• 제목/요약/키워드: Electrical distribution network

검색결과 609건 처리시간 0.024초

능동위상제어기를 이용한 배전선로 자율 재구성 시 순환전류 감소 기법 (Circulating Current Reduction Method during Distribution Network Dynamic Reconfiguration using Active Phase Controller)

  • 김수연;정다움;박성준;김동희
    • 전력전자학회논문지
    • /
    • 제25권1호
    • /
    • pp.6-12
    • /
    • 2020
  • In recent years, the demand for the distribution of energy resource has been increasing. However, the output power is limited by the stability of the distribution network. This study proposes an active distribution network that can reconfigure the distribution line using an active phase controller. The conventional distribution network has a fixed structure, whereas the proposed active distribution network has a variable structure. Therefore, the active distribution network can increase the output power of the distribution energy resource and reduce the overload of distribution line facilities. The active phase controller has two operation modes to minimize the circulating current during dynamic reconfiguration. In this study, the voltage and current control algorithms are proposed for the active phase controller. The proposed method for the active phase controller is simulated via PSIM simulation.

Feeder Loop Line Control for the Voltage Stabilization of Distribution Network with Distributed Generators

  • Jeong, Bong-Sang;Chun, Yeong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.1-5
    • /
    • 2014
  • When renewable sources are connected to the distribution network in the form of a distributed generators(DGs), the effect of intermittent output appears as voltage fluctuation. The surplus power at the consumer ends results in the reverse power flow to the distribution network. This reverse power flow causes several problems to the distribution network such as overvoltage. Application of the reactive power control equipment and power flow control by means of BTB inverter have been suggested as the general solutions to overcome the overvoltage, but they are not economically feasible since they require high cost devices. Herein, we suggest the feeder loop line switch control method to solve the problem.

배전선로 재구성을 위한 능동위상제어기의 용량 선정 연구 (Study on Capacity Design of Active Phase Controller for Distribution Line Reconfiguration)

  • 정다움;김수연;박성준;김동희
    • 전력전자학회논문지
    • /
    • 제25권5호
    • /
    • pp.369-375
    • /
    • 2020
  • Distribution energy resources have been increasing in recent years. However, output power is limited for distribution network stability. This study proposes an active distribution network that can reconfigure distribution lines by using an active phase controller. A conventional distribution network has a fixed structure, whereas an active distribution network has a variable structure. Therefore, the latter can increase the output power of distribution energy resources and decrease the overload of distribution line facilities. An active phase controller has two operation modes for minimizing circulating current during dynamic reconfiguration. In this study, voltage and current control algorithms are proposed for active phase controllers. The simulation of the proposed methods for active phase controllers is performed using PSIM software.

Integrating Operation of Dispersed Generation to Automation Distribution Center for Distribution Network Reconfiguration

  • Park, Joon-Ho;Kim, Jae-Chul;Moon, Seung-Il
    • KIEE International Transactions on Power Engineering
    • /
    • 제2A권3호
    • /
    • pp.102-108
    • /
    • 2002
  • Due to the many attractive aspects of DG in the future power distribution system, distribution automation will be a center hub of integration of the distribution system and resources to satisfy the various needs of customers in a competitive and deregulated environment. In this paper, operation strategies are presented which use network reconfiguration of the automated distribution systems with DG as a real-time operation tool for loss reduction and service restoration from the view of distribution operation. The algorithms and operation strategies of an automated distribution system with DG are introduced to achieve the positive effects of DG in distribution systems. A simple case study shows the effectiveness of the proposed operation strategies.

분산전원 투입을 고려한 배전망 이용요금 산정에 관한 연구 (Calculation of Distribution Network Charging for DG Embedded Distribution System)

  • 황석현;김문겸;박종근
    • 전기학회논문지
    • /
    • 제61권4호
    • /
    • pp.513-521
    • /
    • 2012
  • With the advent of smart grid, distribution network charges have been one of keystones of ongoing deregulation and privatization in power industries. This paper proposes a new charging methodology to allocate the existing distribution network cost with an aim of reflecting the true cost and benefit of network customers, especially of distribution generator (DG). The proposed charging methodology separates distribution network costs due to the respective real and reactive power flows. The costs are then allocated to network users according to each charge for the actual line capacity used and available capacity. This distribution network charging model is able to provide the economic signals to reward network users who are contributing to better power factors, while penalizing customers who worsen power factors. The proposed method is shown on IEEE 37 bus system for distribution network, and then the results are validated through the comparison with the MW-Miles and MVA-Miles methods. The charges derived from the proposed method can provide appropriate incentives/penalties to network customers to behave in a manner leading to a better network condition.

