• 제목/요약/키워드: Electrical Charging

검색결과 866건 처리시간 0.025초

선박 비상조명 원격 모니터링 제어 (A Study on the Remote Monitoring and Control of Ship's Emergency Lighting System)

  • 양현숙;김건우;임현정;문정필;이성근;김윤식
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.207-210
    • /
    • 2005
  • This paper describes a design of several ship's emergency lighting system(SELS) that power factor is improved and power is controlled extensively, and techniques to control and monitor this system in remote distance by PC serial communication. The remote monitoring control system is composed of emergency power supply system (EPSS), half bridge(HB)inverter, fluorescent lamp(FL), microprocessor, multi communication interface. EPSS checks the voltage of the emergency backup battery in real time. In case that the voltage of 13[V] or less has been detected for 5[msec] or longer for 3 times in a row, charger circuit is connected for battery charging. Experimental works using proposed system confirm that speedy and stable power to be supplied when main power source cut-off, compared with conventional analog type, and input power up to 35.0[%] by adjusting of pulse frequency of the HB inverter.

  • PDF

The Microbe Removing Characteristics Caused by Dirty Water Using a Simple Pulsed Power System

  • Kim, Hee-je;Song, Keun-ju;Song, Woo-Jung;Kim, Su-Weon;Park, Jin--Young;Joung, Jong-Han
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권3호
    • /
    • pp.91-95
    • /
    • 2004
  • The pulsed power system is widely available for use in pulse generator applications. Generally, the pulse generator is required for very short pulse width and high peak value. We have designed and fabricated our own pulsed type power system and through its use, we investigated microbe removal characteristics. This paper introduces a simple pulsed power system for removing various microbes caused by dirty water. This system includes a 2 times power supply circuit, IR2110 operated by using a fixed voltage regulator 7812 and 7805, and the switching MOSFET (Metal Oxide Semiconductor Field Effect Transistor). We can also control this process by using a PIC one chip microprocessor. As a result, we can obtain good removing characteristics of various microbes by adjusting the charging voltage, the pulse repetition rate and the electrical field inducing time.

Fault Diagnosis of Transformer Based on Self-powered RFID Sensor Tag and Improved HHT

  • Wang, Tao;He, Yigang;Li, Bing;Shi, Tiancheng
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.2134-2143
    • /
    • 2018
  • This work introduces a fault diagnosis method for transformer based on self-powered radio frequency identification (RFID) sensor tag and improved Hilbert-Huang transform (HHT). Consisted by RFID tag chip, power management circuit, MCU and accelerometer, the developed RFID sensor tag is used to acquire and wirelessly transmit the vibration signal. A customized power management including solar panel, low dropout (LDO) voltage regulator, supercapacitor and corresponding charging circuit is presented to guarantee constant DC power for the sensor tag. An improved band restricted empirical mode decomposition (BREMD) which is optimized by quantum-behaved particle swarm optimization (QPSO) algorithm is proposed to deal with the raw vibration signal. Compared with traditional methods, this improved BREMD method shows great superiority in reducing mode aliasing. Then, a promising fault diagnosis approach on the basis of Hilbert marginal spectrum variations is brought up. The measured results show that the presented power management circuit can generate 2.5V DC voltage for the rest of the sensor tag. The developed sensor tag can achieve a reliable communication distance of 17.8m in the test environment. Furthermore, the measurement results indicate the promising performance of fault diagnosis for transformer.

풍력발전과 전기자동차가 전력계통의 신뢰도에 미치는 영향 평가 (Impact Analysis of Wind Power on Power System Reliability with Electric Vehicles)

  • 김담;박현곤;권헌규;박종근
    • 전기학회논문지
    • /
    • 제64권11호
    • /
    • pp.1535-1542
    • /
    • 2015
  • An increasing number of electric vehicles (EVs) in power system affects its reliability in various aspects. Especially under high EV penetration level, new generating units are required to satisfy system's adequacy criterion. Wind power generation is expected to take the major portion of the new units due to environmental and economic issues. In this paper, the system reliability is analyzed using Loss of Load Expectation (LOLE) and Expected Energy Not Served (EENS) under each and both cases of increasing wind power generation and EVs. A probabilistic multi-state modeling method of wind turbine generator under various power output for adequate reliability evaluation is presented as well. EVs are modeled as loads under charging algorithm with Time-Of-Use (TOU) rates in order to incorporate EVs into hour-to-hour yearly load curve. With the expected load curve, the impact of EVs on the system adequacy is analyzed. Simulations show the reliability evaluation of increasing wind power capacity and number of EVs. With this method, system operator becomes capable of measuring appropriate wind power capacity to meet system reliability standard.

