• 제목/요약/키워드: Electrical Installations

검색결과 161건 처리시간 0.031초

배전피뢰기용 접지도선의 효과적인 설치기법 (Effective Installations Technique of Grounding Conductors for Metal Oxide Surge Arrestors)

  • 이복희;강성만;유인선
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권6호
    • /
    • pp.253-259
    • /
    • 2002
  • This paper deals with the effects of grounding conductors for metal oxide surge arresters. When surge arresters are improperly installed, the results can cause costly damage of electrical equipments. In particular, the route of surge arrester connection is very important because bends and links of leads increase the impedances to lightning surges and tend to nullify the effectiveness of a grounding conductor. Therefore, there is a need to know how effective installation of lightning surge arresters is made in order to control voltage and to absorb energy at high lightning currents. The effectiveness of a grounding conductor and 18 [㎸] metal oxide distribution line arresters was experimentally investigated under the lightning and oscillatory impulse voltages. Thus, the results are as follows; (1) The induced voltage of a grounding conductor is drastically not affected by length of a connecting line, but it is very sensitive to types of grounding conductor. (2) The coaxial cable having a low characteristic impedance is suitable as a grounding conductor. (3) It is also clear from these results that bonding the metal raceway enclosing the grounding conductor to the grounding electrode is very effective because of skin effect. (4) The induced voltages of grounding conductors for the oscillatory impulse voltages are approximately twice as large as those for the lightning impulse voltages.

XLPE/EPR 계면의 부분방전 패턴 분석을 위한 신경망 모형 (Neural Network Model for Partial Discharge Pattern Analysis of XLPE/EPR Interface)

  • 조경순
    • 한국컴퓨터산업학회논문지
    • /
    • 제6권2호
    • /
    • pp.357-364
    • /
    • 2005
  • 최근 들어 우리나라에서는 설치의 간편성과 높은 신뢰도를 가진 전력케이블의 사용이 증가하고 있다. 전력케이블은 출고 전에 IEEE std. 404-1993 시험을 거쳐 안정성을 확인하고 있지만 포설시 발생하는 접속부 내부의 결함으로 인하여 많은 문제가 발생하고 있다. 특히 불순물 혼입 또는 공극 발생시 고장율은 증가하게 된다 부분방전 검출은 포설 후 전력케이블의 상태를 관측할 수 있는 유용한 방법이다. 본 연구에서는 부분방전 특성을 평가하고자 케이블 접속재인 EPR과 케이블 절연체인 XPLE 사이에 인공 결함을 발생시킨 후 데이터 취득 시스템을 이용하여 $\Phi-q-n$ 특성을 검출하였으며, 부분방전의 정량적 해석을 위해 필요한 통계량을 계산하였으며, 신경망 모델을 적용하여 패턴 분석을 수행하여 $88\~96\%$의 구별이 가능하였다.

  • PDF

사물인터넷 기반의 자가용 전기설비 안전 관리 구조 연구 (Architecture of Electrical Safety Management for High-Voltage Power Installations Based on IoT Platform)

  • 강현주;안윤영;정상진
    • 한국통신학회논문지
    • /
    • 제42권5호
    • /
    • pp.1077-1084
    • /
    • 2017
  • 다양한 ICT 기술의 등장에 따라 전력설비와 ICT 기술의 융합 연구가 활발히 진행되고 있다. 고압전기설비에 대한 ICT 기술의 적용은 전력 효율 향상 및 실시간으로 정확한 사용량을 측정하기 위한 측면에서 연구되고 있으며, 전기의 안전도 향상 및 관리 측면에서는 아직 관련 연구가 미흡한 실정이다. 따라서 본 논문에서는 주요 자가용 전기설비의 안전관리 방법에 대해 분석해 보고, 사물인터넷 기술을 기반으로 전기설비 안전관리 플랫폼을 실현하기 위한 참조 구조와 참조 인터페이스, 서비스, 데이터 프로파일을 제안한다. 제안된 자가용 전기설비의 전기안전 플랫폼은 OCF에서 개발 중인 범용 IoT 오픈소스 플랫폼인 IoTivity 플랫폼을 이용하여 온습도 정보를 전달하는 시험을 통해 구현 가능성을 제시하였다.

태양광발전시스템의 효율향상을 위한 최적설계에 관한 연구 (A Study on Optimal Design of Photovoltaic System for Efficiency Progress)

  • 최영문;임중열
    • 전기전자학회논문지
    • /
    • 제13권2호
    • /
    • pp.175-180
    • /
    • 2009
  • 본 논문에서는 3[kW]급 태양광 발전시스템의 환경 조건 및 시스템 파라미터들을 고려하여 태양광어레이와 태양광인버터를 시뮬레이션 하고 태양광어레이의 설치에 따른 최적 조건과 성능을 분석을 하여 태양광 발전시스템의 최적 설계를 구현할 수 있도록 한다.

