The analysis of inductive contactless inductive power transformer used for the PRT(Personal Rapid Transit) system (소형궤도 차량 시스템에 적합한 무접촉 유도 전력 변환 장치의 특성해석)

  • Han, K.H.;Lee, B.S.;Byun, Y.S.;Baek, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.218-220
    • /
    • 2004
  • In this paper, the concept of contactless inductive power transfer system used for the PRT system is suggested and some ideas for Power transformer design to improve the power transfer performance are presented. This system has a large air-gap and demands a large electrical power capability But, low output power is generated due to a loosely coupled characteristic of the large air-gap. Therefore, double layer construction of secondary winding, which was divided in half to increase both output current and output voltage was suggested. In addition, the performance of power transformer alignment condition between the primary power line and the power collector was verified by computer simulation of 2kW model.

  • PDF

Magnetic Field Reduction Characteristics of Shielding Wear Materials for Workers Using AC Arc Welder (교류 아크용접기를 사용하는 작업자의 차폐복 재질에 따른 자계저감 특성검토)

  • Park, Jun-Hyeong;Min, Suk-Won;Lee, Seung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.7
    • /
    • pp.1265-1271
    • /
    • 2010
  • Power cable of an AC arc welder can surround a body of worker at the moment of welding. Applying the boundary element method, we calculated current densities induced in organs inside a worker to study the magnetic field reduction characteristics of shielding wear materials. We knew shielding wear with high permeability materials lowers current density more than high conductivity materials. We also found current density was lowest when high permeability materials were inside high conductivity materials in double layer shielding wear.

Monte Carlo Simulation of Thermionic Low Pressure Discharge Plasma (저압 열전자 방전 플라즈마의 Monte Carlo 시뮬레이션)

  • Koh, Wook Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1880-1885
    • /
    • 2012
  • Nonlinear dynamical behaviors in thermionic low pressure discharge are investigated using a particle-in-cell(PIC) simulation. An electrostatic PIC code is developed to model the plasma discharge system including the kinetic effects. The elastic collision, excitation collision, ionization collision, and electron-ion recombination collision are considered in this code. The generated electrons and ions are traced to analyze physical characteristics of the plasma. The simulation results show that the nonlinear oscillation structures are observed for cold plasma in the system and the similar structures are observed for warm plasma with a shift in values of the bifurcation parameter. The detailed oscillation process can be subdivided into three distinct mode; anode-glow, temperature-limited, and double-layer modes.

Development of Dynamic Voltage Restorer System Considering Characteristics of EDLC (EDLC의 특성을 고려한 동적전압보상시스템의 개발)

  • Lee, Sang-Cheol;Seo, Il-Dong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.3
    • /
    • pp.288-292
    • /
    • 2010
  • Recently, in energy storage system, the EDLC is paid attention as a new environmentally friendly energy storage element. This capacitor has higher energy density than the electrolytic capacitor. Also, this capacitor has a lot of advantage such as no maintenance, longer life cycle and faster charge-discharge time than the battery system. But the EDLC must have a each charge-discharge controller to effectively control, an energy design method circuit to use effectively energy, and several compensation techniques to control a optimal operating. In this respect, this study suggests major parameters to effectively represent the characteristics of EDLC, the measurement methods of those parameters have been investigated with experiments, and the interpretation about the buck/boost DC/DC converter for the operation of EDLC.

Determination of the HESS Capacity for Mitigation of Fluctuation of Wind Farm Output under Consideration of Disconnecting Wind Farm (풍력발전단지 탈락 시를 고려한 단지 출력 변동 저감을 위한 HESS의 용량 산정)

  • Kim, SeongHyun;Ko, JiHan;Kim, Eel-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.388-389
    • /
    • 2013
  • This paper presents the method for the fluctuation smoothing control by using relaxation time variable control of battery. When the output power of wind farm is changed suddenly, it is necessary to control the output power of wind farm. The smoothing relaxation time is changed within limits of battery output power. Using the hybrid energy storage system (HESS) combined with battery energy storage system and electric double layer capacitor, it is possible to control the output power of wind farm. The capacity of battery is determined by considering the case of the disconnecting wind farm from the grid. To verify the proposed method, simulations are carried out by using PSCAD/EMTDC with actual data of wind farm in the Jeju Island.

