• Title/Summary/Keyword: Electrical accident

Search Result 519, Processing Time 0.025 seconds

Real-time Remote Monitoring System of Chemical Accident Response based on Multi-hop Communication (멀티 홉 통신을 기반한 화학 사고 대응 실시간 원격 모니터링 시스템)

  • Lee, Seung-Chul;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.11
    • /
    • pp.1706-1712
    • /
    • 2022
  • Recently, the safety of chemical substances has gained attention due to incidents occurring in petrochemical industrial complexes, such as gas leaks and fires. In particular, industrial complexes in Ulsan and Yeosu (South Korea) are valuable as they significantly contribute to the petrochemical industry, but accidents may occur due to chemical leakage. Therefore, in this study, sensor nodes are configured at an interval of 20 [m] based on outdoor facilities standards to respond to chemical accidents, and exposure consideration of 8 h (TWA) and 15 min (STEL) are proposed in TLVs. The proposed system pre-processes data collected in multi-hop communication at a cycle of 0.6-0.75 [s] using Python and stores it in the MySQL database through SQL and a real-time remote monitoring system that updates the stored data once every 5 s is implemented by linking MySQL and Grafana.

An Integrated Sensor Module for Diagnosis of Closed Switchboards (수배전반 진단을 위한 통합형 센서모듈)

  • Cha, Sang-Wook;Cha, Hyeon-Kyu;Park, Dae-Won;Park, Hee-Chul;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2043-2048
    • /
    • 2011
  • According to the statistical report from National Emergency Management Agency (NEMA) in Korea, the accident rate of closed switchboards in power systems occupies over 40%. In this paper, an integrated sensor module for monitoring the condition of closed switchboards is described. The sensor module monitors electro-magnetic (EM) wave, ultra-violet (UV) ray, heat and smoke generated by electrical discharges or insulation breakdown. The effective detection ranges were decided from experiment results; 100 kHz~10 MHz for EM wave, 220 nm~395 nm for UV ray and 0~$150^{\circ}C$ for heat, respectively. The prototype sensor module includes all functions above-mentioned in one device.

  • PDF

A Recent Development of Haptic Devices for Temematics Control Units (텔레매틱스 단말기에서 사용가능한 Haptic 디바이스 개발 동향)

  • Ma, Jin-Suk;Kim, Hung-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.406-409
    • /
    • 2004
  • Recently, many auto makers and OEM are now developing various telematics control units(TCU). TCU has an embedded OS and many user-friendly services inherently and frequently the driver operates the TCU on driving a car. Although the TCU has some accident resistive functions, secondhand accidental problem arose. Current Korean domestic TCUs have some interfaces such as push-button, touch screen, voice recognition and etc. But, because of operational complexity, technical limitation, it has not sufficient user-friendly interface. In this paper, to overcome this problem, haptic devices are considered. We present haptic devices and applications on the basis of that of U.S. Immersion co. and also BMW's iDrive technology.

  • PDF

Fault Diagnosis System for Industrial Motor Drives (산업용 전동기 구동장치의 고장진단 시스템)

  • Song, S.H.;Cho, W.J.;Park, I.Y.;Park, K.W.;Lee, C.W.;Kim, K.H.;Choi, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.488-490
    • /
    • 1994
  • To meet the requirements of high performance and reliability as a industrial motor drive, we developed an integrated oil-line fault diagnosis and monitoring system which consists of DSP-based controller and PC-based MMI (Man-machine interface) program. The dedicated controller performs real-lime fault detections and protections. The MMI program monitors the on-line fault status of the drive system and offers full explanations of the fault name(WHAT?), deducible causes of the fault operation(WHY?), and chock points (HOW?) based upon the experiences of the expert. Also the TRACE data which was stored just before and after the accident can be scrutinized using MMI tools.

  • PDF

Charge Accumulation in Glass under Electron Beam Irradiation (전자빔 조사중 유리의 전하축적)

  • Cho, Jae-Chul;Hwang, Jong-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.235-236
    • /
    • 2008
  • Charging of spacecraft occurs in plasma and radiation environment. Especially, we focused on an accident caused by internal charging in a glass material that was used as the cover plate of solar panel array, and tried to measure the charge distribution in glass materials under electron beam irradiation by using a PEA (Pulsed Electro-Acoustic method) system. In the case of a quartz glass (pure $SiO_2$), no charge accumulation was observed either during or after the electron beam irradiation. On the contrary, positive charge accumulation was observed in glass samples containing metal-oxide components. It is found that the polarity of the observed charges depends on the contents of the impurities. To identify which impurity dominates the polarity of the accumulated charge, we measured charge distributions in several glass materials containing various metal-oxide components and calculated the trap energy depths from the charge decay characteristics of all glass samples.

