• 제목/요약/키워드: Electrical apparatus

검색결과 694건 처리시간 0.023초

고조파 유출 억제기술의 동향 (The Trend of suppression technology of harmonics for distribution system)

  • 고희석;이현무;이충식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.330-332
    • /
    • 2004
  • Reliance on electric power has increased together with customer's demand for delightful and convenient linging. Recently, as appeared in the rapid growth of the technology of power electronics, the installation and apparatus using semiconductor applicotion is widly supplied and used from a household goods to industrial goods. However, these machine generate harmonics current and voltage for electric power system. The harmonics current is increased voltage distortion and generate a lot of interference in the electric power system. In this paper, the trend of the trend of suppression technology of harmonics outflow and the fundamental theory about the suppression of harmonics current in the distribution system are investigated and evaluated Therefore we look forward to supply electric power of good quality to satisfy the harmonics current guide line which is applied to household goods in the world.

  • PDF

코일건 발사 시스템의 발사속도 향상을 위한 최적설계 (Optimal Design to Improve Launch Velocity of Coilgun Launching System)

  • 박창형;김진호
    • 한국기계가공학회지
    • /
    • 제17권5호
    • /
    • pp.131-136
    • /
    • 2018
  • Research on space development and satellites is being actively pursued. An interesting field is the study of reliable low-cost space launch vehicles. Since chemical fuel-based launching systems are expensive and take a lot of time and cost to maintain, the EML system, which is an electromagnetic force launching apparatus, is attracting attention. The EML system converts electrical energy stored in a capacitor into magnetic energy, and converts magnetic energy into mechanical kinetic energy, thereby accelerating the projectile. Although studies are actively conducted in the field, it is difficult to solve the equation because the impedance and speedance change with time and the nonlinearity is strong. Many researchers have solved this equation in a variety of methods. In this paper, the velocity analysis of the projectile was carried out by FEM (finite element method) using the commercial electromagnetic analysis program MAXWELL.

Imaging System Science Laboratory

  • Nalcioglu, O.;Cho, Z.H.
    • 대한의용생체공학회:의공학회지
    • /
    • 제4권1호
    • /
    • pp.3-8
    • /
    • 1983
  • Characteristics of the lung inflation and deflation reflexes were measured at various temperatures on the cervical vagi in five anesthetized mongrel dogs. Nerve temperature was maintained at the body temperature, and 2-14˚C with 2˚C apart using a specially designed automated vagal cooling apparatus with an accuracy to within $\pm$ 0.1˚c at each temperature. The inflation reflex was blocked abruptly at 8-10˚C. The deflation reflex started weakened at 14˚C, thereafter showed a gradual blockade with the temperature decreased with a substantial variance among the animals.It was approximately 75% blocked at 2-5˚C. These differences in temperature characteristics made it hard to differentiate the deflation reflex from the inflation reflex. In one animal, however, the inflation reflex was completely blocked with the deflation reflex almost alive at 6-8˚C. This suggests that differential cold blockade of the vagal reflexes can be done only in selected subjects. Furthermore, the fact that these two reflexes were blocked at different temperatures may be due to the differences in the nerve fiber size and the changes in the conduction velocity with temperature.

  • PDF

방사선 검출기 적용을 위한 액정 기반 다층 구조의 광 특성 평가 (The optical characteristics study of sandwich structure based liquid crystal for the radiation detector application)

  • 신정욱;강상식;박지군;조성호;차병열;김진영;이건환;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.390-392
    • /
    • 2005
  • The digital radiation detectors are used clinically by diagnostic apparatus. However the digital radiation detector are some problem like high operating voltage, light blurring, low conversion efficiency, low fill factor, etc. Thus we propose a new radiation detector that the photoconductor layer and liquid crystal layer are coupled in sandwich structure. X-ray absorption in the photoconductor layer controls the state of the liquid crystal via creation of charge carrier and the light modulation of liquid crystal make image formation. The advantage of the new radiation detector is that high resolution image is acquired and the signal amplification is possible by external visible light source. In this study, we study the optical properties and electrical properties of the new radiation detector to irradiate X-ray. The Mercury Iodide($HgI_2$) was used by photoconductor material, and the aluminum is used by reflective layer. The thickness of Mercury Iodide is about $200{\mu}m$, the operating voltage of the liquid crystal is 1.5~5V. The electrical properties of Mercury Iodide was measured, and the transmission efficiency of liquid crystal was measured by modulation potential.

