발코니 일체형 태양광발전시스템의 발전성능 분석 (Analysis of Performance of Balcony Integrated PV System)

  • 김현일;강기환;박경은;소정훈;유권종;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제29권1호
    • /
    • pp.32-37
    • /
    • 2009
  • Photovoltaic(PV) permits the on-site production of electricity without concern for fuel supply or environmental adverse effects. The electrical power is produced without noise and little depletion of resources. So BIPV(Building-Integrated Photovoltaic) system have been increased around the world. Hereby the relative installation costs of the system will be relatively low compared to traditional installations of PV in high-rise buildings. This paper examined possibility of building integrated balcony PV system and analyzed both performance and problems of this system. The system is influenced by conditions such as irradiation, module temperature, shade and architectural component etc. If this BIPV system of 1.1kW is possible the natural ventilation in the summer case, the temperature of PV module decrease and then the efficiency of PV system increase generally. By the results, the annual averaged PR of BIPV system of cold facade type is about 74.7%.

저장 탱크용 임시전력설비의 보호계전기 정정에 관한 연구 (A Study on the Correction of Protection Relay of Temporary Electric Power Installations for Storage Tank)

  • 손석금
    • 한국정보전자통신기술학회논문지
    • /
    • 제13권6호
    • /
    • pp.562-567
    • /
    • 2020
  • 본 논문은 저장 탱크용 임시전력설비를 보호하기 위한 목적으로 특히 변압기를 감시하고 절연파괴 등과 같은 고장을 차단하고 보호하기 위한 보호계전기 정정에 관한 연구이다. 전력계통에 단락 또는 지락고장 등과 같은 이상이 발생하였을 때 이를 검출하여 고장이 발생한 기기 및 설비를 신속하게 차단하고 전력계통으로부터 분리하여 전력공급에 지장이 없도록 하여야 한다. 전력계통의 이상 상태를 빠르고 정확하게 감지할 수 있는 보호계전기의 정정이 중요하다. 또한 보호협조를 위해 고장종류와 고장의 원인을 정확히 적용한 고장전류 계산이 보호계전기 정정에 가장 중요한 요소이다. 저장 탱크용 임시전력설비 보호를 위해 적용하는 과전류계전기, 지락과전류계전기, 부족전압계전기, 지락과전압계전기 등이 보호협조가 가능하도록 보호계전기 정정 방법에 대해 연구하였다.

BIM 기반 유지관리정보 모델링을 위한 객체분류목록 개발 -건축 전기/정보통신 분야를 중심으로- (Object Classification List for BIM-based Maintenance Information Modeling in Electrical and Telecommunications Field of Architecture)

  • 송종관;조근하;원지선;주기범;배시화
    • 한국산학기술학회논문지
    • /
    • 제15권5호
    • /
    • pp.3183-3191
    • /
    • 2014
  • 시설물의 운영 및 유지관리는 시설물의 전 생애주기 비용의 83% 이상을 차지하기 때문에 시설물의 효과적인 관리는 필수적으로 이루어져야 한다. 본 연구에서는 시설물의 운영 및 유지관리 단계에서 요구되는 정보를 설계 및 시공단계에서부터 관리하기 위해 BIM 객체 기반의 분류목록을 개발하였다. 이 분류목록을 개발하기 위해 건설정보분류체계, 건축전기설비설계기준, 조달청 물품목록분류를 분석하였으며, 객체분류목록을 구성하기 위한 문제점을 도출하였다. 그리고 각 기준을 비교 분석하여 KSF 1540:2010 (CAD도면 작성 원칙과 기준)의 '도면의 분야 코드'를 분야분류인 대분류로 구성하고, 건설정보 분 류체계의 부위분류를 중분류로 구성하였으며, 조달청 물품목록 분류를 소분류인 장비 및 장치분류로 분류하고 해당 코드를 부여하였다. 본 연구는 설계단계 객체관점의 분류를 제공함으로써 운영 및 유지관리단계 정보교환 및 공유에 유용할 것이다. 나아가 운영 및 유지관리단계 기능별, 공간별, 용도별 장치 및 장비관리를 가능하게 함으로써 시설물의 효과적인 운영 및 유지관리를 가능하게 할 것으로 판단된다.