  • PDF

The Modeling of inductive power collector for light railway system (소형궤도차량 시스템에 적합한 유도전력 집전 장치의 모델링)

  • Han, K.H.;Lee, B.S.;Baek, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.215-217
    • /
    • 2005
  • In this paper, the inductive power collector using electromagnetic induction for the PRT{Personal Rapid Transit) system is suggested and some ideas for power collector design to improve the power transfer performance are presented. The proposed the inductive power collector is used for the PRT system, which has a large air-gap and demands a large electrical power capability. But, low output power is generated due to a loosely coupled characteristic of the large air-gap. Therefore, double layer construction of secondary winding, which was divided in half to increase both output current and output voltage was suggested. Also, model of power collector and parallel winding structure are presented, in addition, the performance of inductive power collector to alignment condition between the primary power line and the inductive power transformer was verified by computer simulation of 2kW model.

  • PDF

On-Line Type Dynamic Voltage Restorer System by Improvement of EDLC's energy utilization ratio (EDLC의 Energy이용 향상에 의한 On-Line type Dynamic Voltage Restorer System)

  • Shon, Jin-Geun;Park, Jong-Chan;Seo, Il-Dong;Jeon, Hee-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1099-1101
    • /
    • 2007
  • In this paper, a study has been performed for development of dynamic voltage restorer(DVR) system using EDLC (Electric Double Layer Capacitor) to solve voltage sags which are considered the dominant disturbances affecting power quality. With the prolific use of semiconductor devices in electrical equipment, modern-day loads are becoming increasingly sensitive to the sags and the disturbances prove to be costly to industries. As a technology-driven custom power installation, the Dynamic Voltage Restorer (DVR) is recognized to be most effective equipment that can be used to counter the voltage sag problem. Hence, this paper proposes the high-performance optimal design of On-Line type DVR system which can efficiently compensate the instantaneous voltage sag and instantaneous interruption of the utility voltage source.

  • PDF

Electrochemical Properties of Electric Double Layer Capacitor with PolyanilineComposite (Polyaniline Composite 전극을 사용한 전기 이중층 캐패시터의 전기화학적 특성)

  • 강광우;김종욱;구할본
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.370-373
    • /
    • 1999
  • The purpose of this study is to research and develop PAn composite electrode for EDLC. EDLC cell of PAn composite electrode with 1M LiClO$_4$/PC brings out good capacitor performance below 4.0V. The radius of semicircle of PAn composite electrode adding 15wt% SP270 was absolutely small. The total resistance of EDLC cell mainly depended on internal resistance of the electrode. The discharge capacitance of PAn composite with 15wt% SP270 in 1st and 200th cycles was 42 and 42 F/g at current density of 1mA/cm$^2$. The capacitance of PAn composite with 15wt%. SP270 capacitor was larger than that of PAn capacitor without SP270. The coulombic efficiency of EDLC at discharge process of 1 and 200 cycles were 94 and 100% respectively. PAn composite EDLC with 15wt% SP270 content showed good capacitance and stability with cycling.

  • PDF

The photoinduced anisotrophy(PA) by Ag polarized-photodoping in amorphous chalcogenide thin films (Ag 편광 광도핑에 의한 칼코게나이드 박막의 광유기 이방성(PA))

  • 장선주;여철호;박정일;정홍배;이천용
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.574-577
    • /
    • 1999
  • The chalcogenide glasses of thin films have superior property of the photoinduced anisotrophy(PA). In this study, we observed the phenomenon of Ag polarized photodoping using the irradiation with polarized He-Ne laser light, in the thin film of chalcogenide As/sub 40//Ge/sub 10//Se/sub 15//S/sub 35/ and the double-layer of Ag doped As/sub 40//Ge/sub 10//Se/sub 15//S/sub 35/. The Ag polarized photodoping result in reducing time of saturation anisotrophy and increasing sensitivity of linearly anisotrophy intensity, up to maximum 220%. In the thin films of chalcogenide, the Ag polarized photodoping will be show a capability of new method that suggested more improvement of photoinduced anisotrophy property

  • PDF

Equivalent-Circuit Analysis of Organic Light-Emitting Diodes in $ITO/TPD/Alq_3/Al$ ($ITO/TPD/Alq_3/Al$ 유기발광소자의 등가회로 분석)

  • Ahn, Joon-Ho;Oh, Yong-Chul;Hong, Jin-Woong;Lee, Joon-Ung;Song, Min-Jong;Kim, Tae-Wan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.188-191
    • /
    • 2004
  • We have investigated equivalent-circuit analysis of organic light-emitting diodes in $ITO/TPD/Alq_3/Al$. Complex impedance Z of the device was measured in the frequency range of $40Hz{\sim}1MHz$. We are able to interpret the frequency-dependent response in terms of equivalent-circuit model of contact resistance $R_s$ in series with two parallel combination of $R_{TPD},\;C_{TPD}\;and\;R_{Alq3},\;C_{Alq3}$.

  • PDF