  • The electrical and mechanical properties of dielectric paper and cable at cryogenic temperature have been investigated to optimum insulating design of high-Tc superconducting(HTS) cable. From the results, Tensile strength of PPLP in liquid nitrogen was high more than that of air, but tensile strain could know that decrease sharply. According as tensile strength increases, the breakdown stress of PPLP in liquid nitrogen was decreased because PPLP was degradated. According as bending radius multiple is decrese, breakdown voltage decreased sharply. And bending radius multiple is thought that more than about 25 is suitable.

  • PDF

광유의 절연파괴에 미치는 전극간격 및 침전극 곡률반경의 영향 (The Effects of Gap Length and Tip Radius Influenced in Breakdown of Mineral Based Insulating Oil)

  • 이종섭;신태수;이운용;박영국;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.254-257
    • /
    • 1997
  • In this paper, we investigated the effects of gap length and tip radius influenced in breakdown of mineral based insulation oil Electrode system was needle-plane geometry It is to model conductive extrusions in oil filled electrical power apparatus. The tip radius of needle electrode was 5, 10, 20 and 25${\mu}{\textrm}{m}$, respectively. We measured breakdown voltage for each of tip radius with increasing electrode gap, 2mm to 12mm. It was calculated electrical breakdown strength at tip using Mason\`s equation from breakdown voltage As gap lenght increased. breakdown strength increased linearly. But, as tip radius of needle increased, breakdown strength decreased exponentially. It can be explained by tole phenomenon that electron is easily injected, as tip radius increases, and effective work function decreases. When appling DC voltage. breakdown 7tr7ilgtll was higher wheal polarity of needle was negative than positive. It is because of the space charge effect ill accordance with the influence of liquid motion.

  • PDF

전기설비용 Epoxy/$SiO_2$ 복합재료의 계면처리 효과에 따른 직류 절연파괴 강도의 개선에 관한 연구 (A Study on Improvement of DC Breakdown Strength due to Interface Treatment Effect of Epoxy/$SiO_2$ Compund Material for Electrical installation)

  • 김재환;박창옥;김경환;김명호
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제6권2호
    • /
    • pp.51-55
    • /
    • 1992
  • In this study as treating to filter silance coupling agent (KM-6030 improving coupling strength between matrix resin (bisphenole-A type epoxy resin) and filler (SiO2), breakdown strength was investigated on cases applying DC voltage to specimen. In the case on DC voltage, breakdown strength was improved bout 12.73% and 10.77% in specimen of 5[wt%] and 50[wt%] of filler content of 10 of epoxy. Therefore, it was investigate the effect that concentration of coupling agent and content of filler was influential on breakdown strength of epoxy resin.

  • PDF

Electrical Insulation Properties of Nanocomposites with SiO2 and MgO Filler

  • Jeong, In-Bum;Kim, Joung-Sik;Lee, Jong-Yong;Hong, Jin-Woong;Shin, Jong-Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • 제11권6호
    • /
    • pp.261-265
    • /
    • 2010
  • In this paper, we attempt to improve the electrical characteristics of epoxy resin at high temperature (above $80^{\circ}C$) by adding magnesium oxide (MgO), which has high thermal conductivity. Scanning electron microscopy (SEM) of the dispersion of specimens with added MgO reveals that they are evenly dispersed without concentration. The dielectric breakdown characteristics of $SiO_2$ and MgO nanocomposites are tested by measurements at different temperatures to investigate the filler's effect on the dielectric breakdown characteristics. The dielectric breakdown strength of specimens with added $SiO_2$ decreases slowly below $80^{\circ}C$ (low temperature) but decreases rapidly above $80^{\circ}C$ (high temperature). However, the gradient of the dielectric breakdown strength of specimens with added MgO is slow at both low and high temperatures. The dielectric breakdown strength of specimens with 0.4 wt% $SiO_2$ is the best among the specimens with added $SiO_2$, and that of specimens with 3.0 wt% and 5.0 wt% MgO is the best among those with added MgO. Moreover, the dielectric strength of specimens with 3.0 wt% MgO at high temperatures is approximately 53.3% higher than that of specimens with added $SiO_2$ at $100^{\circ}C$, and that of specimens with 5.0 wt% of MgO is approximately 59.34% higher under the same conditions. The dielectric strength of MgO is believed to be superior to that of $SiO_2$ owing to enhanced thermal radiation because the thermal conductivity rate of MgO (approximately 42 $W/m{\cdot}K$) is approximately 32 times higher than that of $SiO_2$ (approximately 1.3 $W/m{\cdot}K$). We also confirmed that the allowable breakdown strength of specimens with added MgO at $100^{\circ}C$ is within the error range when the breakdown probability of all specimens is 40%. A breakdown probability of up to 40% represents a stable dielectric strength in machinery and apparatus design.

장간유리애자 파손시 절연파괴 특성 (The Electrical Breakdown Characteristics of Broken Toughened Glass Stem Insulator)

  • 정종욱;정진수;김영석
    • 전기학회논문지
    • /
    • 제57권8호
    • /
    • pp.1398-1406
    • /
    • 2008
  • This paper describes the electrical breakdown characteristics of broken toughened glass stem insulators by comparing with those of sound ones. The broken toughened glass stem insulators were taken from the electric railway field. According to the international standards, the sound and broken toughened glass stem insulators were tested in electrical strength. In the test, the power frequency voltage and the impulse voltage with a standard waveform were applied to the insulators. The power frequency voltage tests were carried out under both dry and wet condition and the impulse voltage tests under only dry condition. The acquired results were compared one another and discussed in electrical breakdown characteristic by analyzing the flashover progress pictures. As a result, the electrical strength of the broken toughened glass insulators was acquired and the processes of the surface breakdown on the toughened glass insulators were confirmed.

