• Title/Summary/Keyword: Electrical conductivity(EC)

Search Result 385, Processing Time 0.032 seconds

A Laboratory Study on the Estimation of Water Requirements for the Desalinization of Reclaimed Tidelands (간척지토양의 제염용수량산정에 관한 실험연구)

  • 구자웅;한강원;은종호
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.31 no.1
    • /
    • pp.96-105
    • /
    • 1989
  • This laboratory study was performed to produce basic data for the estimation of water requirements for desalinization, through analyzing changes of the electrical conductivity and the exchangeable sodium percentage during the desalinization of reclaimed tidelands. Desalinization experiments were carried out by two water management practices, namely, the leaching method by subsurface drainage and the rinsing method by surface drainage, using samples of silt loam soil and silty clay loam soil collected in reclaimed tidelands. The results obtained from this study were summarized as follows : 1. The sample soils used in this study were saline-sodic soils with the high electrical conductivity and the high exchangeable sodium percentage. 2. Changes of the electrical conductivity and the exchangeable sodium percentage with water requirements for desalinization showed a similar tendency in the desalinization experiment by the same water management practice. 3. The regression equation between the relative electrical conductivity(EC/EC) and water requirements for desalinization(Dw/Ds) could be described by Dw/Ds=O. 29x(EC/EC.) -0.982 (Leaching method), Dw/Ds=3. 678X0. 030(EC/EC ) (Rinsing method). 4. The regression equation between the relative exchangeable sodium percentage (ESP/ESP ) and water requirements for desalinization (Dw/Ds) could be expressed in Dw/Ds = 0.039 x (ESP/ESP. ) - 1. 134 (Leaching method), Dw/Ds=7. 197X0. 024(ESP/ESP ) (Rinsing method). 5. It was estimated that water requirements for the adequate desalinization would be Dw/Ds=0.3 (Leaching method) and Dw/Ds=3.0 (Rinsing method)

  • PDF

Studies on the Diagnosis of Subclinical Mastitis in Cows by the Measurement of the Electrical Conductivity: 1. Comparison of Various Methods of Handling Conductivity Data with the Use of California Mastitis Test and Direct Somatic Cell Count (전기전도도(電氣傳導度) 측정(測定)에 의한 유우(乳牛) 준임상형(準臨床型) 유방염(乳房炎)의 진단(診斷)에 관한 연구(硏究) 1. 전기전도도법(電氣傳導度法)과 간접검진법(間接檢診法)(CMT 및 총체세포수(總體細胞數))과의 비교(比較))

  • Kang, Byong-kyu
    • Korean Journal of Veterinary Research
    • /
    • v.24 no.1
    • /
    • pp.91-98
    • /
    • 1984
  • A total of 466 foremilk from dairy farms in Chonnam district was examined for the subclinical mastitis over a period of one year, using a method of the electrical conductivities(EC); absolute conductivity(AC) and differential conductivity(DC) and quarter difference value(QD), in relation to the California mastitis test(CMT) and the direct somatic cell count(DSCC). The compatibility and efficiency rating between the EC values and the other screening tests was conducted. Obtained results are summarized as follows. 1. A linear relationship was found between the EC values and the CMT scores and direct somatic cell counts and it was found that electrical conductivity measurements were comparable with other screening tests for diagnosing animals with mastitis. 2. Compatibilities between the EC and CMT were 70.4% in AC, 74.6% in DC and 70.7% in QD, and that of the EC and DSCC were 53.0% in AC, 63.1% in DC and 53.2% in QD. On the other hand, relative efficiency ratings of Postle's equation between EC and CMT were 37.3% in AC, 26.5% in DC and 13.6% in QD, and that of the EC and DSCC were 33.1% in AC, 20.2% in DC and 11.9% in QD. 3. In the foremilk samples collected from damaged quarters determined by EC, the false positive rate wart higher than the false negative rate, and consequently tests of EC produced lower compatibility or efficiency rating scores. These tendencies suggested that any factors other than the mastitic condition influencing the EC values might be existed.

  • PDF

The Chemical Properties of Plastic-house Soil and Yield Responses of Green Pepper (꽈리풋고추 하우스 재배지토양의 화학적 특성과 수량반응)

  • Ryu, In-Soo;Lee, In-Hack;Hwang, Seon-Woong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.28 no.3
    • /
    • pp.241-248
    • /
    • 1995
  • This experiment was conducted to obtain basic information for the management of soil and fertilization for plastic-house soil cultivated Khwari green pepper in Dang Jin area of Chung Nam Province. The range of pH with highest frequency for 36 sites investigated was 6.1~6.5, OM 1.6~2.5%, available phosphorous 601~800mg/kg, CEC 12.1~14.0 c mol/kg, clay 16.1~18.0% and below 2.0ds/m for electical conductivity of soil. Fesh fruit weight of green pepper showed very high significant positive correlation with organic matter, clay content and cation exchange capacity, while negaive correlation with electrical conductivity. Electrical conductivity showed highly significant negative correlation with CEC, clay content and organic matter in soil, respectively. To decrease below 2.0 dS/m of electrical conductivity in plastic-house soil, the content of clay and organic matter could be maintained at above 1.8% and 2.3%, respectively.

