  • 고원식;문원식;방선배;김재철
    • 전기학회논문지
    • /
    • 제62권8호
    • /
    • pp.1184-1191
    • /
    • 2013
  • Probability of ignition due to arc-fault and energy of the arc-fault for the case of applying serial arc-fault interruption time of 120 V defined in UL 1699 to the voltage of 220 V of domestic condition and also for the case of applying it to the HIV wire type are analyzed. It has been confirmed that when the arc-fault occurs under 5 A, 10 A, and 20 A. Probability of ignition for the three different current conditions is 0.74(74%), 0.48(48%), and 0.32(32%) respectively for respective interruption time within 1 sec, 0.4 sec, and 0.2 sec. We discover that when we apply the same arc interruption time for 120 V defined in UL 1699 to the domestic environment of 220 V. The probability of ignition increases from 1.5% for 120 V condition to as much as 74% for 220 V condition. Conclusively, if we apply the standard for the serial arc-fault interruption time defined in UL 1699 for 120 V to the domestic condition of 220 V, the fire prevention effect of electric fire due to arc-fault equal to that of UL standard of 120 V can not be achieved.

RTDS-based Model Component Development of a Tri-axial HTS Power Cable and Transient Characteristic Analysis

  • Ha, Sun-Kyoung;Kim, Sung-Kyu;Kim, Jin-Geun;Park, Minwon;Yu, In-Keun;Lee, Sangjin;Kim, Jae-Ho;Sim, Kideok
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2083-2088
    • /
    • 2015
  • The transient characteristics of the tri-axial High Temperature Superconducting (HTS) power cable are different from those of a conventional power cable depending on whether the cable is under a steady or transient state due to the quench. Verification using simulation tools is required to confirm both the characteristics of the cable and the effect of the cable when it is applied to a real utility. However, a component for the cable has not been provided in simulation tools; thus the RTDS-based model component of the tri-axial HTS power cable was developed, and a simulation was performed under the transient state. The considered properties of model component include resistance, reactance and temperature. Simulation results indicate the variation of HTS power cable condition. The results are used for the transient characteristic analysis and stability verification of the tri-axial HTS power cable. In the future, the RTDS-based model component of the cable will be used to implement the hardware-in-the-loop simulation with a protection device.

잠재적 폭발위험장소에서 내연기관에 의한 점화 위험성에 관한 연구 (Study of the Risk of Ignition due to Internal Combustion Engines in Areas with Potentially Explosive Gas Atmospheres)

  • 김윤석;이동호
    • 한국화재소방학회논문지
    • /
    • 제30권5호
    • /
    • pp.1-8
    • /
    • 2016
  • 국내외의 가연성 또는 인화성물질을 취급하는 대형설비에서의 폭발위험장소에 대한 안전관리는 기업의 지속가능경영과 신뢰를 바탕으로 한 지역사회와의 공존에 있어 매우 중요하다. 폭발위험장소의 안전관리는 크게 가연성 또는 인화성 물질의 누출을 제어하는 시스템과 이러한 가연성 또는 인화성물질이 누출되어 폭발분위기를 형성할 때 점화원을 제어함으로써 화재 또는 폭발사고로 전이되지 않도록 하는 방폭시스템이 있다. 제도와 기술로 인해 전기적 점화원에 대한 방폭설비는 상당히 보급되어 관리되고 있다. 하지만 열적 점화원의 경우, 위험성에 대한 인식과 관련 기술개발이 미흡하다. 본 연구는 잠재적 폭발위험장소에서 내연기관의 점화 위험을 보고하기 위하여 수행되었다. 이를 위하여 문헌조사를 통하여 관련 국제표준과 사고사례 및 위험분석보고서를 연구하고, 국내 중부권 공정안전관리제도 대상 사업장의 디젤엔진의 불꽃방지기 등 안전장치 적용실태를 조사하였다. 실제적으로 본 연구결과를 석유화학 산업에 적용함에 있어, 디젤엔진과 같은 내연기관 점화원의 위험인식을 통해 잠재적 폭발위험장소에서의 폭발방지에 대한 안전관리방안으로 활용 될 수 있을 것이다.

Characteristics of π-shaped Ultrasonic Motor

  • Lim Kee-Joe;Park Seong-Hee;Yun Yong-Jin;Park Cheol-Hyun;Kang Seong-Hwa;Lee Jong-Sub
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권2호
    • /
    • pp.241-245
    • /
    • 2006
  • In this paper, the design and characteristics of a $\pi-shaped$ ultrasonic motor that is applicable to optical zoom operation of a lens system for mobile phones are investigated. Its design and simulation of performances are carried out by FEM (finite element method) commercial software. As a simulation result, by applying voltage with single phase, a combined vibration is produced at the surface of a stator arm. A prototype of the motor is fabricated and its outer size is $8*4*2mm^3$ including the cylindrical steel rod of 2 mm in diameter as the rotor. The motor exhibits a maximum speed of 500 rpm and a power consumption of 0.3 W when driven at 20 Vpp and 64 kHz.

송전용 자기재 애자의 열화시험 평가기술 (Assessment Technique and Aging Test for EHV Porcelain Insulators)

  • 한세원;조한구;박기호;정길조;이동일;최인혁;신태우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.480-483
    • /
    • 2002
  • This paper through shift norm of insulator and research by accident prevention countermeasure special skill authoritativeness verification of insulator and Long Term aging factor for power transmission analysis and evaluate and prove quality of insulator wish to. Assessment technique by aging of own porcelain insulator observes ageing factor for reciprocity comparison through several examinations. Through cool and heat accelerated Aging test, can measure the leakage current change amount that ensue to each Cycle. Can confirm own blazing fire factor as distribution freshness that ensue in HRB Test's hardness value.

  • PDF