• 제목/요약/키워드: Electrical Installation

검색결과 6,499건 처리시간 0.028초

고온 초전도 모델 케이블의 임계전류 및 교류손실 특성 (Critical Current and AC loss Characteristics of mini-model HTS cable)

  • 김해준;심기덕;김재호;조전욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.809-810
    • /
    • 2006
  • Reduction of AC losses is very important for realizing HTS cable and it had been reported that the same layer current controlled by twisting pitch and direction could reduce the AC losses effectively. During the long-term development of HTS cables, the superconductor AC losses will need to be reduced to a level determined by the economics of each installation and the efficiency of the refrigeration. Theoretical models have been developed to predict the magnitude of the losses in cables composed of several layers of flat HTS tapes. This paper is manufactured mini-model HTS cable and voltage signal line to spiral shape. Mini-model HTS cable is composed of 13 HTS tape. We measured to critical current and AC loss and compared used lock-in-amp to cancel coil. This data is useful to HTS cable of DAPAS program.

  • PDF

수도관로 소수력발전설비에 수격작용으로 인한 고장대책 (Trouble and Measure Owing to Water-hammer in Small Hydropower Turbine System Of Waterpipe)

  • 이형묵;김기원;변일환;홍정조;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.671-672
    • /
    • 2006
  • Recently the development of small hydropower generation with using water pipes is revitalized by the water works facilities. However, when the tubine generator is in case of emergency stop by the internal and external accidents, it causes water hammer in water pipes and suspension of water supply. To prevent these problems of small hydropower generator, we has analyzed water supply patterns, installation position and water pipe systems.

  • PDF

자유이물에 의한 GIS 내부 코로나특성 연구 (Corona Discharge In GIS Initiated by Free Conducting Particles)

  • 윤진열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1801-1803
    • /
    • 1997
  • The Gas Insulated Switchgear(GIS) has made it an indispensible part of power transmission network. In order that the GIS may have its high reliability, it is necessary to pay careful attention to its whole process e.g., designing, manufacturing, installation, and operation. The main hazard in GIS comes from free conducting particles, which can move and cause breakdown under the influence of the electric field. Although the concentration on protecting the GIS inner part against the free conducting particles is made, it is, actually, almost impossible to avoid the hazard from the particles throughly. In this paper, the corona discharge in GIS initiated by the free conducting particles was discribed through laboratorial experiment The magnitude of the corona discharge voltage was measured using current measuring method by the impedance. The purpose of this experiment is to get fundamental data which is essential to develop GIS diagnosis technology.

  • PDF

울산 공업탑 환경 조명등 설치 (Installation of Environmental Lights on the Industrial Tower of Ulsan)

  • 황갑신;강원구;김진환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.816-818
    • /
    • 1997
  • 전력사업은 설비사업인 만큼 고객과 밀접한 관계가 있으며, 고객의 지지기반이 없으면 사업을 할 수 없다고 해도 과언이 아니다. 한전 울산지점에서는 공익사업자로서의 국민의 지지기반을 확충하고자 울산 공업탑에 우리나라 최초로 "환경 조명등"을 시설하여 '96. 7. 18 점등식을 갖고 울산시에 기부 체납하는, 차원을 달리하는 새로운 사회사업 활동을 시도한 후 시민 여론조사를 실시한바, "한전의 사회 기여 인지도가 90%이상"으로 나타나는 큰 성과를 거두었으며, 이번 환경 조명등 사업을 시행하면서 경험한 바로 미루어 볼 때 앞으로 전력사업자는 다양한 사회사업을 많이 하는 것이 바람직하고, 또한 이를 통한 고객의 지지기반 구축을 확대 하므로서 전력사업을 발전시켜 나가는 것이 바람직하다고 사료된다.

