• Title/Summary/Keyword: Electrical Inspection

Search Result 613, Processing Time 0.023 seconds

Quantitative Analysis on the Electrical Fire Preventive Effect of Safety Inspection for Electrical Facilities for General Use (일반용 전기설비 안전점검의 전기화재 예방효과에 대한 정량적 분석)

  • Kim, Taek-Hee;Yoo, Jae-Geun;Jeon, Jeong-Chay
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.2
    • /
    • pp.45-49
    • /
    • 2015
  • This paper presents a quantitative analysis method to quantitatively indicate a electrical fire preventive effect of safety inspection for electrical facilities for general use. Logic model was developed based on whether enforcement of safety inspection for electrical facilities, and then the developed analysis model was converted to hydraulic model by using mathematical logic. The electrical fire preventive effect of safety inspection for electrical facilities was quantitatively calculated by applying electrical safety inspection results and fire statistics for five years to the developed hydraulic model. The results show that electrical fire preventive effects of 5,542 cases on annual average for five years.

Problems and Improvement Method of Safety Management of Electrical Facilities for General Use (일반용 전기설비 안전관리의 문제점과 개선방안)

  • Jeon, Jeong-Chay;Jeon, Hyun-Jae;Lee, Sang-lck;Yoo, Jae-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.488-495
    • /
    • 2007
  • In spite of regular electrical safety inspection and improvement management of incongruent facilities, over 80 percent of electrical fires were generated in electrical facilities for general use, and the prevention of electrical safety accidents gets more difficult because of incomprehension on electrical safety inspection system, the increasement of non-inspection electrical facilities user, un-installation of residual current protective devices and leaving unsuitable equipments alone. This paper analyzed electrical safety inspection system of electrical facilities for general use and results of safety inspection and electrical fire statistics, and deducted the related problems. Also, improvement method of safety management of electrical facilities for general use was proposed in view of electrical safety inspection system, inspection implementation method, electrical fire statistics establishment, electrical safety consciousness and remote electrical safety inspection system.

  • PDF

A New Robotic 3D Inspection System of Automotive Screw Hole

  • Baeg, Moon-Hong;Baeg, Seung-Ho;Moon, Chan-Woo;Jeong, Gu-Min;Ahn, Hyun-Sik;Kim, Do-Hyun
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.5
    • /
    • pp.740-745
    • /
    • 2008
  • This paper presents a new non-contact 3D robotic inspection system to measure the precise positions of screw and punch holes on a car body frame. The newly developed sensor consists of a CCD camera, two laser line generators and LED light. This lightweight sensor can be mounted on an industrial robot hand. An inspection algorithm and system that work with this sensor is presented. In performance evaluation tests, the measurement accuracy of this inspection system was about 200 ${\mu}m$, which is a sufficient accuracy in the automotive industry.

Motorcycle Inspection Standards Development II (이륜자동차 검사기준 개발 II)

  • Hong, Seungjun;Ha, Taewoong;Lim, Jaemoon
    • Journal of Auto-vehicle Safety Association
    • /
    • v.9 no.4
    • /
    • pp.55-60
    • /
    • 2017
  • This paper presents the motorcycle inspection standards of electrical system, frame & body, lights and speedometers. 187 real-world motorcycles are visually and mechanically inspected according to the developed inspection standards. The non-compliance rate of inspection standards of the lights is 23.7% and main causes are damage, tinting, painting and coloration of head-lamp, number plate lamp, front-rear position lights, stop lamp and direction indicators of motorcycles. Also, 28.4% of motorcycles are dropped from the luminous intensity inspection standard. Motorcycle electrical system cannot be visually inspected. The motorcycle inspections standards are improved reflecting 187 cases of real-world motorcycle inspection results.

Optimal Operation for Reverse Supply Chain Incorporating Inspection Policy into Remanufacturing of Used Products

  • Yamaguchi, Shin;Kusukawa, Etsuko
    • Industrial Engineering and Management Systems
    • /
    • v.16 no.1
    • /
    • pp.1-21
    • /
    • 2017
  • This paper discusses a reverse supply chain (RSC) which consists of the process flows from procurement of used products collected from a market, through remanufacturing products from the used products, to sales of the products in a market. In general, it is conceivable for the RSC to face the uncertainty in quality of used products collected from a market. Inspection is one of efficient methods to deal with the problem regarding quality of used products. However, there is a trade-off between inspection cost and inspection accuracy. This paper focuses on the following five types of inspection: (1) 100% inspection, (2) sampling inspection, (3) sampling inspection with screening of rejected lots, (4) sampling inspection with screening of acceptable lots, and (5) no inspection, and determines the optimal operation consisting of the optimal number of procured used products and the optimal inspection policy. Numerical analysis clarifies not only how changes of conditions of the RSC affect the manufacturer's optimal operation but also features of each inspection type. In addition, from the results of numerical analysis, this paper shows the usability to add the proposed inspection in this paper, the sampling inspection with screening of acceptable lots, to choices of inspection type.