대칭적인 스위치 구조 기반 RF 플라즈마 시스템 적용 전기적 가변 커패시터 (Electrical Variable Capacitor based on Symmetrical Switch Structure for RF Plasma System)

  • 민주화;채범석;김현배;서용석
    • 전력전자학회논문지
    • /
    • 제24권3호
    • /
    • pp.161-168
    • /
    • 2019
  • This study introduces a new topology to decrease the voltage stress experienced by a 13.56 MHz electrical variable capacitor (EVC) circuit with an asymmetrical switch structure applied to the impedance matching circuit of a radio frequency (RF) plasma system. The method adopts a symmetrical switch structure instead of an asymmetrical one in each of the capacitor's leg in the EVC circuit. The proposed topology successfully reduces voltage stress in the EVC circuit due to the symmetrical charging and discharging mode. This topology can also be applied to the impedance matching circuit of a high-power and high-frequency RF etching system. The target features of the proposed circuit topology are investigated via simulation and experiment. Voltage stress on the switch of the EVC circuit is successfully reduced by more than 40%.

Energy harvesting techniques for remote corrosion monitoring systems

  • Kim, Sehwan;Na, Ungjin
    • Smart Structures and Systems
    • /
    • 제11권5호
    • /
    • pp.555-567
    • /
    • 2013
  • An Remote Corrosion Monitoring (RCM) system consists of an anode with low potential, the metallic structures against corrosion, an electrode to provide reference potential, and a data-acquisition system to ensure the potential difference for anticorrosion. In more detail, the data-acquisition (DAQ) system monitors the potential difference between the metallic structures and a reference electrode to identify the correct potential level against the corrosion of the infrastructures. Then, the measured data are transmitted to a central office to remotely keep track of the status of the corrosion monitoring (CM) system. To date, the RCM system is designed to achieve low power consumption, so that it can be simply powered by batteries. However, due to memory effect and the limited number of recharge cycles, it can entail the maintenance fee or sometimes cause failure to protect the metallic structures. To address this issue, the low-overhead energy harvesting circuitry for the RCM systems has designed to replenish energy storage elements (ESEs) along with redeeming the leakage of supercapacitors. Our developed energy harvester can scavenge the ambient energy from the corrosion monitoring environments and store it as useful electrical energy for powering local data-acquisition systems. In particular, this paper considers the energy harvesting from potential difference due to galvanic corrosion between a metallic infrastructure and a permanent copper/copper sulfate reference electrode. In addition, supercapacitors are adopted as an ESE to compensate for or overcome the limitations of batteries. Experimental results show that our proposed harvesting schemes significantly reduce the overhead of the charging circuitry, which enable fully charging up to a 350-F supercapacitor under the low corrosion power of 3 mW (i.e., 1 V/3 mA).

UHF RFID 시스템으로부터의 저전력 RF 에너지 하베스팅 (Low Power RF Energy Harvesting from the UHF RFID System)

  • 박정흠
    • 조명전기설비학회논문지
    • /
    • 제23권1호
    • /
    • pp.182-187
    • /
    • 2009
  • 본 논문에서는 에너지 하베스팅의 일환으로 상용의 RFID시스템의 리더 안테나에서 방사되는 RF에너지를 활용하여 무선센서노드의 전원부를 구성하고자 하였다. 이를 위해 렉테나(Rectenna)를 구성하고 효율이 높은 부스트 컨버터를 구성하여 RF전력으로부터 배터리를 충전할 수 있는 DC전력을 얻도록 하였다. RFID 안테나로부터 1.2[W] RF출력 시, 구현된 렉테나로 1[m]거리에서 3.1[mW], 5.5[m]에서 1[mW]정도의 전력을 얻을 수 있었다. 배터리와 연결 시 변환효율을 높이기 위한 부스트 컨버터의 특성은 4[m]거리에서 변환효율 79.3[%], 실제 변환되어 배터리를 충전할 수 있는 전력은 1.36[mW]를 얻을 수 있었으며, 이 값은 무선센서노드로 응용이 가능한 값이다.

