• 제목/요약/키워드: Electrical equipment

검색결과 2,790건 처리시간 0.038초

조명기기의 임펄스내전압 성능의 분석 (Analysis of Impulse Withstand Voltage Performance of Lighting Equipment)

  • 이복희;방평호
    • 조명전기설비학회논문지
    • /
    • 제28권3호
    • /
    • pp.91-96
    • /
    • 2014
  • Modern electronic circuits are becoming more vulnerable to damage by surges, and it is required to improve the impulse withstand voltage performance of electrical and electronic equipment. This paper presents the impulse withstand voltage performance of lighting equipment connected to power lines, and the impulse withstand voltage tests for fluorescent lamp, LED lamp and halogen lamp were carried out according to the reference standards under normal service conditions. To conduct performance tests against lightning surge, a combination wave ($1.2/50{\mu}s$ voltage - $8/20{\mu}s$ current) was employed. The test surge was applied between lines or between line and ground of the specimen to be measured. The test surge was applied synchronized at the peak value of the positive and negative AC voltage waves. As a consequence, some specimens satisfied the impulse withstand voltage test criteria, but lighting equipment such as 36W fluorescent lamps, 5W and 5.5W LED lamps and 50W halogen lamp were damaged at the test voltage levels between power lines. It is needed to improve the qualities of lighting equipment to satisfy EMC immunity requirements of equipment for general lighting purposes.

Comparison of the RCA Between China and KOR: From the Perspective of Value-Added

  • Xiaosong Jiao;Yingqi Cao;Lily Jiao;Chandaith Neak;Yaqian Zhang
    • Journal of Korea Trade
    • /
    • 제26권4호
    • /
    • pp.23-38
    • /
    • 2022
  • Purpose - This paper empirically explores the RCA of electrical equipment trade between China and Korea from the perspective of gross trade and value-added trade. The goal of this paper is to scan the electrical equipment's RCA, the decomposition of gross exports, and the impacts of an exerted shock. Design/methodology - We applied the domestic value-added method in measuring the RCA, which could be more accurate than traditional RCA since it excludes foreign value-added. Based on the research purpose, this paper follows the framework of Koopman, Wang, and Wei (2014)-as extended by Wang, Wei, and Zhu (2018). It extracts the data from the 2019 Multi-regional Input-Output (MRIO) databases compiled by the Asian Development Bank in January 2021. Findings - After rigorous examination, the main findings are as follows: First, the electrical equipment sector maintains a consistent comparative advantage in either assessing method. Second, China exports more gross goods of electrical equipment to the world than South Korea does, but there is a trade deficit with Korea. Third, South Korea and P.R. China are the most significant bilateral partners of foreign value-added sourcing. Finally, it is surprising that there is a shock on electrical equipment; the partner's service, as well as manufacturing sectors, would be affected. Originality/value - This paper explores the revealed comparative advantage between Korea and China from traditional gross export and value-added perspectives. Second, we apply the information from the 2019 MRIO database compiled by the Asian Development Bank in January 2021, reflecting the current situation. Third, this paper analyzes the electrical equipment and the impacts on other parties' sectors. Finally, we carry out the subjects that deserve to be investigated in the future.

Effect of Particle Size and Dispersion on Dielectric Properties in ZnO/Epoxy Resin Composites

  • Yang, Wenhu;Yi, Ran;Yang, Xu;Xu, Man;Hui, Sisi;Cao, Xiaolong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권3호
    • /
    • pp.116-120
    • /
    • 2012
  • In this paper, ZnO-Epoxy nanocomposites (NEP) were prepared and epoxy composites that contain 5 wt% micro ZnO (MEP) and deliberately not well dispersed nano ZnO (NDNEP) were also prepared for purpose of comparison. The effects of the particle size and dispersion of ZnO on dielectric properties of epoxy resin were chiefly studied. Test results showed that: at a loading of 5 wt%, the three epoxy composites seem to have no significant difference on resistivity compared to epoxy resin; Dielectric constants of all the epoxy composites are also basically the same but they are bigger compared to that of the pure epoxy resin (unfilled); Dielectric dissipation factors ($tan{\delta}$) of NDNEP is greater than that of NEP and MEP. NEP has the minimum dielectric loss factor, whereas dielectric loss factors of the three epoxy composites are larger than that of the pure epoxy resin. The decreasing order of electrical breakdown strength for the three epoxy composites and for the pure epoxy resin is as follows: NEP>MEP>NDNEP>EP. Finally, in order to explain the experimental results the aggregation interface phase was proposed. Furthermore, addition of well dispersed nano filler has proved to have a positive effect on the improvement of the dielectric properties of epoxy resin.

식료품 제조업 전기설비의 설치환경에 따른 절연저항 변화 분석 (Analysis of Insulation Resistance Change according to the Installation Environment of Food Manufacturing Electrical Equipment)

  • 정연수;김두현;김성철
    • 한국안전학회지
    • /
    • 제38권1호
    • /
    • pp.34-41
    • /
    • 2023
  • In this study, S food manufacturing business located in Chungbuk was selected as the subject, and the transition in insulation resistance in major electrical equipment used in this food manufacturing business was analyzed for 4 years (2018-2021). It was confirmed that the insulation resistance decreased over time for all 18 electrical facilities. Insulation resistance changed due to environmental influences such as load characteristics and ambient temperature. Particularly in the case of the food manufacturing industry, it was confirmed that the decrease started after 2 years, although it varied depending on equipment and environmental influences. Furthermore, it was confirmed that management through predicting the management cycle of electrical equipment is possible by deriving a regression equation through regression analysis of insulation resistance measurement values.