Active Distribution Network Expansion Planning Considering Distributed Generation Integration and Network Reconfiguration

  • Xing, Haijun;Hong, Shaoyun;Sun, Xin
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.540-549
    • /
    • 2018
  • This paper proposes the method of active distribution network expansion planning considering distributed generation integration and distribution network reconfiguration. The distribution network reconfiguration is taken as the expansion planning alternative with zero investment cost of the branches. During the process of the reconfiguration in expansion planning, all the branches are taken as the alternative branches. The objective is to minimize the total costs of the distribution network in the planning period. The expansion alternatives such as active management, new lines, new substations, substation expansion and Distributed Generation (DG) installation are considered. Distribution network reconfiguration is a complex mixed-integer nonlinear programming problem, with integration of DGs and active managements, the active distribution network expansion planning considering distribution network reconfiguration becomes much more complex. This paper converts the dual-level expansion model to Second-Order Cone Programming (SOCP) model, which can be solved with commercial solver GUROBI. The proposed model and method are tested on the modified IEEE 33-bus system and Portugal 54-bus system.

An Autonomous Optimal Coordination Scheme in a Protection System of a Power Distribution Network by using a Multi-Agent Concept

  • Hyun, Seung-Ho;Min, Byung-Woon;Jung, Kwang-Ho;Lee, Seung-Jae;Park, Myeon-Song;Kang, Sang-Hee
    • KIEE International Transactions on Power Engineering
    • /
    • 제2A권3호
    • /
    • pp.89-94
    • /
    • 2002
  • In this paper, a protection system using a Multi-Agent concept for power distribution networks is proposed. Every digital over current relay(OCR) is developed as an agent by adding its own intelligence, self-tuning and communication ability. The main advantage of the Multi-Agent concept is that a group of agents work together to achieve a global goal which is beyond the ability of each individual agent. In order to cope with frequent changes in the network operation condition and faults, an OCR agent, suggested in this paper, is able to detect a fault or a change in the network and find its optimal parameters for protection in an autonomous manner considering information of the whole network obtained by communication between other agents. Through this kind of coordination and information exchanges, not only a local but also a global protective scheme is completed. Simulations in a simple distribution network show the effectiveness of the suggested protection system.

풍력발전단지의 계통연계 운전이 배전선 보호계전에 미치는 영향 (Influence of the Interconnected Wind farm on Protection for Distribution Networks)

  • 장성일;김광호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권3호
    • /
    • pp.151-157
    • /
    • 2003
  • Wind farm interconnected with grid can supply the power into a power network not only the normal conditions, but also the fault conditions of distribution network. If the fault happened in the distribution power line with wind fm, the fault current level measured in a relaying point might be lower than that of distribution network without wind turbine generator due to the contribution of wind farm. Consequently, it may be difficult to detect the fault happened in the distribution network connected with wind generator This paper describes the effect of the interconnected wind turbine generators on protective relaying of distribution power lines and detection of the fault occurred in a power line network. Simulation results shows that the current level of fault happened in the power line with wind farm depends on the fault impedance, the fault location. the output of wind farm. and the load condition of distribution network.

신뢰도 지수를 고려한 계통의 Neural-Tabu 알고리즘을 이용한 최적 전송 경로 결정 (Neural-Tabu algorithm in optimal routing considering reliability indices)

  • 신동준;정현수;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1245-1247
    • /
    • 1999
  • This paper describes the optimal reconfiguration of distribution network. The optimal routing of distribution network should provide electricity to customers with quality, and this paper shows that optimal routing of distribution network can be obtained by Neural-Tabu algorithm while keeping constraints such as line power capacity, voltage drop and reliability indices. The Neural-Tabu algorithm is a Tabu algorithm combined with Neural network to find neighborhood solutions. This paper shows that not only the loss cost but also the reliability cost should be considered in distribution network reconfiguration to achieve the optimal routing.

  • PDF

Power Flow Algorithm for Weakly Meshed Distribution Network with Distributed Generation Based on Loop-analysis in Different Load Models

  • Su, Hongsheng;Zhang, Zezhong
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.608-619
    • /
    • 2018
  • As distributed generation (DG) is connected to grid, there is new node-type occurring in distribution network. An efficient algorithm is proposed in this paper to calculate power flow for weakly meshed distribution network with DGs in different load models. The algorithm respectively establishes mathematical models focusing on the wind power, photovoltaic cell, fuel cell, and gas turbine, wherein the different DGs are respectively equivalent to PQ, PI, PQ (V) and PV node-type. When dealing with PV node, the algorithm adopts reactive power compensation device to correct power, and the reactive power allocation principle is proposed to determine reactive power initial value to improve convergence of the algorithm. In addition, when dealing with the weakly meshed network, the proposed algorithm, which builds path matrix based on loop-analysis and establishes incident matrix of node voltage and injection current, possesses good convergence and strong ability to process the loops. The simulation results in IEEE33 and PG&G69 node distribution networks show that with increase of the number of loops, the algorithm's iteration times will decrease, and its convergence performance is stronger. Clearly, it can be effectively used to solve the problem of power flow calculation for weakly meshed distribution network containing different DGs.