  • PDF

전기자극 시 활동주기 형태의 변화가 혈중젖산과 혈장효소에 미치는 영향 (The Effects of Changing Duty Cycle With Electrical Stimulation on Blood Lactate and Plasma Enzyme)

  • 고태성;정호발
    • 한국전문물리치료학회지
    • /
    • 제12권2호
    • /
    • pp.90-97
    • /
    • 2005
  • By measuring changes in blood lactate and plasma enzyme (CPK, GOT, GPT) with electrical stimulation applied at two duty cycles, this study is intended to look into which type of duty cycle may have more effects on blood lactate and plasma enzyme constituents through animal experiment so as to determine any duty cycle appropriate for electrical treatment. In this study, electrical stimulation was applied to total 20 Korean house rabbits (weight: 3~3.5 kg) by means of an electrical therapeutic apparatus called TS6000 (made in Netherlands) at duty cycle of 50% and 20% respectively for 30 minutes. Here, 5 cc of blood was collected from their carotid artery before stimulation and in 30 minutes after stimulation respectively to carry out biochemical experiment and analysis. As determined through the above experiment, blood lactate rate was increased to 333.07% at 50% duty cycle after experiment and 185.71% at 20% duty cycle after experiment respectively. In both cases, blood lactate rate was significantly increased to higher level after electrical stimulation than before. Moreover, the rate of change in the average of blood lactate rate at both duty cycles also showed significant differences. CPK rate was boosted to 301.82% at 50% duty cycle after experiment and 321.35% at 20% duty cycle after experiment respectively. In both cases, CPK rate was remarkably boosted to higher level after stimulation than before (p<.05). However, there was not any significant difference in the rate of change in average CPK at both duty cycles (p<.05). GOT rate was significantly boosted up to 38.97% at 50% duty cycle after experiment (p<.05), while it was slightly increased to 1.68% at 20% duty cycle after experiment without any significant difference. Rather, GPT rate dropped slightly at both duty cycles after experiment, but there was not any significant difference. Although blood lactate and GOT were relatively less generated at 20% duty cycle after electrical stimulation than at 50% duty cycle, the change of duty cycle didn't have any significant influence on CPK rate. In this regard, this study failed to come any consistent conclusion about the association between change of duty cycle and muscle fatigue. Therefore, it is advisable that follow-up studies seek various ways to a little more effectively apply electrical stimulation to laboratory animals by avoiding their muscle fatigue. GOT rate was significantly boosted up to 38.97% at 50% duty cycle after experiment (p<.05), while it was slightly increased to 1.68% at 20% duty cycle after experiment without any significant difference. Rather, GPT rate dropped slightly at both duty cycles after experiment, but there was not any significant difference. Although blood lactate and GOT were relatively less generated at 20% duty cycle after electrical stimulation than at 50% duty cycle, the change of duty cycle didn't have any significant influence on CPK rate. In this regard, this study failed to come any consistent conclusion about the association between change of duty cycle and muscle fatigue. Therefore, it is advisable that follow-up studies seek various ways to a little more effectively apply electrical stimulation to laboratory animals by avoiding their muscle fatigue.

  • PDF

BioPAC 모듈을 이용한 마우스 시각유발전위 측정 시스템 확립 (Measuring System of Visual Evoked Potential (VEP) in Mice using BioPAC Modules)

  • 이왕우;안정열;구용숙
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권1호
    • /
    • pp.16-24
    • /
    • 2017
  • For the development of feasible retinal prosthesis, one of the important elements is acquiring proper judging tool if electrical stimulus leads to patient's visual perception. If evoked potential to electrical stimulus is recorded in primary visual (V1) cortex, it means that the stimulus effectively evokes visual perception. Therefore, in this study, we established VEP recording system on V1 cortex using BioPAC modules as the judging tool. And the measuring system was evaluated by recording VEP of mice. After anesthesia, normal mice (C57BL/6J strain; n = 6) were secured to stereotaxic apparatus (Harvard Apparatus, USA). For the recording of VEP, the stainless steel needle electrode (impedance: $2-5k{\Omega}$) was positioned on the surface of the cortex through the burr hole at 2.5 mm lateral and 4.6 mm caudal to bregma. DA 100C and EEG 100C BioPAC modules were used for the trigger signal and VEP recording, respectively. When left eye was blocked by black cover and right eye was stimulated by flash light using HMsERG (RetVet Corp, USA), VEP response at left V1 cortex was detected, but there was no response at right V1 cortex. Amplitudes and latencies of P2, N3 peaks of VEP recording varied according to the depths of the electrodes on V1 cortex. From the surface upto $600{\mu}m$ depth, amplitudes of P2 and N3 increased, while deeper than $600{\mu}m$, those amplitudes decreased. The deeper the insertion depth of the electrode, the latency of N1 peaks tends to be delayed. However, there was no statistically significant difference among the latencies of P2 and N3 peaks (P > 0.05, ANOVA). Our VEP recording data such as the insertion depth and the latency and amplitudes of peaks might be used as guidelines for electrically-evoked potential (EEP) recording experiment in near future.

요골동맥 직경 변화에 따른 맥파 측정 시스템 개발 (Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation)

  • 이전;우영재;전영주;이유정;김종열
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.