태양광 시뮬레이터와 PCS를 이용한 배터리 방전시스템 구성 (Battery Discharge System Configuration using Photovoltaic Simulator and PCS)

  • 정다움;박성민;박성미;박성준;문승필
    • 한국산업융합학회 논문집
    • /
    • 제23권3호
    • /
    • pp.491-498
    • /
    • 2020
  • Recently, In the production line of batteries, charge and discharge tests are essential to verify battery characteristics. In this case, the battery charging uses a unidirectional AC/DC converter capable of output voltage and current control, and the discharge uses a resistive load. Since this method consumes energy during discharge, it must be replaced with a bi-directional AC/DC converter system capable of charging and discharging. Although it is difficult to replace the connected inverter part of the bi-directional AC/DC converter system due to the high cost, the spread of the solar-connected inverter rapidly increases as the current solar supply business is activated, and thereby the solar-connected type Inverter prices are plunging. If it can be used as a power converter for battery discharge without program modification of the solar-powered inverter, it will have competition. In this paper, propose a new battery discharge system using a combination of a photovoltaic DC/DC simulator and photovoltaic PCS using a battery to be used as a power converter for battery discharge without program modification of a low-cost photovoltaic inverter. In addition, propose an optimal solar characteristic curve for the stable operation of PCS. The validity of the proposed system was verified using a 500[W] class solar DC/DC simulator and a solar PCS prototype.

에너지 저장장치의 계통 연계형 양방향 PCS 기술 (The grid-connected bidirectional PCS technology of the ESS)

  • 고봉운
    • 전기전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.1280-1287
    • /
    • 2019
  • 계통 연계 형 양방향 PCS 기술은 분산 형 신재생 에너지 스마트 그리드를 구현하기 위한 기술이며, 방대한 스마트 그리드 시스템 중 태양광 모듈로부터 수집된 전력 및 상용 계통전원을 이용하여 상시 전력을 충전하였다가 필요시 저장된 전력을 저압 계통 측으로 방출할 수 있도록 하는 하이브리드형 에너지 저장 장치이다. 이를 위해 MPPT 기능이 포함된 PV입력 전력변환기와 배터리 충·방전을 위한 양방향 전력변환기 및 DC Link 전압을 3상 380V AC 계통으로 출력하고 필요할 경우 계통전력을 AC/DC변환하여 양방향 DC/DC컨버터를 통해 배터리로 충전기능을 수행하는 인버터로 구성된 3개의 전력변환기 구조를 갖는 PCS를 설계 및 개발하였다. 현재 이 시스템을 정전 및 화재사고에 취약한 제주의 사이트에 적용하여 실증 및 운영하고 있다.

2단 평행판 전기집진기의 서브마이크론 입자 포집특성 실험 (Experiment on Collection Characteristics of Sub micron Particles in Two-Stage Parallel-Plate Electrostatic Precipitators)

  • 오명도;유경훈
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.237-246
    • /
    • 1994
  • Experimental data are reported for charging and collection of NaCl aerosols in the 0.03- to $0.2{\mu}m$-geometric-mean-diameter range in 2-stage parallel-plate electrostatic precipitators. The NaCl aerosols are generated with geometric standard deviation of about 1.74 and particle generation rate of about 10^9 particles/see by the constant output atomizer and injected into the air flow in the clean wind-tunnel. The 2-stage parallel-plate electrostatic precipitator installed in the test section of the wind-tunnel is operated with a positive corona discharge. The NaCl aerosols in the channel flow are sampled and transported to the aerosol particle number concentration measurement system by using the isoaxial sampling and transport system constructed based on the Okazaki and Willeke design. The aerosol particle number concentration measurement system measures the size distribution of submicrometer aerosols by an electrical mobility detection technique. It is confirmed from comparing the measured collection efficiencies in this study and the predicted ones by our previous theoretical analysis that the predicted collection efficiencies agree well with the experimental ones. It is also found from the comparison that below about $0.02{\mu}m$ all particles are not charged and the uncharged particles are not collected, and consequently 2-stage parallel-plate electrostatic precipitators are not suitable for that particle size range.

  • PDF