Electrical Properties and Temperature Effects of PET Films with Interface Layers

  • Dong-Shick kim;Lee, Kwan-Woo;Park, Dae-Hee;Lee, Jong-Bok;Seun Hwangbo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제1권4호
    • /
    • pp.25-29
    • /
    • 2000
  • In this paper, PET(Ployethylene Terephthalate) films with semiconducting and interface layers were investigated, The electrical properties, such as volume resistivity, tan$\delta$(dissipation factor) and breakdown strength at various temperatures were measured. Thermal analysis of PET and semiconducting films were measured and compared by differential scanning calorimeter(DSC) of each film. It is found that the volume resistivity of films(dependence on semiconducting interface layers)and electrical properties of PET films are changed ,Breakdown strength and dissipation factor of PET films with semiconducting layer (PET/S/PET) are decreased more greatly than PET and PET/PET films, due to the increase of charge density of charges at two contacted interfaces between PET and semiconductor, The dissipation factor of each films in increased with temperature,. For PET/S/PET film, is depended on temperature more than PET of PET/PET. However, the breakdown strength is increased up to 85$\^{C}$ and then decreased over 100$\^{C}$The electrical properties of PET films with semiconducting/interface layer are worse than without it It is due to a result of temperature dependency, which deeply affects thermal resistance property of PET film more than semiconducting/interface layers.

  • PDF

HVDC용 나노복합 절연재료의 DC절연파괴 분석 (Analysis of DC dielectric breakdown strength of Nano-composite insulation material for HVDC Cable)

  • 조성훈;정의환;이한주;임기조;정수현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.104-104
    • /
    • 2010
  • With the advent of nano-particle fillers in insulating materials, the insulating materials of superior quality have come to fore. In the recent past, nanocomposite LDPE/XLPE (Low Density Polyethylene/Cross Linked Polyethylene) power cable dielectrics have been synthesized. A preliminary evaluation of these new class of materials seem to show that, addition of small amounts of sub-micron inorganic fillers improved the dielectric properties of the composite, in particular, the volume resistivity, and the DC breakdown strength. The thermal behaviour, for example, the stability of composites against decomposition and ensuing electrical failure, do not seem to have been addressed. In a conventional XLPE insulated cable, the average thermal breakdown strength and maximum temperature at the onset of breakdown were seen to be markedly lower than the corresponding intrinsic breakdown strength and decomposition temperature. In this page, analysis of DC Breakdown of nano-composite insulating material for HVDC Cable is introduced.

  • PDF

DC 절연파괴 특성을 이용한 Epoxy 복합체의 절연 신뢰도 평가 (Evaluation of Insulating Reliability in Epoxy Composites by DC Dielectric Breakdown Properties)

  • 임중관;박용필;김정호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.92-95
    • /
    • 2001
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were simulated by Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric field is concentrated. In the case of filled specimens with treating silane, the breakdown strength become much higher Finally, from the analysis of weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1[%], the applied field value needed to be under 21.5 [Mv/cm].

  • PDF

에폭시 복합체의 절연신뢰도 및 파괴수명 예측 (Prediction of Insulation Reliability and Breakdown Life in Epoxy Composites)

  • 신철기;박건호;왕종배;김성역;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.260-264
    • /
    • 1996
  • In this study, the dieiectric breakdown of epoxy composites used for transformers was experimented and then its data were simulated by Weibull distribution probability . As a result. first of all, speaking of dielectric breakdown properties, the more hardener increased the stronger breakdown strength at low temperature, and the breakdown strength of specimens because it is believed that the adding filler farms interface and charge is accumulated in it, therefore the molecular motility is raised, the electric field is concentrated, and the acceleration of electron and the growth of electron avalanche are early accomplished. In the case of filled specimens with treating silane, the breakdown strength become much higher since the suggests that silane coupling agent improves interfacial combination and relays electric field concentration. Finally, from the analysis 7f weibull distribution. it was confirmed that as the allowed breakdown probability was given by 0.11[%].

  • PDF

다양한 첨가제에 따른 가교폴리에틸렌의 절연특성 분석 (A study on insulation Characteristics of XLPE by various additives)

  • 송상민;김규식;손원근;류부형;박수길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.193-196
    • /
    • 2001
  • XLPE is occasionally happened to deteriorate cable insulation characteristics. It is happened to do a breakdown state by the degradation of electrical characteristic and electrical breakdown strength. I prepared TR-XLPE (Tree-Retardant XLPE) as adding various additives to prevent its states. Various additives are treeing retardants, anti-oxidants. Treeing retardants three kinds of aromatic compounds as adding each additive. Anti-oxidants use quinone compound and cresol compound as adding each additive. In order to observe each electrical characteristics, I measured breakdown strength, relative dielectric constant$({\varepsilon}_r)$, dielectric loss tangent$(tan{\delta})$. TR-XLPE specimens as adding treeing retardants and anti-oxidants enhance breakdown strength, ${\varepsilon}_r$, $tan{\delta}$ than pure XLPE.