Review on the Relationship of Dissolved Gas Analysis and Internal Inspection of Transformer (변압기 절연재료 분석과 내부점검 결과와의 상관성 연구)

  • Park, Hyun-Joo;Nam, Chang-Hyun;Jung, Nyun-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1869-1873
    • /
    • 2010
  • For reliable operation of oil-filled electrical equipment, monitoring and maintenance of insulating oil is essential. Dissolved gas analysis(DGA) is widely used for monitoring faults in high voltage electrical equipment in service. Therefore, oil analysis should be monitored regularly during its service life. KEPCO has investigated thousands of dissolved gas analysis data since 1985, and conducted studies on the relationship of gas in oil analysis and internal inspection results of transformer. As the results, KEPCO revised criteria for transformer diagnosis and has applied it since 2008. Almost of 100 cases of internal inspection results since 2001 have been investigated. This paper presents the correlation of the fault-identifying gases with faults found in actual transformers and how should we approach to internal inspection of transformer by dissolved gas analysis.

A Specialized Reader for High Speed UHF RFID Tag Inlay Inspection Equipment (고속 UHF RFID 태그 검사 장비를 위한 전용 리더)

  • Bae, Sung Woo;Park, Jun-Seok;Seong, Yeong Rak;Oh, Ha-Ryoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.63-69
    • /
    • 2014
  • RFIDs have not become widespread as expected partly due to the cost, size, read range, and reliability problems of tags. The success rate of reading must be improved in order for RFIDs to be widely adopted. Quality control of tags is crucial to meet this requirement. In this study, we designed and implemented a high-performance reader used in inspection equipment that conducts prior inspection of tags. To improve performance of the developed reader, the baseband modem and command processor (CP) were designed using H/W logic and implemented with FPGA. The inspection of small pitch inlays was made possible through the antenna shielding device and H/W command processor function. This equipment enables accurate evaluation of performance and identification of tags satisfying a given read range. By contributing to sort out defective tags, the results can ultimately lead to more stable RFID services.

Development of a Remote Inspection Method and Device for Line Sleeves on Transmission Line (송전선로 직선슬리브 원격점검 방법 및 장치)

  • Lee, Jae-Kyung;Jung, Nam-Joon;Kim, Ho-Ki;Kim, Kyeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.4
    • /
    • pp.206-213
    • /
    • 2011
  • Line sleeves, which used to connect ACSR cables when transmission lines were constructing, sometimes cause power transmission failure due to deterioration and corrosion. Therefore, power transmission line should be inspected regularly to prevent national disaster. Current inspection tool detects insertion length of transmission line on line sleeves, the inspection tool includes enormous error by operator. Moreover, the system is not controlled remotely, negligent accident would be caused while inspecting. To deal with those problems, KEPCO reviewed several ways to inspect line sleeves and proposes new method to inspect line sleeve by measuring magnetic flex which penetrate junction of steel and aluminum sleeve. The developed inspection tool is reliable enough to detect eccentric sleeves. Also, the developed inspection device was applied on actual transmission line and verified its effectiveness.

A Study on the Safety Checking and Testing method of the underground power transmission line (OF Cable) (지중송전선로 안전관리 방안 (OF케이블))

  • Choi, Jong-Soo;Park, Kang-Seo;Jeon, Jun-Man
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.429-434
    • /
    • 2009
  • In this paper it was written about the safety management plan for underground power transmission cable, and it guarantees the reliable electric power supply and facility management to prevent an electric disasters according to that. Recently fires which happens on OF Cable lead to a breakdown of power system and cause a power outage of wide area and serious social problems. So it needs an improvement of inspection ability on OF cable as well as a strict inspection system to prevent that problems in advance and it will bring us the development of electric safety management and the reliable electric power supply.

  • PDF

Automatic Extraction of Component Inspection Regions from Printed Circuit Board by Image Clustering (영상 클러스터링에 의한 인쇄회로기판의 부품검사영역 자동추출)

  • Kim, Jun-Oh;Park, Tae-Hyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.472-478
    • /
    • 2012
  • The inspection machine in PCB (printed circuit board) assembly line checks assembly errors by inspecting the images inside of the component inspection region. The component inspection region consists of region of component package and region of soldering. It is necessary to extract the regions automatically for auto-teaching system of the inspection machine. We propose an image segmentation method to extract the component inspection regions automatically from images of PCB. The acquired image is transformed to HSI color model, and then segmented by several regions by clustering method. We develop a modified K-means algorithm to increase the accuracy of extraction. The heuristics generating the initial clusters and merging the final clusters are newly proposed. The vertical and horizontal projection is also developed to distinguish the region of component package and region of soldering. The experimental results are presented to verify the usefulness of the proposed method.