  • PDF

초전도고장전류제한기의 고장전류억제효과와 동작파라메타 설정방법에 대한고찰 (On Fault Current Limitering and Design Method of the Specific Parameter of Superconducting Fault Current Limiter)

  • 홍원표;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.972-974
    • /
    • 1997
  • Design & Operation of power system for meeting increase of electric Power demand is becoming more difficult and complex. One of reasons is increase of fault current. As one of the most effective methods for suppressing the fault current installation of SFCL is expected. These paper describes a method of fault analyses of power system with SFCLs, and also discusses determination of specification of SFCLs, effects of limiting the fault current due to SFCLs by use of the model system of two - bus electric power system with single transmission lines.

  • PDF

하이브리드 복합재 차체 구조물의 성형공정에 관한 연구 (A Study on the manufacturing process for Hybrid Composite Carbody Structures)

  • 신광복;조세현;이상진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.461-466
    • /
    • 2004
  • The hybrid composite carbody structures were considered as the carbody system of Korean Tilting Train eXpress(TTX) to achieve the lightweight design. The TTX carbodies are composed of the carbody shell made of the sandwich composite structure and the undeframe made of the metal structure. The sandwich structures were used to minimize the weight of carbody, and the metal underframe was used to modify the design easily and to keep the strength of underframe by the installation of the electrical equipments. The sandwich carbody structures will be cured in an autoclave. In this paper, the manufacturing processes of the TTX carbody structures were introduced briefly.

  • PDF

A Safe and Reliable Method for Installing Wireless LAN into a Hospital

  • Hanada, Eisuke;Kudou, Takato
    • Journal of electromagnetic engineering and science
    • /
    • 제11권4호
    • /
    • pp.269-273
    • /
    • 2011
  • A medical environment in which patient information can be accessed anytime / anywhere is called a "ubiquitous environment". To realize such an environment, the installation of wireless LAN is quite effective. Because the maximum radio wave output (antenna power) is set low in Japan, it has been easy to safely introduce wireless LAN into hospitals, to date mainly into large hospitals. However, if the placement of access points is not done properly, problems will occur, such as signals not reaching the desired area. A solution to these types of problems is to do an electromagnetic-field propagation simulation, which should be performed before construction of the hospital. It is also necessary to protect against security problems, such as signal interception or illegal access. We herein show our procedures for the safe introduction of wireless LAN.

시스순환전류 저감장치 설치시 거리계전기 응동 특성 평가 (Evaluation of Distance Relay Operation Characteristic with the Reduction Devices Installed in Underground Power Cable Systems)

  • 정채균;이종범;강지원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.494-496
    • /
    • 2003
  • This paper analyses the operation characteristic of distance relay when the single line to ground occurs in underground power cable systems that reduction device of sheath circulating current is installed. To apply that reduction device to actual system, the change of line impedance calculated at relay point is also analysed by the connection type of SVLs and fault location, fault inception angle with the installation of reduction device of reactor or not.

  • PDF

불평형배전계통에서 부하모형을 고려한 분산형전원의 설치 및 운영계획 (Placement and Operation Planning of DG System considering Load Modeling in Unbalanced Distribution Systems)

  • 김규호;이유정;이상봉;이상근;유석구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.396-398
    • /
    • 2003
  • This paper presents the scheme for load model based dispersed generation system (DGs) installation and operation in unbalanced distribution systems. Groups of each individual load model consist of residential, industrial, commercial, official and agricultural load. The main idea of solving fuzzy nonlinear goal programming is to transform the original objective function and constraints into the equivalent multiple objective functions with fuzzy sets to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithms. The method proposed was applied to IEEE 13 bus test systems to demonstrate its effectiveness.

  • PDF

배전자동화 기반의 배전계통 최적운전 기법 개발 (The development of optimal operating system in distribution networks based on distribution automation)

  • 하복남;설일호;정미애;신익수;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.427-429
    • /
    • 2003
  • The reliability performance of distribution networks will be enhanced with the installation of application programs including feeder reconfiguration program for loss minimization and optimization of system capacity. Although the basic functions of remote monitoring and remote control provide no measurable cost benefit the suite of application programs developed and now being commissioned by KEPCO, the future will continue to offer this utility with substantial savings in system operational costs, improve system reliability and customer service.

  • PDF