  • PDF

폴리머 애자의 내전압 특성에 따른 부분방전 측정과 자외선 검출 (PD Measure and UV Detection in according to Withstand Voltage Characteristics of Polymer Insulator)

  • 송길목;김영석;김종서;정진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.76-77
    • /
    • 2008
  • The purposes of this paper ensure for the economical efficiency, accuracy, and good applications in domestic site set up the power installations. For the efficient conduct of these purposes, there are measured the partial discharge(PD) used by current probe and compared with detected signal of UV sensor. As the results, PD generated about 35% of breakdown voltage in polymer insulator. UV signal due to high voltage in polymer insulator is detected from about 1.7mV at 30kV to about 3mV at 70kV. Signal detected by ultra-sonic is increased at about 75% of breakdown voltage abruptly. It appears that error range is increased in boundary. UV sensor is needed must use from the practical and economical points of view.

  • PDF

2007년 세계 태양광발전산업 현황 (Status of Photovoltaics in the world)

  • 유권종;강기환;박경은;김현일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1132-1133
    • /
    • 2008
  • Amid the booming research on new and renewable energy, the photovoltaic(PV) industry has been growing around the PV advanced countries such as Japan, Germany, Europe and USA. In recent years, China became a strong performer in the world PV market share, increasing solar cell production rapidly. Both world solar cell and module production and installation rose steadily in 2007 like recent bumper years. In 2007, the PV industry produced 4.28GW and the installations reached a record high of 2.83GW, representing growth of 60percent over the previous year.

  • PDF

LabVIEW 기반의 적응제거기법을 활용한 철도전력설비 이벤트 분석 연구 (LabVIEW-based Event Analysis for Railway Power Installations by using Adaptive Cancellation Method)

  • 유제호;조수환;신승권;김형철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1575-1576
    • /
    • 2015
  • 전기철도와 같이 순간적으로 대용량의 전류를 끌어 쓰는 부하들은 주변 전력설비에 큰 부담을 주게 된다. 그로 인해 설비의 노후화가 앞당겨지므로 지속적인 모니터링을 통해 설비의 상태를 진단할 필요가 있다. 그러나 현재 상용화된 전력품질 해석용 장비들의 기능은 이러한 요구를 충족시키지 못하기 때문에 본 논문에서는 적응제어기법을 활용한 이벤트 감지 기법을 소개하고 이를 LabVIEW로 구현하여 철도 전력설비의 이벤트 분석 기법을 제시한다.

  • PDF

275kV XLPE절연 전력케이블의 해외프로젝트 적용 (Application of 275kV XLPE Power Cables for Overseas Protect)

  • 권병일;성정규;한창석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1736-1738
    • /
    • 2002
  • Oil-filled power cables and XLPE power cables have been globally applied for extra-high-voltage underground power transmission lines. The application of XLPE cables for the transmission lines have been largely increased at the domestic and overseas projects because of some issues. O.F cables have some week points, related with the issues of the environmental pollution and the needed maintenance work, even though they have been applied for several ten years and their reliability has been proven. Meanwhile, the demands on XLPE power cables increase as their manufacturing technologies have been improved and their simplicity of installations has been focused on. In Korea, for the first time, the 275kV XLPE cable is to be applied at an overseas power plant project. This paper introduces the project profile, the design of the XLPE cable and its accessories, the cable system design and the installation design.

  • PDF

일점접지방식을 이용한 전자교환기 방호의 실제 (Engineering Practice for ESS Protection by means of One Point Grounding System)

  • 김수형;서정욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.502-505
    • /
    • 1988
  • This paper is to demonstrate the effectiveness of one point grounding in support of ESS protection. One point grounding provides for the dispatching of excess energy for protection of switching equipment and personnel from lightning discharge hazards and for a natural sink for noise from atmospheric lightning and power transients. In most ESS installations there are a number of different items that must be maintained at a common ground potential for safety, fault protection or noise reduction. The items typically consist of power systems, heating and ventilating systems, distributing frames, repeating equipmets, switching equipments, etc. Grounding system of an ESS Office is most effective when all the ground points are connected to a single, common earth. The one point grounding prvides a common reference potential, keeping all the items of telecommunications facility free from the earth current and voltage hazards.

  • PDF

EXCITATION SYSTEM MODERNIZATION OF THERMAL POWER PLANT

  • Kim, Chan-Ki;Kim, Jang-Mok;Rhew, Ho-Sun
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2024-2026
    • /
    • 1998
  • Many power plants built 20-30 years ago are facing problems associated with the excitation system used for controlling generator output voltage. After years of reliable operation, generation is experiencing increased down time due to maintenance associated with the exciting excitation equipment. Reliability of the excitation system has become an issue, especially where many of these generation plants may be critical to the internal processes used for manufacturing. Wear out mechanisms such as those associated with the wire wound rheostat the electromechanical voltage regulator, insulation failures of the rotating exciter and commutator deterioration have become real problems typical of many older installations. These are some of the issues that are affecting system reliability for older power plants. This paper will address typical problems associated with the old excitation systems and the justification for a replacement static excitation system used in many Paper Mills.

  • PDF