고고도 전자기파(HEMP)차폐를 위한 전자파 차폐 콘크리트 벽체 개발에 관한 실험적 연구 (An Experimental Study on the Development of Electromagnetic Shielding Concrete Wall for Shielding High-altitude Electromagnetic Pulse (HEMP))

  • 최현준;김형철;임상우;이한승
    • 콘크리트학회논문집
    • /
    • 제29권2호
    • /
    • pp.169-177
    • /
    • 2017
  • 북한은 최근 핵무기의 일반적인 열, 폭풍, 방사능 피해가 아닌 전자 장비를 무력화시키기 위한 고고도 전자기파 탄을 개발 중인 것으로 예측되고 있다. 현재 군용 목적으로 사용되고 있는 HEMP 차폐 시설 중 차폐 판의 경우 전자파 차폐 효과가 뛰어난 금속 판이 사용되고 있으나 이러한 금속판들은 차폐 시설 제작 시 용접 부위에서의 전자파 유입 가능성 등 시공상의 어려움과 높은 비용이 문제시 되고 있는 실정이다. 이에 본 연구에서 차폐 시설을 따로 구축하지 않고 콘크리트 구조물 자체로써 전자파 차폐 효과를 확보하기 위하여 콘크리트 실험체에 전기전도성이 높은 재료를 혼입하였다. 또한, 실험체 중 가장 높은 차폐효과를 보인 2가지 수준과, 가장 낮은 차폐 효과를 보인 2가지 수준에 $100{\mu}m$ 아연-알루미늄 합금 금속용사 피막을 적용하였다. 실험 결과 전기전도성이 높은 재료를 혼입한 실험체는 MIL-STD-118-125-1 규격 최소 차폐 기준을 만족하지 못하였으나, 금속용사 피막을 적용한 실험체에서는 모두 최소 차폐 기준을 만족하였다. 결론적으로, $100{\mu}m$ 아연-알루미늄 합금 금속용사 피막이 HEMP 차폐에 높은 효율성을 가지고 있다고 판단된다.

전동력설비의 운전에 의해 발생되는 자계의 측정과 해석 (Analysis and Measurement of the Magnetic Fields Cause by Operation of Electromotive Installations)

  • 이복희;길경석
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권2호
    • /
    • pp.58-67
    • /
    • 1995
  • 본 논문은 유도전동기의 운전조작시에 발생되는 자계변화특성에 대하여 기술하였다. 본 측정시스템은 자기적분형 자계센서, 증폭기, 능동형 적분기로 이루어졌으며, 교정실험에 대한 측정계의 주파수대역과 감도는 각각 20[Hz]~0.234[mV/$\mu$T]이다. 유도전동기의 기동과 정상운전중에 발생하는 자계성분을 측정하였으며, 고조파 성분을 고속 푸리에 변환기법으로 분석하였다. 유도전동기의 직입기동시에는 단일성 펄스자계가 강하게 발생하였으며, 이의 피크치는 정상상태의 값보다 5배이상 크게 나타났다. 이러한 긴 과도시간과 강한 자계의 세기는 전동기의 큰 인덕턴스와 동특성에 기인된다. 유도전동기의 정상운전시에는 유도전동기의 극수에 의존하는 기본파에 대한 분조파의 자계성분이 관측되었다. 또한, 자계의 분조파 성분은 전동기의 토크 변동으로 불균일한 회전토크로 인해 생기는 맥동전류와 전압플리커에 의해서 발생하는 것으로 생각된다. 인버터구동형 유도전동기에서는 직입기동에 비하여 많은 고조파 성분이 발생되고 있었으며, 특히 전동기의 구동주파수가 낮을수록 맥동토크에 의한 전류변화로 고조파 성분은 더욱 증가하였다.

  • PDF

직업성 극저주파 자기장 노출평가와 노출 기준에 대한 쟁점 고찰 (Brief Review on Exposure Characteristics, Monitoring Instruments and Threshold Limit Values for Extremely Low Frequency-Magnetic Field (ELF-MF))