  • PDF

Some Consideration of Groundwater Quality Characteristics in Nakdong River Region - Analysis of Correlation between Electrical Conductivity(EC) and Total Dissolved Solid(TDS) - (낙동강권역 지하수 수질 특성 고찰 - 전기전도도와 총고용물 함량의 상관성 분석을 중심으로 -)

  • 김형수;원이정;박희열
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.40-43
    • /
    • 2000
  • Groundwater qualities in Nakdong river region were investigated during 1999 and 2000. Groundwater samples were collected twice from about 150 sites over the region. The EC and TDS obtained in first survey (October, 1999) show rather high values than those in second survey(April, 2000) and this seems to be caused by groundwater temperature. There is obvious positive correlation between EC and TDS. For the study area, the following equation can be written : TDS(mg/l) = <0.64~0.70> x EC($mutextrm{s}$/cm). As the concentration of major ions increases in natural condition, there is a tendency that the ratio of TDS and EC has consistent value. This observation suggests that TDS measurement can be replaced by EC measurement in the some ranges.

  • PDF

Calculation of Bulk and Solution Electrical Conductivity of Soil Using Time Domain Reflectometry Measurements (TDR을 이용한 토양 총전기전도도 및 용액전기전도도 측정)

  • Bae, Byung-Sul;Choi, Woo-Jung;Han, Gwang-Hyun;Han, Kyung-Hwa;Yoo, Sun-Ho;Ro, Hee-Myong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.36 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • Time domain reflectometry (TDR) is a newly developed method for measuring simultaneously solute concentrations and volumetric water content of soil. Bulk electrical conductivity ($EC_a$) of soil is obtained from TDR signal using several equations proposed, and electrical conductivity of soil solution ($EC_w$) can be calculated using the linear relationship $EC_a=EC_w\theta(a\theta+b)+EC_s$ between $EC_a$ and $EC_w$ at constant soil water content. The objectives of this study were to evaluate $EC_a$ proposed by several workers and to obtain the empirical constants (a, b, and $EC_s$) for $EC_w$ of the soils from A, Bl, and B2 horizon of an agricultural field (Coarse loamy, Fluvaquentic Eutrudepts). The $EC_a$ proposed by Yanuka et al. responded most sensitively to the KCl solute concentrations. The empirical constants of a, b, and $EC_s$ for $EC_w$ were -0.249, 1.358, and 0.054 for A horizon, -2.518, 2.708, and 0.097 for Bl horizon, and 2.490, -0.250, and 0.103 for B2 horizon, respectively. Therefore, the results of this study showed that Yanuka et al. equation was most useful one in determining $EC_a$, from TDR signal for agricultural soil with low salinity and that the empirical constants for the calculation of $EC_w$, from $EC_a$ can be obtained through a simple calibration experiment.

Effect of Plant-Growth-Promoting-Bacterial Inoculation on the Growth and Yield of Red Pepper(Capsicum annuum L.) with Different Soil Electrical Conductivity Level (염류수준별 고추 생육과 수량에 미치는 식물생육보진미생물(植物生育保進微生物) 접종효과)

  • Lee, Young-Han;Yang, Min-Suk;Yun, Han-Dae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.29 no.4
    • /
    • pp.396-402
    • /
    • 1996
  • This study was conducted to determine the effect of treatment with the plant-growth-promoting bacteria on the growth and yield of red pepper(Capsicum annuum L.) with different soil electrical conductivity(EC) levels. The mixed liquid culture was done pseudomonas P and saboraud dextrose medium. The isolated bacteria(IB) were inoculated by spray of 3.7ml at 1/2000a pot filled with different soil electrical conductivity level(2.9, 8.6, 11.5dS/m) every week, respectively, with mixed liquid culture (Pseudomonas P+Sabouraud dextrose) of eight strains. The plant height of red pepper with IBs treatment in different soil EC levels showed better growth than IBs nontreatment in the order of the 2.9>8.6>11.5 dS/m. The yield of pepper with IBs treatment in different soil EC level was higher in 13% than IBs nontreatment and chemical properties($P_2O_5$, K, Ca, Mg) of the soil after harvest in IBs treatment were slightly increased, while organic matter and EC of IBs treatment were slightly decreased than those of IBs nontreatment. Moisture content of the soil after the harvesting with IBs treatment was slightly increased than IBs nontreatment.

