• 제목/요약/키워드: Electrical explosion method

검색결과 69건 처리시간 0.025초

몬테카를로 시뮬레이션을 이용한 직접부하제어의 제어지원금 산정 (Determination of Incentive Level of Direct Load Control using Monte Carlo Simulation with Variance Reduction Technique)

  • 정윤원;박종배;신중린;채명석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.666-670
    • /
    • 2004
  • This paper presents a new approach for determining an accurate incentive levels of Direct Load Control (DLC) program using sequential Monte Carlo Simulation (MCS) techniques. The economic analysis of DLC resources needs to identify the hourly-by-hourly expected energy-not-served resulting from the random outage characteristics of generators as well as to reflect the availability and duration of DLC resources, which results the computational explosion. Therefore, the conventional methods are based on the scenario approaches to reduce the computation time as well as to avoid the complexity of economic studies. In this paper, we have developed a new technique based on the sequential MCS to evaluate the required expected load control amount in each hour and to decide the incentive level satisfying the economic constraints. And also the proposed approach has been considered multi-state as well as two-state of the generating units. In addition, we have applied the variance reduction technique to enhance the efficiency of the simulation. To show the efficiency and effectiveness of the suggested method the numerical studies have been performed for the modified IEEE reliability test system.

  • PDF

수소연료전지 자동차용 고전압 배선 시스템 평가 기술 개발 (High Voltage Wiring System Evaluation Methode of FCEV (Fuel Cell Electric Vehicle))

  • 임지선;이정훈;이효정;나주란
    • 한국수소및신에너지학회논문집
    • /
    • 제23권4호
    • /
    • pp.330-336
    • /
    • 2012
  • FCEV uses 250 ~ 450 V instead of using 12 V battery. High voltage vehicle can cause electric shock, fire and explosion accident. Therefore, it has potential factors that can cause hazard of safety for users. United states of America and Europe legislate regulations such as ECE R100, FMVSS 305 for regulating electrical safety during driving or after collision. The company manufacturing high voltage components must do advanced R&D about Method for improving and confirming the safety of high voltage. We develop the specific hardware components of high voltage wiring system for the power train system and power supply system of Hyundai Motors FCEV. This paper shows test method of insulative performance for securing the electrical safety of high voltage components such as power cable, connectors and buss-bar, and proposals the guide line value for human safety of FCEV according to the test result of our development components.

Study of complex electrodeposited thin film with multi-layer graphene-coated metal nanoparticles

  • Cho, Young-Lae;Lee, Jung-woo;Park, Chan;Song, Young-il;Suh, Su-Jeong
    • Carbon letters
    • /
    • 제21권
    • /
    • pp.68-73
    • /
    • 2017
  • We have demonstrated the production of thin films containing multilayer graphene-coated copper nanoparticles (MGCNs) by a commercial electrodeposition method. The MGCNs were produced by electrical wire explosion, an easily applied technique for creating hybrid metal nanoparticles. The nanoparticles had average diameters of 10-120 nm and quasi-spherical morphologies. We made a complex-electrodeposited copper thin film (CETF) with a thickness of $4.8{\mu}m$ by adding 300 ppm MGCNs to the electrolyte solution and performing electrodeposition. We measured the electric properties and performed corrosion testing of the CETF. Raman spectroscopy was used to measure the bonding characteristics and estimate the number of layers in the graphene films. The resistivity of the bare-electrodeposited copper thin film (BETF) was $2.092{\times}10^{-6}{\Omega}{\cdot}cm$, and the resistivity of the CETF after the addition of 300 ppm MGCNs was decreased by 2% to ${\sim}2.049{\times}10^{-6}{\Omega}{\cdot}cm$. The corrosion resistance of the BETF was $9.306{\Omega}$, while that of the CETF was increased to 20.04 Ω. Therefore, the CETF with MGCNs can be used in interconnection circuits for printed circuit boards or semiconductor devices on the basis of its low resistivity and high corrosion resistance.

세관을 흐르는 절연유의 유동대전에 의한 대전전하의 제전방법에 관한 연구 (A Study on the new method of electrostatic elimination in oil flowing pipe.)

  • 소금실성;박재윤;이덕출;황명환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.129-131
    • /
    • 1990
  • When insulating oil is flowed through a pipe, the electrostatic charge in the oil will be increased. Using inflammability oil, an electrostatic phenomena which may cause significantly problems as explosion must be circumvented by some methods. In this paper we made a new electrode which was applied AC field to the flowing oil for reducing electrostatic charge. Before we developed the new method of an electrostatic elimination, the electrification experiment was performed by using the same electrode which was supplied DC voltage to realize electrified conditions. As a result of this study, the effect of the electrostatic elimination could be observed.