  • 박동욱;이승희;조경이
    • 한국산업보건학회지
    • /
    • 제32권4호
    • /
    • pp.381-392
    • /
    • 2022
  • Objectives: Objective of this study is to review briefly exposure characteristics, monitoring instruments and threshold limit values for extremely low frequency-magnetic field (ELF-MF) methods. This study was undertaken through brief literature review. We performed a literature search in PubMed to identify ELF-MF studies conducted in workplaces. Initial search keywords such as 'extremely low frequency-magnetic field (ELF-MF)' and 'electromagnetic fields (EMF)' combined or singly. We limited our review to occupational rather than general nonworkplace environmental exposures. Methods: The contents we reviewed: key industry and occupations generating ELF-MF, several direct-reading instruments monitoring ELF-MF and threshold limit values (TLV) preventing health effects may be caused by the exposure to ELF-MF. Results: The industries related to the generation and supply of electricity, electrolytic installations, welding, and induction heating and more were regarded as high ELF-MF exposure industries. All jobs handling or employed performed in power cable lines, electrical wiring, and electrical equipment are found to be exposed to ELF-MF. Threshold or ceiling limit, 1,000 µT, is established to prevent acute effects of exposure to low-frequency EMFs on the nervous system: the direct stimulation of nerve and muscle tissues and the induction of retinal phosphenes. The International Agency for Research on Cancer (IARC) has classified ELF-MF as possibly carcinogenic to humans chiefly based on epidemiological studies on childhood leukemia. However, a causal relationship between magnetic fields and several types of cancer including childhood leukemia has not been established nor has any other long-term effects. Risk management using precautionary measures, has been initiated by the US and EU to prevent chronic health effects related to ELF-MF exposure in workplaces. Conclusion: This study recommends the implementation of various measures such as theestablishment of occupational exposure limit values for ELF-MF and precautionary principle to prevent potential chronic occupational health effects may be caused by ELF-MF in Korea.

조선 CAD에서 선박의 Cable 점유율을 기반으로 Cable 경로 및 Overfill 가시화 구현 (The implementation of cable path and overfill visualization based on cable occupancy rate in the Shipbuilding CAD)

  • 김현재;김봉기
    • 한국산학기술학회논문지
    • /
    • 제17권11호
    • /
    • pp.740-745
    • /
    • 2016
  • 선박에는 아주 많은 기계와 장비들이 설치가 되고 이를 운용하고 제어하기 위해 수천에서 수만 가닥의 cable이 설치된다. 이러한 cable들이 복잡하게 설치되기 때문에 정확한 최단 경로 데이터가 필요하다. 하지만 cable 최단 경로를 찾기 위한 일반적인 방법인 다익스트라 알고리즘을 사용하더라도 최단 경로 내에는 반드시 overfill 구간이 생기게 마련이다. 이를 해결하기 위해 설계자는 각 구간마다 cable 점유율을 확인하지만 점유율은 data sheet 형태로 존재하기 때문에 3D cable way 모델상의 육안 식별이 어렵다. 이를 해결하기 위해 본 논문에서는 3D CAD 상에서 cable 점유율 범위에 따라 cable 경로 색상을 다르게 표현함으로써 시각적으로 overfill 구간과 cable 경로를 바로 확인이 가능하도록 cable 경로 및 overfill 가시화 시스템을 제안 구현 하였다. 이를 통해 설계단계에서 overfill 구간을 쉽게 확인할 수 있고 정확한 회피경로의 산출과 최단경로 검증이 이루어져 설치 현장에 정확한 정보가 전달됨에 따라 재작업 비율이 감소하여 작업시간이 전체 7,000 시간에서 5,600 시간으로 단축 되었고 추가로 자재비 절감 효과를 얻을 수 있다.

Tele-metering

  • Hearte, L.O.
    • 전기의세계
    • /
    • 제2권
    • /
    • pp.6-14
    • /
    • 1949
  • Telemetering may be described as the art of metering at a considerable distance those quantities which are ordinarily encountered in industry, and in the generation of electric power. It is in the production of electric power that telemetering is particularly important, for it permits the system operator, or load dispatcher, to have before him at all times a continuous graphic record of the power output of each individual generating station together with an automatically made continuous graphic record of the total system output. There desired individual graphic records may be obtained showing power flow in or out, on important tie lines, etc. Such arrangements have the very great advantage that loads may be assigned to each generating station so that the best over-all system economy may be obtained and the system operator at all times may see with his own eyes that loads scheduled are actually held at the various stations. Moreover, with such equipment, in the event of system or station trouble the load dispatcher can see exactly what station, or stations, are affected and to what extent, without having to get in touch with anyone by telephone. Decisions can, therefore, be quickly reached for rescheduling the load. One of the most accurate and reliable telemetering systems is based on the use of potentiometric circuits, the fundamentals of which are discussed below. A member of such telemetering systems have been installed for the Boston Edicon Co., Boston, Massachusetts, the Consolidated Edison Co. of New York City. The Public Service Gas & Electric Co. of Newark, new Jersey. The Philadelphia Electric Co. for Philadelphia, Pennsylvania, and the Pennsylvania Railroad Co. for their electrified zone between New York and Washington a distance of over 200 miles. The scale of the totalizing recorder for the New York area is 3,000,00 KW. That of the totalizing recorder for the Philadelphia area is 2,000,000 KW. The initial installation using this type of equipment described was placed in service for the Philadelphia Electric Co. in 1923. All of the original recording instruments are still in service, later instruments have been added to take care of additions to the power system and naturally these later recorders have incorporated in those refinements in design made since the earlier ones were manufactured. Many other installations of similar equipment have been made in the United States in various locations such as at St. Louis, on the West Coast, at Baltimore and in Washington, D.C. While the use of these basic potentiometric circuits involves the use of continuous metallic circuits of good insulation resistance and free of grounds, nevertheless, intermediate transmission links, involving and impulse method suitable for use on telephone Morse carrier channels is available. This same method may be employed on power line carrier systems and is also suitable for use on beam type microwave transmission. Many impulse type units are also used as a link in these potantiometric methods. For the sake of brevity a description is given only of these basic potentiometric circuits. If there is sufficient interest in Korea, a further paper can be given covering those impulse circuits also.