  • PDF

Studios on the Diagnosis of Subclinical Mastitis in Dairy Cows by the Measurement of the Electrical Conductivity 2. Factors Influencing Electrical Conductivity Value (전기전도도측정에 의한 유우준임상형 유방염의 진단에 관한 연구 2. 전기전도도치의 변동요인)

  • Kang Byong-Kyu;Shin Chong-Bong
    • Journal of Veterinary Clinics
    • /
    • v.2 no.1
    • /
    • pp.115-120
    • /
    • 1985
  • To probe the subclinical mastitis in a herd of cows in Chonnam district, the electrical conductivity(EC) of 825 foremilk samples were measured for 2 years. Normal (n=487) and mastitic(n=110) foremilk samples were classified by the California mastitis test (CMT) and direct somatic cell count(DSCC) and investigated the relations between the changes of the EC value and the calving history, age, days of postpartum, estrus and causative organism isolated. Obtained results are summarized as follows. 1. In the normal foremilk samples, positive correlation, though not significant, was found between the EC value and calving history (r=0.573) and age (r=0.247). 2. In the normal foremilk samples, the EC values were lowered at 30~120 days of postpartum through the whole lactation period and revealed a tendencies to higher values following the day of postpartum increased untill to the drying off (r=0.823), and the days of postpartum was recognized as one of a influencing factor on the EC value(p<0.05). 3. In the mastitic foremilk samples, significant correlation between EC value and resazurin reduction test (RRT) were observed (r=0.904, p<0.05). 4. In the mastitic foremilk samples, EC values were obtained in the E. coli infection as 63.9mM-NaCl, in the Streptococcus spp. infection as 60.5mM-NaCl and in the Staphylococcus spp. infection as 57.0mM-NaCl. 5. At day 0 of estrus, the mean EC values of normal and mastitic foremilk samples were 41.2mM-NaCl and 68.3mM-NaCl respectively and the EC value of day 0 of estrus was higher than that of days before and after estrus.

  • PDF

The Flow rate estimation of CSOs using EC Data (전기전도도를 이용한 CSO의 유량 추정)

  • Choi, Weon-Suk;Song, Chang-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.751-757
    • /
    • 2011
  • The monitoring technique based on electrical conductivity (EC) can provide researchers with some advantages in maintenance management and is cost-effective as compared with existing CSOs monitoring. In this study, the flow rate estimation using EC data was executed in two sites where storm overflow chamber had installed. In the result of A-site, R2 of second order multinomial between dilution ratio of EC and observed flow rate was showed the range of 0.68 ~ 0.77. And $R^{2}$ of B-site was 0.62 ~ 0.81. On the other hand, cumulative frequency of A-site was 43.4 ~ 52.2% in the relative error level of under 20%. And B-site was 10.1 ~ 46.5%. The flow rate estimation formula was improved through consideration of some parameters including antecedent dry days and rainfall duration. And difference between estimated flow rate and observed flow rate in total rainfall event was very small.

Conductivity and Electrochemical characterization of Lithium ion secondary battery electrolytes (리튬이온 2차 전지용 전해액의 이온전도도와 전기화학적 특성)

  • 임동규;이제혁;변문기;조봉희;김영호;우병원;나두찬
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.295-298
    • /
    • 1998
  • We have investigated ionic conductivity and electrochemical stability of the electrolytes containing organic solvent. Ion conductivities were measured between 10 and 80$^{\circ}C$, and electrochemical stabilities were determined by cyclic voltammetry on glassy carbon, platinum and aluminum electrodes. Ionic conductivity of electrolyte(EC:DEC=1:1) with IM LiPF$\_$6/ shows better than that of the other electrolytes having Li salts. The IM LiBF$_4$-PC electrolyte exhibits good electrochemical stability. IM LiPF$\_$6/ (EC:DEC=1:1) and IM LiPF$\_$6/ (EC:DMC=1:1) electrolytes are used for the high capacity of battery system.

  • PDF

Ion Conduction Properties of PVDF based Polymer Electrolyte as a function of a Mixed Ratio (PVDF계 고분자 전해질의 혼합비에 따른 이온 전도 특성)

  • 김종욱;송희웅;구할본;이경섭
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.121-124
    • /
    • 1998
  • The purpose of this study is to research and develop solid polymer electrolyte(SPE) for Li secondary battery. This paper describes temperature dependence of conductivity, impedance spectroscopy, electrochemical properties of PVDF electrolytes as a function of a mixed ratio. Polyvinylidene(PVDF) based polymer electrolyte films were prepared by thermal gellification method of preweighed PVDF, plasticizer and Li salt. The conductivity of PVDF electrolytes was 10$\^$-3/S/cm. 25PVDFPC$\_$10/EC$\_$10/LiClO$_4$ electrolyte shows the better conductivity of the others. 25PVDFPC$\_$10/EC$\_$10/LiClO$_4$electrolyte remains stable up to 4.7V vs. Li/Li$\^$+/. Steady state current method and ac impedance used for the determination of transference numbers in PVDFD electrolyte film. The transference number of 25PVDFPC$\_$10/EC$\_$10/LiClO$_4$electrolyte is 0.58.

  • PDF