직렬 아크에 따른 도체의 산화물 증식 및 전압 파형 분석 (The Analysis of Voltage Waveform and Oxidation Growth of Conductor with Series Arc)

  • 최충석;김향곤;김동욱;김동우
    • 전기학회논문지P
    • /
    • 제55권3호
    • /
    • pp.146-152
    • /
    • 2006
  • In order to analyze the characteristics of series arcs that could happen in poor connections of electrical facilities, we made an apparatus which is similar to actual situation. series arcs are generated between copper and copper, copper and bronze, copper and brass, bronze and bronze, and then oxidation growth and voltage waveform were measured. A very small vibration with constant movement is needed to grow oxidation initially, whereas oxidation growth proceeded without a vibration after a certain amount of time. At first, blue white flame was generated initially between copper and copper, and then yellow flame was generated. In case of contact between copper and copper, the length of oxidation growth was about 7.1[mm] in 90[min]. In case of contact between copper and brass, the length of oxidation growth was about 4.3[mm] in 90[min], When bronze is contacted with copper, the lengths of oxidation growth were about 1.4[mm] in 20[min] and 2.7[mm] in 40[min] respectively, and no more oxidation growth was shown after that. In case of contact between brass and brass, the length of oxidation growth was about 1.2[mm] in 90[min], so it was the smallest compared to other cases. When copper is contacted with copper, the current through the load was about 1.6[A] and the power dissipation increased from 19[W] to 31[W]. In case of oxidation growth between copper and brass, the voltage changed from 8.4[V] to 11[V]. However, the voltage drop and the power dissipation between copper and brass were small compared to oxidation growth between copper and copper. When series arcs were generated between bronze and copper, a peak was shown at the beginning of voltage increase, and 40[min] later, oxidation material was not grown any longer. When oxidation growth occurred, voltage waveform showed irregular waveforms with tiny ripples.

인버터 입력전류 분석을 이용한 유도전동기 고장진단 (Diagnosis of Induction Motor Faults Using Inverter Input Current Analysis)

  • 한정호;송중호;최규형
    • 한국산학기술학회논문지
    • /
    • 제17권7호
    • /
    • pp.492-498
    • /
    • 2016
  • 운전 중인 유도전동기에 고장이 발생하면, 구동장치 등 전체 시스템에 2차적인 고장을 유발 시킬 수 있다. 이 경우 구동시스템의 신뢰도와 안전성이 저하되고, 경제적인 손실을 초래할 뿐만 아니라, 인명 피해의 위험 등 많은 문제가 발생할 수 있다. 따라서 유도전동기의 고장징후를 조기 감지하여 전체 시스템 고장을 방지할 수 있도록 하는 유도전동기 고장진단 방법이 필요하다. 본 논문은 유도전동기에서 고정자권선의 부분 단락과 회전자 바의 균열이 발생하는 경우, 인버터 입력전류를 분석하여 고장징후를 조기 감지하는 유도전동기 고장진단 방법을 제안한다. 제안한 고장진단 방법은 고정자 전류 3개를 모두 센싱해야 하는 기존 고장진단 방법과 달리, 인버터 입력전류 센서 한 개만으로 유도전동기 고장진단이 가능하다. 또한, 정상전류 주파수성분과 고장전류 주파수성분이 서로 분리되어 나타나는 인버터 입력전류 특성을 통해 기존 고장진단 방법보다 비교적 쉽고 확실한 고장진단이 가능하다. 시뮬레이션을 통하여 제안한 유도전동기 고장진단 방법의 우수성과 유효성을 확인한다.

DEVELOPMENT OF COMBIND WELDING WITH AN ELECTRIC ARC AND LOW POWER CO LASER

  • Lee, Se-Hwan;Massood A. Rahimi;Charles E. Albright;Walter R. Lempert
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.176-180
    • /
    • 2002
  • During the last two decades the laser beam has progressed from a sophisticated laboratory apparatus to an adaptable and viable industrial tool. Especially, in its welding mode, the laser offers high travel speed, low distortion, and narrow fusion and heat-affected zones (HAZ). The principal obstacle to selection of a laser processing method in production is its relatively high equipment cost and the natural unwillingness of production supervision to try something new until it is thoroughly proven. The major objective of this work is focused on the combined features of gas tungsten arc and a low-power cold laser beam. Although high-power laser beams have been combined with the plasma from a gas tungsten arc (GTA) torch for use in welding as early as 1980, recent work at the Ohio State University has employed a low power laser beam to initiate, direct, and concentrate a gas tungsten arcs. In this work, the laser beam from a 7 watts carbon monoxide laser was combined with electrical discharges from a short-pulsed capacitive discharge GTA welding power supply. When the low power CO laser beam passes through a special composition shielding gas, the CO molecules in the gas absorbs the radiation, and ionizes through a process known as non-equilibrium, vibration-vibration pumping. The resulting laser-induced plasma (LIP) was positioned between various configurations of electrodes. The high-voltage impulse applied to the electrodes forced rapid electrical breakdown between the electrodes. Electrical discharges between tungsten electrodes and aluminum sheet specimens followed the ionized path provided by LIP. The result was well focused melted spots.

  • PDF