  • PDF

옥내배선, 콘센트 및 플러그 개선을 통한 전기화재 예방대책 (Electrical and Fire Prevention Measures through Improvement of Indoor Wiring, Outlets and Plugs)

  • 정성효;안희석;이용수;김창은
    • 한국건설안전학회 논문집
    • /
    • 제1권1호
    • /
    • pp.31-39
    • /
    • 2018
  • 국내에서 발생하는 화재사고 중 약 20%가 전기설비에서 기인한 화재로 확인되고 있다. 복잡하고 대형화되어있는 건축물에서 전기화재는 재산 피해와 인명 피해가 증가하면서 대형화하는 양상으로 발생하고 있다. 여러 가지 전기화재의 원인 중 누전에 의한 발화가 약 71.5%를 차지하고 있고, 전기설비별 분류에서는 배선 및 배선기구에서 발생하는 화재가 약 38.3%를 차지하고 있다. 본 연구의 목적은 현재 사용되고 있는 옥내배선 형태를 개선하여 누전으로 인한 전기화재를 예방하는 방법을 제시하고, 배선기구에서 범용 되고 있는 콘센트와 플러그를 개선하여 배선기구에서 발생하는 화재를 예방하는 근원적 방안을 찾고자 한다. 본 연구를 통해서 제시되는 전기화재 예방대책은 전기화재의 근원적 원인을 제거하여 많은 인명과 재산을 보호하는 대책으로 활용될 수 있을 것으로 기대된다.

백두산 화산재 피해 시나리오에 따른 강원도 지역 농작물의 경제적 피해 추정 (Estimation of Economic Losses on the Agricultural Sector in Gangwon Province, Korea, Based on the Baekdusan Volcanic Ash Damage Scenario)

  • 이윤정;김수도;천준석;우균
    • 한국지구과학회지
    • /
    • 제34권6호
    • /
    • pp.515-523
    • /
    • 2013
  • 백두산 화산 폭발 시 남한 지역은 동해안을 중심으로 화산재에 의한 피해가 예상된다. 적은 양의 화산재라고 할지라도 농작물의 피해나 토양의 산성화를 유발하는 등 농업 분야에 심각한 영향을 줄 수 있다. 이에 이 논문에서는 화산재에 의한 농작물의 피해를 추정하고 구글 지도를 통해 시각화하고자 한다. 이를 위해서 화산재에 대한 피해 예측모델이 필요하다. 화산재 위험은 농작물의 종류와 화산재 두께에 따라 다르므로 피해 예측 모델의 취약도 함수는 화산재 두께와 농작물의 손상률 간의 관계를 나타내어야 한다. 이 논문에서는 RiskScape에서 정의한 화산재 두께에 따른 농작물별 손상률을 이용하여 취약도 함수를 정의하였다. 이 취약도 함수를 농작물 생산량과 가격 정보에 적용하여 화산재 두께에 따른 농작물 피해액을 추정할 수 있다. 또한, 이 논문에서는 화산재의 피해가 예측되는 강원도 지역을 대상으로 화산재에 의한 농작물 피해를 추정하였다. 연구 결과 2010년 강원도 농업 총 생산량을 기준으로 했을 때 화산재가 약 4 mm 정도 쌓이게 되면 농작물 피해액은 약 6,351억 원에 달하는 것으로 나타났다. 이는 강원도 총 농업생산액의 약 50%에 해당한다. 이 논문에서는 화산재에 의한 농작물의 1차적인 피해만을 고려하고 있다. 하지만 화산재는 토양 오염이나 시설물과 같은 농가의 자산에 잠재적인 위험을 줄 수 있다. 따라서 농업 분야 전체에 대한 총 피해 규모를 추정하기 위해서는 이와 같은 2차적인 피해도 함께 고려해야 할 것이다.