  • PDF

EMTP Analysis for Ferroresonsnce of Gas Insulated Switchgear (가스절연개폐장치(GIS) 철공진(Ferroresonance) EMTP해석)

  • Chung, Y.H.;Lee, D.S.;Kim, J.B.;Lee, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.366-367
    • /
    • 2008
  • This paper deal with the study of the phenomenon of Ferroresonance in the 170kV Gas Insulated Switchgear(GIS). The Electromagnetic Transient Program(EMTP) was used to simulate the phenomenon of Ferroresonance and conducted the study of the transient over-voltage. An example power system, used in this study, have an accident that the ferroresonance phenomenon happens at MOFVT(Voltage Transformer). The simulation results notices that the secondary part of VT has to be connected by ferroresonance suppressor when the circuit breaker connected with grading capacitor is switched off.

  • PDF

Reliability Establishment Method of Switchyard Equipment (스위치야드 기기 신뢰도 군축방안)

  • Moon, Su-Cheol;Kim, Keron-Joong
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.51-53
    • /
    • 2007
  • The nuclear power plant uses the steam which occurs from reactor and T/G the drive. By the T/G in consequence of the fact that the electricity which is produced the power and supplies in transmission system. But, recently the transmission and generation system are placed under deregulation situation from domestic and foreign, the maintenance control is difficult with the accident or the breakdown which relates is increasing. Hereupon, considering for effect to the reactor core against trip element which it does apply a probability concept from the NRC of the United States and it study and the recognition for the importance of the switchyard which is a power equipment which will be revaluated. Hereupon using the American example, the reliability establishment method which is suitable in domestic and it searches it does.

  • PDF

Risk Analysis of Electrical Fire for Electric Power Installations by Event Tree Analysis (사건수목분석을 통한 수배전설비의 전기화재위험성 분석)

  • Park, Young Ho;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.16-21
    • /
    • 2016
  • The purpose of this paper is to conduct ETA on 15 components of power installations: the DS/LBS, LA, MOF, CT, PT, A/V meter, VCB, OCR, COS, PF, Transformer, Condenser(C), Grounding, Cable and Connector. To achieve that, power installations work flow and its components are categorized. Based on performance, human, environmental, management, and safety, this paper drew Initiation events (IE) and End states (ES). ETA is applied to the main functions of each component, and the end states that may occur in one initiation event are suggested. In addition, detailed classification was performed to induce various end states on the basis of the suggested initiation events. If the suggested IEs and ESs are applied on the basis of power installations event cases, it is expected to prevent the same kinds of accident and operate power installations safely.

A Study on the Stabilization Force Control of Robot Manipulator

  • Hwang, Yeong Yeun
    • International Journal of Safety
    • /
    • v.1 no.1
    • /
    • pp.1-6
    • /
    • 2002
  • It is important to control the high accurate position and force to prevent unexpected accidents by a robot manipulator. Direct-drive robots are suitable to the position and force control with high accuracy, but it is difficult to design a controller because of the system's nonlinearity and link-interactions. This paper is concerned with the study of the stabilization force control of direct-drive robots. The proposed algorithm is consists of the feedback controllers and the neural networks. After the completion of learning, the outputs of feedback controllers are nearly equal to zero, and the neural networks play an important role in the control system. Therefore, the optimum adjustment of control parameters is unnecessary. In other words, the proposed algorithm does not need any knowledge of the controlled system in advance. The effectiveness of the proposed algorithm is demonstrated by the experiment on the force control of a parallelogram link-type robot.

Surveillance System For Extra High Voltage Cable (초고압 CABLE 감시시스템 연구)

  • Hahn, K.M.;Lee, K.C.;Jeon, S.I.;Kim, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.789-793
    • /
    • 1992
  • For improving the power supply reliability and minimizing maintenance work of E.H.V. underground transmission line, new surveillance systems are strongly desired for use in the field of electric power transmission. For underground installation, high system reliability is required because E.H.V. cables, if an accident happen, can have a serious impact on social activities and human life. In answer to this requirement, applications of optical fiber transmission system have been widely developed in a variety of field. The main function of this system are cable fault location, oil leak detection, and surveillance of the cable circuit and tunnel condition.

  • PDF