  • PDF

고상연소반응법에 의한 나노텅스텐분말의 합성 (Synthesis of nanometric tungsten powders by solid state combustion method)

  • ;이종현;원창환
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2003년도 추계학술발표강연 및 논문개요집
    • /
    • pp.93-93
    • /
    • 2003
  • Tungsten and tungsten heavy alloys have widespread application as radiation shielding devices and heavy duty electrical contacts. High density and good room temperature mechanical properties have generated interest in evaluating tungsten and tungsten alloys as kinetic energy penetrators against armor. Nowdays ultra fine-grained tungsten powders are in great interest because higly dense structures can be obtained at low temperature, pressure and lower sintering time. Several physical md chemical methods are available for the synthesis of nanometric metal Powders: ball milling, laser abalation, vapor condensation, chemical precipitation, metallic wire explosion i.e. However production rates of the above mentioned methods are low and further efforts are needed to find out large-scale synthesis methods. From this point of view solid state combustion method ( known as SHS) represents undoubted interest.

  • PDF

네트워크 전송을 위한 H.264 비디오의 효율적인 계층화 방법 (Efficient scalable method of H.264 video coding for network transport)

  • 황정택;박승호;서덕영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.192-194
    • /
    • 2005
  • Acceptance of the international standards for video compression, such as H.261, MPEG-1 and MPEG-2, along with the developments in video codec hardware, has created an explosion of application. Among these, the long time quest for long-distance digital video transmission causes an increasing interest in transporting compressed video over networks which are nontraditional for this purpose, including asynchronous transfer mode networks, the Internet, and cellular and wireless channels. Transmission of compression video over packet network is improved for error resilience. And layered video coding techniques improves error resilience. We present a efficient method of scalable video coding for low bandwidth.

  • PDF

인덕턴스 변화 모델을 이용한 EMGF 출력 분석 (EMGF Output Analysis Using Inductance Variation Model)

  • 김태신;성인모;양지혁;유천열;권오규
    • 한국자기학회지
    • /
    • 제19권1호
    • /
    • pp.5-11
    • /
    • 2009
  • Explosive Magnetic Generator of Frequency(EMGF)는 고폭화약의 폭발을 이용하여 화약의 폭발 에너지를 전자기 에너지로 변환 시키면서 초고주파의 강한 전자파를 발생시키는 효율적인 방법으로 연구되고 있다. 이 때 발생하는 전자파의 물리적 원인은 현재까지 명확하게 규명되어 있지 않은데, 단순한 시변 등가회로 해석만으로는 이러한 고주파 발진을 설명하기 어려운 것으로 알려져 있다. 이 논문에서는 기존에 널리 받아 들여 지고 있는 지수 감소적인 시변 인덕턴스 변화 모델에 대해서 자장압축효과를 고려한 유한요소 해석을 통해 문제점을 분석하고 보다 정확한 인덕턴스 변화 모델의 경향성에 대해서 제시하고자 한다. 그리고 이렇게 제시된 새로운 인덕턴스 변화 모델을 사용한 EMGF 출력 시뮬레이션을 통해 새로운 인덕턴스 변화 모델이 출력에 미치는 영향을 분석한다.

안전소자를 이용한 유도회로의 점화한계 개선에 관한 연구 (A Study on the Improved Ignition Limit for Inductive Circuits with Safety Components)

  • 이춘합;박민영;지승욱;김충년;이광식;심광렬
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.66-71
    • /
    • 2004
  • This paper describes that the improved effects on the ignition limit are studied by parallel safety components for propane-air 5.25vol.% mixture gas in low voltage inductive circuits. The experimental devices are used in the IEC type spark ignition test apparatus. The improved effects on the ignition limit are respectively obtained as the maximum rising rate of 650%, 1,080% by composing parallel circuits between inductance and safety components (condenser and diode) as compared with disconnecting inductance with the safety components. The more values of inductance the higher improved effects of ignition limit rise. This improving method for the ignition limit is not concerned with the safety components. Diode appears to effect greatly better than condenser. It is considered that the result can be used for not only data for researches and development of intrinsically safe explosion-proof machines which are applied equipment and detectors used in hazardous areas but also for data for its equipment tests.

다기능 방역 소독기 개발 (Development of Multi-function Disinfection Sterilizer)

  • 조현섭;박종선;이광련;유인호;정영석;김대성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2495-2496
    • /
    • 2002
  • Most of existing disinfection sterilizer had used mist method that burn chemicals and dust with them by putting chemicals in the course of explosion using gasoline. But, that method is not used because of environmental pollution, and spray method using a high-pressure pump is used in an advanced country. These method is very effective than existing mist method because the effect of chemicals can be appeared as it is when spray chemicals. This research will develop completely automatic multi-function disinfection sterilizer in the first at home that can be liberally used by oneself in order to alternate existing products need addition manpower and can be easily used at a place where sources of electricity is not by using gasoline engine to solve inconvenience by the use of electricity, and can be literally operated above and below, right and left in a driver's seat when is loaded in vehicles.

  • PDF

펄스파워를 이용한 수중 충격파 발생 및 응용 (Shock Wave Generation and its Applications by Pulsed Power)

  • 조주현;이흥식;최영욱;조성찬;정우근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.190-191
    • /
    • 2007
  • Focused shock wave generation was tested under the water by the method of wire explosion. The wire was installed a focal point of the half ellipsoid, and the shock wave was focused on the other focal point. A numerous cavitations were observed in the path of the traveling shock wave and focal point by using high speed camera.