• 제목/요약/키워드: Electrical Installation

검색결과 6,499건 처리시간 0.032초

충격파 부동작형 누전차단기의 뇌써지 응답 특성 (Lightning Surge Response Characteristics of Non-tripping Type Earth Leakage Breakers for Impulse)

  • 이재복;명성호;조연규;장석훈;김정식;길경석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1688-1690
    • /
    • 2002
  • The unpredictable threat of lightning surge is ever increasing in today's low-voltage power supplies. Thus Surge protection devices for AC mains are more widely used. The false-tripping of the earth leakage breaker (ELB) can be caused by the installation of surge protection devices with MOV. In order to examine the cause of malfunction, the malfunction characteristics of ELBs applied by lightning surge were investigated experimentally. As a result, all of them brought about malfunctions under 7 kV of the impulse voltage. The suitable position of MOV and use of zener diode were suggested to eliminate the problems.

  • PDF

경사지에서의 345kV XLPE $1C{\times}2000mm^2$ 케이블 코아 활락 현상 연구 (The study on slipping down phenomenon of 345kv XLPE cable in inclinatior)

  • 백주홍;남석현;이수길;허회덕;김동욱;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1782-1784
    • /
    • 2002
  • In this paper, the coefficient of friction betwee and sheath in 345kv XLPE cable was measured the simulated inclinated condition of You-Youngdeungpo transmission line. The phenomena of slipping down the simu inclination was investigated theoretically usin measured data and was analyzed from experim result. The measured and analyzed result were conside be as a reference data for real installation of XLPE Youngseo-Youngdeungpo transmission line.

  • PDF

275kV XLPE절연 전력케이블의 해외프로젝트 적용 (Application of 275kV XLPE Power Cables for Overseas Protect)

  • 권병일;성정규;한창석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1736-1738
    • /
    • 2002
  • Oil-filled power cables and XLPE power cables have been globally applied for extra-high-voltage underground power transmission lines. The application of XLPE cables for the transmission lines have been largely increased at the domestic and overseas projects because of some issues. O.F cables have some week points, related with the issues of the environmental pollution and the needed maintenance work, even though they have been applied for several ten years and their reliability has been proven. Meanwhile, the demands on XLPE power cables increase as their manufacturing technologies have been improved and their simplicity of installations has been focused on. In Korea, for the first time, the 275kV XLPE cable is to be applied at an overseas power plant project. This paper introduces the project profile, the design of the XLPE cable and its accessories, the cable system design and the installation design.

  • PDF

전기 무효전력비용을 고려한 조상설비계획 (Reactive Power Planning Considering Reactive Power Support Cost of Generator)

  • 이철휴;이상호;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.181-183
    • /
    • 1999
  • As one of ancillary services, voltage support and reactive power service should be compensed properly for its contribution. In this paper, a cost-based reactive power planning is presented. which minimizes the total cost of reactive power support of generators and VAR compensation facility installation. Reactive power support of generator is evaluated by the opportunity costs of reduced energy sale considering the varying SMP(system marginal price) in power market, Gradient projection method is applied to solve this reactive power planning using IEEE14 bus system.

  • PDF

태양광 발전시스템의 최적설계를 위한 운전특성 분석 (Analysis for Optimal Design of PV System)

  • 소정훈;유권종;정명웅;최주엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.281-285
    • /
    • 2002
  • This paper compares not only the performances of estimate by computer simulation considering parameters of system specifications, installation and surrounding conditions with those of real PV system and but also shows verification of designed value. We evaluate the performances of PV system with changing of parameter, specialty a field type and suggest optimum condition in each field type. in the future, we will intend to develop an analysis tool and construct database for optimum design of PV system.

  • PDF

A Protection Technique Against the Damages Caused by Lightning Surges on Information and Communication Facilities

  • Lee, Bok-Hee;Kang, Sung-Man;Ahn, Chang-Hwan
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권4호
    • /
    • pp.117-122
    • /
    • 2003
  • The AC power lines and signal lines of info-communication networks are routed on overhead poles and are highly exposed to lightning strikes. Due to the potential difference between grounding points of AC power lines and signal lines, the electronic equipments connected to the signal lines can easily be damaged by lightning surges. In this work, in order to develop reliable methods of protecting information and communication facilities from lightning surges, the reliability and performance of SPDs (surge protective devices) were experimentally investigated in an actual-sized test circuit. The behaviors of SPDs against lightning surges from AC power lines and signal lines and the coordinated effects of SPD installation methods were evaluated. As a consequence, it was confirmed that the bypass arrester methods and common grounding system are both highly effective.

인버터 DSM 프로그램의 경제성평가 (Economic Analysis of Inverter DSM Program for Inverter)

  • 이학주;권성철;최병윤;이승윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.521-523
    • /
    • 2001
  • The electric demand increase, financial need for new power plant constructions and environmental problem have led to search for more efficient energy production and energy conservation technology. To minimize the construction of power plants and reduce total power consumption include installation of inverters to motors used for pumps and fans. However, the high price of Inverters is the biggest obstacle to their wide use. Accordingly, to maximize the effect of energy saving by the expanded use of inverters, governmental economic support as well as the analysis of energy saving effect. This paper presents the cost-effectiveness analysis for DSM program evaluation and case study to analyze inverter DSM program.

  • PDF

765 kV 조립식점퍼장치의 점퍼혼 설계기법 및 적용방안 (Design method and application on the jumper-horn of the 765 kV prefabricated jumper device)

  • 조성배;강연욱;윤상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2086-2088
    • /
    • 1999
  • 765kv Transmission lines of the contaminated areas need many insulators due to the contamination. So the length of the arcing hem is very long. Because it is very difficult to install the arcing hem on insulator string sets due to its length, we must install the arcing horn on the jumping devices, and studied about the jumper horn. This paper described the investigation and analysis of the installation status of the arcing horn, and the design of the jumper horn for 765 kV transmission lines.

  • PDF

밧데리 진단 및 감시장치 제작 (Fabrication of Battery Checking & Monitoring System)

  • 이상철;나채동;유재문;최식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2156-2159
    • /
    • 1998
  • This paper describes a Battery Checking & Monitoring System for monitoring battery cell and power system in Uninterruptible Power Supplies(UPS). The system is capable of measuring, in a matter of setting time, float and discharge voltage of up to 240 cells in a single installation, and has the memory capacity to store battery's alarm data information on up to 200 separate sites. This system are easy to maintain and attain cost effectively, so that prepared for meeting the customer's service needs immediately. The system is additionally programmed with a each model, that will enable to accurately determine the remain battery capacity in a UPS system following a short discharge test. It is also equipped with remote interrogation and control facilities.

  • PDF

GIS 내 금속입자의 부상전압과 부분방전특성 연구 (Lift-Off Voltage and Partial Discharge Characteristics of Free Conducting Particles in GIS)

  • 윤진열;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1684-1686
    • /
    • 1998
  • Gas Insulated Switchgear(GIS) acts as an indispensible part in power transmission network. In order that GIS may have its high reliability, it is necessary to pay careful attention to its whole process e.g., designing, manufacturing, installation, and operation. The main hazard in GIS comes from free conducting particles, which can move and cause breakdown under the influence of the electric field. Although the concentration on protecting the GIS inner part against the free conducting particles is made, it is, actually, almost impossible to avoid the hazard from the particles throughly. In this paper, using the EHV test chamber, partial discharge quantity in GIS was measured when free conducting particles initiate to discharge for providing fundamental data for the purpose of developing predictive diagnosis technology on site GIS.

  • PDF