철도용 전기기기의 고장요인 및 절연열화 분석 (Analysis of faust cause & insulation degradation on the electrical equipments for railway)

  • 왕종배;전한준;박옥정;온정근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.207-210
    • /
    • 2001
  • Electrical equipment for railway is always experiencing wear and degradation by mechanical, electrical and environmental stress in service and the fault or the accident of high voltage main circuit directly causes operation interruption. Particularly propulsion drive of high speed switching inverter takes the form of specific degradation mechanism such as fast rising transient surge, reflective overvoltage and harmonic stress, and it is known that it threatens the long life and the reliability of electrical equipment. In this paper, statistics of fault and accident on main electrical equipment for railway are presented and also insulation degradation mechanism, which governs end life of electrical device, is analyzed. Finally the method of fault respondence and reliability improvement on the main electrical equipments will be reviewed in order to prevent operation interruption.

  • PDF

공기압을 이용한 전기설비 침수 방지 장치 개발에 관한 연구 (The development for flooding prevention apparatus of electrical equipment using air pressure)

  • 김기현;전현재;이상익;배석명;이재용
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.281-284
    • /
    • 2008
  • Inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. In case inundation excluding the exchanging cost of equipment, it occurs a great economic and social loss owing to recovery time and events of electric shock occur by inundation electrical equipment(Pad-mounted Transformer and Switch). In case of installing the power equipment at flood danger territory, we are necessary to the product development, the product is that water does not come in the inside the power equipment. Product of pressure maintaining are established on the basic frame and sensor operates at the flooding occurrence and is maintained a shutting tightly structure and it is a method. The product which is produced the reliability of the product it confirmed a flooding yes or no from the condition which puts in the water tank and it verified. We estimate that loss cost which is caused by with flooding and the power failure will be diminished if it is addition to advances the reliability evaluation and a security of the flood protection product.

  • PDF

전기철도 차량기지 변전소의 실시간 무효전력/역률 보상설비 적용에 따른 전력품질 개선에 관한 연구 (A Study on Improving Power Quality by Real-time Reactive Power/Power Factor Compensating Equipment at Substation in Marshalling Yard)

  • 박수철;송중호
    • 조명전기설비학회논문지
    • /
    • 제20권10호
    • /
    • pp.58-67
    • /
    • 2006
  • 본 논문에서는 전기철도 차량기지 변전소의 전력품질을 개선하기 위한 실시간 무효전력/역률 보상설비를 제안하였으며 실제 차량기지에 적용하기 위한 최적의 용량을 제시하였다. 이를 위하여 현재 상용화된 여러 종류의 실시간 무효전력/역률 보상설비를 소개하였고 이 중에 전기철도 차량기지 변전소의 부하 특성에 가장 적합한 보상설비인 SVG(Static Var Generator)를 제시하였다. 제시된 SVG는 PSIM을 사용하여 간이 모의 시스템으로 구현되었으며 이를 통한 기본적인 보상원리와 모의 결과를 기술하였다. 실제 차량기지에 적용하기 위한 최적의 용량 설계는 실제 측정된 차량기지 변전소의 전력품질 데이터를 기초로 설계되어 졌으며 보상효과 및 경제적인 측면이 고려된 용량으로 제시되었다. 최종적으로 전압형 인버터와 직류 커패시터로 구성된 실시간 무효전력/역률 보상설비를 통한 실제 전기철도 차량기지 변전소의 전력품질 개선에 대하여도 기술되었다.

전자파를 이용한 폐쇄배전반내 전력기기의 열화 온라인 진단시스템 개발 (Development of on-line system using electromagnetic wave for diagnosis of deteriorated power equipment in enclosed switchboard)

  • 강창원;최길수;이영상;강대수;김재철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.178-181
    • /
    • 2001
  • This paper presents the development of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise. Power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector, and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

노후전력설비 교체에 따른 SCADA시스템의 운용 고찰 (Exchanging of old electrical equipment and discussion of SCADA system's operation related with exchanging of old electrical equipment)

  • 김윤식;박래혁;이기승
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.417-422
    • /
    • 2008
  • The DC high speed circuit breaker used in Seoul Metro for line no.1.2 is Japan HITACHI and FUJI breaker, and for line no.3.4 is Whipp & Bourne MM74 breaker from UK. The years that each breakers made are 1973(line no.1), 1984(line no.3.4), So that equipments are superannuated. Nowday the for equipment exchanging is executing, equipment for exchanging were used the Secheron breaker from Swiss. but now the Intec breaker made in Korea is used. The RTU of supervisory control and data acquisition system have the capabilities that can observe, control and work the installation efficiently. In this paper, as summarizing the solving process of problem that happened the SCADA system when old-equipment exchange and concerned point for logical supervision and control of reservation factors and equipment, I'll provide the direction that can do receiving-process of control-equipment, progressed with the exchange of old-electronic equipment.

  • PDF