• Title/Summary/Keyword: Electrical apparatus

Search Result 694, Processing Time 0.019 seconds

Study on Physical Properties of Domestic Species I: Sorption, Thermal, Electrical and Acoustic Properties of Pinus Densiflora (국산재의 응용물성연구 I: 소나무(Pinus densiflora)의 수분흡착성 및 열적·전기적·음향적 성질)

  • Kang, Ho-Yang;Byeon, Hee-Seop;Lee, Won-Hee;Park, Byung-Soo;Park, Jung-Hwan
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.70-84
    • /
    • 2008
  • A series of the studies on the applied physical properties of domestic species have been conducted last three years. Pinus densiflora was one of the three species examined for the first year. Because the same apparatus and experimental procedures were used for all species, their results can be easily comparable. The experiments for sorption property were conducted with 20- and 80-mesh wood powder and resulted in their EMC's and sorption isotherms at various heating conditions. The thermal conductivity and diffusivity, and electric resistance and volumetric electric resistivity were measured with a thermal-wire device and a high electric resistance meter. The differences of the thermal and electric properties between quarter- and flat-sawn specimens were observed, which was partially attributed to their anatomical differences. An acoustic measurement system was used to evaluate dynamic MOE and internal friction. This paper provides the useful fundamental data for designing a wood structure, correcting a portable resistance-type moisture meter, and nondestructive testing wood.

Separation of $SF_6$ from $SF_6/N_2$ Mixtures Using Polymeric Membranes (고분자 분리막을 이용하여 $SF_6/N_2$ 혼합 기체에서 $SF_6$ 분리)

  • Ko, Young-deok;Lee, Hyung-Keun;Hong, Seong-Uk
    • Membrane Journal
    • /
    • v.22 no.1
    • /
    • pp.72-76
    • /
    • 2012
  • $SF_6$ has an extremely high global worming potential (GWP). Therefore, there has been an effort to reduce the use of $SF_6$ and its emission into atmosphere. One possible solution for minimizing the use of $SF_6$ in electrical equipments is utilization of gas mixtures such as $SF_6/N_2$. The $SF_6$ concentration in the gas mixture varies from 10 to 60%. However, when the apparatus is repaired or dismantled, we have to recover $SF_6$ from the gas mixture. Since the boiling point of $SF_6$is low (${\sim}-60^{\circ}C$), the liquefaction method is difficult to apply. One possible alternative is the membrane separation technology. In this study, we investigated the $SF_6$ and $N_2$ permeation properties of 5 polymeric membranes. For example, permeability of $N_2$ in BOPP membrane at $25^{\circ}C$was 0.19 barrer, whereas that of $SF_6$ was only 0.0012 barrer, resulting in the selectivity of 158. An upper bound for $SF_6/N_2$ gas pair was suggested for the first time with n = -1.33 and k = 160 (barrer).

Development of Flow Loop System to Evaluate the Performance of ESP in Unconventional Oil and Gas Wells (비전통 유·가스정에서 ESP 성능 평가를 위한 Flow Loop 시스템 개발)

  • Sung-Jea Lee;Jun-Ho Choi;Jeong-Hwan Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.7-15
    • /
    • 2023
  • The electric submersible pump (ESP) has been operating in production wells around the world because of its high applicability and operational efficiency among artificial lift techniques. When operating an ESP in a reservoir, variables such as temperature, pressure, gas/oil ratio, and flow rate are factors that affect ESP performance. In particular, free gas in the production fluid is a major factor that reduces the life and operational efficiency of ESP. This study presents the flow loop system which can implement the performance and damage tests of ESP considering field operating conditions to quantitatively analyze the variables that affect ESP performance. The developed apparatus in an integrated system that can diagnose the failure and causes of ESP, and detect leak of tubing by linking ESP and tubing as one system. In this study, the flow conditions for stable operation of ESP were identified through single phase and two phase flow experiments related to evaluation for the performance of ESP. The results provide the basic data to develop the failure prediction and diagnosis program of ESP, and are expected to be used for real-time monitoring for optimal operating conditions and failure diagnosis for ESP operation.

Effects of Magnetic Resonance Imaging on the Human Body : Analysis of differences according to Dental Implant Material (자기공명영상이 인체에 미치는 영향 : 치아임플란트 재료에 따른 차이 분석)

  • Choe, Dea-yeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.481-489
    • /
    • 2018
  • In MRI examination, when irradiating the human body with RF Pulse to acquire images, the portion of the irradiated RF Pulse energy is absorded into the human body, and this will affect the temperature of the human body. If a metal is inserted into the human body even if the same RF Pulse energy is applied, the SAR value increases and the body temperature changes due to the increase in the electromagnetic wave conductivity of the metal. So we measure and compared with the change in the SAR and temperature in the implant material of the dental implant in Brain MRI examinations. Experiments were performed on a human head model using a 64MHz and 128 MHz RF Pulse frequency generated by a 3.0 Tesla MRI apparatus. And then changed material of dental implants to Titanium and $Al_2O_3$. Using the XFDTD program, the changes in SAR and body temperature around the head were examined. When with Titanium the SAR value and temperature of Brain increased, but with $Al_2O_3$ showed lower SAR and temperature as compared with Titanium. The dental implants were low in SAR and temperature of the head in $Al_2O_3$, which are electrical insulators with low electrical conductivity, compared to Titanium, which is an electrical conductor. It is necessary to study the biologic effect of patient with brain MRI when titanium dental implant material is inserted in the future. Because the maximum value of SAR is much higher than the limit when dental implant material is Titanium. In addition, it is necessary to use an implant of $Al_2O_3$ material to reduce the SAR value and temperature of the Brain in Brain MRI examination.